HomeMy WebLinkAboutS-398602(0
CD
CY)
C17
1
C\I
1
n
►i
Z
O
0
Z
W
I-
X
LU
rr
LLI
W
U)
I]J
Q
w
LL
BOLTHO-ES - 3 PLCS
EQUALLY SPACED 120°
APART JN 23 1/16' (586mm)
DIA B,C (SEE DETAIL)
RENTON
SEWER
MADE IN USA
COVER & FRAME
PLAN VIEW
25' D:A.
[635mm] 1'
3/4' �25mmJ
C19mm]
8 3/4' L 2 1/2'
[222mm] 164mm]
TYP
COVER SECTION VIEW
26 1/2' DIA _
C673mm]
25 1/4' DIA
E GASKET
1 1/16'
1/4' (6mm) DIA [27mm]
NEOPRENE GASKET
1 7
6
C152mm]
5/8' 23 3/8' DIA CL OPEIJ
[16mmJ 1594mm]
27 5/16' DIA
C694mm]
34 1/8' DIA
CB67mm] NOTES:
FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL.
2. USE FRAME AND COVER FOR STORM (SPECIFY
"DRAIN" ON COVER), SANITARY (SPEDIFY
"SEVIER"), OR WATER (SPECI=Y '[WATER").
+~►^ STD PLAN - 401
PUBLIC WORKS MANHOLE FRAME AND COVER
DEPARTMENT DECEM3ER 2008
COVER BOTTOM VIEW
BLT SDC, (ALLEN HEAD)
5/8-11 X 1.5 SS
RUBBER WASHER
EON BOLTING DETAIL
RECESSED
LIFT POCKET
o D� 3/4" LETTERING 'SEWER"
e SEWER (2) BOLT SOC. (ALLEN HEAD)
5/8" - 11 X 1.5 STAINLESS
STEREFSTE. PART #00981177
oOC�
1-3/16"
10-1/2"
5/8"
T1-1/8"
2-1/4" I BOLT DETAIL
CAST IRON RING AND COVER
1/4' 1 1/16'
C6mm] C27mm]
1/9,
[3mm]
1/8'
CR3mm1
GASKET GROOVE DETAIL
Not to Scale
FRAME
'-0" 21
DIAMETER 2'-0"
EFINJ- r--�-t
- i
8" CLASS "B"
\- SAND OR
ASPHALT
EXPANDABLE
FOAM
45' (1/8) BEND
45- (1/8) BEND
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTES:
1. 8" AND 5" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC.
No. 3698 (PRODUCT NO. 00369803) OR APPROVED EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY.
2. IN UNIMPROVED AREAS, POUR A 1'-0- THICK, 2'-0" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER.
Admftk APPROVED: STD. PLAN - 403.1
♦ PUBLIC WORKS 8" OR 6" CLEANOUT
DEPARTMENT FOR SANITARY SEWER MAIN M,1
PW [i Nl nn
D
OFFE ENGINEERS
13932 SOUTHEAST 159TH PLACE
RENTON, WASHINGTON 98058
PHONE: 425-260-3412
CONTACT: DARRELL OFFE, P.E.
EX. SEWER MAIN
PROPERTY LINE
(LENGTH AS NEEDED)
Z
_-SPOOL
3
I
o
3'-0'
�
8" SEWER STUBE
r,
FUTURE 4" SIDE SEWER
I
2"x 4" STUD MARKING POST PAINTED
SEWER MAIN TEE X 5" TEE
6" CAP/ WHITE WITH THE WORD "SEWER" STENCILED
W I
IN 3" HIGH BLACK LETTERS AND #6 W1R=
WRAPPED AROUND THE STUD AND
EXTENDED TO THE TOP OF THE STUD.
COUPLING
k>,
I
'
~ I
6"X6'X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER
(EAST JORDAN IRON WORKS PRODUCT NO. 00367502 OR
APPROVED EQUAL, SPECIFY "SEWER- ON LID),
I
(SEE STD. PLAN 403.1 FOR INSTALLATION)
I
r-______
L--_J
JM EAGLE THREADED CLEAN -OUT ADAPTER HUB
BEND AS
& PLUG (OR APPROVED EQUAL)
REQUIRED
EXISTING SANITARY
SEWER MAIN MIN. OPE
_2
\\
�6"
-FUTURE 4" SIDE SEWER
SEWER STUB
6"X6"X5' WYE `FUTURE 6"x 4" REDUCER
`SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCFDUR C FOR mm SEWER CONNECTIONS TO EXSTING SEWER MAIN
A. VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B. CONCRETE MAIN - CUT IN A NEW PVC 'TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
C. PVC h C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE
(OR APPROVED EQUAL).
D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED.
3000 PSI MIX
CONCRETE ' -F• / P�NO
BLOCKING �� 15
� µN
6" /1 HORIZONTAL
6" MIN. SEWER `SEWER MAIN
MAIN
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN BETWEEN 25' AND 45' TYPICAL SIDE SEWER
NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5'
LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
STANDARD SIDE SEWER STD. PLAN -406.1
• PUBLIC WORKS INSTALLATION APP ED. 4.A!
DEPARTMENT
(SEWER MAIN TO PROPERTY LINE) "
W (SEE NOTE 7) --� f- LIMITS OF PIPE ZONE
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 5) O.D. OF PIPE
FOUNDATION LEVEL
6"
BEDDING FOR SANITARY SEWER PIPE
NOTES:
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE
STANDARD SPECIFICATIONS.
5. PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3)'
OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL.
6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
7. TRENCH WID-H SHALL BE PER SECTION 2-09.4 OF THE
STANDARD SPECIFICATIONS.
STD. PLAN - 405
PUBLIC WORKS PIPE BEDDING
DEPARTMENT FOR SANITARY SEWERS
7' 1
B,
T-
NOT TO SCALE
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR JOINT(S) (3/8" MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX. PIPE SIZE - 'E'
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
'A'
'B'
'C'
I 'D'
I 'E'
48" MH
48"
6" MIN.
5"MIN
24" MIN.
21" I.D.
54" MH
54"
8" MIN.
5.5" MIN.
24" MIN.
24" I.D.
6C" MH
60"
8" MIN.
6" MIN.
42" MIN.
30" I.D.
NOTES:
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 401.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 112 BOND. THE USE OF SHIMS IS PROHIBITED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE.
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
`zY STD. PLAN - 400.1
PUBLIC WORKS STANDARD SANITARY MANHOLE
DEPARTMENT
FNT� SEPTEMBER 2011
WASgo��',� SURVEYED:
DESIGNED:
D.L. OFFE, P.E.
° DRAWN:
27460
CHECKED:
FSS/ O N A L � �'
12/14/2017 NO. REVISION BY DATE APPR APPROVED:
SCALE:
ONE INCH
AT FULL ---
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
SANITARY SEWER NOTES AND SPECIFICATIONS
1. All work and work material shall be in conformance with the standards and specifications
of the City of Renton Planning/Building/Public Works Department and the latest edition
of the WSDOT/APWA Standards and Specifications, as approved and modified by the
City of Renton in the Renton Standard Plans & Specifications. A set of approved plans
shall be kept on site at all times during construction.
2. The hours of work in the street right of way shall be per City specifications on weekdays
unless otherwise approved in writing by the Planning/Building/Public Works Department.
An approved traffic control plan must be obtained prior to beginning any work within
public right of way.
3. All locations of existing utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to avoid damage or
disturbance.
4. A pre -construction conference and a 24 hour notice shall be required prior to starting
new construction. It shall be the contractor's responsibility to secure all necessary
permits prior to starting construction. (Inspection will be accomplished by a
representative of the City of Renton.) It shall be the contractor's responsibility to notify
the Public Works inspector 24 hours in advance of backfilling all construction.
5. Contractor is solely responsible for the means, methods and sequences of construction
and for the safety of workers and others on the construction site.
6. It shall be the responsibility of the contractor to obtain street use and any other related
permits prior to any construction.
7. Plans approved by the City of Renton, Public Works Department shall take precedence
over all other plans.
8. A copy of these approved plans must be on the job site whenever construction is in
progress.
9. The contractor shall provide the City of Renton with an as -built drawing of the sanitary
sewer system, which has been stamped and signed by a licensed professional engineer
or licensed professional surveyor.
10. Backfill shall be placed equally on both sides of the pipe in layers with a loose average
depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95
percent of maximum density. These compacted layers must extend for one pipe
diameter on each side of the pipe or to the side of the trench. Materials to complete the
fill over pipe shall be the same as described.
11. Open cut road crossings for utility trenches on existing traveled roadway shall be
backfilled with crushed rock and mechanically compacted unless otherwise approved by
12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department. Reference benchmark and
elevations are noted on the plans.
13. All disturbed areas shall be seeded and mulched or otherwise stabilized to the
satisfaction of the Department for the prevention of on -site erosion after the completion
of construction.
14. All pipe and appurtenances shall be laid on a properly prepared foundation in
accordance with the standards and specifications of the City of Renton
Planning/Building/Public Works Department and the latest edition of the WSDOT/APWA
Standards and Specifications, as approved and modified by the City of Renton in the
Renton Standard Plans & Specifications. This shall include necessary leveling of the
trench bottom or the top of the foundation material, as well as placement and
compaction of required bedding material, to uniform grade so that the entire length of
the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be
pea gravel 6 inches above and below the pipe.
15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034,
SDR 35, or ductile iron class 50, unless otherwise approved by the Wastewater Utility.
16. In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches
above finished grade or must have minimum 2' diameter concrete ring poured at grade
In paved area, cover must slope in all directions to match paving.
CITY OF
R
RENTON
vassv_
Planning/Building/Public Works Dept.
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
WASTEWATER UTILITY:0.%]
DEVELOPMENT ENGINEERINGdchristen 12/14/2017rnair 12/14/2017
DATE:
559 HOQUTAM SEWER EXTENSION 122/14/2017
TUSCANY CONSTRUCTION, LLC (
PAGE:
WASTEWATER DETAILS & NOTES DRAWING NO:
559 HOQUTAM AVENUE NE
RENTON, WASHINGTON SHEET,. 2 OF: 3
0')
00
co
LO
O
T
,
u
H
H
S-398602