HomeMy WebLinkAboutCD-4024LINE EXISTING 12" WATER U4 ADJUSTED EXISTING MH TO BE VERIFY AND PROTECT EXISTING LIGHT TOWER STORMWATER DETENTION POND CONTOURS (TYP) MH TO MATCH EXISTING PIPE SLOPE EXTEND 36" STORM SEWER 129' TO PROPOSED SEWER EXISTING 36" STORM CUT LIMIT W W MHMHMHMH REV DATE DESCRIPTION BY APP DRAWN BY DESIGNED BY CHECKED BY APPROVED BY DATE SUB DRAWING NO. REVISION SCALE SHEET NO.File:12:10:54 PMDate:8/21/2018Time:Pen table:Plot driver:BNSF_Railway_pdf_half.pltcfgBNSF_Railway_Color.tblCOMPANY. AGREEMENTS WITH BNSF RAILWAY NOT PROVIDED FOR IN NOT BE USED FOR ANY PURPOSE HELD CONFIDENTIAL AND SHALL RAILWAY COMPANY AND SHALL BE REMAIN THE PROPERTY OF BNSF FURNISHED HEREWITH SHALL CATIONS, AND/OR INFORMATION ALL PLANS, DRAWINGS SPECIFI- INFORMATION CONFIDENTIAL OF SM PROJECT NO.User:Schro01204I:\12jobs\12R0048\CAD\Rail\Sheet\C-02-3001-Grading_PhaseII.dgnREV DATE DESCRIPTION BY APPSUB 3/13/2018 BNSF RAILWAY ORILLIA AUTOMOTIVE FACILITY EXPANSION GLACIER PARK, WA GRADING AND UTILITY PLAN 8/17/18 8/21/18 SHIFT S. POND, REMOVE STR., RELO. (P) WATER LINE AND HYDRANTS (WCD 2, 3) ADD WATERLINE INSTALL NOTES TO PLANS PER CITY REQUEST PWB PWB MGQ LJS AS SHOWN OF 56 12R0048 C-3001 12 100% PLANS LES LJS LJS C-3002MATCH LINE SHEET 0 100' GRAPHIC SCALE:1" = 100' 50'25'50' U2 U5 U6 U7 U8 U9 U11 U14U15 U17 MH U13 EXISTING FIRE HYDRANT EXISTING EDGE OF PAVEMENT LINE EXISTING 12" WATER EXISTING LIGHT TOWER EXISTING FIRE HYDRANT SEE NOTE 9 PROPOSED 1004' LENGTH ACCESS ROAD FILLEXISTING BNSF ROW STORM SEWER EXISTING 36" SYSTEM ALONG NORTH FENCE EXISTING SPRINKLER REMOVE & CAP END OF 131' SEE NOTE 8 FROM TOP EDGE OF POND LINE TO NEW HYDRANT, 10' INSTALL 446' OF 8" WATER 1 U3 10.00' 1 1 1 1 FILL TO EXISTING AND PROPOSED CASING PER WCD 5. TO MEET BNSF UTILITY ACCOMODATION POLICY. ADD SAND EXTEND EXISTING 26" CASING 29 LF REMOVAL OF CLEANING POLYPIG RENTON STANDARD PLAN NO 300.6 FOR 8"x8" VERTICAL CROSS (MJxFL) PER SEE NOTES 7 & 8 MIN. FROM NEW FENCE, BEHIND GUARD RAIL, 5' INSTALL NEW HYDRANT 3' CONCRETE BLOCK. VALVE (FLxMJ), (MJxFL), 6" TAPPING 12"x6" TAPPING TEE 1 2 2 2 CONCRETE BLOCK. VALVE (FLxMJ), (MJxFL), 8" TAPPING 12"x8" TAPPING TEE 2 EXISTING VALVES PER CITY STANDARD PLAN NO. 300.1 STANDARD VALVE BOX SHALL BE INSTALLED ON THE MANHOLE SHALL BE FILLED WITH CRUSHED ROCKS AND A REMOVED BY CITY FORCES. THE BOTTOM SECTION OF THE LINE ON THE SIDE OF THE EXISTING VALVES SHALL BE SHALL BE REMOVED. THE EXISTING 3/4" COPPER BY-PASS GRADE, THEN THE TOP CONE-SECTION OF THE MANHOLES VALVES CANNOT BE LOWERED TO MATCH THE NEW FINISHED IF COVERS OF THE EXISTING MANHOLES FOR THE 12" GATE 10. ROAD SHALL BE CONSTRUCTED ON EXISTING GRADE SEE DRAWING C-4005 FOR ACCESS ROAD DETAILS. ACCESS 9. DONE BY A CITY APPROVED WET-TAP CONTRACTOR WATER STANDARD PLAN 310.1. WET-TAPPING SHALL BE CONNECTIONS SHALL CONFORM TO THE CITY OF RENTON INSTALLATION AND REMOVAL OF HYDRANTS AND WATERLINE 8. RIM ELEVATIONS SEE CONSTRUCTION POINT DRAWING C-0001 FOR UTILITY 7. MANHOLE DETAILS SEE DRAWINGS H-1003 - H-1004 FOR SIPHON PIPE AND 6. SEE DRAWING G-0004 FOR YARD TYPICAL SECTION5. DETENTION POND GRADING DETAILS SEE DRAWINGS H-1001 - H-0003 FOR STORMWATER 4. SEE DRAWING C-4004 FOR PAVEMENT SECTIONS3. HORIZONTAL EDGE OF PAVEMENT GRADING LIMITS SEE DRAWINGS C-0002 & C-4001 - C-4003 FOR 2. SEE DRAWING C-0001 FOR UTILITY COORDINATES1. NOTES: 2 25' MIN. FROM NEW FENCE, SEE NOTE 7 & 8 INSTALL NEW HYDRANT 3' BEHIND GUARD RAIL, BLOCK. 8"x6" TEE (MJxFL), 6' G.V. (FLxMJ), CONC. 8" WATER CROSSING WITH 48" SD AT NEW VERIFY CONFLICT N18 18 18 18 18 18 18 18 18 19 19 19 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 21 21 21 21 21 21 21 21 21 21 21 21 21 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 2 2 22 22 22 22 22 2 2 2 2 22 22 22 22 22 22 22 22 22 22 22 22 22 U12 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 24 24 24 24 U1 EXISTING WATER VALVE x 2 LINE EXISTING 48" STORM SEE NOTE 6 PROPOSED SIPHON PIPE AND NEW MH EXISTING WATER VALVE x 2 TO BE ADJUSTED, SEE NOTE 7 & 8 2 7 , 8 & 10 TO BE ADJUSTED, SEE NOTE WATER UTILITY Abdoul Gafour 08/31/2018 W-402401WTR-274024BNSF AUTO UNLOADINGC18004904 REV DATE DESCRIPTION BY APP DRAWN BY DESIGNED BY CHECKED BY APPROVED BY DATE SUB DRAWING NO. REVISION SCALE SHEET NO.File:12:10:55 PMDate:8/21/2018Time:Pen table:Plot driver:BNSF_Railway_pdf_half.pltcfgBNSF_Railway_Color.tblCOMPANY. AGREEMENTS WITH BNSF RAILWAY NOT PROVIDED FOR IN NOT BE USED FOR ANY PURPOSE HELD CONFIDENTIAL AND SHALL RAILWAY COMPANY AND SHALL BE REMAIN THE PROPERTY OF BNSF FURNISHED HEREWITH SHALL CATIONS, AND/OR INFORMATION ALL PLANS, DRAWINGS SPECIFI- INFORMATION CONFIDENTIAL OF SM PROJECT NO.User:Schro01204I:\12jobs\12R0048\CAD\Rail\Sheet\P-02-1001-Pond.dgnREV DATE DESCRIPTION BY APPSUB 3/13/2018 BNSF RAILWAY ORILLIA AUTOMOTIVE FACILITY EXPANSION GLACIER PARK, WA STORMWATER DETENTION POND PLAN 1 2 8/17/18 8/21/18 REMOVE S. OVERFLOW, ADJ. FENCE LOCATION, POND SHIFT (WCD 2, 4) ADDED NOTE PER CITY REQUEST PWB PWB MGQ LJS AS SHOWN OF 56 12R0048 H-1001 15 100% PLANS LES LJS LJS 18 18 19 19 19 20 20 20 21 21 21 21 21 21 21 21 21 21 21 21 21 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 23 23 23 23 23 23 2 3 2 3 23 2 3 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 24 24 24 24 24 24 2 5 25 WWWWMHMHMHMHMHMHN0 100' GRAPHIC SCALE:1" = 100' 50'25'50' H-1003 B H-1003 C H-1003 A H-1002MATCH LINE SHEETH-1004 D H9 H10 H11 H12 H16 H15 H14 H13 H17 H18 H19 H20 H21 H22 H23 H24 H25 H27 H28 H26 H31 H29 H30 H32 JUNCTION BOX H73 H75 H76 H74 H79 H77 H78 H80 H81 H83H87 H85 H86 H88 H89 H91 H92 H90 H96 H93 H94 H95 H38 H37 H54 H55 H56 H39 H57 H58 H59 H40H52 H67 H66 H65 H64 H63 H62 H61 H60 H69 H70 H51 H44 H43 H42 H36 H35 H41 H34 H33 H46 H47 H48 H49 H50 H72 ACCESS RAMPACCESS RAMP CUT/FILL LIMIT R = 23' R = 20' R = 23' R = 28'R = 28' R = 23' R = 23' R = 24' R = 4' R = 4' R = 4' R = 4' EXISTING 48" RCP EXISTING 48" RCP H84 H82 COORDINATES SEE DRAWINGS C-3001 FOR STORMWATER STRUCTURE LOCATION 2. DETENTION POND SECTIONS AND DETAILS SEE DRAWINGS H-1003, H-1004, AND H-1005 FOR STORMWATER 1. NOTES: 0 20' DETAIL GRAPHIC SCALE:1" = 20' 10'5'10' SEE DETAIL SHEET H-1005 CONTROL STRUCTURE SEE DETAIL SHEET H-1005 OIL/WATER SEPARATOR SEE DETAIL SHEET H-1005 OVERFLOW STRUCTURE DETAILH-1001 F H-1001 F EXISTING 36" RCP H2 R = 23' H6 H1 H2H4 H3 H7 H123 H8 H125 H126 H127 H5 H122 H121 R = 23' H124 CUT LINE CUT LINE FILL LINE H-1004 E 48" RCP EXISTING STORM CULVERT EQUALIZATION 30" CPE EXISTING 12" WATER MAIN EXISTING 12" WATER MAIN EXISTING 12" WATER MAIN 1 1 BEHIND PROPOSED NEW FIRE HYDRANT ACCOMODATE FENCE BUMP OUT 6' FIELD ADJUST POND GRADING TO BEHIND PROPOSED NEW FIRE HYDRANT ACCOMODATE FENCE BUMP OUT 6' FIELD ADJUST POND GRADING TO BEHIND PROPOSED NEW FIRE HYDRANT ACCOMODATE FENCE BUMP OUT 6' FIELD ADJUST POND GRADING TO 1 1 1 STORM SEWER EXISTING 48" 1 ACCESS FOR MAINTENANCE 12" WATER MAIN FOR SOUTH SIDE OF EXISTING PROVIDE 7' WIDE PAD ON 2 WATER UTILITY Abdoul Gafour 08/31/2018 W-402402WTR-274024BNSF AUTO UNLOADINGC18004904 REV DATE DESCRIPTION BY APP DRAWN BY DESIGNED BY CHECKED BY APPROVED BY DATE SUB DRAWING NO. REVISION SCALE SHEET NO.File:12:10:57 PMDate:8/21/2018Time:Pen table:Plot driver:BNSF_Railway_pdf_half.pltcfgBNSF_Railway_Color.tblCOMPANY. AGREEMENTS WITH BNSF RAILWAY NOT PROVIDED FOR IN NOT BE USED FOR ANY PURPOSE HELD CONFIDENTIAL AND SHALL RAILWAY COMPANY AND SHALL BE REMAIN THE PROPERTY OF BNSF FURNISHED HEREWITH SHALL CATIONS, AND/OR INFORMATION ALL PLANS, DRAWINGS SPECIFI- INFORMATION CONFIDENTIAL OF SM PROJECT NO.User:Schro01204I:\12jobs\12R0048\CAD\Rail\Sheet\P-02-1003-Pond.dgnREV DATE DESCRIPTION BY APPSUB 3/13/2018 BNSF RAILWAY ORILLIA AUTOMOTIVE FACILITY EXPANSION GLACIER PARK, WA STORMWATER DETENTION POND SECTIONS 1 2 8/17/18 8/21/18 POND SHIFTED SOUTH , JCT BOX SIZE CHANGE, PIPE TYPES (WCD 2) ADJUST LINEWORK PER CITY REQUEST PWB PWB MGQ LJS AS SHOWN OF 56 12R0048 H-1003 17 100% PLANS LJS LJS H-1001 0 10' GRAPHIC SCALE:1" = 10' 5' 5' SECTION 0 100' HORIZONTAL SCALE:1" = 100' 50'25'50' 0 20' VERTICAL SCALE:1" = 20' 10'5'10' H-1001 SECTION ELEV. 22.00 SOUTH POND ELEV. 17.5 NORTH POND ELEV. 17.5 SOUTH POND ELEV. 17.5 ELEV. 22.00 -0.5%0.5%2:1NORTH POND ELEV. 17.5MATCHLINE 1MATCHLINE 1TOP ELEV. 21.0 TOP ELEV. 21.0 TOP ELEV. 22.1 0.5%-0.5%2:12:1 0.00% GRADE H-1001 SECTION CROWN ELEV. 22.10 CONNECT TO EXISTING 48" RCP (INVERT ELEV. 16.50) 66" CATCH BASIN OIL/WATER SEPARATOR EXISTING GROUND EXISTING GROUND EXISTING 48" RCP CROWN ELEV. 22.10 2:1 71.00'1.00'3.75'6.00'2.50'1.00'3.75'NORTH POND BOTTOM ELEV. 17.5SOUTH POND BOTTOM ELEV. 17.5 SOUTH POND BOTTOM ELEV. 17.5 C B A 6.00'POINT U12: ELEV. 18.5 EQUALIZER CULVERT POINT U11: ELEV. 18.5 EQUALIZER CULVERT POINT U7: LID ELEV. 22.75 CONTROL STRUCTURE POINT U8: LID ELEV. 22.75 JUNCTION MH POINT U13: LID ELEV. 22.75 OIL/WATER SEPARATOR STORM STRUCTURES SEE SHEET C-0001 FOR UTILITY COORDINATES OF 2. SEE DRAWING H-1005 FOR STORM SYSTEM DETAILS1. NOTES: 6.50'17.10' 6' X 12' JUNCTION BOX (MANHOLE SUBSTITUTED PER WCD 2)(MANHOLE SUBSTITUTED PER WCD 2) ELEV. 16.5) RCP (INVERT EXISTING 48" 93' PER WCD 2 IN-PLACE PROTECTED TO BE WATERLINE CITY MIN 7.5' OF ACCESS PAD ON EACH SIDE OF WATERMAIN SHIFT POND EDGE 8' SOUTH PER WCD 2 TO PROVIDE 1 1 1 1 30" CPE SIPHON (EQUALIZER) PER WCD 2 30" CPE CULVERT PER WCD 2 30" CPE CULVERT PER WCD 2 30" CPE INFLOW (INVERT ELEV. 18.00) PER WCD 2 1 1 1 1 2 WATER UTILITY Abdoul Gafour 08/31/2018 W-402403WTR-274024BNSF AUTO UNLOADINGC18004904