HomeMy WebLinkAboutAPPROVED_SRTC_CCP_DC11_20260722GENERAL NOTES: 1.SEE BT120-CDD501-504 SHEETS FOR DRAINAGE DETAILS. 2.SEE BT120-CRY101-105 SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE BT120-CSP101-107 SHEETS FOR SITE PREPARATION PLANS. 4.SEE BT120-CPP101-107 SHEETS FOR PAVING PLANS. 5.SEE BT120-UCP101-205 SHEETS FOR EXISTING STORM STRUCTURES/PIPES REMOVAL, AND UTILITIES PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS. 8.USE WSDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. 9.PVC PIPE MATERIAL SHALL NOT BE USED FOR STORM SD PIPE SPANS WITH 3 FEET OF COVER OR LESS. 10.ALL STRUCTURES SHALL BE HS 20 LOAD RATED UNLESS OTHERWISE NOTED. SEE CDD DETAIL SHEETS FOR PROPRIETARY BMP LOADING CONSIDERATIONS DRAINAGE STRUCTURE TABLE STRUCTURE 102-17 102-18 FIL-3 MWS-66 STRUCTURE DETAILS CB TYPE 1L STA. 207+86.09 (1.36', RT) RIM 24.97 CB TYPE 2 - 48" STA. 309+06.83 (32.49', RT) RIM 25.34 TYPE C UNIT STA. 309+04.94 (37.11', RT) RIM 25.20 TYPE D UNIT STA. 207+85.05 (6.92', RT) RIM 25.55 PIPES IN IE 20.45 (W) IE 19.95 (S) IE 21.93 (NW) PIPES OUT IE 21.95 (SE) IE 19.95 (N) IE 20.61 (E) IE 21.41 (E) STA SEE BT120-CDD501 STA SEE BT120-CDD504 20 KEY NOTES: INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER (PRIVATE) PER COR STD PLAN 204.40. RIMS TO BE NON-SLIP WHEN LOCATED WITHIN WALKWAYS. REMOVE EXISTING OPEN CURB FACE FRAME AND GRATE AND INSTALL RECTANGULAR FRAME AND SOLID METAL COVER PER COR STD PLANS 204.00 AND 204.10, RESPECTIVELY. ADJUST RIM TO GRADE. INSTALL BIOFILTRATION SYSTEM TYPE D UNIT. SEE DWG. BT120-CDD504 FOR DETAILS AND SPECIAL PROVISIONS 7-05. INSTALL CATCH BASIN TYPE 1L PER COR STD PLAN 200.10, WITH OPEN CURB FACE FRAME AND GRATE PER COR STD PLAN 203.00. INSTALL BIOFILTRATION SYSTEM TYPE A UNIT. SEE DWG. BT120-CDD501 FOR DETAILS AND SPECIAL PROVISIONS. STRUCTURE FRAME AND COVER MEET AASHTO LOAD RATING HS-25. CONTRACTOR SHALL MATCH EXISTING PIPE CENTERLINE LOCATION AND INVERT ELEVATION(S) OF EXISTING CONNECTION(S). DISCREPANCIES BETWEEN PLAN LOCATION AND FIELD LOCATION SHALL BE REPORTED TO THE RESIDENT ENGINEER PRIOR TO STARTING CONSTRUCTION. 24 21 38 41 43 3 47 CONC CONC CONC SIGN DEBRIS SIGN SIGN SIGN / / / / CONC UT UT UT VLT VLT VLT VLT VLT HH VLTS VLT TRASHBIN TRASHBIN SW SW SW SW DRW DRW TRASHBIN SW SW SW DRW DRW SW SW DRW SW SW SW SW DRW CONC WALL TTTTMHGV GVGV GV GV 2 MISCMH GV GV TMH TMH GV GV GATE CW SW SW CONCBENCH 4' WOO D F N C CW SW CO N C B E N C H CONC BEN C H AR T W O R K CONC DRW DRW SW SW SW SW DRW DRW CO GV GV GV GV GV GM 2VLTS HH TTMH GM X6' CLEF 6' TEMP CLEF X 6' TEMP CLEF 6' TEMP CLEF 6' TEMPCLEF 8' CLEF X 5.5' CLEF SW 2' FNC GATE 6' CLE F 5.5' CLEF 6' CLEF BLDGEQUIP CONC SW SW SW SW SW SW SW SW CONC BASEREMOVED LT 4 BLRD 3 BLRD 3 BLRD 2 BLRD 6' TEM P C L E F 6' CLEF 2 BLRD 3 BLRD 6' TEM P C L E F SIGN POST ONCONC BASE 6' CLEF GATE STORAGESHED MISCVALV / // / SL SL SS CENTURYLINK CENTURY L I N K F O CENTURYLINK FO CENTURYLINK FO CENTURYLIN K F O CENTURYLINK FO CENTURYLINK FO CENTU R Y L I N K F O RENTONRENTON RENTON RENTON RENTO N RENTON RENT O N RENT O N RENTON RENTON RENTON RENTO NRENTON RENT O N RENTON RENTO NRENTO N WSDO T F O WSDO T F O 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAY O F O 2-ZAYO FO PSE GAS PSE G A S PSE GAS PSE G A S PSE GAS PSE GAS PSE GAS PSE GAS PSE GAS PSE GAS PSE G A S PSE G A S PSE GAS PSE GAS FOVLT HH GV 5'4" DP 6'8" DP 5' DP 4' DP4' DP 3' DP3'9" DP3'4" DP 2'11" DP 6'9" DP 1'DP 1'11" D P 2'3"DP 2' DP 2' DP3'11" DP 3'6" DP 5'9" DP 7'2" DP6'11" DP 7' DP 6'6" DP 4'4" DP 4'3" DP 3'7" DP 2' DP 4'10" DP 5'9" DP 4'7" DP 1'11" DP1'11" DP2'6" DP 5' DP1'4" DP 2'6" DP2'2" DP 3'1" DP2'6" DP 1'7" DP 1'9" DP 1'8" DP 1'6" DP 1'6" DP 1'7" DP 1'6" DP 1'9" DP 7'11" DP 11' DP4'9" DP4'9" DP13'6" DP6'3" DP 5'8" DP 4'1" DP 3'6" D P 4'8" DP 12'6" DP 13'6" DP11'6"DP10' DP 8'5" D P 8'11" D P 8'10" D P 9' DP3'3" DP3'1" DP3'2" DP2'10" DP1'6" DP1'3" DP 1'9" DP1'7" DP2'5" DP1'7" DP1'7" DP1'4" DP1'5" DP1'10" DP3'1" DP 1' DP 1'10" DP 1'11" DP 2' DP 3'1" DP 3'1" DP 3'6"DP 1'7" DP 2'9" DP 2'1" DP 1'9" DP 1'6" DP 2'1" DP 2'3" DP 2'1" DP 2'3" D P 1'11" DP 1'11" DP 1'11" DP 2'5" D P 1'8" DP 2'1" D P 1'11" DP 2'5" D P 2' DP 2'4"DP 2'10" D P 2'5" DP 2' DP 2'4"DP 2'5" DP5'4" DP5' DP5'5" DP4'8" DP 4'DP3'7"DP2' DP 1'9" DP 2' DP1'9" DP 2'4" DP 2' DP 1'10" DP 2'1" DP 3'11"DP 6'4" DP6'3" DP6'7" DP 2' DP 3'2"DP2'6" DP 4'11" D P 3'11" DP 2'8" DP 3'10" D P 3'3" DP 5'6" D P 7'11" DP 6'7" DP4'5" DP 6'9" DP 6' DP 7'6" DP 5'6" DP 2'5" DP 2'DP 400 404 418 CO 2 BLRD 3'11" DP4'11" DP 3'5" DP3'9" DP 3'10" DP 2'2" DP 1'5" DP BROADBANDVAULT 1' 11" DP 2'3" DP3'11" DP 4'11" DP 1'7" DP 4'5" DP5'6" DP 1' 8" DP 2'5" DP 1'11" DP 3'8" DP4'9" DP 1'4" DP 3' DP5'8" DP 5'10" DP6'2" DP5'5" DP 6' DP4' DP 1'5" DP1'7" DP 2'8" DP 2'4" DP 2'6" DP 4'2" DP 2'4" DP 12' DP 6'11" 3'6" 4'8" 8'11" 1'7" 2' 6'9"4'5" ED(TYP.) ED(TYP.) ED(TYP.) ED(TYP.) 3'10" 4'1" 4'9"7" 4'1" 3'11" 5'9" 5" 2'1" 1'11" 9"2'4" 3'1"2'11"3'3" 4'9" 4'11"2'8"2'1"2'8"2'7"2'5" 7"1'1" 1'4" 2'2'1" 2'9" 6" TREE30' DLN 1.5' RET WALLPLANTER 1.5' RET WALLPLANTER CO HH N T C 5 0 9 + 5 3 N TC 510+00 S TC 609+53 S TC 610+00 HA R D I E 3 1 0 + 0 0 HAR D I E 3 0 9 + 0 0 HA R D I E 3 1 0 + 0 0 RAINIER 2 0 4 + 0 0 RAINIER 205+ 0 0 RAINIER 206+00 RAINIER 207+00 RAINIER 2 0 8 + 0 0 RAINI E R 2 0 9 + 0 0 N TC STA 510+04.91 = RAINIER STA 207+16.93 S TC STA 610+02.99 = RAINIER STA 206+67.81 S I G N SIGN S I G N / / / // / // / / / / / / // / / / / / / / / / / // / / / // / / / / // / / / / / / / / / / / / / / U T H H H H V L T V L T V L T V L T S SW S D S D SS S S SD SD SD SD SD SD SD SD S D 3 5 M P H DRW E C O EE E E WV 3WV WV W V 3 W V W V WV HH HH HH HH HH HH HH HH H H HH H H ELEC VLT E L E C V L T 2IRRG GV G V WM G G FO FO FO FO FO E E E E E E E G G G G G E E E E E E E E E E E E E E E G G G G G G FO FO FO FO FO FO FO FO FO SDSD FO F O FO FO FO FO FO FO FO FO FO FO FO FO FO FO SD SD SD SDSDSD SD SD SD SD SD SD SD SD SDSD SD SD SD SD S D SD SD SD SD E E E E E E E E F O FO F O FO F O FO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS F O FO F O F O FO F O W W W SS SS SS SD SD SD SD REN T O N RENTON RENTON RENTON PSE GAS PSE GAS P S E G A S PS E G A S T T T T T T T T T G V I R R G 6 ' 9 " D P 1 ' D P 1'11" D P 2'3"DP 2' DP 2' D P 3 ' 1 1 " D P 1'7" DP 2'9" DP2'1" DP1'9" DP1'6" DP2'1" DP2'3" DP 2'1" DP 2'3" DP 3 ' 1 1 " D P 6 ' 4 " D P 6 ' 3 " D P 6 ' 7 " D P 4'11" DP 3'11" DP 2'8" DP 3'10" DP 3'3" DP 5'6" DP G G 4 0 4 2 ' 2 " D P 2 ' 3 " D P 3 ' 1 1 " D P 4 ' 1 1 " D P ED (TYP.) ED (TYP.) RAINIER AVE S HARD I E A V E S W 38 102-17 24 MWS-66 42 LF 12" DI @ 0.50% 4 LF 12" SD @ 0.53% 24 25 26 26 26 3102-18 5 LF 8" SD @ 3.44% SEE KING COUNTY WASTEWATER TREATMENT DIVISION NOTES SEE KING COUNTY WASTEWATER TREATMENT DIVISION NOTES 41 FIL-3 KING COUNTY WASTEWATER TREATMENT DIVISION NOTES: 1.THE LPA PROGRAM MUST BE CONTACTED AT 206-477-5414 OR LPA.team@kingcounty.gov AT LEAST (10) WORKING DAYS IN ADVANCE OF THE PRE-CONSTRUCTION CONFERENCE FOR THIS PROJECT. 2.THE LPA PROGRAM MUST BE CONTACTED AT 206-477-5414 OR LPA.team@kingcounty.gov AT LEAST (10) WORKING DAYS PRIOR TO THE CONSTRUCTION ACTIVITY WITHIN 50 FEET OF THE KING COUNTY SEWER PIPE. 3.KING COUNTY SHALL BE PRVIDED A COPY OF THE "CONTRACTOR'S NOTICE TO PROCEED" AND CONTRACTOR'S CONTACT INFORMATION PIOR TO THE START OF CONSTRUCTION. MATCHLINE: SEE DWG BT120-CDP201 MATCHLINE: SEE DWG BT120-CDP203 M A T C H L I N E : N O T U S E D T H I S S E R I E S 20 40 SCALE IN FEET 01020 (1" = 20') N 102 103 201 202 203 204 205 SW 7TH ST RAI N I E R AVE S HA R D I E AV E S W SR - 1 6 7 KEY MAP SW GRA D Y WAY 101 104 105 MA T C H L I N E : N O T U S E D T H I S S E R I E S 21 106 107 21 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 07 / 1 3 / 2 6 | 3: 0 8 P M | SA K S H I G C: \ P W W O R K I N G \ J A C O B S _ B & I \ S A K S H I G @ O S B O R N C O N S U L T I N G . C O M \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - C D P 1 0 2 - 1 0 6 . D W G S1-BT120-CDP102-106 FACILITY ID: Xrefs: xS1-BT120-VRX001 xS1-BT1P20-VSF100 xS1-BT120-CDN001 xS1-BT120-CPP001 xBRT-CUD05-TB22x34 xS1-BTP120-GZK010 xS1-BT120-CAP001 GB-SEAL-SS56324 xS1-BT120-CDP001 xS1-BT120-CGP001 xS1-BT120-RPP001 xS1-BT120-CZN002 xS1-BT120-CZN003 OSBORN CONSULTINGINCORPORATED 43 43 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CIVIL DRAINAGE PLAN RAINIER STA 204+00 TO RAINIER STA 208+50 BT120-CDP102 BT120 164 B S. SRIDHARAN H. ONG R. PARISH S. SRIDHARAN 0 12/10/2024 SS RP SS ISSUED FOR BID 1 06/13/2025 SS RP SS ADDENDUM #1 A 10/24/2025 SS RP SS COR PERMIT REVISION - CNWD#001 B 07/01/2026 SS RP SS FC #8 RTA/CN 0205-24 1"=20' 47 B B B 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332140 GENERAL NOTES: 1.SEE BT120-CDD501-504 SHEETS FOR DRAINAGE DETAILS. 2.SEE BT120-CRY101-105 SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE BT120-CSP101-107 SHEETS FOR SITE PREPARATION PLANS. 4.SEE BT120-CPP101-107 SHEETS FOR PAVING PLANS. 5.SEE BT120-UCP101-205 SHEETS FOR EXISTING STORM STRUCTURES/PIPES REMOVAL, AND UTILITIES PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS. 8.USE WSDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. 9.PVC PIPE MATERIAL SHALL NOT BE USED FOR STORM SD PIPE SPANS WITH 3 FEET OF COVER OR LESS. 10.ALL STRUCTURES SHALL BE HS 20 LOAD RATED UNLESS OTHERWISE NOTED. SEE CDD DETAIL SHEETS FOR PROPRIETARY BMP LOADING CONSIDERATIONS CONC CONC CONC SIGN DEBRIS SIGN SIGN SIGN / / / / CONC UT UT UT VLT VLT VLT VLT VLT HH VLTS VLT TRASHBIN TRASHBIN SW SW SW SW DRW DRW TRASHBIN SW SW SW DRW DRW SW SW DRW SW SW SW SW DRW CONC WALL TTTTMHGV GVGV GV GV 2 MISCMH GV GV TMH TMH GV GV GATE CW SW SW CONCBENCH 4' WOO D F N C CW SW CO N C B E N C H CONC BEN C H AR T W O R K CONC DRW DRW SW SW SW SW DRW DRW CO GV GV GV GV GV GM 2VLTS HH TTMH GM X6' CLEF 6' TEMP CLEF X 6' TEMP CLEF 6' TEMP CLEF 6' TEMPCLEF 8' CLEF X 5.5' CLEF SW 2' FNC GATE 6' CLEF 5.5' CLEF 6' CLEF BLDGEQUIP CONC SW SW SW SW SW SW SW SW CONC BASEREMOVED LT 4 BLRD 3 BLRD 3 BLRD 2 BLRD 6' TEM P C L E F 6' CLEF 2 BLRD 3 BLRD 6' TEM P C L E F SIGN POST ONCONC BASE 6' CLEF GATE STORAGESHED MISCVALV / // / SL SL SS CENTURYLINK CENTURYLINK F O CENTURYLINK FO CENTURYLINK FO CENTURYLIN K F O CENTURYLINK FO CENTURYLINK FO CENTU R Y L I N K F O RENTONRENTON RENTON RENTON RENTO N RENTON RENT O N RENT O N RENTON RENTON RENTON RENTO NRENTON RENT O N RENTON RENTO NRENTO N WSDO T F O WSDO T F O 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO 2-ZAYO F O 2-ZAYO FO PSE GAS PSE GA S PSE GAS PSE GA S PSE GAS PSE GAS PSE GAS PSE GAS PSE GAS PSE GAS PSE G A S PSE G A S PSE GAS PSE GAS FOVLT HH GV 5'4" DP 6'8" DP 5' DP 4' DP4' DP 3' DP3'9" DP3'4" DP 2'11" DP 6'9" DP 1'DP 1'11" D P 2'3"DP 2' DP2' DP3'11" DP 3'6" DP 5'9" DP 7'2" DP6'11" DP 7' DP 6'6" DP 4'4" DP 4'3" DP 3'7" DP 2' DP 4'10" DP 5'9" DP 4'7" DP 1'11" DP1'11" DP2'6" DP 5' DP1'4" DP 2'6" DP2'2" DP 3'1" DP2'6" DP 1'7" DP 1'9" DP 1'8" DP 1'6" DP 1'6" DP 1'7" DP 1'6" DP 1'9" DP 7'11" DP 11' DP4'9" DP4'9" DP13'6" DP6'3" DP 5'8" DP 4'1" DP 3'6" D P 4'8" DP 12'6" DP 13'6" DP11'6"DP10' DP 8'5" D P 8'11" D P 8'10" D P 9' DP3'3" DP 3'1" DP3'2" DP2'10" DP1'6" DP1'3" DP 1'9" DP1'7" DP2'5" DP1'7" DP1'7" DP1'4" DP1'5" DP1'10" DP3'1" DP 1' DP 1'10" DP 1'11" DP 2' DP 3'1" DP 3'1" DP 3'6"DP 1'7" DP 2'9" DP 2'1" DP 1'9" DP 1'6" DP 2'1" DP 2'3" DP 2'1" DP 2'3" D P 1'11" DP 1'11" DP 1'11" DP 2'5" D P 1'8" DP 2'1" D P 1'11" DP 2'5" D P 2' DP 2'4"DP 2'10" D P 2'5" DP 2' DP 2'4"DP 2'5" DP5'4" DP5' DP5'5" DP4'8" DP 4'DP3'7"DP2' DP 1'9" DP 2' DP1'9" DP 2'4" DP 2' DP 1'10" DP 2'1" DP 3'11"DP 6'4" DP6'3" DP6'7" DP 2' DP 3'2"DP2'6" DP 4'11" D P 3'11" DP 2'8" DP 3'10" D P 3'3" DP 5'6" DP 7'11" DP 6'7" DP4'5" DP 6'9" DP 6' DP 7'6" DP 5'6" DP 2'5" DP 2'DP 400 404 418 CO 2 BLRD 3'11" DP4'11" DP 3'5" DP3'9" DP 3'10" DP 2'2" DP 1'5" DP BROADBANDVAULT 1' 11" DP 2'3" DP3'11" DP 4'11" DP 1'7" DP 4'5" DP5'6" DP 1' 8" DP 2'5" DP 1'11" DP 3'8" DP4'9" DP 1'4" DP 3' DP5'8" DP 5'10" DP6'2" DP5'5" DP 6' DP4' DP 1'5" DP1'7" DP 2'8" DP 2'4" DP 2'6" DP 4'2" DP 2'4" DP 12' DP 6'11" 3'6" 4'8" 8'11" 1'7" 2' 6'9"4'5" ED(TYP.) ED(TYP.) ED(TYP.) ED(TYP.) 3'10" 4'1"4'9"7" 4'1" 3'11" 5'9" 5" 2'1" 1'11" 9"2'4" 3'1"2'11"3'3" 4'9" 4'11"2'8"2'1"2'8"2'7"2'5" 7"1'1" 1'4" 2'2'1" 2'9" 6" TREE30' DLN 1.5' RET WALLPLANTER 1.5' RET WALLPLANTER CO HH GRADY 151+00 GRADY 152+00 GRADY 153+00 GRADY 154+00 GRADY 155+00 GRADY 156+00 X X X XXXXXXXXXX X X X X X CONC VLT SS SS SS SS SS SS SS SS S S SD SW C O N C B E N C H C O N C B E N C H YIELD A R T W O R K OE OE OE OE OE OE OE OE SW SWE E HH HH 2 HH HH 2ELEC VLT E E E E E E E E E E E E E E E EEE E EEEEE E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W SD SD SD SD SD SD SD SD SD SD SD SD FO FO FO FO FO FO FO FO FO FO SD SD S D FO FO FO OEOE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE SD SD SL FO FO FO FO FO FO FO SS SS SS SS SS SS SS SS SS SS SS C E N T U R Y L I N K F O CENTURY L I N K F O 2-ZAYO FO 2-ZAYO FO 2-ZAYO FO FO VLT3'6" DP 5'9" DP 7'2" DP 6'11" DP 7' DP 6'6" DP 4'4" DP 4'3" DP 3'7" DP 2' DP 4'10" DP 5'9" DP 4'7" DP 1'11" DP 1'11" DP 2'6" DP 5' DP 1'4" DP 2'6" DP 2'2" DP 3'1" DP 2'6" DP 1'7" DP 1'9" DP 8 ' 5 " D P 8 ' 1 1 " D P 8 ' 1 0 " D P 9 ' D P 3'3" DP3'1" DP3'2" DP2'10" DP1'6" DP1'3" DP1'9" DP1'7" DP2'5" DP1'7" DP 1'7" DP1'4" DP 1'5" DP1'10" DP 3'1" DP 1' DP 2'4" DP 2'5" D P 4'DP 3'7" DP 2' DP 400 W W E E E E E TTTT WV WV C C SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD 1' 8" D P 1'11" D P 3'8" DP 4'9" DP 1'4" DP 3' DP 5'8" DP 5'10" D P 6'2" DP 5'5" DP 6' DP 4' DP 6'11" 8' 1 1 " ED (TYP.) SD SD SD SD SD SD SD SD SD 2 WV HH S D S D S GRADY WAY BOTTOM OF WET BIOSWALE BOTTOM OF WET BIOSWALE TOP OF WET BIOSWALE IE (IN) 24.28 TOP OF WET BIOSWALE IE (OUT) 24.07 13 104-86 63 LF 12" DI @ 0.50% WESTERN WET BIOSWALE CENTRAL WET BIOSWALE 44 LF 12" SD @ 0.49% 28 2 7 28 2 6 27 282 8 27 26 25 24 28 34 FIL-4 34FIL-5 SEE LANDSCAPING PLANS FOR DETAILS (TYP.) IE (OUT) 25.59 10 LF 12" SD @ 0.41% SEE BT120-CDP 105 29 104-88 10 LF 12" SD @ 0.52% DRAINAGE STRUCTURE TABLE STRUCTURE 104-86 104-88 FIL-4 FIL-5 STRUCTURE DETAILS CB TYPE 1 STA. 152+35.57 (86.39', LT) RIM 23.58 CB TYPE 2 - 48" STA. 155+08.11 (28.09', LT) RIM 27.07 TYPE C UNIT STA. 154+98.55 (26.70', LT) RIM 27.11 TYPE C UNIT STA. 155+18.79 (26.70', LT) RIM 27.16 PIPES IN IE 22.40 (W) IE 22.20 (E) IE 22.45 (W) IE 22.24 (E) PIPES OUT IE 21.61 (NW) IE 22.10 (S) IE 22.45 (E) IE 22.24 (W) EX EX EX UNK (S) EX CONTRACTOR TO FIELD VERIFY STA SEE BT120-CDD503 STA SEE BT120-CDD503 KEY NOTES: KEY NOTES: INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00, WITH BEEHIVE GRATE PER COR STD PLAN 262.40. SEE DWG. NO. BT120-CDD504 FOR DETAILS. INSTALL INLET/OUTFALL PROTECTION WITH QUARRY ROCK RIPRAP PAD (MINIMUM THICKNESS IS 1 FEET) PER WSDOT STD. SPECIFICATION 8-15.3(6) AND 9-13, AND PER COR STD PLAN 267.10 NOTE 18 INSTALL WET BIOFILTRATION SWALE (VAR. BOTTOM WIDTH). SEE DWG. BT120-CDD505 AND BT120-CDD506 FOR DETAILS. ADJUST RIM TO GRADE. REMOVE EXISTING INLET AND INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00, WITH OPEN CURB FACE FRAME AND GRATE PER COR STD PLAN 203.00. RE-CONNECT EXISTING PIPES TO THE NEW CATCH BASIN PER SPECIAL PROVISIONS 2-02 AND 7-05. REMOVE EXISTING CATCH BASIN AND INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00. WITH FRAME AND VANED GRATE PER COR STD PLAN 204.00. RE-CONNECT EXISTING PIPES TO THE NEW CATCH BASIN PER SPECIAL PROVISIONS 2-02 AND 7-05. INSTALL BIOFILTRATION SYSTEM TYPE C UNIT. SEE DWG. BT120-CDD503 FOR DETAILS AND SPECIAL PROVISIONS 7-05. INSTALL 12" CONCRETE CULVERT. STRUCTURE FRAME AND COVER MEET AASHTO LOAD 13 21 18 19 26 29 42 34 STRUCTURE FRAME AND COVER MEET AASHTO LOAD RATING HS-25. INSTALL BEVELED ENDS PER COR STD PLAN 221.00 CONTRACTOR SHALL MATCH EXISTING PIPE CENTERLINE LOCATION AND INVERT ELEVATION(S) OF EXISTING CONNECTION(S). DISCREPANCIES BETWEEN PLAN LOCATION AND FIELD LOCATION SHALL BE REPORTED TO THE RESIDENT ENGINEER PRIOR TO STARTING CONSTRUCTION. 43 44 47 20 40 SCALE IN FEET 01020 (1" = 20') N 102 103 201 202 203 204 205 SW 7TH ST RAI N I E R AVE S HA R D I E AV E S W SR - 1 6 7 SW GRA D Y WAY 101 104 105 MA T C H L I N E : N O T U S E D T H I S S E R I E S MA T C H L I N E : G R A D Y S T A 1 5 6 + 5 0 SE E D W G BT 1 2 0 - C D P 1 0 5 MATCHLINE: SEE DWG BT120-CDP205 BT120-C-GRADY MATCHLINE: SEE DWG BT120-CDP204 21 19 19 KEY MAP 106 107 18 1818 18 42 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 07 / 0 1 / 2 6 | 2: 5 8 P M | SA K S H I G C: \ P W W O R K I N G \ J A C O B S _ B & I \ S A K S H I G @ O S B O R N C O N S U L T I N G . C O M \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - C D P 1 0 2 - 1 0 6 . D W G S1-BT120-CDP102-106 FACILITY ID: Xrefs: xS1-BT120-VRX001 xS1-BT1P20-VSF100 xS1-BT120-CDN001 xS1-BT120-CPP001 xBRT-CUD05-TB22x34 xS1-BTP120-GZK010 xS1-BT120-CAP001 GB-SEAL-SS56324 xS1-BT120-CDP001 xS1-BT120-CGP001 xS1-BT120-RPP001 xS1-BT120-CZN002 xS1-BT120-CZN003 OSBORN CONSULTINGINCORPORATED 44 44 44 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CIVIL DRAINAGE PLAN GRADY STA 151+00 TO GRADY STA 156+50 BT120-CDP104 BT120 165 B S. SRIDHARAN H. ONG R. PARISH S. SRIDHARAN 0 12/10/2024 SS RP SS ISSUED FOR BID 1 06/13/2025 SS RP SS ADDENDUM #1 A 10/24/2025 SS RP SS COR PERMIT REVISION - CNWD#001 B 07/01/2026 SS RP SS FC #8 RTA/CN 0205-24 1"=20' 21 21 4347 47 47 B B 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332141 7-15-2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332143 DEVELOPMENT ENGINEERING msippo 07/22/2026 DRAINAGE STRUCTURE TABLE STRUCTURE 203-11 203-13 203-14 203-45 203-46 203-57 203-62 203-63 203-64 203-65 203-71 203-72 203-73 203-74 203-82 STRUCTURE DETAILS CB TYPE 1L STA. 612+50.48 (61.83', RT) RIM 26.58 CB TYPE 1 STA. 611+10.40 (94.60', RT) RIM 24.64 CB TYPE 1 STA. 204+79.77 (98.15', RT) RIM 25.17 CB TYPE 2-48" STA. 716+28.18 (79.73', RT) RIM 27.15 CB TYPE 2-60" STA. 716+10.41 (57.64', RT) RIM 27.18 CB TYPE 1 STA. 612+49.06 (116.59', RT) RIM 27.62 CB TYPE 1 STA. 204+38.56 (97.20', RT) RIM 25.53 CB TYPE 1 STA. 203+87.58 (101.24', RT) RIM 25.82 CB TYPE 1 STA. 204+38.47 (64.42', RT) RIM 25.03 CB TYPE 2-48" STA. 613+57.39 (66.58', RT) RIM 27.40 CB TYPE 1 STA. 613+53.93 (165.92', RT) RIM 26.95 CB TYPE 1L STA. 153+96.92 (214.14', LT) RIM 26.92 CB TYPE 2-48" STA. 611+73.45 (62.25', RT) RIM 25.25 CB TYPE 1 STA. 613+70.81 (183.62', RT) RIM 26.98 CB TYPE 1 STA. 613+92.30 (151.92', RT) RIM 27.52 PIPES IN IE 22.82 (SW) IE 21.65 (SW) IE 22.16 (S) IE 21.35 (W) IE 19.53 (E) IE 21.03 (S) IE 22.51 (S) IE 22.51 (W) IE 22.80 (S) IE 23.03 (SW) IE 23.62 (NE) IE 25.67 (NW) IE 25.67 (SW) PIPES OUT IE 22.82 (NE) IE 21.65 (NE) IE 22.16 (NE) IE 21.35 (N) IE 19.53 (W) IE 23.10 (NE) IE 22.51 (N) IE 22.80 (N) IE 22.80 (E) IE 23.03 (NW) IE 23.53 (NE) IE 23.62 (S) IE 22.05 (N) IE 23.85 (SW) IE 25.17 (N) EX EX KEY NOTES: INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00, WITH RECTANGULAR FRAME AND VANED GRATE PER COR STD PLANS 204.00 AND 204.20, RESPECTIVELY. INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER (PRIVATE) PER COR STD PLAN 204.40. RIMS TO BE NON-SLIP WHEN LOCATED WITHIN WALKWAYS. INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH FRAME AND VANED GRATE PER COR STD PLANS 204.00 AND 204.20, RESPECTIVELY. INSTALL 3' WIDE CONCRETE VALLEY GUTTER. SEE DWG. BT120-CRD123 FOR DETAILS. INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER PER COR STD PLAN 204.50. CONNECT EXISTING 30-INCH STORM DRAIN PIPES AND THE NEW 12-INCH PIPE(S) TO THE NEW CATCH BASIN PER SPECIAL PROVISIONS 7-05. ADJUST RIM TO GRADE. EXISTING SD PIPE TO REMAIN. INSTALL 6-INCH CLEANOUTS PER COR STD PLAN 1 3 9 21 22 6 4 GENERAL NOTES: 1.SEE BT120-CDD501-504 SHEETS FOR DRAINAGE DETAILS. 2.SEE BT120-CRY101-105 SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE BT120-CSP101-107 SHEETS FOR SITE PREPARATION PLANS. 4.SEE BT120-CPP101-107 SHEETS FOR PAVING PLANS. 5.SEE BT120-UCP101-205 SHEETS FOR EXISTING STORM STRUCTURES/PIPES REMOVAL, AND UTILITIES PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS. 8.USE WSDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. 9.PVC PIPE MATERIAL SHALL NOT BE USED FOR STORM SD PIPE SPANS WITH 3 FEET OF COVER OR LESS. 10.ALL STRUCTURES SHALL BE HS 20 LOAD RATED UNLESS OTHERWISE NOTED. SEE CDD DETAIL SHEETS FOR PROPRIETARY BMP LOADING CONSIDERATIONS SD E 3 W V W V H H H H HH HH 2 I R R G W M GV 2VLTS E E E E W W W C C C C C C C C C C C C C E E E EE E E E E E E E SD SD X X X X X X X X X X X X X X X X X X X X 6' TEM P C L E F X X X X X 8' CL E F // / / / / / / // / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 6 ' T E M P C L E F SD FO FO FO FO FO FO FO FO FO EE E E E E E E E E F O F O F O F O F O F O F O FO S S S S S S S S S S S S EE E E E E E E E E E E E HH E E C C C W BROA D B A N D VAULT 3'1" 2'11" 3'3" SS SS SS SS SS SS 28 27 26 25 25 2 8 28 3 0 30 26 27 25 RAILAKDW 716+00 1 203-14 203-13 1 204-27 FIL-1 41 203-73 4 203-11 38 1 203-14 1 203-64 203-62 1 203-63 1 203-72 38 203-71 1 203-65 4 203-74 1 1 203-82 1 203-83 203-57 1 203-46 9 203-45 3 33 LF 8" DI @ 0.88% 46 LF 12" DI @ 0.64% 45 LF 12" DI @ 0.51% 99 LF 12" SD @ 0.50% 63 LF 12" SD @ 1.88% 28 LF 12" DI @ 0.53% 26 LF 18" DI @ 0.32% 61 LF 12" DI @ 0.51% 55 L F 1 2 " S D @ 0 . 5 1 % 25 LF 12" DI @ 0.52% 23 LF 12" SD @ 1.51% 44 LF 12" SD @ 0.50% 28 LF 12" SD @ 1.13% 78 L F 1 2 " D I @ 0 . 6 5 % 50 LF 12" DI @ 0.52% 37 LF 12" DI @ 0.95% 34 LF 6" DI @ 0.96% 22 LF 6" DI @ 1.23% 36 LF 6" DI @ 1.05% 28 LF 12" DI @ 0.51% CO /// / SS WSDOT F O 6'11" 3'6" 4'8" 8'11" 1'7" 2'6'9"4'5" ED(TYP.) ED(TYP.) ED(TYP.) ED(TYP.) 3'10" 4'1" 4'9"7" 4'1" 3'11" 5'9" 5" 2'1" 1'11" 9"2'4" 3'1"2'11"3'3" 4'9" 4'11"2'8"2'1"2'8"2'7"2'5" 7"1'1" 1'4" 2'2'1" 2'9" 1.5' RET WALLPLANTER 1.5' RET WALLPLANTER R51.90 R48.54 R50.00 R20.00 R19.89 R30.00 R35.00 R40.00 R40.0 0 R45.00 R35.00 R50.00 R35.00 R50.00 203-83 FIL-1 CB TYPE 1 STA. 613+89.17 (125.10', RT) RIM 27.58 TYPE A UNIT STA. 206+13.12 (51.98', RT) RIM 23.96 IE 25.03 (S) IE 25.53 (NW)IE 25.03 (NE) IE 20.40 (NE)STA SEE BT120-CDD501 DRAINAGE STRUCTURE TABLE STRUCTURE STRUCTURE DETAILS PIPES IN PIPES OUT INSTALL 6-INCH CLEANOUTS PER COR STD PLAN 226.00. INSTALL ROOF DOWNSPOUT CONNECTIONS. SEE DETAIL 1, SHEET BT120-AED903. INSTALL CATCH BASIN TYPE 1L PER COR STD PLAN 200.10, WITH OPEN CURB FACE FRAME AND GRATE PER COR STD PLAN 203.00. INSTALL BIOFILTRATION SYSTEM TYPE A UNIT. SEE DWG. BT120-CDD501 FOR DETAILS AND SPECIAL PROVISIONS 7-05. SEE CDD507 FOR OIL DEBRIS HOOD INSTALLATION AND SPECIAL PROVISIONS 7-05. 25 37 38 41 46 KEY NOTES:AND SPECIAL PROVISIONS 7-05. CONTRACTOR SHALL MATCH EXISTING PIPE CENTERLINE LOCATION AND INVERT ELEVATION(S) OF EXISTING CONNECTION(S). DISCREPANCIES BETWEEN PLAN LOCATION AND FIELD LOCATION SHALL BE REPORTED TO THE RESIDENT ENGINEER PRIOR TO STARTING CONSTRUCTION. 47 KEY NOTES: 20 40 SCALE IN FEET 01020 (1" = 20') N M A T C H L I N E : SE E D W G BT 1 2 0 - C D P 2 0 4 MATCHLINE: SEE DWG BT120-CDP205 MA T C H L I N E : SE E D W G BT 1 2 0 - C D P 1 0 2 M A T C H L I N E : N O T U S E D T H I S S E R I E S MATCHLINE: SEE DWG BT120-CDP201 102 103 201 202 203 204 205 SW 7TH ST RAI N I E R AVE S HA R D I E AV E S W SR - 1 6 7 KEY MAP SW GRAD Y WAY 101 104 105 22 21 21 6 107 106 No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 07 / 1 3 / 2 6 | 3: 3 6 P M | SA K S H I G C: \ P W W O R K I N G \ J A C O B S _ B & I \ S A K S H I G @ O S B O R N C O N S U L T I N G . C O M \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - C D P 2 0 1 - 2 0 5 . D W G S1-BT120-CDP201-205 FACILITY ID: Xrefs: xS1-BT120-VRX001 xS1-BT120-CDN001 xS1-BTP120-CDP001 xS1-BTP120-CPP001 xBRT-CUD05-TB22x34 xS1-BTP120-GZK010 xS1-BTP120-CAP001 xS1-BTP120-VSF100 xS1-BT120-CGP001 xS1-BT120-CMP001 xS1-BT120-APP211 GB-SEAL-SS56324 xS1-BT120-SGP301 xS1-BT120-RPP001 xS1-BT120-CZN002 xS1-BT120-CZN003 OSBORN CONSULTINGINCORPORATED 25 37 37 37 46 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER BT120-CDP203 BT120 170 B S. SRIDHARAN H. ONG R. PARISH S. SRIDHARAN 0 12/10/2024 SS RP SS ISSUED FOR BID 1 06/13/2025 SS RP SS ADDENDUM #1 A 10/24/2025 SS RP SS COR PERMIT REVISION - CNWD#001 B 07/01/2026 SS RP SS FC #8 RTA/CN 0205-24 1"=20' 47B B B 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332146 DRAINAGE STRUCTURE TABLE STRUCTURE 204-02 204-21 204-23 204-27 204-32 204-33 204-34 204-35 STRUCTURE DETAILS CB TYPE 2-60" STA. 720+55.33 (54.79', LT) RIM 27.08 CB TYPE 2-48" STA. 720+56.43 (47.28', LT) RIM 27.17 CB TYPE 2-48" STA. 616+99.23 (59.11', RT) RIM 27.69 CB TYPE 1 STA. 614+03.21 (69.15', RT) RIM 27.37 CB TYPE 1L STA. 720+36.97 (22.83', LT) RIM 26.71 CB TYPE 1L STA. 720+40.85 (11.17', LT) RIM 26.85 CB TYPE 1L STA. 720+49.15 (11.16', RT) RIM 26.75 CB TYPE 1L STA. 721+37.65 (11.27', RT) RIM 25.55 PIPES IN IE 19.91 (N) IE 19.82 (SE) IE 19.40 (E) IE 19.87 (SW) IE 20.80 (N) IE 20.80 (W) IE 24.72 (SW) IE 25.22 (NW) IE 22.06 (SE) IE 22.06 (NE) IE 22.12 (SE) IE 22.25 (NE) IE 22.69 (E) IE 22.69 (NW) IE 22.69 (SE) PIPES OUT IE 19.35 (W) IE 19.87 (NW) IE 20.80 (S) IE 24.72 (N) IE 22.06 (NW) IE 22.12 (NW) IE 22.25 (NW) IE 22.69 (SW) EX INSTALL ROOF DOWNSPOUT CONNECTIONS. SEE DETAIL 1, SHEET BT120-AED903. INSTALL CATCH BASIN TYPE 1L PER COR STD PLAN 200.10, WITH OPEN CURB FACE FRAME AND GRATE PER COR STD PLAN 203.00. REMOVE EXISTING SDMH PER SPECIAL PROVISIONS 2-02 AND INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER (PUBLIC) PER COR STD PLAN 204.50. RECONNECT EXISTING 30-INCH PIPES (NE AND SW) TO THE NEW CATCH BASIN PER SPECIAL PROVISIONS 7-05. STRUCTURE FRAME AND COVER MEET AASHTO LOAD RATING HS-30. CONTRACTOR SHALL MATCH EXISTING PIPE CENTERLINE LOCATION AND INVERT ELEVATION(S) OF EXISTING CONNECTION(S). DISCREPANCIES BETWEEN PLAN LOCATION AND FIELD LOCATION SHALL BE REPORTED TO THE RESIDENT ENGINEER PRIOR TO STARTING CONSTRUCTION. 37 38 40 45 47 GENERAL NOTES: 1.SEE BT120-CDD501-504 SHEETS FOR DRAINAGE DETAILS. 2.SEE BT120-CRY101-105 SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE BT120-CSP101-107 SHEETS FOR SITE PREPARATION PLANS. 4.SEE BT120-CPP101-107 SHEETS FOR PAVING PLANS. 5.SEE BT120-UCP101-205 SHEETS FOR EXISTING STORM STRUCTURES/PIPES REMOVAL, AND UTILITIES PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS. 8.USE WSDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. 9.PVC PIPE MATERIAL SHALL NOT BE USED FOR STORM SD PIPE SPANS WITH 3 FEET OF COVER OR LESS. 10.ALL STRUCTURES SHALL BE HS 20 LOAD RATED UNLESS OTHERWISE NOTED. SEE CDD DETAIL SHEETS FOR PROPRIETARY BMP LOADING CONSIDERATIONS X X CONC UT UT VLT SS SD SW WM ELEC VLT E GV GM WM WV WM 2VLTS C C C C C C C C C C C E E E E E E TS VLT HH GM E E E E E E E E E E E E E E E E E E E E F O FO FO FO FO FO FO FO F O SD SD SD SD FO FO HH HH X X X X X X X X X X X X X X X X X X X X X X X X X 6' CLEF X PP PP X X X X 2' FNC GATE / / 6' C L E F SW 4 BLRD 3 BLRD 3 BLRD X X X X 6' CLEF / / / / / / / / / / / ////// / / / / / / / / / / / ////// / / / ////////////// / / /// / / / / / / / / / / / // /// /// //// /// ////////////// /////// / / / / / / / / / / / / / / / / / //////////////// / / / / / / / / ////////////////// / / / / / / / / OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE /////// / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / BLD EQUIP 6' CLEF OE OE OE SD G G G G G E E E E E E E E E SS SS SS SS SS PSE GAS P S E G A S EEEE EEEEE G G G G G G E E E W W W E E E SS SS SS SS SS SS S S 2'1" 2'9" SS SS SS SS SS ELEC VLT HH S D S D 27 27 28 29 29 30 30 28 28 29 27 28 26 2 626 27 262 6 2 8 IE (OUT) 25.91 LAKE 400+00 LAK E 4 0 1 + 0 0 GRADY 15 9 + 0 0 LAKE STA 400+00.05 = GRADY STA 158+70.91 RAILAKDW 717+00 RAILAKDW 718+00 RAILAKDW 719+00 RAILA K D W 7 2 0 + 0 0 RAIL A K D W 7 2 1 + 0 0 204-27 1 3 204-23 204-43 30 24 MWS-69 38 204-32 38 204-33 38 204-34 1 204-41 38 1 203-65 4 203-74 1 1 204-39 1 204-75 38 204-35 10 204-02 1 203-82 1 203-83 3 204-45 40 12 LF 12" SD @ 0.50% 84 LF 12" DI @ 0.54% 88 L F 1 2 " D I @ 0 . 5 0 % 8 LF 12" SD @ 0.66% 17 LF 12" SD @ 0.81% 45 LF 12" DI @ 0.51% 2 2 L F 1 2 " D I @ 0 . 5 3 % 25 LF 12" SD @ 0.79% 61 LF 12" DI @ 0.51% 25 LF 12" DI @ 0.52% 24 LF 12" SD @ 0.53% 57 L F 1 2 " D I @ 0 . 5 2 % 54 LF 12" SD @ 4.10% 63 LF 12" SD @ 1.40% 7 LF 12" DI @ 0.57% 28 LF 12" SD @ 1.13% 22 LF 12" SD @ 1.19% 34 LF 6" DI @ 0.96% 22 LF 6" DI @ 1.23% 36 LF 6" DI @ 1.05% 28 LF 12" DI @ 0.51% CO R 3 0 . 0 0 R4 0 . 0 0 R 4 0 . 0 0 R 4 5 . 0 0 R3 5 . 0 0 R5 0 . 0 0 R 3 5 . 0 0 R5 0 . 0 0 204-21 3 3 204-36 193 LF 30" CONC @ 0.10% 39 LF 30" CONC @ 0.13% /// / SS WSDO T F O 6'11" 3'6" 4'8" 8'11" 1'7" 2' 6'9"4'5" ED(TYP.) ED(TYP.) ED(TYP.) ED(TYP.) 3'10" 4'1" 4'9"7" 4'1" 3'11" 5'9" 5" 2'1" 1'11" 9"2'4" 3'1"2'11"3'3" 4'9" 4'11"2'8"2'1"2'8"2'7"2'5" 7"1'1" 1'4" 2'2'1" 2'9" 1.5' RET WALLPLANTER 1.5' RET WALLPLANTER R51.9 0 R48.54 R50.00 R20.00 R19.89 R30.00 R35.00 R40.00 R40.00 R45.00 R35.0 0 R50.00 R35.0 0 R50.0 0 204-36 204-39 204-41 204-43 204-45 204-75 MWS-69 CB TYPE 2-60" STA. 720+22.59 (75.27', LT) RIM 27.40 CB TYPE 1 STA. 721+20.51 (22.83', LT) RIM 25.63 CB TYPE 1 STA. 616+30.05 (99.27', RT) RIM 28.98 CB TYPE 2-60" STA. 717+81.95 (59.71', LT) RIM 29.94 CB TYPE 2-60" STA. 716+92.26 (5.40', LT) RIM 28.30 CB TYPE 1 STA. 721+36.97 (11.17', LT) RIM 25.55 TYPE D UNIT STA. ??? (???', ???) RIM 27.38 IE 19.30 (E) IE 19.20 (E) IE 19.10 (NE) IE 21.87 (SE) IE 19.40 (W) IE 22.51 (SW) IE 25.96 (N) IE 19.20 (SW) IE 19.40 (W) IE 22.81 (SE) IE 20.01 (NE) EX EXEX STA SEE BT120-CDD504 DRAINAGE STRUCTURE TABLE STRUCTURE STRUCTURE DETAILS PIPES IN PIPES OUT KEY NOTES: INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00, WITH RECTANGULAR FRAME AND VANED GRATE PER COR STD PLANS 204.00 AND 204.20, RESPECTIVELY. INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER (PRIVATE) PER COR STD PLAN 204.40. RIMS TO BE NON-SLIP WHEN LOCATED WITHIN WALKWAYS. INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER PER COR STD PLAN 204.50. CONNECT EXISTING 27-INCH STORM DRAIN PIPE (E) AND ALL NEW PIPES TO THE NEW CATCH BASIN PER SPECIAL PROVISIONS 7-05. EXISTING SD PIPE TO REMAIN. INSTALL BIOFILTRATION SYSTEM TYPE D UNIT. SEE DWG. BT120-CDD504 FOR DETAILS AND SPECIAL PROVISIONS 7-05. REMOVE EXISTING SDMH PER SPECIAL PROVISIONS 2-02 AND INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER (PUBLIC) PER COR STD PLAN 204.50. CONNECT THE NEW 27-INCH PIPE (NE) AND RECONNECT EXISTING 30-INCH PIPE (SW) TO THE NEW CATCH BASIN PER SPECIAL PROVISIONS 7-05. 1 10 22 3 30 24 KEY NOTES: 20 40 SCALE IN FEET 01020 (1" = 20') N No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 07 / 1 3 / 2 6 | 3: 4 3 P M | SA K S H I G C: \ P W W O R K I N G \ J A C O B S _ B & I \ S A K S H I G @ O S B O R N C O N S U L T I N G . C O M \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - C D P 2 0 1 - 2 0 5 . D W G S1-BT120-CDP201-205 FACILITY ID: Xrefs: xS1-BT120-VRX001 xS1-BT120-CDN001 xS1-BTP120-CDP001 xS1-BTP120-CPP001 xBRT-CUD05-TB22x34 xS1-BTP120-GZK010 xS1-BTP120-CAP001 xS1-BTP120-VSF100 xS1-BT120-CGP001 xS1-BT120-CMP001 xS1-BT120-APP211 GB-SEAL-SS56324 xS1-BT120-SGP301 xS1-BT120-RPP001 xS1-BT120-CZN002 xS1-BT120-CZN003 OSBORN CONSULTINGINCORPORATED MA T C H L I N E : SE E D W G BT 1 2 0 - C D P 2 0 3 MA T C H L I N E : SE E D W G BT 1 2 0 - C D P 2 0 5 MATCHLINE: SEE DWG BT120-CDP202 MATCHLI N E : SEE DWG BT120-CD P 1 0 4 MATCHLIN E : SEE DWG BT120-CD P 1 0 5 MA T C H L I N E : SE E D W G BT 1 2 0 - C D P 1 0 6 102 103 201 202 203 204 205 SW 7TH ST RAI N I E R AVE S HA R D I E AV E S W SR - 1 6 7 KEY MAP SW GRAD Y WAY 101 104 105 LIGHTING CHARGING YARD (SEE ELECTRICAL PLANS FOR DETAILS) 22 107 106 37 105-81 45 45 45 45 45 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER BT120-CDP204 BT120 171 B S. SRIDHARAN H. ONG R. PARISH S. SRIDHARAN 0 12/10/2024 SS RP SS ISSUED FOR BID 1 06/13/2025 SS RP SS ADDENDUM #1 A 10/24/2025 SS RP SS COR PERMIT REVISION - CNWD#001 B 06/30/2026 SS RP SS NCR #001 C 07/01/2026 SS RP SS FC #8 RTA/CN 0205-24 1"=20' 45 47 C C C C 47 C 47 C C C 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332147 DRAINAGE STRUCTURE TABLE STRUCTURE 205-49 205-50 205-51 205-76 205-77 205-78 FIL -2 STRUCTURE DETAILS CB TYPE 1 STA. 202+59.88 (64.27', RT) RIM 27.69 CB TYPE 1 STA. 202+59.48 (83.08', RT) RIM 27.97 CB TYPE 2-48" STA. 151+86.32 (126.40', LT) RIM 29.15 CB TYPE 1L STA. 716+11.15 (93.44', RT) RIM 26.61 CB TYPE 2-60" STA. 151+86.65 (183.66', LT) RIM 28.89 CB TYPE 1 STA. 203+19.47 (86.75', RT) RIM 27.00 TYPE A UNIT STA. 202+30.86 (330.22', RT) RIM 27.01 PIPES IN IE 24.57 (W) IE 21.29 (SE) IE 22.43 (N) IE 22.83 (E) IE 21.00 (S) IE 19.79 (E) IE 23.98 (S) PIPES OUT IE 24.67 (E) IE 24.57 (N) IE 21.29 (N) IE 21.61 (E) IE 19.79 (W) IE 23.98 (N) IE 23.01 (N) EX EX STA SEE BT120-CDD501 KEY NOTES: INSTALL CATCH BASIN TYPE 1 PER COR STD PLAN 200.00, WITH RECTANGULAR FRAME AND VANED GRATE PER COR STD PLANS 204.00 AND 204.20, RESPECTIVELY. INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00, WITH STORM ROUND FRAME AND COVER (PRIVATE) PER COR STD PLAN 204.40. RIMS TO BE NON-SLIP WHEN LOCATED WITHIN WALKWAYS. ADJUST RIM TO GRADE. EXISTING SD PIPE TO REMAIN. SAWCUT AND REMOVE SECTION OF EXISTING 30-INCH STORM DRAIN PIPE. INSTALL CATCH BASIN TYPE 2 PER COR STD PLAN 201.00 WITH STORM ROUND FRAME AND COVER PER COR STD PLAN 204.50. CONNECT EXISTING 30-INCH STORM DRAIN PIPES (E&W) AND THE NEW 12-INCH PIPE (SE) TO THE NEW CATCH BASIN PER SPECIAL PROVISIONS 7-05. INSTALL CATCH BASIN TYPE 1L PER COR STD PLAN 200.10, WITH RECTANGULAR FRAME AND RECTANGULAR SOLID METAL COVER PER COR STD PLANS 204.00 AND 204.10, RESPECTIVELY. INSTALL BIOFILTRATION SYSTEM TYPE A UNIT. SEE DWG. BT120-CDD501 FOR DETAILS AND SPECIAL PROVISIONS 7-05. CONTRACTOR SHALL MATCH EXISTING PIPE CENTERLINE LOCATION AND INVERT ELEVATION(S) OF EXISTING CONNECTION(S). DISCREPANCIES BETWEEN PLAN LOCATION AND FIELD LOCATION SHALL BE REPORTED TO THE RESIDENT ENGINEER PRIOR TO STARTING CONSTRUCTION. 1 21 22 3 27 41 39 47 GENERAL NOTES: 1.SEE BT120-CDD501-504 SHEETS FOR DRAINAGE DETAILS. 2.SEE BT120-CRY101-105 SHEETS FOR TYPICAL ROADWAY SECTIONS. 3.SEE BT120-CSP101-107 SHEETS FOR SITE PREPARATION PLANS. 4.SEE BT120-CPP101-107 SHEETS FOR PAVING PLANS. 5.SEE BT120-UCP101-205 SHEETS FOR EXISTING STORM STRUCTURES/PIPES REMOVAL, AND UTILITIES PLANS. 6.EXISTING FACILITIES TO BE PROTECTED-IN-PLACE UNLESS OTHERWISE NOTED. 7.FOR PROPOSED IMPROVEMENTS NOT SHOWN, SEE PAVING, TRAFFIC, AND UTILITY SHEETS. 8.USE WSDOT STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. 9.PVC PIPE MATERIAL SHALL NOT BE USED FOR STORM SD PIPE SPANS WITH 3 FEET OF COVER OR LESS. 10.ALL STRUCTURES SHALL BE HS 20 LOAD RATED UNLESS OTHERWISE NOTED. SEE CDD DETAIL SHEETS FOR PROPRIETARY BMP LOADING CONSIDERATIONS X X X X X X X X X X X X X X ASPH ASPH ASPH VLT S D S D S S S S S S S S S S S S S D HH S W OE OE OE SW D R W E E E E WV WV HH HH HH 3HH HH 2 HH HH 4ELE C V L T WM E E E E E E E W E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO SD SD SD FO FO FO FO FO FO FO FO S D S D SS SS SS SS SS E FOF O FO X X X X X X X X X X 6' TE M P C L E F X X X X X X X X X 6' TE M P C L E F X X // / / / / / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE SD 2-ZAY O F O C E E E E UTIL V L T HH 5'9" D P 7'2" D P 6'11" D P 7' DP 6'6" D P 4'10" D P 5'9" D P 4'7" D P E SD SD SD SD 3'8" D P 4'9" DP 3' DP 5'8" D P 5'10" D P 6'2" DP 5'5" D P 6'11 " ED (TYP . ) 4'9 " 4'11" 2'8" 2'1" 2'8" 2'7" 2'5 " 7" 1'1" 1'4" 2' SD SD SD SD SD SD SD HH 28 29 29 2 7 28 28 27 26 25 24 28 S GR A D Y W A Y R A I N I E R A V E S 28 GRA D Y 1 5 3 + 0 0 GRA D Y 1 5 4 + 0 0 R A I N I E R 2 0 2 + 0 0 205-78 1 205-50 1 205-49 1 205-76 39 205-51 3 FIL -2 41 EX 205-04 21 63 LF 12" DI @ 1.88% 5 4 L F 1 2 " D I @ 1 . 0 9 % 19 LF 12" DI @ 0.53% 5 7 L F 1 2 " S D @ 0 . 5 1 % 63 LF 12" SD @ 0.50% 22 LF 12" SD @ 1.19% R 5 1 . 9 0 R 4 8 . 5 4 R 5 0 . 0 0 R 2 0 . 0 0 R 1 9 . 8 9 R3 0 . 0 0 11 LF 8" SD @ 1.37% 205-77 27 /// / SS WSDOT F O 6'11" 3'6" 4'8" 8'11" 1'7" 2'6'9"4'5" ED(TYP.) ED(TYP.) ED(TYP.) ED(TYP.) 3'10" 4'1" 4'9"7" 4'1" 3'11" 5'9" 5" 2'1" 1'11" 9"2'4" 3'1"2'11"3'3" 4'9" 4'11"2'8"2'1"2'8"2'7"2'5" 7"1'1" 1'4" 2'2'1" 2'9" 1.5' RET WALLPLANTER 1.5' RET WALLPLANTER 20 40 SCALE IN FEET 01020 (1" = 20') N No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 07 / 1 3 / 2 6 | 3: 4 5 P M | SA K S H I G C: \ P W W O R K I N G \ J A C O B S _ B & I \ S A K S H I G @ O S B O R N C O N S U L T I N G . C O M \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - C D P 2 0 1 - 2 0 5 . D W G S1-BT120-CDP201-205 FACILITY ID: Xrefs: xS1-BT120-VRX001 xS1-BT120-CDN001 xS1-BTP120-CDP001 xS1-BTP120-CPP001 xBRT-CUD05-TB22x34 xS1-BTP120-GZK010 xS1-BTP120-CAP001 xS1-BTP120-VSF100 xS1-BT120-CGP001 xS1-BT120-CMP001 xS1-BT120-APP211 GB-SEAL-SS56324 xS1-BT120-SGP301 xS1-BT120-RPP001 xS1-BT120-CZN002 xS1-BT120-CZN003 OSBORN CONSULTINGINCORPORATED MAT C H L I N E : SEE D W G BT1 2 0 - C D P 1 0 4 22 MATCHLINE: SEE DWG BT120-CDP203 M A T C H L I N E : N O T U S E D T H I S S E R I E S 102 103 201 202 203 204 205 SW 7TH ST RAI N I E R AVE S HA R D I E AV E S W SR - 1 6 7 KEY MAP SW GRAD Y WAY 101 104 105 107 106 STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CIVIL DRAINAGE PLAN S RENTON TRANSIT CENTER BT120-CDP205 BT120 172 B S. SRIDHARAN H. ONG R. PARISH S. SRIDHARAN 0 12/10/2024 SS RP SS ISSUED FOR BID 1 06/13/2025 SS RP SS ADDENDUM #1 A 10/24/2025 SS RP SS COR PERMIT REVISION - CNWD#001 B 07/01/2026 SS RP SS FC #8 RTA/CN 0205-24 1"=20' 47 B B B 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332148 FC #8B07/01/2026 SS SSRP A 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332149 10 15 20 25 30 35 40 10 15 20 25 30 35 40 ''26 . 6 ' 24 . 8 6 ' 27 . 2 25 . 2 0 28 . 2 25 . 0 1 27 . 8 25 . 2 9 28 . 1 ' 25 . 6 2 ' 28 . 0 25 . 9 5 27 . 7 26 . 2 8 27 . 7 26 . 6 0 27 . 5 ' 26 . 9 2 ' 27 . 4 27 . 2 8 27 . 2 27 . 3 8 27 . 3 27 . 3 8 27 . 4 ' 27 . 2 4 ' 27 . 5 27 . 1 0 27 . 5 26 . 9 8 27 . 5 ' 27 . 4 2 ' 20 1 - 1 0 , C B T Y P E 1 L BT 1 2 0 - C - S T C ST A . 6 1 2 + 5 7 . 1 5 , 4 0 . 3 3 ' R T RI M 2 6 . 2 3 12 " I E ( I N ) 2 2 . 4 8 ( S W ) 12 " I E ( I N ) 2 2 . 4 8 ( S E ) 12 " I E ( O U T ) 2 2 . 4 8 ( N W ) EXISTING GROUND @ PIPE CL FINISHED GRADE @ PIPE CL 99 LF 12" SD @ 0.50% 20 1 - 7 9 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - S T C ST A . 6 1 3 + 2 2 . 2 1 , 3 9 . 5 0 ' R T RI M 2 7 . 0 6 12 " I E ( I N ) 2 2 . 8 1 ( S E ) 12 " I E ( O U T ) 2 2 . 8 1 ( N W ) 20 3 - 6 5 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - S T C ST A . 6 1 3 + 5 7 . 3 9 , 6 6 . 5 8 ' R T RI M 2 7 . 4 0 12 " I E ( I N ) 2 3 . 0 3 ( S W ) 12 " I E ( O U T ) 2 3 . 0 3 ( N W ) 20 3 - 7 1 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 3 + 5 3 . 9 3 , 1 6 5 . 9 2 ' R T RI M 2 6 . 9 5 12 " I E ( O U T ) 2 3 . 5 3 ( N E ) 20 1 - 4 8 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - S T C ST A . 6 1 1 + 1 1 . 7 1 , 4 5 . 0 0 ' R T RI M 2 4 . 8 6 12 " I E ( I N ) 2 1 . 3 9 ( S W ) 12 " I E ( I N ) 2 1 . 3 9 ( E ) 18 " I E ( O U T ) 2 1 . 3 9 ( N W ) 20 1 - 0 9 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - S T C ST A . 6 1 1 + 5 6 . 7 9 , 3 9 . 5 0 ' R T RI M 2 4 . 9 1 12 " I E ( I N ) 2 1 . 9 0 ( S ) 12 " I E ( I N ) 2 1 . 9 0 ( S E ) 12 " I E ( O U T ) 2 1 . 9 0 ( W ) 65 LF 12" SD @ 0.51% 44 LF 12" SD @ 0.50% 45 LF 12" DI @ 1.12% 100 LF 12" DI @ 0.58% 5 10 15 20 25 30 35 5 10 15 20 25 30 35 ''24 . 7 ' 23 . 6 7 ' 24 . 5 24 . 0 6 24 . 5 24 . 7 1 24 . 3 23 . 9 3 '''' 62 LF 8" DI @ 1.00% L FINISHED GRADE @ PIPE C L EXISTING GROUND @ PIPE C 20 1 - 2 7 , C B T Y P E 1 BT 1 2 0 - C - N T C ST A . 5 1 0 + 9 2 . 1 2 , 1 8 . 6 0 ' L T RI M 2 3 . 8 3 8" I E ( O U T ) 2 2 . 1 0 ( S W ) 20 1 - 3 5 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - S T C ST A . 6 1 0 + 8 3 . 3 6 , 1 8 . 7 8 ' L T RI M 2 4 . 1 5 8" I E ( I N ) 2 1 . 4 8 ( N E ) 12 " I E ( O U T ) 2 1 . 4 8 ( S ) 33 LF 12" DI @ 1.03% 20 1 - 1 6 , C B T Y P E 1 L BT 1 2 0 - C - S T C ST A . 6 1 0 + 8 5 . 6 4 , 1 4 . 1 7 ' R T RI M 2 3 . 6 7 12 " I E ( I N ) 2 1 . 1 4 ( S E ) 12 " I E ( I N ) 2 1 . 1 4 ( N ) 8" I E ( I N ) 2 1 . 1 4 ( W ) 16 " I E ( O U T ) 2 1 . 1 4 ( S W ) PROP 12" W IE 18.12 10 15 20 25 30 35 40 10 15 20 25 30 35 40 ''25 . 4 ' 24 . 4 6 ' 24 . 8 23 . 6 8 25 . 7 24 . 0 0 26 . 4 24 . 3 3 27 . 0 ' 24 . 6 5 ' 27 . 4 24 . 9 8 28 . 0 25 . 2 9 28 . 0 25 . 6 3 27 . 7 ' 25 . 9 5 ' 27 . 7 26 . 2 8 27 . 3 26 . 5 9 27 . 1 26 . 9 3 26 . 7 ' 27 . 2 5 ' '' 20 1 - 0 4 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 2 + 6 8 . 3 6 , 1 4 . 1 7 ' R T RI M 2 6 . 0 2 12 " I E ( I N ) 2 2 . 5 2 ( S E ) 12 " I E ( I N ) 2 2 . 5 2 ( N E ) 12 " I E ( O U T ) 2 2 . 5 2 ( N W ) EXISTING GROUND @ PIPE CL FINISHED GRADE @ PIPE CL MW S - 6 7 , T Y P E D U N I T BT 1 2 0 - C - S T C ST A . 6 1 0 + 8 8 . 7 0 , 2 3 . 5 3 ' R T RI M 2 4 . 3 0 16 " I E ( I N ) 2 1 . 1 0 ( N E ) 18 " I E ( O U T ) 2 0 . 5 5 ( S W ) 20 1 - 0 7 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 3 + 2 9 . 0 0 , 1 4 . 1 7 ' R T RI M 2 6 . 8 1 6" I E ( I N ) 2 4 . 0 0 ( N E ) 12 " I E ( O U T ) 2 3 . 0 0 ( N W ) 134 LF 12" SD @ 0.76% 20 1 - 3 1 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - S T C ST A . 6 1 0 + 8 5 . 6 4 , 3 6 . 7 4 ' R T RI M 2 4 . 4 6 18 " I E ( I N ) 2 0 . 5 2 ( N E ) 18 " I E ( I N ) 2 0 . 5 2 ( S W ) 18 " I E ( O U T ) 2 0 . 5 2 ( N W ) 12 LF 18" DI @ 0.26% 10 LF 16" DI @ 0.40% 61 LF 12" SD @ 0.79% 20 1 - 5 3 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 1 + 3 4 . 2 7 , 1 4 . 1 7 ' R T RI M 2 4 . 2 8 12 " I E ( I N ) 2 1 . 5 0 ( S E ) 6" I E ( I N ) 2 2 . 0 0 ( N E ) 12 " I E ( O U T ) 2 1 . 5 0 ( N W ) 49 LF 12" DI @ 0.74% 20 1 - 1 6 , C B T Y P E 1 L BT 1 2 0 - C - S T C ST A . 6 1 0 + 8 5 . 6 4 , 1 4 . 1 7 ' R T RI M 2 3 . 6 7 12 " I E ( I N ) 2 1 . 1 4 ( S E ) 12 " I E ( I N ) 2 1 . 1 4 ( N ) 8" I E ( I N ) 2 1 . 1 4 ( W ) 16 " I E ( O U T ) 2 1 . 1 4 ( S W ) 10 15 20 25 30 35 40 10 15 20 25 30 35 40 27 . 5 ' 27 . 4 2 ' 27 . 4 26 . 9 5 27 . 2 ' 27 . 1 3 ' 26 . 8 26 . 9 2 27 . 2 26 . 7 9 28 . 4 26 . 6 7 29 . 0 ' 27 . 0 3 ' 27 . 6 27 . 1 9 '' 20 3 - 7 4 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 3 + 7 0 . 8 1 , 1 8 3 . 6 2 ' R T RI M 2 6 . 9 8 12 " I E ( O U T ) 2 3 . 8 5 ( S W ) 45 LF 12" DI @ 0.51% 20 3 - 7 2 , C B T Y P E 1 L BT 1 2 0 - C - G R A D Y ST A . 1 5 3 + 9 6 . 9 2 , 2 1 4 . 1 4 ' L T RI M 2 6 . 9 2 12 " I E ( I N ) 2 3 . 6 2 ( N E ) 12 " I E ( O U T ) 2 3 . 6 2 ( S ) 63 LF 12" SD @ 1.88% 20 5 - 7 6 , C B T Y P E 1 L BT 1 2 0 - C - R A I L A K D W ST A . 7 1 6 + 1 1 . 1 5 , 9 3 . 4 4 ' R T RI M 2 6 . 6 1 12 " I E ( I N ) 2 2 . 4 3 ( N ) 8" I E ( I N ) 2 2 . 8 3 ( E ) 12 " I E ( O U T ) 2 1 . 6 1 ( E ) EXISTING GROUND @ PIPE C FINISHED GRADE @ PIPE C L L 20 3 - 4 6 , C B T Y P E 2 - 6 0 " BT 1 2 0 - C - R A I L A K D W ST A . 7 1 6 + 1 0 . 4 1 , 5 7 . 6 4 ' R T RI M 2 7 . 1 8 30 " I E ( I N ) 1 9 . 5 3 ( E ) 12 " I E ( I N ) 2 1 . 0 3 ( S ) 30 " I E ( O U T ) 1 9 . 5 3 ( W ) 20 3 - 4 5 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - R A I L A K D W ST A . 7 1 6 + 2 8 . 1 8 , 7 9 . 7 3 ' R T RI M 2 7 . 1 5 12 " I E ( I N ) 2 1 . 3 5 ( W ) 12 " I E ( O U T ) 2 1 . 3 5 ( N ) 22 LF 12" SD @ 1.19% 28 LF 12" SD @ 1.13% SCALE IN FEET 02.5 55 10 (1" = 5') 20 40 SCALE IN FEET 01020 (1" = 20') (HOR.)(VERT.) 201-16 TO 201-27 SCALE 1" = 20' H, 1" = 5' V 201-48 TO 203-71 SCALE 1" = 20' H, 1" = 5' V 201-31 TO 201-07 SCALE 1" = 20' H, 1" = 5' V 203-74 TO 203-46 SCALE 1" = 20' H, 1" = 5' V No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 07 / 1 3 / 2 6 | 4: 2 7 P M | SA K S H I G C: \ P W W O R K I N G \ J A C O B S _ B & I \ S A K S H I G @ O S B O R N C O N S U L T I N G . C O M \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - C D V 2 0 1 - 2 0 7 . D W G S1-BT120-CDV201-207 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-CDV001 GB-SEAL-SS56324 OSBORN CONSULTINGINCORPORATED STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER BT120-CDV202 BT120 174 B S. SRIDHARAN H. ONG R. PARISH S. SRIDHARAN 0 12/10/2024 SS RP SS ISSUED FOR BID 1 06/13/2025 SS RP SS ADDENDUM #1 B 05/04/2026 SS RP SS CNWD# 010 C 07/01/2026 SS RP SS FC #8 RTA/CN 0205-24 1"=20' C 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332150 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332151 10 15 20 25 30 35 40 10 15 20 25 30 35 40 ''25 . 6 ' 25 . 6 3 ' 24 . 7 24 . 6 7 '' MW S - 6 6 , T Y P E D U N I T BT 1 2 0 - C - R A I N I E R ST A . 2 0 7 + 8 5 . 0 5 , 6 . 9 2 ' R T RI M 2 5 . 5 5 12 " I E ( I N ) 2 1 . 9 3 ( N W ) 12 " I E ( O U T ) 2 1 . 4 1 ( E ) 4 LF 12" SD @ 0.53% 10 2 - 1 7 , C B T Y P E 1 L BT 1 2 0 - C - R A I N I E R ST A . 2 0 7 + 8 6 . 0 9 , 1 . 3 6 ' R T RI M 2 4 . 9 7 12 " I E ( O U T ) 2 1 . 9 5 ( S E ) 42 LF 12" DI @ 0.50% EX . 2 0 1 - 0 1 , E X . C B BT 1 2 0 - C - S T C ST A . 6 1 0 + 6 8 . 3 6 , 1 2 0 . 0 5 ' L T RI M 2 4 . 0 0 12 " I E ( I N ) 2 1 . 2 0 ( W ) 18 " I E ( I N ) 2 0 . 7 0 ( N E ) 18 " I E ( O U T ) 2 0 . 7 0 ( S W ) EX . EX . L EXISTING GROUND @ PIPE C 10 15 20 25 30 35 40 10 15 20 25 30 35 40 ''27 . 8 ' 27 . 7 0 ' 27 . 9 27 . 3 7 27 . 9 26 . 8 4 25 . 9 26 . 4 8 26 . 1 ' 26 . 1 8 ' 26 . 0 26 . 3 3 25 . 9 26 . 5 9 25 . 8 26 . 3 1 25 . 8 ' 25 . 8 8 ' 25 . 8 25 . 9 4 25 . 6 25 . 6 3 25 . 4 25 . 5 6 '''' 20 2 - 8 0 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - N T C ST A . 5 1 7 + 6 4 . 3 4 , 2 9 . 3 9 ' L T RI M 2 7 . 4 8 12 " I E ( I N ) 2 0 . 7 6 ( N W ) 12 " I E ( O U T ) 2 0 . 7 6 ( E ) FINISHED GRADE @ PIPE CL EXISTING GROUND @ PIPE CL 10 6 - 3 0 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - N T C ST A . 5 1 7 + 9 2 . 6 5 , 2 9 . 5 0 ' L T RI M 2 7 . 1 1 12 " I E ( I N ) 2 0 . 5 6 ( W ) 12 " I E ( O U T ) 2 0 . 5 6 ( E ) 28 LF 12" SD @ 0.71% 38 LF 12" SD @ 0.71% 60 LF 12" SD @ 0.50%128 LF 12" SD @ 0.50% 10 6 - 2 1 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - L A K E ST A . 4 0 4 + 2 5 . 2 0 , 1 9 . 9 6 ' L T RI M 2 6 . 1 6 12 " I E ( I N ) 2 0 . 2 9 ( W ) 12 " I E ( O U T ) 2 0 . 2 9 ( S ) 10 6 - 2 0 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - L A K E ST A . 4 0 3 + 6 6 . 4 0 , 2 5 . 1 7 ' L T RI M 2 6 . 5 9 12 " I E ( I N ) 1 9 . 9 9 ( N ) 12 " I E ( O U T ) 1 9 . 9 9 ( S ) EX . P I P E 10 6 - 3 8 , C B T Y P E 2 - 6 0 " BT 1 2 0 - C - L A K E ST A . 4 0 2 + 3 0 . 5 7 , 2 5 . 5 8 ' L T RI M 2 5 . 6 4 24 " I E ( I N ) 1 9 . 3 0 ( E ) 27 " I E ( O U T ) 1 9 . 2 0 ( W ) 10 6 - 3 9 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - L A K E ST A . 4 0 2 + 3 5 . 0 1 , 1 5 . 6 6 ' L T RI M 2 5 . 1 0 24 " I E ( I N ) 1 9 . 3 5 ( E ) 12 " I E ( I N ) 1 9 . 3 5 ( N ) 24 " I E ( O U T ) 1 9 . 3 5 ( W ) 11 LF 24" SD @ 0.45% 1" E X E 10 15 20 25 30 35 40 10 15 20 25 30 35 40 ''26 . 7 ' 26 . 7 2 ' 26 . 6 26 . 5 9 26 . 8 26 . 8 1 28 . 0 28 . 0 4 '' 20 1 - 1 0 , C B T Y P E 1 L BT 1 2 0 - C - S T C ST A . 6 1 2 + 5 7 . 1 5 , 4 0 . 3 3 ' R T RI M 2 6 . 2 3 12 " I E ( I N ) 2 2 . 4 8 ( S W ) 12 " I E ( I N ) 2 2 . 4 8 ( S E ) 12 " I E ( O U T ) 2 2 . 4 8 ( N W ) 20 3 - 1 1 , C B T Y P E 1 L BT 1 2 0 - C - S T C ST A . 6 1 2 + 5 0 . 4 8 , 6 1 . 8 3 ' R T RI M 2 6 . 5 8 12 " I E ( I N ) 2 2 . 8 2 ( S W ) 12 " I E ( O U T ) 2 2 . 8 2 ( N E ) 23 LF 12" SD @ 1.51% 55 LF 12" SD @ 0.51% 20 3 - 5 7 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 2 + 4 9 . 0 6 , 1 1 6 . 5 9 ' R T RI M 2 7 . 6 2 12 " I E ( O U T ) 2 3 . 1 0 ( N E ) L FINISHED GRADE @ PIPE C L EXISTING GROUND @ PIPE C 10 15 20 25 30 35 40 10 15 20 25 30 35 40 ''27 . 2 ' 27 . 5 2 ' 27 . 2 27 . 5 8 26 . 8 27 . 6 9 26 . 1 27 . 5 1 25 . 9 ' 27 . 4 3 ' 26 . 0 28 . 1 3 26 . 3 27 . 8 7 26 . 5 28 . 1 5 26 . 5 ' 28 . 4 7 ' 26 . 6 28 . 8 0 26 . 6 29 . 1 2 26 . 7 29 . 4 1 26 . 8 ' 29 . 5 5 ' 26 . 8 29 . 5 2 26 . 9 29 . 3 3 26 . 9 29 . 0 2 27 . 0 ' 28 . 6 9 ' 27 . 4 28 . 3 7 27 . 9 28 . 0 6 27 . 9 27 . 7 3 27 . 5 ' 27 . 4 1 ' 27 . 4 27 . 0 9 27 . 6 26 . 6 2 '' 20 2 - 2 6 , C B T Y P E 1 L BT 1 2 0 - C - S T C ST A . 6 1 4 + 0 5 . 2 3 , 2 2 . 1 1 ' R T RI M 2 7 . 6 0 12 " I E ( I N ) 2 4 . 4 7 ( S ) 12 " I E ( O U T ) 2 4 . 4 7 ( E ) FI L - 8 , T Y P E C U N I T BT 1 2 0 - C - S T C ST A . 6 1 5 + 5 7 . 8 2 , 1 9 . 4 7 ' R T RI M 2 9 . 5 3 12 " I E ( I N ) 2 3 . 3 0 ( W ) 6" I E ( I N ) 2 3 . 5 5 ( N ) 12 " I E ( O U T ) 2 3 . 2 3 ( E ) 20 4 - 2 7 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 4 + 0 3 . 2 1 , 6 9 . 1 5 ' R T RI M 2 7 . 3 7 12 " I E ( I N ) 2 4 . 7 2 ( S W ) 6" I E ( I N ) 2 5 . 2 2 ( N W ) 12 " I E ( O U T ) 2 4 . 7 2 ( N ) FINISHED GRADE @ PIPE CL EXISTING GROUND @ PIPE CL20 2 - 6 1 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 4 + 0 6 . 1 7 , 4 4 . 4 1 ' R T RI M 2 7 . 5 6 12 " I E ( I N ) 2 4 . 5 9 ( S ) 6" I E ( I N ) 2 5 . 0 9 ( N W ) 12 " I E ( O U T ) 2 4 . 5 9 ( N ) 10 6 - 2 8 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 8 + 0 6 . 1 6 , 1 8 . 1 5 ' R T RI M 2 6 . 7 9 12 " I E ( I N ) 2 2 . 4 5 ( N ) 12 " I E ( I N ) 2 2 . 4 5 ( E ) 12 " I E ( O U T ) 2 2 . 4 5 ( W ) 25 LF 12" DI @ 0.52% 22 LF 12" DI@ 0.54% 94 LF 12" SD @ 0.53% 10 6 - 5 6 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 8 + 3 6 . 2 5 , 1 8 . 1 7 ' R T RI M 2 6 . 2 0 12 " I E ( O U T ) 2 2 . 9 3 ( W ) 30 LF 12" SD @ 1.60% 20 3 - 8 3 , C B T Y P E 1 BT 1 2 0 - C - S T C ST A . 6 1 3 + 8 9 . 1 7 , 1 2 5 . 1 0 ' R T RI M 2 7 . 5 8 12 " I E ( I N ) 2 5 . 0 3 ( S ) 6" I E ( I N ) 2 5 . 5 3 ( N W ) 12 " I E ( O U T ) 2 5 . 0 3 ( N E ) 20 3 - 8 2 , C B T Y P E 1 , S E E D E T A I L C D D 5 0 7 FO R C A T C H B A S I N O I L - D E B R I S H O O D BT 1 2 0 - C - S T C ST A . 6 1 3 + 9 2 . 3 0 , 1 5 1 . 9 2 ' R T RI M 2 7 . 5 2 6" I E ( I N ) 2 5 . 6 7 ( N W ) 6" I E ( I N ) 2 5 . 6 7 ( S W ) 12 " I E ( O U T ) 2 5 . 1 7 ( N ) 28 LF 12" DI @ 0.51% 61 LF 12" DI @ 0.51% PROP 8" SS IE 18.58 157 LF 12" DI @ 0.74% 12 LF 12" SD @ 0.81% FI L - 1 0 , T Y P E C U N I T BT 1 2 0 - C - S T C ST A . 6 1 7 + 1 2 . 4 1 , 1 8 . 4 3 ' R T RI M 2 8 . 0 9 12 " I E ( I N ) 2 1 . 9 5 ( E ) 12 " I E ( O U T ) 2 1 . 6 0 ( W ) 20 2 - 2 4 , C B T Y P E 2 - 4 8 " BT 1 2 0 - C - S T C ST A . 6 1 7 + 0 0 . 0 5 , 1 9 . 0 0 ' R T RI M 2 8 . 2 4 12 " I E ( I N ) 2 1 . 5 0 ( W ) 12 " I E ( I N ) 2 1 . 5 0 ( E ) 12 " I E ( O U T ) 2 1 . 5 0 ( S ) 142 LF 12" SD @ 1.22% SCALE IN FEET 02.5 55 10 (1" = 5') 20 40 SCALE IN FEET 01020 (1" = 20') (HOR.)(VERT.) 102-17 TO EX. 201-01 SCALE 1" = 20' H, 1" = 5' V 202-80 TO 106-38 SCALE 1" = 20' H, 1" = 5' V 201-10 TO 203-57 SCALE 1" = 20' H, 1" = 5' V 203-82 TO 106-56 SCALE 1" = 20' H, 1" = 5' V No.DATE DSN CHK APP REVISION SUBMITTED BY:DATE:REVIEWED BY:DATE:DATE: CONTRACT No.: FILENAME: SCALE:DRAWING No.: SHEET No.:REV: LI N E I S 1 " A T FU L L S C A L E DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: 07 / 1 3 / 2 6 | 4: 2 3 P M | SA K S H I G C: \ P W W O R K I N G \ J A C O B S _ B & I \ S A K S H I G @ O S B O R N C O N S U L T I N G . C O M \ D 0 4 3 6 1 2 0 \ S 1 - B T 1 2 0 - C D V 2 0 1 - 2 0 7 . D W G S1-BT120-CDV201-207 FACILITY ID: Xrefs: xBRT-CUD05-TB22x34 xS1-BT120-CDV001 GB-SEAL-SS56324 OSBORN CONSULTINGINCORPORATED STRIDE BUS RAPID TRANSIT SOUTH RENTON TRANSIT CENTER BT105 R. PARGAS 12/10/2024 J. ALTCHECH 12/10/2024 12/10/2024 CIVIL DRAINAGE PROFILE S RENTON TRANSIT CENTER BT120-CDV205 BT120 177 B S. SRIDHARAN H. ONG R. PARISH S. SRIDHARAN 0 12/10/2024 SS RP SS ISSUED FOR BID 1 06/13/2025 SS RP SS ADDENDUM #1 A 06/19/2026 SS RP SS CNWD #0017 B 07/01/2026 SS RP SS FC #8 RTA/CN 0205-24 1"=20' B 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332153 30 35 FI L - 3 , T Y P E C U N I T BT 1 2 0 - C - H A R D I E ST A . 3 0 9 + 0 4 . 9 4 , 3 7 . 1 1 ' R T RI M 2 5 . 1 8 8" I E ( O U T ) 2 0 . 6 1 ( E ) 7-15-2026 DEVELOPMENT ENGINEERING msippo 07/22/2026 TE D - 4 0 - 4 3 3 2 C2 4 0 0 2 1 2 3 LU A 2 4 - 0 0 0 2 3 3 PR 2 1 - 0 0 0 0 9 5 R-4332154