Loading...
HomeMy WebLinkAboutRS_Geotechnical_Response_Secondary_Review_180814.pdfTERRA ASSOCIATES, Inc. Consultants in Geotechnical Engineering, Geology and Environmental Earth Sciences August 14, 2018 Project No. T-7677 Mr. Kyle Lublin Pulte Homes of Washington, Inc. 3535 Factoria Blvd SE, Suite 110 Bellevue, Washington 98006 Subject: Response to Comments Forest Terrace 2611 Union Avenue NE Renton, Washington Reference: 1. Geotechnical Report, Vandermay, 2611 Union Avenue NE, Renton, Washington, Project No. T-7677, prepared by Terra Associates, Inc., dated July 19, 2017 2. Protected Slope Analysis, Forest Terrace, 2611 Union Avenue NE, Renton, Washington, Project No. T-7677, prepared by Terra Associates, Inc., dated June 14, 2018, revised June 18, 2018 3. Geotechnical Engineering Review, Forest Terrace, Renton, Washington, File No. 0693-082-00, prepared by GeoEngineers, dated August 7, 2018 Dear Mr. Lublin: We have reviewed comments received from the City of Renton regarding geotechnical recommendations contained in the referenced design reports. The comments are summarized in the referenced letter to the City of Renton from GeoEngineers. The following is our response to the comments in the order listed in their letter. Comment] As recommended, we have reviewed the Washington State Department of Transportation Geotechnical Design Manual (WSDOT GDM) and have revised our analysis to follow the recommendations in Chapter 7. Based on our review of Chapter 6, it appears that the seismic analysis is not necessary for this slope. As such, we have removed the seismic portion of our analysis. 12220 113th Avenue NE, Ste. 130, Kirkland, Washington 98034 Phone (425) 821-7777 • Fax (425) 821-4334 Mr. Kyle Lublin August 14, 2018 Comment 2 We have prepared a figure that shows the details of the proposed cut rockeries for the Forest Terrace project. The figure shows the proposed height, minimum width, batter, drainage, and embedment of the rockeries. The figure is attached to this response letter. Comment 3 Based on our review of Chapter 6 of the WSDOT GDM, a seismic analysis is not required for this slope. Therefore, we have revised our analysis to follow the WSDOT GDM and have removed the seismic portion from our slope stability results. Comment 4 We have been retained by Pulte Homes of Washington, Inc. to observe construction. We will pay careful attention to the cut rockeries to ensure the soil conditions are as expected. If soil conditions vary from what was observed in the test pits, we will work with Pulte to ensure the rockeries and the slope meet the requirements of the approved plans. Comment 5 We have revised the slope stability analysis and have included the additional potential failure surfaces as requested. The results of the analysis indicate the slope remains stable in the post construction condition. We would note that one result shows a factor of safety of 1.22; however, this failure surface is through the face of the rockery only and does not include the overall slope. We have included this analysis to show the necessity of moving the limits of the analysis around to gain useful failure surfaces that include the overall slope, as well as the rockeries. The additional results are attached to this letter. Comment 6 We acknowledge that the advance outwash soils will be susceptible to erosion and we will work with Pulte and the contractor to ensure all necessary measures are taken onsite to ensure long term slope stability. Comment 7 The embedment for the rockeries is shown on the attached rockery detail and will be a minimum of 1.5 feet below the adjacent grade. The embedment was not modeled because we are not relying on the embedment for overall stability; we are only relying on the embedment to protect the foundation of the rockery from being undermined. Comment 8 As shown on the attached figure, the rockeries will be constructed with a 1:6 (Horizontal: Vertical) batter. Project No. T-7677 Page No. 2 Mr. Kyle Lublin August 14, 2018 Comment 9 We have included a filter fabric to be placed between the cut slope and the 12 inch drainage column that will be constructed behind the rockeries. This should be sufficient to prevent soil migration from the sand outwasb to the drainage column. We trust the information presented is sufficient for your current needs. If you have any questions or require additional information, please call. Sincerely MAno 14 S �9 . _ og-14 Zoog Carolyn 4?66 Cta Project E 6jSTR'�eeckerny /ON Enclosed: Figu Details Slide Output Project No. T-7677 Page No. 3 2(MAX) 1� 1' COMPACTED STRUCTURAL FILL ABOVE DRAIN COLUMN (TYP.) 4' MAX6 V CRUSHED ROCK FILTER MATERIAL, BETWEEN 2 AND 4 INCH SIZE WITH LESS THAN 2% FINES WIDE DRAIN COLUMN (TYP.) 5' MAX. 2(MAX) H/3 1.5' (MIN.) V MIN. 1 i 4' MAX 6 DENSE NATIVE SOILS (TYP.) WRAP DRAINAGE COLUMN IN MIRAFI 140N FILTER FABRIC OR EQUIVALENT (TYP.) (MIN.) COMPETENT NATIVE SOIL TO BE /I- KEYWAY -1 VERIFIED BY GEOTECHNICAL J ENGINEER 4" MINIMUM DIAMETER KEYWAY SHOULD BE SLOPED DRAIN PIPE SURROUNDED BY DOWN TOWARDS THE FACE CLEAN WASHED 3/4" DRAIN BEING PROTECTED POINT OF DISCHARGE (TYP.) NOT TO SCALE ROCKERY NOTES: 1. ROCKERY CONSTRUCTION SHALL BE COMPLETED IN ACCORDANCE WITH THE ASSOCIATION OF ROCKERY (ARC) CONTRACTORS GUIDELINES. 2. ROCK USED MUST MEET THE REQUIREMENTS FOR ROCK QUALITY SPECIFIED IN SECTIONS 9-13.7(1) OF THE WSDOT STANDARDS SPECIFICATIONS (2004). 3. ALL CAP ROCKS MUST BE SECURE AND NOT ABLE TO BE DISLODGED BY HAND. SLIDE OUTPUT Q8 09 6v U C v !6 U O Q E N >:. �p O N U c0 L N E J U) 7 2 ro > C _O 'd c F ? L LL 7 C a° N a 0 L v 0 U C 0 N � g v I j� C U C N ++ U E (A w a� m ` 0 0 0 z z z N ty a a m m v i N N D U 0 ,-4 O N pp � 0 t a o o Ln 0 U 0 0 E. F. r00 00 00 vo U U U C i H a+ m M 3 o LM C-4 Ln N 'c — �V -8 ❑ m ■ r — C m LL m z > > o O +� u Z ate+ C N u K Q z 0, L I Cl N O If oti6 oz6 0% 09 — 09. ob U C N ++ U E (A a� N tn E J 7tn O LL in C O U o 0_ M N a 0 ri i N N D U 0 ,-4 O N pp � I m � ■1 ; f q Q k \ k / / k ) ) \ ) k \ \ \ 10 ƒ \ / \ 0 a 2 2 \ \ § g § . .0 . MIN E \ \10 2 : § ) \ } ) 09 oto - % B G \ J C) k A 8/13/2018 192942156.htm Slide Analysis Information Roadway Project Summary File Name: Roadway.slmd Slide Modeler Version: 8.016 Project Title: Forest Terrace Analysis: Post Construction - Various Limits Author: C. Decker Company: Terra Associates, Inc. Date Created: 6/8/2018, 3:14:01 PM Currently Open Scenarios Group Name Scenario Name Global Minimum Compute Time Post Construction Master Scenario Bishop Simplified: 1.224330 00h:00m:01.488s Janbu Simplified: 1.274310 Upper Slope Condition Master Scenario Bishop Simplified: 1.387200 00h:00m:00.876s Janbu Simplified: 1.326200 oMaster Scenario Bishop Simplified: 1.392110 00h:00m:00.933s Post Construction -Slope Limits Janbu Simplified: 1.339530 General Settings Units of Measurement: Imperial Units Time Units: days Permeability Units: feet/second Data Output: Standard Failure Direction: Right to Left Analysis Options file:///C:/Users/cdecker/AppData/LocallTemp/RocscienceTempSlidelnterpret_7/192942156.htm 1/5 8/13/2018 All Open Scenarios Slices Type: Vertical Analysis Methods Used Bishop simplified Janbu simplified Number of slices: 50 Tolerance: 0.005 Maximum number of iterations: 75 Check malpha < 0.2: Yes Create Interslice boundaries at intersections Yes with water tables and piezos: None Initial trial value of FS: 1 Steffensen Iteration: Yes Groundwater Analysis All Open Scenarios Groundwater Method: Water Surfaces Pore Fluid Unit Weight [lbs/ft3]: 62.4 Use negative pore pressure cutoff: Yes Maximum negative pore pressure [psf]: 0 Advanced Groundwater Method: None Random Numbers All Open Scenarios Pseudo -random Seed: 10116 Random Number Generation Method: Park and Miller v.3 Surface Options 192942156.htm file:///C:/Users/cdecker/AppData/Local/Temp/RocscienceTempSlidelnterpret_7/192942156.htm 2/5 8/13/2018 All Open Scenarios Advance Outwash Surface Type: Circular Search Method: Auto Refine Search Divisions along slope: 20 Circles per division: 10 Number of iterations: 10 Divisions to use in next iteration: 50% Composite Surfaces: Disabled Minimum Elevation: Not Defined Minimum Depth: Not Defined Minimum Area: Not Defined Minimum Weight: Not Defined Seismic Loading All Open Scenarios Advanced seismic analysis: No Staged pseudostatic analysis: No Materials 192942156.htm Property Advance Outwash New Structural Fill Rockery Rocks Color Ll r il Strength Type Mohr -Coulomb Mohr -Coulomb Mohr -Coulomb Unit Weight [lbs/ft3] 120 125 125 Cohesion [psf] 0 0 75 Friction Angle [°] 38 34 45 Water Surface Assigned per scenario Assigned per scenario Assigned per scenario Ru Value 0 0 0 Materials In Use Material Master Scenario 0 Master Scenario 0 Master Scenario Advance Outwash❑ New Structural Fill ❑ Rockery Rocks ❑ Global Minimums file:///C:/Users/cdecker/AppData/Local/Temp/RocscienceTempSlidelnterpret_7/192942156.htm 3/5 8/13/2018 192942156.htm Post Construction 0 Upper Slope Condition 0 Post Construction - Slope Limits a Method: bishop simplified Method: bishop simplified Method: bishop simplified FS 1.224330 FS 1.387200 FS 1.392110 Center: 72.466, Center: 47.479, Center: 61.599, Right Slip Surface 96.348 Endpoint: 144.965 Left Slope 124.794 Radius: 18.656 Radius: 73.183 Radius: 49.219 Left Slip Surface 88.000, Left Slip Surface 77.000, Left Slip Surface 77.000, Endpoint: 86.016 Endpoint: 78.000 Endpoint: 78.047 Right Slip Surface 90.009, Right Slip Surface 99.998, Right Slip Surface 99.991, Endpoint: 90.000 Endpoint: 93.999 Endpoint: 93.995 Left Slope 88.000 Left Slope 77.000 Left Slope 77.000 Intercept: 90.000 Intercept: 82.000 Intercept: 82.000 Right Slope 90.009 Right Slope 99.998 Right Slope 99.991 Intercept: 90.000 Intercept: 93.999 Intercept: 93.995 Resisting Moment: 10937.2 Resisting Moment: 412138 lb- Resisting Moment: 323243 I b - Ib -ft ft ft Driving Moment: 8933.19 Driving Moment: 297100 Ib- Driving Moment: 232195 lb - Ib -ft ft ft Total Slice Area: 4.40107 Total Slice Area: 61.2975 ft2 Total Slice Area: 73.4564 ft2 ft2 Surface Horizontal 22.9978 ft Surface Horizontal 22.991 ft Surface Horizontal 2.00925 ft Width: Width: Width: Surface Average 2.66537 ft Surface Average 3.19501 ft Surface Average 2.19041 ft Height: Height: Height: Method: janbu simplified FS 1.274310 Center: 72.466, 96.348 Radius: 18.656 Left Slip Surface 88.000, Endpoint: 86.016 Right Slip Surface 90.009, Endpoint: 90.000 Left Slope 88.000 Intercept: 90.000 Right Slope 90.009 Intercept: 90.000 Resisting Horizontal 289.197 lb Force: Driving Horizontal 226.943 Ib Force: Total Slice Area: 4.40107 ft2 Surface Horizontal 2.00925 ft Width: Surface Average 2.19041 ft Height: Method: janbu simplified FS 1.326200 Center: 75.776, 97.626 Radius: 20.063 Left Slip Surface 71.615, Endpoint: 78.000 Right Slip Surface 94.857, Endpoint: 91.429 Resisting Horizontal 5868.21 Ib Force: 82.000 Driving Horizontal 4424.841b Force: 93.367 Total Slice Area: 83.0335 ft2 Surface Horizontal 23.2418 ft Width: Surface Average 3.5726 ft Height: Method: janbu simplified FS 1.339530 Center: 66.167, 116.382 Radius: 39.879 Left Slip Surface 77.000, Endpoint: 78.003 Right Slip Surface 98.734, Endpoint: 93.367 Left Slope 77.000 Intercept: 82.000 Right Slope 98.734 Intercept: 93.367 Resisting Horizontal 5518.91 Ib Force: Driving Horizontal 4120.03 Ib Force: Total Slice Area: 73.9007 ft2 Surface Horizontal 21.7337 ft Width: Surface Average 3.40028 ft Height: file:///C:/Users/cdecker/AppData/Local/Temp/RocscienceTempSlidelnterpret_7/192942156.htm 4/5 8/13/2018 Valid/Invalid Surfaces Post Construction 0 Method: bishop simplified Number of Valid Surfaces: 11357 Number of Invalid Surfaces: 22 Error Codes: Error Code -112 reported for 22 surfaces Method: janbu simplified Number of Valid Surfaces: 11264 Number of Invalid Surfaces: 115 Error Codes: Error Code -108 reported for 115 surfaces 192942156.htm Upper Slope Condition 0 Method: bishop simplified Number of Valid 5984 Surfaces: Number of Invalid 0 Surfaces: Method: janbu simplified Number of Valid 5984 Surfaces: Number of Invalid 0 Surfaces: Post Construction - Slope Limits 0 Method: bishop simplified Number of Valid Surfaces: 6819 Number of Invalid Surfaces: 24 Error Codes: Error Code -112 reported for 24 surfaces Method: janbu simplified Number of Valid Surfaces: 6842 Number of Invalid Surfaces: 1 Error Codes: Error Code -108 reported for 1 surface Error Codes The following errors were encountered during the computation: -108 = Total driving moment or total driving force < 0.1. This is to limit the calculation of extremely high safety factors if the driving force is very small (0.1 is an arbitrary number). -112 = The coefficient M -Alpha = cos(alpha)(1+tan(alpha)tan(phi)/F) < 0.2 for the final iteration of the safety factor calculation. This screens out some slip surfaces which may not be valid in the context of the analysis, in particular, deep seated slip surfaces with many high negative base angle slices in the passive zone. file:///C:/Userslcdecker/AppData/Local/Temp/RocscienceTempSlidelnterpret_71192942156.htm 5/5