Loading...
HomeMy WebLinkAboutS-0371209c\j LEGEND: ABBREVIATIONS SYMBOLS AND DESIGNATIONS T MO EXISTING PROPOSED AASHTO AMERICAN ASSOC. OF STATE MBMFR MANUFACTURER HIGHWAY MH MANHOLE RIGHT OF WAY BNSF PREMISES r _---------"'--"'— TRANSPORTATION OFFICIALS MIN MINIMUM TITLE N AB ANCHOR BOLT MON MONUMENT TITLE DETAIL NUMBER — CENTERLINE — GRAVITY SEWER AC ASPHALT CONCRETE MUTCD MANUAL ON UNIFORM TRAFFIC DETAIL / ACP ASPHALT CONCRETE PAVEMENT CONTROL DEVICES � -- PROPERTY LINE SANITARY SEWER MANHOLE OR STRUCTURE ADS POLYETHYLENE PIPE MW MONITORING WELL SCALE. 1/2" - 1'-0" C-2 EASEMENT //////�/��/, TO BE REMOVED OR ABANDONED ALD ALDER ��— DRAWING NUMBER WHERE DETAIL APPROX APPROXIMATE N NORTH IS REFERENCED. USE DASH IF CONTOUR ASPHALT CONCRETE PAVEMENT (ACP) - PLAN APWA AMERICAN PUBLIC WORKS NAD NORTH AMERICAN DATUM DETAIL APPEARS ON THE SAME ASSOCIATION NAVD NORTH AMERICAN VERTICAL DATUM SHEET AS SHEET REFERENCED. AVE AVENUE NE NORTHEAST Micp MONUMENT IN CASE PRE -CAST CONCRETE NIC NOT IN CONTRACT MON o BC BF BLIND FLANGE NO. NUMBER TITLE SECTION, ELEVATION OR SURFACE MONUMENT go O o O g CS BH BORE HOLE NTS NOT TO SCALE TITLE BLVD BOULEVARD NW NORTHWEST PROFILE REFERENCE LETTER PK NAIL BM BENCH MARK SECTION A REBAR &CAP BNSF BURLINGTON NORTHERN SANTA FE OC ON CENTER SCALE: 1/2" - 1'-0" OD OUTSIDE DIAMETER DASH IF SECTION IS TAKEN ON THE CB CATCH BASIN OH OVERHEAD SAME DRAWING. USE DRAWING SEWER MANHOLE CCW COUNTER CLOCK WISE OP OVERHEAD POWER NUMBER IF SECTION WAS TAKEN CDF CONTROLLED DENSITY FILL OPG OPENING ON A DIFFERENT SHEET. POWER POLE CF CLEARING LIMIT FENCE POWER POLE W/UNDERGROUND CONNECT CHLK CHAIN LINK P POWER SECTION LETTER CIPP CURED IN PLACE PIPE PE PLAIN END, PROFESSIONAL ENGINEER A - C/L, CL CENTERLINE PG PERFORMANCE GRADE GUY ANCHOR CLR CLEAR PSF POUNDS PER SQUARE FOOT C-1 CO CLEANOUT PSI POUNDS PER SQUARE INCH DRAWING NUMBER WHERE DETAIL CALLOUT POWER MANHOLE CONIC CONCRETE PVC POLYVINYL CHLORIDE SECTION IS DRAWN. USE DASH IF CPLG COUPLING PVMT PAVEMENT SECTION APPEARS ON SAME 4/C-1 TELEPHONE MANHOLE SHEET AS CUT. CSBC CRUSHED SURFACING BASE COURSE PWR POWER DRAWING # CSTC CRUSHED SURFACING TOP COURSE GAS VALVE RD ROAD ELEVATION LETTER DETAIL # WATER VALVE D/W DRIVEWAY REINF REINFORCEMENT A D DEPTH, DOUBLE REQ'D REQUIRED DBH DIAMETER BREAST HEIGHT RET RETAINING C-1 WATER METER DI DUCTILE IRON ROW, R/W RIGHT OF WAY DRAWING NUMBER WHERE ELEVATION IS DIA DIAMETER RRC RED REBAR AND CAP DRAWN. USE DASH IF ELEVATION WATER VAULT LID DIP DUCTILE IRON PIPE RT RIGHT APPEARS ON SAME SHEET AS DIPS DUCTILE IRON PIPE SIZE REFERENCED. FIRE HYDRANT DR DRIVE S SOUTH, SLOPE DTREE DECIDUOUS TREE SCH SCHEDULE BLOW -OFF DWG DRAWING SD STORM DRAIN BORE SITE (W/ FIELD DESCRIPTION) SDMH STORM DRAIN MANHOLE PIPING DESIGNATIONS E EAST, ELECTRICAL SDR STANDARD DIMENSION RATIO EA EACH SE SOUTHEAST MONITORING WELL EW EACH WAY SERV SERVICE EL, ELEV ELEVATION SF SILT FENCE PIPING IS IDENTIFIED BY ITS SIZE FOLLOWED BY PIPING SYSTEM AS FOLLOWS: GUARD POST EP EDGE OF PAVEMENT SSFM SANITARY SEWER FORCE MAIN DESIGNATES NEW PIPING: EX EXISTING SMH SEWER MANHOLE SIGN SS SANITARY SEWER FF FINSHED FLOOR SST STAINLESS STEEL 8" SS SHRUB FIG FINISH GRADE ST STREET PVC FT,' FEET STA STATION DECIDUOUS TREE, DIA (# OF TRUNKS) STD STANDARD DESIGNATES EXISTING PIPING: G GAS STL STEEL PAINTED POWER GALV GALVANIZED SW SOUTHWEST GRAY GRAVEL EX 8" CONC SS PAINTED TELEPHONE GV GATE VALVE T TELEPHONE T&B TOP AND BOTTOM PAINTED FIBER OPTIC HDPE HIGH DENSITY POLYETHYLENE TBM TEMPORARY BENCHMARK FOR NEW PIPING MATERIAL, FITTINGS, AND VALVES, SEE SPECIFICATIONS. A Q HMA HOT MIX ASPHALT TELJB TELEPHONE JUNCTION BOX GENERAL PIPING MATERIAL MAY BE NOTED. PAINTED TV HORIZ HORIZONTAL TELR TELEPHONE RISER HT HUB AND TACK TV TELEVISION (CABLE) PIPING SYSTEM DESIGNATIONS FOR EXISTING PIPING INDICATE TYPE OF PAINTED WATER HYD HYDRANT TVJB TELEVISION (CABLE) JUNCTION BOX SERVICE AND TYPE OF MATERIAL IF KNOWN. CONTRACTOR SHALL VERIFY ALL TVR TELEVISION (CABLE) RISER EXIST PIPE MATERIAL AND NOT RELY ON THIS DESIGNATION PRIOR TO PAINTED GAS ID INSIDE DIAMETER TYP TYPICAL CONSTRUCTION. IE INVERT ELEVATION SEWER IN, " INCH UGP UNDERGROUND POWER IPS IRON PIPE SIZE UNO UNLESS NOTED OTHERWISE FENCE JB JUNCTION BOX VCP VITRIFIED CLAY PIPE RAISED -BUTTON SOLID STRIPE VERT VERTICAL DRAWING REFERENCE L LENGTH RAISED -BUTTON SKIP STRIPE LF LINEAR FEET W/ WITH LN LANE W WATER, WEST G GENERAL EDGE OF PAVEMENT LT LEFT WL WATER LEVEL C CIVIL WM WATER METER CONCRETE MAX MAXIMUM WSDOT WASHINGTON STATE DEPARTMENT MB MAIL BOX OF TRANSPORTATION GRAVEL MDD MAXIMUM DRY DENSITY WS WATER SERVICE 0 I N m p I Q pcl- cn Call 48 Hours Q Z z Before You Dig J S-0371209 1-800-424-5555 UNDERGROUND SERVICE U DES War S . Uj P WA l F Wri DATE: pN BHC Consultants, LLC ���I�l_ �.�{) 4,��i1r_,�� SURVEYED: SCALE: 1601 Fifth Avenue, Suite 500 ��tiP , �� '(•T DESIGNED: N/G, HORIZONTAL: NAD 1963/1991 �- CITY O C �. !T' O _ VERTICAL AD 1 83/1 I CENTRAL RENTON SEWER INTERCEPTOR MAY 2015 RELINE & UPSIZE PROJECT FIELDBOOK: . Seattle, Washington 98101 l C t ' T. WHITEHOUSE, P.E. R E N TO N PAGE: t� _ 206.505.3400 �' DRAWN: L A P. SIMON DRAWING N0: w CONSULTANTS 49545 [L ONE INCH DATU M 206.505.3406 (fax) .po �o� R� �� o4 ISSUED FOR BID TJw 05/2015 ASK CHECKED: AT FULL SCALE Public works Dept. LEGEND, ABBREVIATIONS, SYMBOLS & DESIGNATIONS (�-3 Y SEATTLE TACOMA www.bhcconsultants.com ��SS�orvautiNc��ti �ss�oNAL� �� J. KRESHEL, P.E. SICALETOCRDNGLY SHEET: 3 OF: NO. REVISION BY DATE APPR APPROVED: R. DORN, P.E.