HomeMy WebLinkAboutApproved Civil PlanAPN 3123059092 PMT PMT P CO S S T T T CB CBCB CB W P P P 28" 16" 32" 16" 24 24 23 24 23 23 24 22 23 24 23 23 23 24 2 3 24 24 24 23 25 25 25 25 25 25 25 25 25 S S 24 PIV 1-1/2" WATER METER MTR-007502 1" IRRIGATION METER MTR-007503 FDC W PIV W P EXISTING BUILDING PROJECT SITE Know what's below. before you dig.Call R NORTH 3900 EAST VALLEY ROADOWNER / APPLICANT MIDDLE TREE PROPERTIES LLC 601 S CARR RD, SUITE 300RENTON, WA 98055 CIVIL ENGINEER MOMENTUM CIVIL 1145 BROADWAY, SUITE 115TACOMA, WA 98402 CONTACT: MARC PUDISTS, P.E. EMAIL: MARCP@MOMENTUMCIVIL.COM PHONE: (253) 319-1505 CONTACT: TAYLOR BALIAN, P.E. EMAIL: TAYLORB@MOMENTUMCIVIL.COMPHONE: (406) 624-9115 SURVEYOR ARCHITECT UTILITY PURVEYORS / SERVICES STORM:CITY OF RENTON 1055 SOUTH GRADY WAYRENTON, WA 98057 EMAIL: JFARAH@RENTONWA.GOV PHONE: 425-430-7248 SEWER:CITY OF RENTON 1055 SOUTH GRADY WAYRENTON, WA 98057 EMAIL: JSTOWELL@RENTONWA.GOV PHONE: 425-430-7212 WATER:KING COUNTY WATER DISTRICT #9015606 SE 128TH STREET RENTON, WA 98059 EMAIL: INFO@KCWD90.COMPHONE: 425-255-9600 FIRE:RENTON REGIONAL FIRE AUTHORITY] 18002 108TH AVE SERENTON, WA 98055 PHONE: 425-276-9500 POWER:PUGET SOUND ENERGY PO BOX 91269BELLEVUE, WA 98009 EMAIL: CUSTOMERCARE@PSE.COM PHONE: 1-888-225-5773 GAS:PUGET SOUND ENERGY PO BOX 91269BELLEVUE, WA 98009 EMAIL: CUSTOMERCARE@PSE.COM PHONE: 1-888-225-5773 VICINITY MAP GENERAL NOTES 1.CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL PLAN TO THE CITY OF RENTON PUBLICWORKS FOR REVIEW AND OBTAIN APPROVAL PRIOR TO ANY WORK WITHIN THE RIGHT-OF-WAY. MOMENTUM CIVIL ASSUMES NO RESPONSIBILITY FOR TRAFFIC CONTROL. 2.ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE CITY OF RENTON STANDARDS. IFCITY OF RENTON STANDARDS DO NOT ADDRESS A PROJECT ELEMENT, THEN THE LATEST VERSION OF THE WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION SHALLY APPLY UNLESS SUPERSEDED BY THIS PLAN SET, OR AN ORDER OF THEENGINEER OR OWNER. 3.CONTRACTOR TO INSTALL IRRIGATION SLEEVING AND ELECTRICAL AND LIGHTING CONDUIT BASED ON LANDSCAPE AND ELECTRICAL/LIGHTING PLANS, RESPECTIVELY. INFORMED LAND SURVEY PO BOX 5137 TACOMA, WA 98415-0137 CONTACT: EVAN WAHLSTROM, P.L.S. EMAIL: ADMIN@I-LANDSURVEY.COM PHONE: 253-627-2070 SITE INFORMATION PARCEL NUMBER(S): 3123059092 PROJECT ADDRESS: 3900 EAST VALLEY ROAD, RENTON, WA 98057PARCEL AREA: 50,971 SF DEVELOPMENT TEAM FILL SPECIFICATION FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR ANY KNOWN SUBSTANCES THATARE TOXIC, HAZARDOUS, DANGEROUS, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE CODE, REGULATION RULE, ORDER, OR STANDARD OF AN AGENCY HAVING JURISDICTION . ALL FILL MATERIAL SHALL BE EARTHEN, BE CAPABLE OF COMPACTION INCOMPLIANCE WITH ASTM D1557, AND BE IN COMPLIANCE WITH THE PROJECT-SPECIFIC GEOTECHNICAL RECOMMENDATIONS. POST-CONSTRUCTION SOIL QUALITY AND DEPTH ALL DISTURBED SOILS THAT ARE TO REMAIN VEGETATED IN THE POST-DEVELOPED CONDITION SHALL BE AMENDED IN-PLACE TO COMPLY WITH DEPARTMENT OF ECOLOGY BEST MANAGEMENT PRACTICE (BMP) T5.13 EXISTING CONDITIONS VERIFICATION PRIOR TO ANY EXCAVATION ACTIVITIES, THE CONTRACTOR SHALL VERIFY THE LOCATIONS AND DEPTHS OF UNDERGROUND UTILITIES TO IDENTIFY ANY POTENTIAL CONFLICTS WITH PROPOSED CONSTRUCTION. CONTACT PROJECT ENGINEER IF ANY CONFLICTS ARE IDENTIFIED. EXISTINGUTILITIES SHALL BE POTHOLED AT THE LOCATION WHERE NEW CONNECTIONS ARE PROPOSED TO VERIFY INVERTS, MATERIALS, SIZE, AND GENERAL CONFORMANCE WITH THESE PLANS. CONTACTPROJECT ENGINEER IF CONDITIONS ARE DIFFERENT THAN ANTICIPATED. PRIOR TO ANY CONSTRUCTION ACTIVITIES, VERIFY EXISTING TOPOGRAPHY AND GENERAL SITEFEATURES ARE CONSISTENT WITH THESE PLANS AND IF THERE ARE ANY POTENTIAL CONFLICTS WITH PROPOSED IMPROVEMENTS. CONTACT PROJECT ENGINEER IF ANY CONFLICTS ARE IDENTIFIED. TRENCH SAFETY IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR (4) OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETYAND MOMENTUM CIVIL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. ELECTRONIC FILE RELEASE AN AUTOCAD (DWG) DRAWING FILE OF THE PLANS WILL BE MADE AVAILABLE TO THE CONTRACTOR UPON REQUEST. PLEASE BE AWARE THAT ELECTRONIC FILES ARE FURNISHEDSOLELY FOR CONTRACTOR'S CONVENIENCE AND SHALL NOT REPLACE NOR BE USED TO SUBSTITUTE THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING THE IMPROVEMENTS ACCORDING TO THE CONTRACT DOCUMENTS. MAGELLAN ARCHITECTS 8383 158TH AVENUE NE, SUITE 280 REDMOND, WASHINGTON 98052 CONTACT: JAMIE TRENDA EMAIL: JAMIE@MAGELLANARCHITECTS.COM PHONE: (425) 885-4300 FIRE LINE AND WATER SERVICES PROPOSED SURFACE COVERAGE SUMMARY ONSITE OFFSITE TOTAL SURFACE DESCRIPTION (SQ. FT)(ACRE)(SQ. FT)(ACRE)(SQ. FT)(ACRE) NEW + REPLACED PGIS 304 0.007 0 0.000 304 0.007 NEW + REPLACED NON PGIS 38 0.001 0 0.000 38 0.001 LANDSCAPING 432 0.010 90 0.002 522 0.012 TOTAL DISTURBED AREA 774 0.018 90 0.002 864 0.020 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC COVER SHEET 1 CIVIL SHEET INDEX Pg #Ref #Sheet Title 1 C1.0 COVER SHEET 2 SV1.1 SURVEY 3 C2.0 TESC AND DEMOLITION PLAN 4 C2.1 TESC DETAILS 5 C3.0 SITE AND UTILITY PLAN 6 C3.1 WATER DETAILS 7 C3.2 WATER DETAILS 8 C3.3 WATER DETAILS 9 C3.4 WATER DETAILS 10 C3.5 WATER UTILITY NOTES AND SPECIFICATIONS E V A L L E Y H W Y WATER UTILITY ABDOUL GAFOUR 06/16/2026 WT R - 2 7 - 4 4 2 0 W-442001 REGIONAL FIRE AUTHORITY cthomas 07/06/2026 APPROVED DEVELOPMENT ENGINEERING HHuynh 07/21/2026 WT R - 2 7 - 4 4 2 0 W-442002 APN 3123059092 PMT P CO S T T T CB CBCB P P 16" 32" 417.69'(R1)S89°03'22"E S0 0 ° 4 3 ' 4 6 " W E V A L L E Y H W Y 15 9 . 7 7 ' S1 7 ° 4 9 ' 5 7 " W N81°12'06" W 2349.10'(M) HOTBOX 24 24 23 23 24 2 3 24 2 4 24 23 25 2 5 25 25 25 25 25 25 S SEWER MANHOLE RIM EL=22.44' SW/E 12" CONC IE=10.94' @ CENTER OF STRUCT. LADDER E SEWER MANHOLE RIM EL=22.31' N/S 12" CONC W 8" CONC IE=11.41' @ CENTER OF STRUCT. LADDER S PIV29.50'5.50' (R2) 256.57' S0 1 ° 4 9 ' 3 7 " W 24 8 . 6 3 ' 1-1/2" WATER METER MTR-007502 1" IRRIGATION METER MTR-007503 INLET PROTECTION INLET PROTECTION SF LIMIT LIMIT LIMIT LIMIT LIMIT LIMIT LI M I T LI M I T SF 1 1 2 2 3 TESC AND DEMOLITION LEGEND PROPERTY LINE LIMIT OF CONSTRUCTION FULL DEPTH PAVEMENT SAWCUT LINE PER BMP C152 SILT FENCE PER BMP C233 HMA PAVEMENT REMOVAL CONCRETE SIDEWALK REMOVAL STORM DRAINAGE INLET PROTECTION PER BMP C220 EG MAJOR CONTOUR EG MINOR CONTOUR LIMIT SF INLET PROTECTION 100 101 C2.1 214.00 C2.1 216.30 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC TESC AND DEMOLITION PLAN 3 NORTH ( FEET ) 20 20 40100 TESC AND DEMOLITION KEYNOTES INSTALL CATCH BASIN INSERT PER DETAIL 216.30 ON SHEET C2.1 FULL DEPTH PAVEMENT SAWCUT AND REMOVAL, INCLUDING EXTRUDED CURB LOCATED ON PAVEMENT REMOVAL AREAS. EXISTING RPBA TO BE REMOVED AND REPLACED WITH 2" RPBA. 1 2 3 WT R - 2 7 - 4 4 2 0 W-442003 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC TESC DETAILS 4 WT R - 2 7 - 4 4 2 0 W-442004 APN 3123059092 PMT P CO S T T T CB CBCB P P CATCH BASIN RIM EL=23.28' NW 8" PVC IE=18.13' @ TOP OF OVERFLOW=21.83' E 8" PVC IE=18.38' SE 4" PVC IE=19.28' S 8" PVC IE=17.98' CATCH BASIN RIM EL=22.75' W 8" PVC IE=19.25' 16" 32" 417.69'(R1)S89°03'22"E S0 0 ° 4 3 ' 4 6 " W E V A L L E Y H W Y 15 9 . 7 7 ' S1 7 ° 4 9 ' 5 7 " W N81°12'06" W 2349.10'(M) 24 24 23 23 24 2 3 24 2 4 24 23 25 2 5 25 25 25 25 25 25 S STORM DRAIN MANHOLE RIM EL=23.00' N 16" CONC IE=14.80' E 24" CMP IE=16.50' S 16" CONC IE=14.80' LADDER W SEWER MANHOLE RIM EL=22.44' SW/E 12" CONC IE=10.94' @ CENTER OF STRUCT. LADDER E CATCH BASIN RIM EL=21.53' E//W 12" CONC IE=19.23 SEWER MANHOLE RIM EL=22.31' N/S 12" CONC W 8" CONC IE=11.41' @ CENTER OF STRUCT. LADDER S CATCH BASIN RIM EL=22.01' W 12" CONC IE=19.91' FOUND MAG-NAIL STEM (NO HEAD OR WASHER) ON LINE, 0.5' W N 1/4 COR SEC 31, T23N, R5E, W.M. FOUND CASED MON 2" BRASS WITH "X" PIV29.50'5.50' (R2) APPROX. ROW LINE, ADDITIONAL RECORDS NEEDED TO DETERMINE EXACT LOCATION 256.57' S0 1 ° 4 9 ' 3 7 " W 24 8 . 6 3 ' 1-1/2" WATER METER MTR-007502 1" IRRIGATION METER MTR-007503 FDC W W PIV W W P P 2 3 4 5 6 1 0+ 0 0 1+ 0 0 1+ 2 5 STA: 0+10.00; 0.00' RIM: 25.08 T/P ELEV: 21.94 8" X 6" TAPPING TEE W/ TB (FL) (ROLL 5°±) 6" GATE VALVE WITH VALVE BOX (FL X MJ) STA: 0+20.28; 0.00' RIM: 25.21 T/P ELEV: 21.09 6" 90° BEND W/ TB (MJ) (ROLL 5°±) T/P ELEV: 21.09 STA: 0+34.33; 0.00' POST INDICATOR VALVE (FL) T/P ELEV: 21.09 STA: 0+36.38; 0.00' 6" 90° BEND W/ TB (FL) T/P ELEV: 21.09 T/P ELEV: 21.09 STA: 0+38.75; 0.00' 6" TEE W/ TB (FL) 6" ADAPTER (FL X MJ) STA: 1+01.02; 0.00' T/P ELEV: 21.09 6" FIRE SERVICE CONNECTION EXISTING FIRE HYDRANT HYD-SW-00222 C3.1 300.6 C3.1 330.1 C3.1 330.1 C3.1 330.1 C3.1 330.1 STA: 0+28.90; 1.19' R RIM: 25.70 DCDA VAULT, OLDCASTLE 675-WA C3.2 350.3 C3.1 330.7 7 8 8 9 9 10 11 12 0 C3.3 370.3 C3.3 1 46.05' 13 14 15 15 C3.1 300.5 1617 8.0 0 ' EXISTING BUILDING CIVIL LEGEND EXISTING BUILDING FOOTPRINT PROPERTY BOUNDARY EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR WATER SERVICE LINE FIRE DEPARTMENT CONNECTION/POST INDICATOR VALVE/METER/FITTINGS NEW HMA PAVEMENT LANDSCAPING 19 20 W W 19 20 FDC PIV Horz. Scale: 1" = 20' | Vert. Scale: 1" = 5' FIRE LINE (STA: 0+00 TO 1+25) 10 12.5 15.0 17.5 20 22.5 25.0 27.5 30 10 12.5 15.0 17.5 20 22.5 25.0 27.5 30 0+00 1+00 1+25 EG 2 5 . 2 ± FG 2 5 . 7 3 EG 2 5 . 2 ± FG 2 5 . 6 1 EG 2 5 . 1 ± FG EG ± FG STA: 0+28.90; 1.19' R RIM: 25.70 DCDA VAULT, OLDCASTLE 675-WA EXIST. STORM 8" DIA STA: 0+62.84 CROWN: 19.52' 12 " M I N . EXIST. WATER 8" DIA STA: 0+10.00 ASSUMED 36" DEPTH (VERIFY) EXIST. WATER 8" DIA STA: 0+46.15 ASSUMED 36" DEPTH (VERIFY) T/P ELEV: 21.09 STA: 0+20.28; 0.00' 6" 90° BEND W/ TB (MJ) (ROLL 5°±) T/P ELEV: 21.09 STA: 0+34.33; 0.00' POST INDICATOR VALVE (FL) T/P ELEV: 21.09 STA: 0+36.38; 0.00' 6" 90° BEND W/ TB (FL) T/P ELEV: 21.09 STA: 0+38.75; 0.00' 6" TEE W/ TB (FL) 6" ADAPTER (FL X MJ) STA: 1+01.02; 0.00'6" FIRE SERVICE CONNECTION FINISHED GRADE @ PIPE CENTERLINE EXISTING GRADE @ PIPE CENTERLINE FINISHED GRADE @ PIPE CENTERLINE EXISTING GRADE @ PIPE CENTERLINE PROVIDE 0.25' THICK, 3' X 3' ETHAFOAM PAD AT PIPE CROSSING STA: 0+10.00; 0.00' T/P ELEV: 21.94 8" X 6" TAPPING TEE W/ TB (FL) (ROLL 5°±) 6" GATE VALVE WITH VALVE BOX (FL X MJ) C3.1 300.6 C3.1 330.1 C3.1 330.7 C3.2 350.3 C3.3 370.3 C3.1 330.1 C3.1 330.1 C3.3 1 POWER STA: 0+12.26 ASSUMED 30" DEPTH (VERIFY) POWER STA: 0+43.74 ASSUMED 30" DEPTH (VERIFY) C3.1 330.1 C3.1 300.5 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC SITE AND UTILITY PLAN 5 NORTH ( FEET ) 20 20 40100 CIVIL KEYNOTES CONTRACTOR MUST POTHOLE AND SURVEY THE LOCATIONS OF EXISTING POWER AND WATER LINES AND CONTACT ENGINEER PRIOR TO ORDERING VAULTS, AS VAULT DEPTH MAY NEED TO BE REVISED TO ALLOW NEW WATER LINE TO AVOID POTENTIAL CONFLICTS WITH POWER AND EXISTING WATER. NEW 2" REDUCED PRESSURE BACKFLOW ASSEMBLY PER DETAIL 360.1 ON SHEET C3.3. CONNECT TO EXISTING 1-1/2" METER AND USE EXISTING ELECTRICAL SERVICE. NEW DOMESTIC WATER SERVICE. INSTALL 70 LF OF 2" POLY WATER LINE FROM NEW 2" REDUCED PRESSURE BACKFLOW ASSEMBLY TO EXISTING BUILDING PENETRATION. NEW 6" DIP FIRE LINE. INSTALL CONCRETE BLOCKING AT ALL BENDS AND TEES PER DETAIL 330.1 ON SHEET C3.1. NEW 6" DOUBLE CHECK DETECTOR ASSEMBLY (DCDA) AND VAULT PER DETAIL 350.3 ON SHEET C3.2. INSTALL FIRE DEPARTMENT CONNECTION THROUGH DCDA VAULT PER DETAIL 370.3 ON SHEET C3.3. INSTALL CONCRETE BLOCKING ADJACENT TO VAULT PER DETAIL 370.4 ON SHEET C3.4. INSTALL VAULT LADDER PER DETAIL 370.5 ON SHEET C3.4. PROVIDE 20 AMP SERVICE AND 1/3 HP SUMP PUMP WITH INTEGRAL FLOAT SWITCH WITH 1" PVC DISCHARGING THROUGH CURB ONTO ASPHALT. INSTALL POWER IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL ELECTRIC CODES. NEW 6" FIRE DEPARTMENT CONNECTION (FDC) PER DETAIL 1 ON SHEET C3.3. INSTALL FDC THROUGH DCDA VAULT PER DETAIL 370.3 ON SHEET C3.3. INSTALL NEW 1" DOUBLE CHECK VALVE ASSEMBLY ON EXISTING IRRIGATION SERVICE PER DETAIL 340.8 ON SHEET C3.2. CONNECT TO EXISTING SUPPLY LINE AND IRRIGATION SYSTEM. INSTALL NEW 6" EXTRUDED CURB MATCHING EXISTING CURB PROFILE. PROVIDE 1-FOOT GAP IN CURB FOR DRAINAGE AND GRADE NEW LANDSCAPE AREA TO DRAIN. REPLACE PAVEMENT, MATCHING EXISTING PAVEMENT SECTION. REPLACE CEMENT CONCRETE SIDEWALK, MATCHING EXISTING SIDEWALK SECTION. EXTEND CONCRETE PAVEMENT IN FRONT OF NEW DOOR AND PROVIDE NEW PLANTER BOX CURB PER ARCHITECTURAL DRAWINGS. RESTORE LANDSCAPING. REPLACE EXTRUDED CURB AND RESTORE LANDSCAPING. REPLACE ALL PAVEMENT MARKINGS DISTURBED DURING CONSTRUCTION. INSTALL 1" PVC DISCHARGE LINE FOR DCDA VAULT SUMP PUMP. LINE SHALL DISCHARGE THROUGH CURB ONTO ASPHALT. PROVIDE 20 AMP ELECTRICAL SERVICE FROM BUILDING TO DCDA VAULT FOR SUMP PUMP. INSTALL POWER IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL ELECTRIC CODES. CONTRACTOR TO POTHOLE PRIOR TO CONSTRUCTION TO VERIFY WHETHER THERE IS AN EXISTING STORMWATER FACILITY AT THIS LOCATION. NOTIFY ENGINEER IN CASE OF ANY CONFLICTS WITH PROPOSED CONSTRUCTION. PROVIDE 5' MIN. SPACING FROM POWER VAULT TO BACK OF CONCRETE BLOCKING. APPROXIMATE LOCATION OF EXISTING 8" GATE VALVE PER RECORD DRAWING W-0580. INSTALL NEW 6" EXTRUDED CURB MATCHING EXISTING CURB PROFILE. GRADE NEW LANDSCAPE AREA TO DRAIN. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 NOTE: ONCE NEW BACKFLOW ASSEMBLIES ARE INSTALLED, A BACKFLOW TEST ASSEMBLY REPORT WITH A PASSING CONDITION IS REQUIRED FOR EACH DEVICE. EMAIL BACKFLOW@RENTONWA.GOV FOR NEW BACKFLOW ASSEMBLIES ONCE TEST REPORT IS COMPLETED.THE TEST REPORTS WILL NEED TO BE SUBMITTED PRIOR TO FINAL OCCUPANCY OF THE BUILDING. TESTING IS REQUIRED YEARLY. 18 XXXXXXXXXXX XXXXXXXXXXX WATER UTILITY ABDOUL GAFOUR 06/16/2026 WT R - 2 7 - 4 4 2 0 W-442005 DEVELOPMENT ENGINEERING HHuynh 07/21/2026 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC WATER DETAILS 6 WATER UTILITY ABDOUL GAFOUR 06/16/2026 WT R - 2 7 - 4 4 2 0 W-442006 DEVELOPMENT ENGINEERING HHuynh 07/21/2026 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC WATER DETAILS 7 SEE DETAIL 370.3 ON SHEET C3.3 FOR PLAN VIEW PROVIDE 1/3 HP SUMP PUMP WITH INTEGRAL FLOAT SWITCH WITH 1" PVC DISCHARGING THROUGH CURB ONTO ASPHALT. FLOW WATER UTILITY ABDOUL GAFOUR 06/16/2026 WT R - 2 7 - 4 4 2 0 W-442007 DEVELOPMENT ENGINEERING HHuynh 07/21/2026 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC WATER DETAILS 8 POST INDICATOR VALVE SCALE: NTS GATE VALVE TO BLDG DIP PIPE MATERIAL & FITTINGS AS PERSPECS EX. GRADE NOTE: PROVIDE TAMPER SWITCHES & CONNECT TOELECTRICAL SYSTEM POST INDICATOR OPEN EX. GRADE 24"x24"x8" CONC. BLOCK FIRE DEPT.CONNECTION 4' CABLE 1.ALL ABOVE GROUND PLUMBING TO BE PAINTED SAFETY RED. 2.ALL FIRE CONNECTION TO BE FLANGED, THREADED, VICTOLIC OR ROMA GRIPS. 3.FIRE DEPARTMENT CONNECTION (FDC) MUST BE CONNECTED DOWNSTREAM OF THE DOUBLE CHECK VALVE ASSEMBLY (DCVA) WHETHER DCVA IS INSTALLED INSIDE OF BLDG. OR OUTSIDE IN A VAULT. 4.THE FDC SHALL BE LOCATED WITHIN 15 FEET OF A FIRE HYDRANT, BUT NOT LESS THAN 10 FEET. 5.THE FREE-STANDING FDC SHALL BE A MINIMUM OF 50 FEET FROM THE BUILDING, UNLESS AN EXCEPTION IS MADE BY THE FIRE CODE OFFICIAL. 6.COORDINATE FDC LINE/FIRE LINE WITH BUILDING SPRINKLER PLANS. FDC LINE/FIRE LINE AND APPARATUS TO BE SIZED BY FIRE SPRINKLER DESIGNER. DIP FLANGED SPOOLTHREADED (GALVANIZED) IDENTIFICATION PLATECAST PIPE FROM DDCVA THRUST BLOCK PER AGENCY STANDARDS FIRE DEPARTMENT CONNECTION (FDC) SCALE: NTS TO METER 8" 4" AUTO SPRINKLER BLDG # 1.IDENTIFICATION PLATECAST WILL BE BRASS, 14" THICK, AND LETTERS WILL BE ONE INCH HIGH AND RAISED. 2.USE TWO (2) ZINC COATED U-BOLTS TO AFFIX TO PIPE. IDENTIFICATION PLATECAST NOTES INSTALL A 34" GRAVITY BALL DRIP AMERICAN FLOW OR APPROVED EQUAL AND A 34" BRASS 90° ELBOW BELOW THE FREEZE LINE, MINIMUM OF 12" COVER, IF DDCVA IS IN THE BUILDING AND/OR ABOVE THE FDC WRAP GALVANIZED PIPE WITH 3M TAPEOR EQUAL FROM FLANGE TO 6" ABOVE GROUND LEVEL IF BALL DRIP IS NEEDED, INSTALL 1-1/2" WASHED ROCK PER WSDOT STD SPEC. 9-03.12(5) TO AID DRAINAGE SINGLE STRAP FORD FS101 OR APPROVED EQUAL 6" F NPT x (2) 2-1/2 F NST FIRE DEPT INLET CONNECTION. CONFIRM WHETHER TWINCONNECTION OF SINGLE STORZ ADAPTOR TYPE WITH FIRE MARSHAL AND FIRE SPRINKLER DESIGNER. SCALE: NTS FIRE DEPARTMENT CONNECTION AND POST INDICATOR VALVE1PROVIDE 1/3 HP SUMP PUMP WITH INTEGRAL FLOAT SWITCH WITH 1" PVC DISCHARGING THROUGH CURB ONTO ASPHALT. WATER UTILITY ABDOUL GAFOUR 06/16/2026 WT R - 2 7 - 4 4 2 0 W-442008 DEVELOPMENT ENGINEERING HHuynh 07/21/2026 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC WATER DETAILS 9 WATER UTILITY ABDOUL GAFOUR 06/16/2026 WT R - 2 7 - 4 4 2 0 W-442009 DEVELOPMENT ENGINEERING HHuynh 07/21/2026 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS 3900 EAST VALLEY ROAD MIDDLE TREE PROPERTIES LLC WATER UTILITY NOTES AND SPECIFICATIONS 10 WATER UTILITY ABDOUL GAFOUR 06/16/2026 WT R - 2 7 - 4 4 2 0 W-442010 DEVELOPMENT ENGINEERING HHuynh 07/21/2026