HomeMy WebLinkAboutP_Lighting consultant -260307_EL0.10.14 0.15 0.16 0.18 0.21 0.23 0.25 0.27 0.28 0.30 0.31 0.31 0.31 0.26 0.18 0.19 0.22 0.24 0.27 0.29 0.31 0.33 0.35 0.36 0.37 0.37 0.63 0.28 0.23 0.25 0.27 0.30 0.33 0.36 0.38 0.41 0.42 0.43 0.44 0.27 0.31 0.34 0.37 0.41 0.44 0.47 0.49 0.51 0.51 0.51 0.50 0.49 0.46 0.30 0.33 0.37 0.41 0.46 0.50 0.53 0.56 0.58 0.59 0.59 0.58 0.56 0.53 0.32 0.36 0.40 0.45 0.50 0.56 0.60 0.64 0.66 0.67 0.67 0.66 0.63 0.59 0.33 0.38 0.43 0.48 0.54 0.61 0.67 0.71 0.74 0.76 0.76 0.74 0.70 0.66 0.31 0.35 0.38 0.45 0.52 0.58 0.65 0.72 0.77 0.82 0.84 0.84 0.81 0.76 0.71 0.32 0.36 0.41 0.47 0.54 0.62 0.69 0.76 0.82 0.88 0.91 0.91 0.87 0.81 0.74 0.32 0.36 0.42 0.48 0.56 0.64 0.73 0.80 0.87 0.92 0.95 0.95 0.91 0.84 0.77 0.23 0.28 0.32 0.37 0.43 0.50 0.57 0.66 0.74 0.82 0.89 0.96 0.23 0.27 0.33 0.38 0.43 0.50 0.58 0.66 0.75 0.82 0.89 0.95 0.99 0.98 0.94 0.87 0.80 0.66 0.74 0.81 0.87 0.93 0.96 0.95 0.91 0.85 0.78 0.65 0.72 0.79 0.84 0.88 0.91 0.90 0.87 0.81 0.75 0.63 0.69 0.75 0.80 0.82 0.84 0.83 0.81 0.77 0.71 0.61 0.66 0.71 0.75 0.77 0.77 0.77 0.75 0.71 0.66 0.59 0.63 0.67 0.69 0.71 0.71 0.70 0.69 0.66 0.61 0.56 0.60 0.62 0.65 0.66 0.66 0.65 0.63 0.60 0.56 0.54 0.56 0.59 0.60 0.61 0.60 0.59 0.58 0.55 0.52 0.52 0.54 0.56 0.56 0.57 0.56 0.55 0.53 0.51 0.48 0.51 0.52 0.53 0.54 0.53 0.53 0.51 0.49 0.47 0.44 0.50 0.51 0.52 0.52 0.51 0.50 0.48 0.46 0.44 0.41 0.50 0.52 0.52 0.51 0.50 0.48 0.46 0.44 0.41 0.38 0.51 0.52 0.52 0.52 0.50 0.47 0.44 0.41 0.38 0.35 0.52 0.53 0.53 0.52 0.50 0.46 0.43 0.39 0.36 0.32 0.53 0.54 0.53 0.52 0.49 0.45 0.41 0.38 0.34 0.30 0.56 0.56 0.55 0.51 0.48 0.44 0.40 0.36 0.32 0.28 0.56 0.57 0.55 0.51 0.47 0.43 0.39 0.34 0.30 0.26 0.55 0.55 0.53 0.49 0.45 0.41 0.37 0.32 0.28 0.25 0.50 0.50 0.50 0.46 0.43 0.39 0.35 0.31 0.27 0.23 0.45 0.45 0.44 0.43 0.40 0.37 0.33 0.29 0.25 0.22 0.41 0.41 0.41 0.39 0.37 0.33 0.30 0.27 0.24 0.21 0.37 0.37 0.36 0.35 0.33 0.30 0.27 0.24 0.22 0.19 0.32 0.32 0.32 0.30 0.29 0.27 0.25 0.22 0.20 0.18 0.27 0.27 0.27 0.26 0.25 0.24 0.22 0.20 0.18 0.16 1.80 2.73 3.93 4.87 5.69 5.76 5.07 4.11 2.95 2.01 1.88 2.90 4.07 5.23 6.16 6.24 5.39 4.24 3.14 2.09 DPH JCM Drawn By Sheet Number Sheet Number Of Checked By All material herein constitutes the original and unpublished work of Tres West Engineers and may not be used, duplicated or disclosed without the written consent of the Tres West. Copyright © 2024 by Tres West Engineers, Inc. All rights reserved. KEYPLAN 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com Sheet Title Issue & Revision Dates Final Set4/14/2026 260307 Project Title Project Numbers 11410 SE Petrovitky Rd Renton, WA 98055 BO DE TEMPLE - PARKING LOT LIGHTING FINAL SET 1 SCALE: SITE PLAN 1"=20'-0"SCALE: PHOTOMETRIC PLAN 1"=20'-0" EL0.1 Site & Photometric Plans 1 PROPERTY LINE = 165.97' PR O P E R T Y L I N E = 2 3 0 . 0 ' PR O P E R T Y L I N E = 2 3 0 . 0 ' AREA OF WORK (STRUCTURE) SE 176TH ST LANDSCAPE EXIST LIVING QUARTERS LOWER DECK x x x x x x x x x SD S D SD SD S D OH P OH P OH P OH P OH P OH P GARDEN AREA (APPROX. LOCATION RELOCATED EXISTING STATUE LOCATION (VERIFY) SIDEWALK SIDEWALK TEMP. CONSTR. OFFICE 5 4 3 2 GA R B A G E T R U C K GA R B A G E T R U C K GARBAGE TRUCK CONC. WALKWAY RELOCATED STONE SIGNAGE (E) RAMP DN (E ) P O R C H DN UPPER DECK DECK 8 7 6 9 10 1 UPLIGHTING WALL LIGHTING, SEE ELEVATIONS, TYP OF 5 UPLIGHTING L1 L2 L2 L2 L2 L2 L4 L4 L3 PLAN NOTES 001 LIGHT FIXTURE TYPE L1. PROVIDE CONCRETE FOOTING. SEE DETAIL BELOW. LIGHT FIXTURE TYPE L2. SEE ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS. LIGHT FIXTURE TYPES L5 AND L6, TYPICAL. ORIENT TO LIGHT FACE OF STATUE. LOCATE CENTER OF FIXTURES 30" FROM STATUE BASE AND 48" ON CENTER EACH SIDE. PROVIDE CONCRETE BASE TO SUPPORT FIXTURE. TOP OF FIXTURE FLUSH WITH GRADE. FINAL AIMING SETPOINTS TO BE SET DURING LIGHTING MOCKUP, PRIOR TO FIXTURE INSTALLATION. LIGHT FIXTURE TYPE L4. ORIENT TO LIGHT FACE OF MONUMENT. LOCATE CENTER OF FIXTURES 24" FROM FACE OF MONUMENT AND 48" ON CENTER. PROVIDE CONCRETE BASE TO SUPPORT FIXTURES. TOP OF FIXTURES FLUSH WITH GRADE. LIGHT FIXTURE TYPE L3. PROVIDE CONCRETE FOOTING. SEE DETAIL BELOW. ### Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Parking Area Illuminance Fc 0.51 0.99 0.14 3.64 7.07 Ramp Illuminance Fc 4.01 6.24 1.80 2.23 3.47 005 002 003 004 005 001 002 002002 002 002 003 004 004 PARKING AREA CALCULATION POINTS MONUMENT CALCULATION POINTS STATUE CALCULATION POINTS RAMP CALCULATION POINTS 48"L. 3/4"DIA. ANCHOR BOLTS (TYP. OF 4) FINISHED GRADE 24"ROUND PRE-CAST CONCRETE LIGHT POLE BASE CAULK ALL AROUND 2" GROUT GROUND WIRE TO LIGHT FIXTURE POLE BASE COVER, SECURE TO BASE #3 TIE BAR AROUND BOLTS AT 12"O.C. (TYP. OF 3 PLACES) TYPICAL LIGHTING CIRCUIT CONDUIT 4 #5 VERTICAL SET AND COMPACT AGAINST NATIVE EARTH 2 #3 TIE AT TOP CONDUIT PER CIRCUIT CONDUIT BUSHING GROUND LUG TO POLE HANDHOLE/COVER LIGHT POLE, SEE LIGHTING FIXTURE SCHEDULE 5'- 0 " 2" SCALE: NONE CONCRETE FOOTING DETAIL FOR FIXTURE TYPE ('TYPE L1 & L3') 1.PROVIDE A LIGHTING CONTROL PANEL IN BUILDING NEXT TO ELECTRICAL PANEL. LIGHTING CONTROL PANEL TO BE PROGRAMMED TO MEET WASHINGTON STATE ENERGY CODE REQUIREMENTS FOR CONTROL OF ALL EXTERIOR LIGHTING. COORDINATE PROGRAMMING AND SCHEDULES WITH OWNER. 2.PROVIDE 1" CONDUIT WITH 2#10 AND 1#10 GROUND FOR LIGHTING CIRCUITS. GENERAL NOTES L6L5 Calculation Summary Label CalcType Units Avg Max Min Max/Min Monument_Side_2 Illuminance Fc 4.29 7.8 2.5 3.12 Calculation Summary Label CalcType Units Avg Max Min Max/Min statue_Side_1 Illuminance Fc 6.68 11.4 3.0 3.80 statue_Side_10 Illuminance Fc 6.70 10.1 3.1 3.26 statue_Side_11 Illuminance Fc 7.42 10.7 3.3 3.24 statue_Side_12 Illuminance Fc 7.13 11.1 3.2 3.47 statue_Side_13 Illuminance Fc 6.48 11.7 2.9 4.03 statue_Side_14 Illuminance Fc 6.42 11.6 3.3 3.52 statue_Side_15 Illuminance Fc 6.25 10.0 3.1 3.23 statue_Side_16 Illuminance Fc 6.98 10.0 2.8 3.57 statue_Side_17 Illuminance Fc 7.93 11.3 2.9 3.90 statue_Side_18 Illuminance Fc 7.45 11.6 2.7 4.30 statue_Side_19 Illuminance Fc 6.80 12.2 2.7 4.52 statue_Side_2 Illuminance Fc 6.50 11.5 3.6 3.19 statue_Side_20 Illuminance Fc 6.30 12.0 3.0 4.00 statue_Side_21 Illuminance Fc 5.63 10.5 2.4 4.38 statue_Side_22 Illuminance Fc 6.60 10.5 3.0 3.50 statue_Side_23 Illuminance Fc 7.38 10.7 3.3 3.24 statue_Side_24 Illuminance Fc 7.20 10.9 3.3 3.30 statue_Side_3 Illuminance Fc 6.23 10.0 3.4 2.94 statue_Side_4 Illuminance Fc 7.08 10.6 3.1 3.42 statue_Side_5 Illuminance Fc 7.87 11.4 3.2 3.56 statue_Side_6 Illuminance Fc 7.53 11.8 3.1 3.81 statue_Side_7 Illuminance Fc 6.67 11.9 2.7 4.41 statue_Side_8 Illuminance Fc 6.33 11.8 3.3 3.58 statue_Side_9 Illuminance Fc 5.90 10.1 3.2 3.16 L5 L6 L6 L5 L5L6 NOTE: A MULTI-SIDED OBJECT (HENCE THE NUMEROUS SIDE CALCULATIONS REPRESENTED ABOVE) WAS CREATED TO SIMULATE THE STATUE HEIGHT AN DIAMETER DIMENSIONS TO OBTAIN OPTIMUM AVERAGE LIGHT LEVELS AND UNIFORMITY RATIOS SHOWN IN THE TABLE.