HomeMy WebLinkAboutS-0371209c\j LEGEND: ABBREVIATIONS SYMBOLS AND DESIGNATIONS
T
MO EXISTING PROPOSED AASHTO AMERICAN ASSOC. OF STATE MBMFR MANUFACTURER
HIGHWAY MH MANHOLE
RIGHT OF WAY BNSF PREMISES
r _---------"'--"'— TRANSPORTATION OFFICIALS MIN MINIMUM TITLE
N AB ANCHOR BOLT MON MONUMENT TITLE DETAIL NUMBER
— CENTERLINE — GRAVITY SEWER AC ASPHALT CONCRETE MUTCD MANUAL ON UNIFORM TRAFFIC DETAIL /
ACP ASPHALT CONCRETE PAVEMENT CONTROL DEVICES �
-- PROPERTY LINE SANITARY SEWER MANHOLE OR STRUCTURE ADS POLYETHYLENE PIPE MW MONITORING WELL SCALE. 1/2" - 1'-0" C-2
EASEMENT //////�/��/, TO BE REMOVED OR ABANDONED ALD ALDER ��— DRAWING NUMBER WHERE DETAIL
APPROX APPROXIMATE N NORTH IS REFERENCED. USE DASH IF
CONTOUR ASPHALT CONCRETE PAVEMENT (ACP) - PLAN APWA AMERICAN PUBLIC WORKS NAD NORTH AMERICAN DATUM DETAIL APPEARS ON THE SAME
ASSOCIATION NAVD NORTH AMERICAN VERTICAL DATUM SHEET AS SHEET REFERENCED.
AVE AVENUE NE NORTHEAST
Micp MONUMENT IN CASE PRE -CAST CONCRETE NIC NOT IN CONTRACT
MON o BC BF BLIND FLANGE NO. NUMBER TITLE SECTION, ELEVATION OR
SURFACE MONUMENT go O o O g CS BH BORE HOLE NTS NOT TO SCALE TITLE
BLVD BOULEVARD NW NORTHWEST PROFILE REFERENCE LETTER
PK NAIL BM BENCH MARK SECTION A
REBAR &CAP BNSF BURLINGTON NORTHERN SANTA FE OC ON CENTER SCALE: 1/2" - 1'-0"
OD OUTSIDE DIAMETER DASH IF SECTION IS TAKEN ON THE
CB CATCH BASIN OH OVERHEAD SAME DRAWING. USE DRAWING
SEWER MANHOLE CCW COUNTER CLOCK WISE OP OVERHEAD POWER NUMBER IF SECTION WAS TAKEN
CDF CONTROLLED DENSITY FILL OPG OPENING ON A DIFFERENT SHEET.
POWER POLE CF CLEARING LIMIT FENCE
POWER POLE W/UNDERGROUND CONNECT CHLK CHAIN LINK P POWER SECTION LETTER
CIPP CURED IN PLACE PIPE PE PLAIN END, PROFESSIONAL ENGINEER A -
C/L, CL CENTERLINE PG PERFORMANCE GRADE
GUY ANCHOR CLR CLEAR PSF POUNDS PER SQUARE FOOT C-1
CO CLEANOUT PSI POUNDS PER SQUARE INCH DRAWING NUMBER WHERE DETAIL CALLOUT
POWER MANHOLE CONIC CONCRETE PVC POLYVINYL CHLORIDE SECTION IS DRAWN. USE DASH IF
CPLG COUPLING PVMT PAVEMENT SECTION APPEARS ON SAME 4/C-1
TELEPHONE MANHOLE SHEET AS CUT.
CSBC CRUSHED SURFACING BASE COURSE PWR POWER
DRAWING #
CSTC CRUSHED SURFACING TOP COURSE
GAS VALVE RD ROAD ELEVATION LETTER
DETAIL #
WATER VALVE D/W DRIVEWAY REINF REINFORCEMENT A
D DEPTH, DOUBLE REQ'D REQUIRED
DBH DIAMETER BREAST HEIGHT RET RETAINING C-1
WATER METER DI DUCTILE IRON ROW, R/W RIGHT OF WAY DRAWING NUMBER WHERE ELEVATION IS
DIA DIAMETER RRC RED REBAR AND CAP DRAWN. USE DASH IF ELEVATION
WATER VAULT LID DIP DUCTILE IRON PIPE RT RIGHT APPEARS ON SAME SHEET AS
DIPS DUCTILE IRON PIPE SIZE REFERENCED.
FIRE HYDRANT DR DRIVE S SOUTH, SLOPE
DTREE DECIDUOUS TREE SCH SCHEDULE
BLOW -OFF DWG DRAWING SD STORM DRAIN
BORE SITE (W/ FIELD DESCRIPTION) SDMH STORM DRAIN MANHOLE PIPING DESIGNATIONS
E EAST, ELECTRICAL SDR STANDARD DIMENSION RATIO
EA EACH SE SOUTHEAST
MONITORING WELL EW EACH WAY SERV SERVICE
EL, ELEV ELEVATION SF SILT FENCE PIPING IS IDENTIFIED BY ITS SIZE FOLLOWED BY PIPING SYSTEM AS FOLLOWS:
GUARD POST EP EDGE OF PAVEMENT SSFM SANITARY SEWER FORCE MAIN
DESIGNATES NEW PIPING:
EX EXISTING SMH SEWER MANHOLE
SIGN SS SANITARY SEWER
FF FINSHED FLOOR SST STAINLESS STEEL 8" SS
SHRUB FIG FINISH GRADE ST STREET
PVC
FT,' FEET STA STATION
DECIDUOUS TREE, DIA (# OF TRUNKS) STD STANDARD
DESIGNATES EXISTING PIPING:
G GAS STL STEEL
PAINTED POWER GALV GALVANIZED SW SOUTHWEST
GRAY GRAVEL EX 8" CONC SS
PAINTED TELEPHONE GV GATE VALVE T TELEPHONE
T&B TOP AND BOTTOM
PAINTED FIBER OPTIC HDPE HIGH DENSITY POLYETHYLENE TBM TEMPORARY BENCHMARK FOR NEW PIPING MATERIAL, FITTINGS, AND VALVES, SEE SPECIFICATIONS. A
Q HMA HOT MIX ASPHALT TELJB TELEPHONE JUNCTION BOX GENERAL PIPING MATERIAL MAY BE NOTED.
PAINTED TV HORIZ HORIZONTAL TELR TELEPHONE RISER
HT HUB AND TACK TV TELEVISION (CABLE) PIPING SYSTEM DESIGNATIONS FOR EXISTING PIPING INDICATE TYPE OF
PAINTED WATER HYD HYDRANT TVJB TELEVISION (CABLE) JUNCTION BOX SERVICE AND TYPE OF MATERIAL IF KNOWN. CONTRACTOR SHALL VERIFY ALL
TVR TELEVISION (CABLE) RISER EXIST PIPE MATERIAL AND NOT RELY ON THIS DESIGNATION PRIOR TO
PAINTED GAS ID INSIDE DIAMETER TYP TYPICAL CONSTRUCTION.
IE INVERT ELEVATION
SEWER IN, " INCH UGP UNDERGROUND POWER
IPS IRON PIPE SIZE UNO UNLESS NOTED OTHERWISE
FENCE
JB JUNCTION BOX VCP VITRIFIED CLAY PIPE
RAISED -BUTTON SOLID STRIPE VERT VERTICAL DRAWING REFERENCE
L LENGTH
RAISED -BUTTON SKIP STRIPE LF LINEAR FEET W/ WITH
LN LANE W WATER, WEST G GENERAL
EDGE OF PAVEMENT LT LEFT WL WATER LEVEL
C CIVIL
WM WATER METER
CONCRETE MAX MAXIMUM WSDOT WASHINGTON STATE DEPARTMENT
MB MAIL BOX OF TRANSPORTATION
GRAVEL MDD MAXIMUM DRY DENSITY WS WATER SERVICE
0
I
N
m
p I
Q
pcl- cn
Call 48 Hours
Q Z
z Before You Dig
J S-0371209 1-800-424-5555
UNDERGROUND SERVICE
U
DES War S .
Uj P WA l F Wri DATE:
pN BHC Consultants, LLC ���I�l_ �.�{) 4,��i1r_,�� SURVEYED: SCALE:
1601 Fifth Avenue, Suite 500 ��tiP , �� '(•T DESIGNED: N/G, HORIZONTAL: NAD 1963/1991 �- CITY O C
�. !T' O _ VERTICAL AD 1 83/1 I CENTRAL RENTON SEWER INTERCEPTOR MAY 2015
RELINE & UPSIZE PROJECT FIELDBOOK:
. Seattle, Washington 98101 l C t ' T. WHITEHOUSE, P.E. R E N TO N PAGE:
t� _
206.505.3400 �'
DRAWN:
L A P. SIMON DRAWING N0:
w CONSULTANTS 49545 [L ONE INCH DATU M
206.505.3406 (fax) .po �o� R� �� o4 ISSUED FOR BID TJw 05/2015 ASK CHECKED: AT FULL SCALE Public works Dept. LEGEND, ABBREVIATIONS, SYMBOLS & DESIGNATIONS (�-3
Y
SEATTLE TACOMA www.bhcconsultants.com ��SS�orvautiNc��ti �ss�oNAL� �� J. KRESHEL, P.E. SICALETOCRDNGLY SHEET: 3 OF:
NO. REVISION BY DATE APPR APPROVED:
R. DORN, P.E.