HomeMy WebLinkAboutzR-3818Set00 T 00 CY) i C) W I- rr W I- Z W U CD Z Z Q rr W O O a Vicinity Map NTS i 2 4 P NE 31, d Si `tea N dar River Park .._.i n m2.. r NFIoy f�T� ��Lnr 9 y NE th Lry NI: 7th Pf � s NE I Oth 5f y y NE%t St !E 31h -a Nc BIn ST a NF8% x w w NF'.t45t NE 7th PI m CHE 6th PI Site NF61h S: c NL 5Ih P x Fer�hP IEr�l;:r lPrh�ic•.I C.:II� dtti�St t1f ��3�dSt NE xr,d st c r3. Horizontal Control Diagram Datum Renton Technical College Site Information Building K Owner Sheet Index HORIZONTAL DATUM: NAD '83 '03, WASHINGTON COORDINATE SYSTEM NORTH SITE ADDRESS: 3000 NE FOURTH STREET RENTON TECHNICAL COLLEGE CHO COVER SHEET ZONE. BASED ON RTK GPS MEASUREMENTS CONSTRAINED TO THE WASHINGTON RENTON, WASHINGTON 98056 3000 NE FOURTH STREET CO.01 CIVIL NOTES STATE REFERENCE NETWORK. RENTON, WA 98056 CO.02 CIVIL NOTES BASIS OF BEARING: CENTERLINE KIRKLAND AVE. NE ZONING: IL C1.00 DEMOLITION PLAN C2.00 T.E.S.C. PLAN VERTICAL DATUM: NAVD 88 BASED ON RTK GPS MEASUREMENTS TAX ACCOUNT NOS.: 727800475 C2.10 T.E.S.C. DETAILS CONSTRAINED TO THE WASHINGTON STATE REFERENCE NETWORK AND GEOID Architect C3.00 GRADING AND STORM DRAINAGE PLAN 2003 MODEL. AREA: 4.48 ACRES C3.10 PAVING AND DRAINAGE DETAILS DISTURBED AREA: 0.8 ACRES C4.00 UTILITY PLAN ALL DISTANCES SHOWN ARE GROUND DISTANCES UNLESS OTHERWISE NOTED. McGRANAHAN ARCHITECTS C4.10 UTILITY DETAILS EXISTING IMPERVIOUS AREA PRIOR TO PROJECT 103,500 SQFT 2111 PACIFIC AVE, SUITE 100 C5.00 PAVING PLAN THE LOCATION AND DESCRIPTION OF ALL SURVEY MARKERS SHOWN HEREON PROPOSED IMPERVIOUS AREA AFTER PROJECT 104,900 SQFT TACOMA, WA 98402 C5.10 PAVING DETAILS ARE BASED ON FIELD OBSERVATIONS TAKEN ON DECEMBER 26, 2013, C5.20 PAVING DETAILS UNLESS OTHERWISE INDICATED. Scale: 1 "=80'-O" GG 4) CP# 28 460A-25.28 MIC er50'(� N=183052.33 E=1308175.05 ELEV.=341.67 / 0 1 80 160 IILi o0 F SCALE 1=80' O N 00 C-4 C14 0 z OVA I I CP# 22 460A-25.22 MIC N=182224.13 Jefferson Ave NE E=1308181.57 - - - - _�$ ELEV.=336.61 OF WA �� 0 �1 �.1� COUGHLIN PORTERLUNDEEN ti A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION PVC 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 <L43667 SEATTLE, WA 98104 F: 206/343-5691 Earthwork Quantities EXCAVATION 50 CY FILL 50 CY NOTE: THE QUANTITIES SHOWN ARE PRELIMINARY ESTIMATES ONLY AND INTENDED FOR MUNICIPAL PERMITTING AND REVIEW FEES. THE CONTRACTOR SHALL IGNORE THESE QUANTITIES, THEY ARE EXCLUDED FROM THE BID DOCUMENT INFORMATION. THESE VOLUMES SHALL NOT BE USED BY THE CONTRACTOR AS A BASIS FOR ANY CONTRACTUAL INFORMATION. THE CONTRACTOR SHALL PREPARE THEIR OWN EARTHWORK QUANTITIES BASED ON THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO DRAWINGS, SPECIFICATIONS, AND THE GEOTECHNICAL REPORT. List of Civil Abbreviations GENERAL ASP ASPHALT ATB ASPHALT TREATED BASE BM BENCHMARK B BOLLARD BC BOTTOM OF CURB BMP BEST MANAGEMENT PRACTICES BOE BOTTOM OF EXCAVATION BR BOTTOM OF ROCKERY BW BOTTOM OF WALL CHAN CHANNEL CB CATCH BASIN CO CLEAN OUT CONIC CONCRETE CD CURB DROP DI DUCTILE IRON DIA DIAMETER E EAST EL ELEVATION ELEV ELEVATION EX EXISTING EB EXPLORATORY BORING "If GENERAL FF FINISH FLOOR FDC FIRE DEPARTMENT CONNECTION FH FIRE HYDRANT GM GAS METER GV GAS VALVE HA HAND AUGER BORING IE INVERT ELEVATION IP IRON PIPE LF LINEAR FEET MH MANHOLE MAX MAXIMUM MJ MECHANICAL JOINT MIN MINIMUM N NORTH NIC NOT IN CONTRACT OD OUTSIDE DIAMETER OHP OVERHEAD POWER LINE (REC) PER RECORD REC PER RECORD RJ RESTRAINED JOINT RIM RIM ELEVATION REVISION GENERAL ROW RIGHT-OF-WAY S SOUTH SS SANITARY SEWER SD STORM DRAIN SOFT SQUARE FEET STD STANDARD TEMP TEMPORARY TIC TOP OF CURB TR TOP OF ROCKERY TW TOP OF WALL TYP TYPICAL W/ WITH W WEST W WATER WGT WEIGHT WM WATER METER WMH WATER MAN HOLE WV WATER VALVE YD YARD DRAIN SURVEYED: DESIGNED: KAW DRAWN: LBJ CHECKED: JAJ BY DATE APPR APPROVED: Civil Engineer COUGHLIN PORTER LUNDEEN 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 (206) 343-0460 CONTACT: KEN WIERSEMA Landscape Architect THE BERGER PARTNERSHIP 1721 8TH AVENUE N SEATTLE, WA 98109 (206)325-6877 CONTACT: JASON HENRY Contractor Survevor PACE 11255 KIRKLAND WAY #300 KIRKLAND, WA 98033 (425) 827-2014 CONTACT: BILL HAWKINS SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Construction Seauence 1. ARRANGE AND ATTEND PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. 2. VERIFY VERTICAL AND HORIZONTAL LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES. CONTACT ALL UTILITY COMPANIES THAT MAY BE AFFECTED BY THE PROPOSED CONSTRUCTION. CALL 1-800-424-5555. 3. FLAG CLEARING LIMITS AS INDICATED ON THE DRAWINGS. 4. PROVIDE CATCH BASIN PROTECTION. 5. INSTALL FILTER FABRIC AND BARRIER FENCE. 6. INSTALL TEMPORARY SEDIMENT TRAPS. (BAKER TANKS OR APPROVED EQUAL) 7. PERIODICALLY (DURING CONSTRUCTION) REMOVE EXCESS EXCAVATED MATERIALS, TRASH, DEBRIS AND WASTE MATERIALS AND DISPOSE IN AN AUTHORIZED LOCATION AT NO COST TO THE OWNER. MONITOR TESC EFFECTIVENESS. 8. REMOVE UNSUITABLE BEARING MATERIAL AS REQUIRED. 9. BEGIN SITE EARTHWORK. GRADE AND PLACE ACCEPTABLE FILL AS REQUIRED AND COMPACT SLAB SUBGRADE AS REQUIRED. 10. REMOVE ALL ESC FACILITIES ONLY WHEN THE ENTIRE SITE IS STABILIZED AND APPROVED BY THE CITY INSPECTOR. Hearing Examiner's Conditions of ADDroval 1. THE APPLICANT IS SUBJECT TO THE MITIGATION MEASURES AS DETERMINED BY THE ENVIRONMENTAL REVIEW COMMITTEE'S DECISION AUGUST 25, 2014. 2. THE APPLICANT SHALL BE REQUIRED TO PROVIDE A LIGHTING PLAN THAT ADEQUATELY PROVIDES FOR PUBLIC SAFETY WITHOUT CASTING EXCESSIVE GLARE ON ADJACENT PROPERTIES AT THE TIME OF BUILDING PERMIT REVIEW. DOWN -LIGHTING SHALL BE USED IN ALL CASES TO ASSURE SAFE VEHICULAR MOVEMENT IN AN AREA WHERE PEDESTRIANS COULD BE WALKING. THE LIGHTING PLAN SHALL BE SUBMITTED TO, AND APPROVED BY, THE CURRENT PLANNING PROJECT MANAGER PRIOR TO BUILDING PERMIT APPROVAL. 3. THE APPLICANT SHALL PROVIDE A BICYCLE AND VEHICLE PARKING STALL ANALYSIS BASED ON THE CRITERIA USED FOR QUANTIFYING THE NUMBER OF VEHICLE AND PARKING SPACES REQUIRED IN THE CITY CODE, AND PROVIDE AN UPDATED PARKING PLAN THAT SHOWS THE NUMBER OF BICYCLE PARKING SPACES REQUIRED AND VEHICLE PARKING STALLS, THAT WILL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER, PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 4. THE APPLICANT SHALL PROVIDE A LOT COVERAGE ANALYSIS FOR THE OVERALL TECHNICAL COLLEGE CAMPUS. 5. THE APPLICANT SHALL PROVIDE PLAN SETS SHOWING ANY ROOFTOP EQUIPMENT OR STRUCTURES THAT MAY REQUIRE SCREENING PER CITY CODE, WHERE THE SUBMITTED ELEVATIONS DO NOT SHOW ROOFTOP EQUIPMENT, AND SUCH EQUIPMENT SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER, FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION PERMIT ISSUANCE. Environmental Review Committee Mitigation Measures August 25, 2014 1. PROJECT CONSTRUCTION SHALL BE REQUIRED TO COMPLY WITH THE RECOMMENDATIONS OUTLINED IN THE SUBMITTED GEOTECHNICAL ENGINEERING REPORT FOR RENTON TECHNICAL COLLEGE PROPOSED BUILDING K3 IMPROVEMENTS, PREPARED BY GEOENGINEERS, INC, DATED JULY 17, 2014 (EXHIBIT 3). 2. PROJECT TESC (TEMPORARY EROSION AND SEDIMENT CONTROL) PLAN SHALL BE REQUIRED TO COMPLY WITH THE RECOMMENDATIONS OUTLINED IN THE TECHNICAL INFORMATION REPORT, PREPARED BY COUGHLIN PORTER LUNDEEN, DATED JULY 2, 2014 (EXHIBIT 5). 3. PROJECT CONSTRUCTION SHALL BE REQUIRED TO COMPLY WITH THE OUTLINED RECOMMENDATIONS IN THE SUBMITTED LIMITED HAZARDOUS MATERIALS SURVEY REPORT FOR AUTOMOTIVE TRADES COMPLEX AT RENTON TECHNICAL COLLEGE, PREPARED BY PBS ENGINEERING AND ENVIRONMENTAL, DATED MARCH 31, 2014 (EXHIBIT 4). UPERMIT# U15000494 VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. Approved By: Date: Approved By: Date: Approved By: Date: Approved By: Date: AUTOMOTIVE TRAINING CENTER 04/30/2015 RENTON TECHNICAL COLLEGE FIELDBOOK: PAGE: RENTON WASHINGTON DRAWING NO: CIVIL COVER SHEET C0.00 SHEET: OF: 1 13 R-381801 Demolition Notes Erosion Control Notes Surface Water Standard Plan Notes 1. EXISTING UTILITIES AND UNDERGROUND STRUCTURES SHOWN ON THE PLAN ARE BASED UPON THE BEST AVAILABLE PUBLIC RECORDS AND/OR PRIVATE RECORDS AS SUPPLIED BY THE PROJECT OWNER AND/OR DATA OBTAINED VERBALLY FROM OWNERS OR OFFICIALS ASSOCIATED WITH THE PARTICULAR UTILITY. NEITHER THE OWNER NOR THE ENGINEER GUARANTEE ACCURACY OR COMPLETENESS OF THIS INFORMATION AND ASSUME NO RESPONSIBILITY FOR IMPROPER LOCATIONS ON THE CONSTRUCTION PLANS. OTHER UNDERGROUND FACILITIES NOT SHOWN ON THE DRAWINGS MAY BE ENCOUNTERED DURING THE COURSE OF THE WORK. ALL INVERT ELEVATIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 2. IF CHANGED CONDITIONS ARE ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PROMPTLY OF (1) PREEXISTING SUBSURFACE CONDITIONS DIFFERING FROM THOSE INDICATED IN THE PLANS, OR (2) PREEXISTING UNKNOWN SUBSURFACE CONDITIONS, OR AN UNUSUAL NATURE, DIFFERING MATERIALLY FROM THOSE ORIGINALLY ENCOUNTERED AND GENERALLY RECOGNIZED AS INHERENT IN WORK OF THE CHARACTER PROVIDED FOR IN THE CONTRACT. THE CONTRACTOR AND OR OWNER SHALL MAKE NO CLAIMS TO THE ENGINEER FOR RECOMPENSATION FOR EXTRA WORK RESULTING FROM CHANGED CONDITIONS UNLESS THE ENGINEER HAS APPROVED THE WORK IN WRITING. 3. CONTRACTOR SHALL CALL THE UTILITIES UNDERGROUND LOCATION CENTER FOR FIELD LOCATION OF ALL UTILITIES It AND SHALL NOT BEGIN EXCAVATION UNTIL ALL KNOWN UNDERGROUND FACILITIES IN THE VICINITY OF THE LLI PROPOSED WORK HAVE BEEN LOCATED AND MARKED. IF THE UTILITY IS NOT A SUBSCRIBER OF THE UNDERGROUND LOCATION CENTER THEN THE CONTRACTOR SHALL GIVE NOTICE TO THAT UTILITY. z LU 4. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF ALL UTILITY PURVEYOR, AND CITY OR STATE RECORDS U RELATIVE TO THE EXISTING UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR AVOIDING DAMAGE TO THESE FACILITIES AND SHALL RESTORE ALL UTILITIES AT CONTRACTOR'S OWN EXPENSE. 0 z_ 5. VERIFY THAT ALL UTILITY SERVICES TO BE DEMOLISHED HAVE BEEN DISCONNECTED. z 6. ERECT BARRIERS, SHORING AND THE LIKE TO PROTECT PERSONNEL, CONSTRUCTION AND VEGETATION TO REMAIN. COMPLY WITH ALL STATE AND LOCAL AGENCY REQUIREMENTS. Q 7. DO NOT SHUT OFF OR CAP UTILITIES WITHOUT PRIOR NOTICE. COORDINATE WORK WITH OWNER AND LOCAL UTILITY PURVEYORS. W 8. MAINTAIN VEHICULAR AND PEDESTRIAN TRAFFIC ROUTES: ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, i SIDEWALKS, AND ADJACENT FACILITIES; DO NOT CLOSE OR OBSTRUCT STREETS, SIDEWALKS, OR PASSAGEWAYS ~ WITHOUT PERMISSION FROM AUTHORITIES HAVING JURISDICTION; MAINTAIN FIRE ACCESS ALONG ACCESS ROAD AT O ALL TIMES; MEET ALL APPLICABLE CODES AND ORDINANCES. 75 9. PROTECT FROM HARM ANY TREES, OR OTHER OBJECTS SELECTED TO REMAIN. O 10. DO NOT DAMAGE EXISTING CONSTRUCTION TO REMAIN. 11. RESTORE ANY IMPROVEMENTS DAMAGED BY THIS WORK TO THEIR ORIGINAL CONDITION, AS ACCEPTABLE TO Q OWNER. REPAIR ANY DAMAGE TO ADJACENT STRUCTURES, UTILITIES, SITE, AND WORK OF THIS CONTRACT TO REMAIN AT NO ADDITIONAL COST TO OWNER. 12. NO BLASTING ON SITE. DO NOT USE EXPLOSIVES. 13. SPRINKLE DEBRIS AS NECESSARY TO LIMIT DUST TO LOWEST PRACTICABLE LEVEL. DO NOT SPRINKLE TO EXTENT CAUSING FLOODING, CONTAMINATED RUNOFF OR ICING. 14. REMOVE EXISTING ABOVE -GRADE AND BELOW -GRADE IMPROVEMENTS AS INDICATED AND AS NECESSARY TO FACILITATE NEW CONSTRUCTION. CARE SHALL BE TAKEN THAT DAMAGE DOES NOT OCCUR TO EXISTING PAVEMENT WHICH IS TO REMAIN IN PLACE AND THAT ALL PAVEMENT REMOVALS ARE ACCOMPLISHED BY MAKING A NEAT VERTICAL SAW CUT AT THE BOUNDARIES OF THE AREA TO BE REMOVED. 15. REMOVE TREES, GROWTH AND UNDERBRUSH AS REQUIRED FOR NEW CONSTRUCTION AND AS INDICATED. REMOVAL OPERATIONS SHALL BE PERFORMED IN A MANNER TO PROTECT PROPERTY. 16. MAKE CUTS AT CLOSEST PAVING JOINT. 17. THE CONTRACTOR WILL BE RESPONSIBLE FOR FURNISHING, SETTING AND MARKING ALL LINE AND LOCATION STAKES, INCLUDING OFFSETS AND GENERAL CONSTRUCTION STAKING. WHEN WORK REQUIRING BE ON SITE. A QUALIFIED LAYOUT ENGINEER, SURVEYOR, OR TECHNICAL SPECIALIST MUST BE ASSIGNED TO THE CONTRACTOR'S CREW CONTROL IS BEING PERFORMED, ALL NECESSARY RELATED EQUIPMENT, SUPPLIES AND INSTRUMENTS SHALL FOR THIS WORK. THIS EQUIPMENT AND PERSONNEL MUST BE AVAILABLE, AT NO ADDITIONAL COST TO OWNER FOR THE PURPOSE OF VERIFYING LAYOUT AND CERTIFYING THE ACCURACY OF WORK ON THE SITE. 18. PROVIDE FOR THE PROTECTION OF PERSONS PASSING AROUND OR THROUGH THE AREA OF DEMOLITION. 19. TRAFFIC: DO NOT OBSTRUCT WALKS OR PUBLIC WAYS WITHOUT THE WRITTEN PERMISSION OF GOVERNING AUTHORITIES AND OF THE OWNER. WHERE ROUTES ARE PERMITTED TO BE CLOSED, PROVIDE ALTERNATE ROUTES IF REQUIRED. 20. THE CONTRACTOR IS RESPONSIBLE FOR PRESERVING ALL BENCHMARKS AND STAKES AND THE REPLACEMENT OF ANY THAT ARE DISPLACED OR MISSING 21. THE REFUSE RESULTING FROM CLEARING AND GRUBBING SHALL BE DISPOSED OF BY THE CONTRACTOR IN A MANNER CONSISTENT WITH ALL GOVERNMENT REGULATIONS. IN NO CASE SHALL REFUSE MATERIAL BE LEFT ON THE PROJECT SITE, SHOVED ONTO ABUTTING PRIVATE PROPERTIES, OR BE BURIED IN EMBANKMENTS OR TRENCHES ON THE PROJECT SITE. DEBRIS SHALL NOT BE DEPOSITED IN ANY STREAM OR BODY OF WATER, WETLAND, OR IN ANY STREET OR ALLEY, OR UPON ANY PRIVATE PROPERTY EXCEPT BY WRITTEN CONSENT OF THE PRIVATE PROPERTY OWNER. MAINTAIN HAULING ROUTES CLEAN AND FREE OF ANY DEBRIS RESULTING FROM DEMOLITION WORK ON THIS PROJECT. A• Jq of was��Cp COUGHLIN PORTERLUNDEEN A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 1 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 43667 SEATTLE, WA 98104 F: 206/343-5691 GISTFR CSC 'oNAL E� /d 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON, PUBLIC WORKS DESIGN ENGINEER. 2. THE BOUNDARIES OF THE CLEARING LIMITS AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY FLAGGED BY SURVEY TAPE OR FENCING IN THE FIELD PRIOR TO CONSTRUCTION IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND OBSERVED DURING CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 3. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. 4. ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITEE. 5. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE PERMITEE SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 6. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR RETENTION FACILITIES. 7. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH MARCH 30TH) OR SEVEN DAYS DURING THE DRY SEASON (APRIL 1ST THROUGH SEPTEMBER 30) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.). 8. WET SEASON SEASONAL EROSION AND SEDIMENT CONTROL REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES CLEARING BETWEEN OCTOBER 1 AND MARCH 30 INCLUSIVE, UNLESS OTHERWISE APPROVED BY THE CITY THROUGH AN ADJUSTMENT PROCESS. 9. COVER MEASURES WILL BE APPLIED IN CONFORMANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL. 10. ANY AREA NEEDING ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 11. THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. 12. AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 13. DURING THE TIME PERIOD OF OCTOBER 1ST THROUGH MARCH 30TH, ALL PROJECT DISTRIBUTED SOIL AREAS GREATER, THAT ARE TO BE LEFT UN -WORKED FOR MORE THAN 12 HOURS, SHALL BE COVERED BY MULCH, SODDING OR PLASTIC COVERING. 14. ANY PERMANENT RETENTION/DETENTION FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE PERMANENT FACILITY IS TO FUNCTION ULTIMATELY AS AN INFILTRATION SYSTEM, THE TEMPORARY FACILITY MUST BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY. 15. PRIOR TO THE BEGINNING OF THE WET SEASON (OCT. 1), ALL DISTURBED AREAS SHALL BE REVIEWED TO IDENTIFY WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. A SKETCH MAP OF THOSE AREAS TO BE SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY OF RENTON FOR REVIEW. NO. I REVISION 1. THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY. 2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE CONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF RENTON PLAN REVIEW SECTION AND THE APPLICANT. 3. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE (RMC), THE LATEST EDITION OF THE STANDARD SPECIFICATION FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THESE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY CONSTRUCTION (E.G. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICAL. ETC.). THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN WITH THE CITY. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. GRADING ACTIVITIES (SITE ALTERATION) ARE LIMITED TO THE HOURS OF 7 A.M. TO 7 P.M. MONDAY THROUGH SATURDAY AND NO WORK ON SUNDAY IS ALLOWED, UNLESS OTHERWISE APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON. 7. IT SHALL BE THE APPLICANT'S/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE INITIATING OFF -SITE WORK. EASEMENTS REQUIRE CITY REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 8. FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS OF CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF RENTON. 9. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 10. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES MUST BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 11. ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95 PERCENT DENSITY, STANDARD PROCTOR. 12. OPEN CUTTING OF EXISTING ROADWAYS FOR NON -FRANCHISED UTILITY OR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY OF RENTON TRENCH RESTORATION STANDARDS. 13. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 14. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. 16. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 17. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE SOLID LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS. 18. BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES. 19. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 20. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING SURVEYED: DESIGNED: KAW DRAWN: LBJ CHECKED: JAJ BY I DATE I AP P R APPROVED: SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M 21. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 22. DRAINAGE OUTLETS (STUB -OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR THOSE LOTS APPROVED FOR INFILTRATION BY THE CITY. STUB -OUTS SHALL CONFORM TO THE FOLLOWING: x A. EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE DRAINS NECESSARY TO RENDER THE LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE FREE FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORMWATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE -FOOT -HIGH, 2" X 4" STAKE MARKED "STORM" OR "DRAIN" THE STUB -OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND BE SECURED TO THE STAKE. C. PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL AND, IF NON METALLIC, THE PIPE SHALL BE PLACED IN A TRENCH WITH A TRACING WIRE ABOVE OR OTHER ACCEPTABLE DETECTION. D. PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. E. THE APPLICANT/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB -OUT CONVEYANCE LINES WITH RESPECT TO OTHER UTILITIES (E.G. POWER, GAS, TELEPHONE, TELEVISION). F. ALL INDIVIDUAL STUB -OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOME OWNER. G. STORM DRAINAGE PIPE SYSTEMS SHALL NOT PENETRATE BUILDING FOUNDATIONS, EXCEPT FOR SUMP PUMP DISCHARGE LINES USED TO RAIN CRAWL SPACES, PROVIDED THE SUMP PUMP SYSTEM INCLUDES BACKFLOW PREVENTION OR A CHECK VALVE. 23. ALL DISTRIBUTED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE MUST DEMONSTRATE ONE OF THE FOLLOWING: THE EXISTING DUFF LAYER SHALL BE STAGED AND REDISTRIBUTED TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL, OR; AMENDED SOIL SHALL BE ADDED TO MAINTAIN THE MOISTURE CAPACITY. 24. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. CITY OF m_11N RENTON Planning/Building/Public Works Dept. Approved By: Approved By: Approved By: Approved By: UPERMIT# U15000494 Date: Date: Date: Date: AUTOMOTIVE TRAINING CENTER 04/30/2015 RENTON TECHNICAL COLLEGE FIELDBOOK: PAGE: RENTON WASHINGTON DRAWING N0: C0.01 CIVIL NOTES SHEET: 2 OF: 13 R-381802 Sanitary Sewer Notes And Specifications 1. ALL WORK AND WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATION OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF It RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 W HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. z 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR W THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. U 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED Or PERMITS PRIOR TO ANY CONSTRUCTION. z 7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL z OTHER PLANS. Q 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. IIr 9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED W PROFESSIONAL SURVEYOR. 10. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH 0 OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR 75 TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED 0 ~ 11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY MIX PATCH MUST BE PLACED IMMEDIATELY AFTER Q BACKFILL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT STANDARDS. 12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7 OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. A• Jq of was��Cp COUGHLIN PORTERLUNDEEN A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 1 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 43667 SEATTLE, WA 98104 F: 206/343-5691 GISTFR CSC 'oNAL E� /d Water Plan General Notes 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153 A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS ,AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINTS) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 8. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND 0-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. " REVISION 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. 17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7- 11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 20. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 21. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 22. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. * 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS. SURVEYED: DESIGNED: KAW DRAWN: LBJ CHECKED: JAJ BY I DATE I AP P R APPROVED: SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M General Paving Notes 1. A COPY OF THE APPROVED PLANS SHALL BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY OTHER REQUIRED OR RELATED PERMIT PRIOR TO BEGINNING CONSTUCTION. 2. ALL LOCATIONS OF EXISTING UTILITIES HAVE BEEN ESTABLISHED BY FIELD SURVEY AND AVAILABLE RECORDS AND SHOULD THEREFORE, BE CONSIDERED ONLY APPROXIMATE AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS AND TO DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. 3. ALL ASPHALT CONCRETE WORK IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO THE CITY OF RENTON STANDARDS AND SPECIFICATIONS. 4. ALL ASPHALT CONCRETE WORK ON THE PROJECT SITE SHALL CONFORM TO THE "2012 WASHINGTON STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION". 5. ALL ASPHALT CONCRETE PAVEMENT SHALL BE PLACED IN ACCORDANCE WITH WSDOT/APWA SECTION 5-04 UNLESS OTHERWISE SPECIFICALLY NOTED. 6. PROOF ROLL AND REMOVE ANY SOFT SPOTS. REPLACE REMOVED MATERIAL WITH STRUCTURAL FILL PER THE GEOTECHNICAL ENGINEER. CONTRACTOR SHALL TEST AND VERIFY SUBGRADE MEETS COMPACTION REQUIREMENTS PRIOR TO PAVING. 7. STERILIZE ALL AREAS TO BE PAVED WITH A SOIL STERILANT, PRAMITOL 25E OR EQUAL, AS RECOMMENDED BY THE MANUFACTURER. 8. AGGREGATE SHALL BE TYPE CLASS B, 1/2 INCH MAXIMUM MEDIUM GRADING, CONFORMING TO SECTION 9-3.8 OF THE WSDOT-APWA. ASPHALT BINDER SHALL BE PAVING ASPHALT, GRADE AR-4000, AND SHALL COMPLY WITH SECTION 9-02.1 OF WSDOT-APWA. ASPHALT CONCRETE MIXING AND PROPORTIONING SHALL COMPLY WITH SECTION 9-03.8 OF THE WSDOT-APWA. 10. CRUSHED SURFACING SHALL BE PLACE IN ACCORDANCE WITH WSDOT- APWA SECTION 4-04 AND SHALL MEET THE REQUIREMENTS OF WSDOT-APWA 9-03.9(3). 11. CONTRACTOR SHALL PREPARE THE EXISTING ASPHALT PAVEMENT SURFACE TO BE OVERLAID IN ACCORDANCE WITH 5-04.3(5)A. 12. SAWCUT EXISTING ASPHALT FULL DEPTH WHERE NEW PAVEMENT ABUTS EXISTING. 13. APPLY TACK COAT TO ALL EXISTING PAVEMENT SURFACES TO BE OVERLAID OR ABUTTED WITH NEW ASPHALT PAVEMENT. TACK COAT SHALL NOT BE APPLIED IN TEMPERATURES BELOW 50 DEGREES F. 14. CONTRACTOR SHALL PROTECT FROM DAMAGE ALL EXISTING FEATURES TO REMAIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR REPAIRING OR REPLACING TO THE OWNER'S SATISFACTION ANY AREA THAT DEFACEMENT OR DAMAGE HAS OCCURRED AT NO COST TO THE OWNER. CITY OF m-11N RENTON Planning/Building/Public Works Dept. Approved By: Approved By: Approved By: Approved By: UPERMIT# U15000494 Date: Date: Date: Date: AUTOMOTIVE TRAINING CENTER 04/30/2015 RENTON TECHNICAL COLLEGE FIELDBOOK: PAGE: RENTON WASHINGTON DRAWING N0: C0.02 CIVIL NOTES SHEET: 3 OF: 13 R-381803 MONITOR OF SOILS. OF EX POWER N AVING EX VAULT TREE W/PROTECTION .,CKFILL WITH CLEAN COMM SERVICES REMOVE I l CONTOUR (INDEX) MA IVA ♦REMCVE EX SITE STORM SYSTEM IF♦♦♦CONTOUR SALVAGE EX All 914- CONCRETE R �'M.j 11 — 1% WATER LINE SIGN To OWNER REMOVE END OF TRENCH-N--'.4 DRAIN, COORD W1 NEW IAN Fall pe" , ON 01115"1 STORM DRAINAGE LINE SD,' PAVING. RE -CONNECT TO W, f CONCRETEEMOVE • 1 • 1 ►iti1►1 - - - - - - _--♦♦ii► #!E'i.�►!! �!+1►'.*�1►'�►wi►!�1►�! : r.'I'I �,�' ii y �- ; '� ♦ ♦'�` i♦ !i► ► ,. �, - • ♦�;♦ # ♦�t ►► ♦ ► ♦♦♦SANITARY SEWER LINE SS ` s♦.� �r ♦ ♦wit,► a '',1►1#*► ♦♦ POWER E r TELEPHONE LINE EX ASPHALT PAVING PROPOSED BUILDING 1110" MANOR OUTLINE SHOWN GAS LI N E GAS,' FOR REFERENCE WATER METER/VALVE/FH STORM CB/MH COORDINATE DEMO 1 , A.r►_r �.�.��►�_►A'i� I 1 11 , al ;� ♦ '�SANITARY SEWERWALKS AND CURB WITH LL_ SEQUENCING GAS VALVE/METER WQ VAULTS (TYP) STREET LIGHT ASSEMBLY r 1 aw �► VE IVA COORDINATE W/ IN PIP TION ASPHALT FOR GAS ENTRY IONIAiAT BUILDINGS TO REMAIN EX SITE WATER (FIRE & DOMESTIC) SERVICES ALSO PROVIDE WATER TO BUILDING L. COORDINATE SHUT DOWNS OF WATER SERVICES WITH ALL CAMPUS USERS. CHANGES TO WATER SYSTEM TO BE COORDINATED WITH CLASS SCHEDULES AND OCCUR DURING SUMMER BREAKS. SYSTEMS SHALL BE FUNCTIONAL WHEN CLASSES ARE IN SESSION. " to I RULILU UMU l — — _ \ 1 REMOVE / ABANDON EX REMOVE EX SAWCUT AND REMOVE err — SAWCUT AND REMOVE SEE DEMOLITION NOTES ON CO.01 I I\ OMOVDAL/ABANDON SANITARY SEWER. SEE j RE2 C4.00 FOR REPLACEMENT I CONCRETE EX CURB AND WALK ,` EX ASPHALT PAVING AND SEQUENCING NOTES ON G I.01 I I Imo' �3 I COORDINATE WITH USE REMOVE NORTH _ SAWCUT AND REMOVE OF EX GAS W/ PSE o' t I OF K2 BUILDING END OF EX �a i CURB AND WALK REMOVE EX OIL TANK REMOVE ExA" COORDINATE POWER AND COMMUNICATIONS DEMO f TRENCH DRAIN f j I WITH ELECTRICAL AND COMM DESIGN REMOVE EX BIKE RACK ' SEE HAZARDOUS MATERIALS COORDINATE W FDCS &PINS f , (,� REMOVE EX WATER VAULT REMOVE EX ASPHALT ; I REMOVE EX SKY BRIDGE / COORDINATE SALVAGE OR rnnan W� Aoru'I e SPECS FOR DISPOSAL AND ,,,,,,r� ,., , ,, NEW PAVING _.__ _ _ / f , r rl AND RACK FI nW VAI VF -_ REMOVAL WITH OTHEN 51iE PLANS r''. LANDING BEHIND CURB RAMP PROTECT EX REE ;�'� �f .� �5� UPERMIT# UI5000494 j ,, 3 ! 4. r.+.•,�" `, t �!' L 11���■. l Ir■ ■■■� ■lam mMlw� awwar 1? irl■I� �w �{� r■� � ? r �■ ■.■r `- — 1.11Y1Fi (,j Approved ,MIT.►, LT �,.�., ,. ,... rr ..,• By SALVAGE EX SIGN I «; 1 �. PROTECT Date: FOR RE -INSTALLATION i LIMITS OF WORK �6 EX SIGNS r ' yam. roved �- y PPBy: A Date: t r' _ Approved Date i. , e CONSTRUCTION RECORD DRAWING O A, Jq� - _ -- Approved BY: Date: This construction record drawingIs a co �� WASH SURVEYED: SCALE: copy of a cad file prepared by �� r� vERr�rx wvo lase DESIGNED: AS NOTED HDRIZONUL: ""° ,a�,i,se, :; ,.� CITY OF AUTOMOTIVE TRAINING CENTER COUGHLIN PORTER LUNDEEN and has been edited to reflect field �Q �' rf. COUGHLINPORTERLUNDEEN verified invert and rim elevations of the storm, sanitary sewer and water w I<Aw RENTON TECHNICAL COLLEGE main systems. Field verified invert and rim elevations were obtained by "'� DRAWN: � RENTON CE&C CONSTRUCTION IN MARCH OF 2017 ACONSULTINGSTRUCTURALANDCIVILENGINEERING CORPORATION Li RENTON WASHINGTON ONE INCH DATU M The on -site private storm drainage facilities and public roadway ,F 43667 ,� c�,� '� 801 SECOND AVENUE -SUITE 900 P: 206/343-0460 CHECKED: F'C tt}I SEATTLE, WA 98104 F: 206/343-5691 d,qd AT FULL Sc�E Planning/Building/Public Works Deat. improvements were installed in accordance with the approved plans and �,ss rs t �- aC+� I (j`� IF NOT ONE INCH the documented field revisions and function as intended. f�VAL E' NO. REVISION BY DATE APPR APPROVED: s ACCORDINGLY DEMOLITION PLAN 04/30/2015 FIELDOOOK. PAGE: DRAWING NO: C 1.00 SHEET: OF: 4 13 SOW SSMH R11V-338.84 0. F. = , �. SDMH RIM-340.08 CL CHAN 8'CONC(N,S)=327.69 /E 18'cw"_ G.F -337 /8 KIR KLA ND A VENUE N. E CL CHAN 8'nNC(S)=330.78 lE 18'CMP(E)=332.98 LIMITS OF WORK ce RIM-340.04 o CB R/M=33782 ZZ F-7 CONC WALK ---- ---- y CONCWWK --- W W W W W W W (WIVC WAI L W W _ W M _ — — —12S— — v ---- — — ASPHALr `� 1---0 1_ =TAP T4'naAPL�--�_4°-------1A4 —� ----------------�4'tIAPL�--- J— --- — - — / DRIAEWar — — - _ — -- --- — — -SD � ---- — -----s - , —f�_ n---- 14:A4APCrLE _ �sD — --—�" ---s� -- SD------°D ---- S� --S — -- �— — --_ ---_-- A �� as l - WnTr---- — -- — _�--- — — — --- — _ ASPHALT Is - - -_ \ - �� ` DRIVEWA1K / l n �Iwn 4vin wn n " �Iw n �Iwn �Iwn �I �Iw 20 3ES>_� 1 CHAIN ) X \ � (� � — �— X 2 s I �T' 6 cHA/NUNK -20 4� I (/ — — — — — — — —� s PROVIDE INLET PROTECTION IF- -------------------�`—V Iu s2 SD �' DRIVE IS USED FORME ACCESS I L�wn I 1 > 0 4-/'X'; DWN — _ — _ — — OVER" _� _ - \ I I— i fL �� W ( IP — I A� ��_ \� UMR DMH RIM=342.83 �I I CB RiM=���.u9� 1 I PROTECT EX I > — _ ,r E 8 PVc(E)=33373TREES (TYP)IE 8'PVCE37rc I /c /8 IE — —V PRO ECT EXZ ISZPS332.E BUILDING TO REMAINLU IE 18CVP(W)=33206 THE (TYP) U > SEE ARCH'L FOR �� ��o \ ° I RENOVATION SCOPE I CLEAR AND GRUB k z CB R/V-338.77 FOR NEW ADDITION I E a'PI PROTECT STORM -I Z OILIHr20 A I I INLETS (TYP) �l Q sEPARA TOR - I I I I GD GD G D R 00 D GD G D D RD tD OVERHANG RD D D D RD w I 1 o=a=c0 o==ten= _�n=a=��n=a��MAINTAIN EX P VEMENTN 1101117:77# Gas uNE IP I IP' I AS WORKING S 'FACE�'FEENCECONSTRUCTION / WQ VAULr� c0 AND FOR SITE CCESSS WS S SSl0'D s�s SD I REMOVE ONLY WHEN O / I NEEDED FOR NEW WORK 75 — IE 8'PVC(N)-5J4.8.7 AND FINAL PAVt G (TYP) / - ------ _ / I + /, CLEAR AND GRUB J \ RD e WO V U .\\\\\ — — — — — \ \` ` I FOR NEW ADDITION n o❑❑ — CONS�� \ I — — d FENCE + + + Q I \ \ /• + PROTECT EX TRENCH DRAINSV ''� � i — — \ + + + FROM SILTY WATER TYP j I ( ) + <\\\ \\\\\��C + / / 111 I I G1 I \ + + � II I L \ + CONSTRUCTION \ L — G I I + CLEAR AND GRUB GATE, I \ I I I I + + FOR NEW BUILDING + I o N PROTECT STORM 1 +I� �I \ I I I I I I_ I � I I CONc sLa II' INLETS (TYP) I + I + \ + + + + + + — , 1 hI' WITH cEN IAroR � � �,�� I � � '�I ' I BUILDING TO REMAIN � / I \ I i + I II / s SEE ARCH'L FOR I / / � �— + ( I o I + 1 I 1 % N II I ► RENOVATION SCOPE I \ \ + + \ , \ ) l \ I t III \ + + + + \ \\ I \ \ + + EXPOSED I S \ + + + I I II #1 I+ _ 4'PVC(E�=335.47 — I \ RlM=3 8.57 8'PVc(S,W)=335.021 c0 III Jill III I IIII \ /,, ASPHALT DR/Vf WO VAUL �n� �� P �SPHaLrORtiE l — — IIIIIII/ - 6'PVC 334.5❑n❑ \ / \ � IIIIIIIII — � I\LIT\ � II I _ I I _ / I_ _j / \ SPEED 7?IlMfi IIIIIIIIIf' I _ _ fir- l l PROTECT STORM IIM L I IIIL-.:� I I (TYP ) 1 Ill lllho�� 11► I I I IP I ( ) I I I I � BUILDING TO REMAIN %'ENCED CONSTRUCTION \ \I I CB R1M I 339�;_- IIIIII I II I / SEE ARCH'L FOR / / / bIIF�E�RENT SCOP 5`OF WORK p IIII � joiil / PROTECT EX TRENCH DRAINS RENOVATION SCOPE FROM SILTY WATER TYP COVER DISTURBED BARE SOILS �F FENCEST�S Q�tATE WORT / / _II i (TYP) AFTER REMOVAL OF OVERHEAD \ / / / ETWTY. COORDINATE FENC WALK. PROVIDE TEMPORARY COVER _ �� s / LOSURES WITFf OTIHER CAMPI 11 I I\ OR PERMANENT RESTORATION AS _ �/ — �\ F RENTON FIRE DERARTMENT ----- —� --- — — _ _---------------- �/ '/ / �— ill — ----- ---- — — — ---- — ---- — — — _ — — — — —-------�a� — — — — ------------ems--- SEE TESC NOTES ON CO =36— --- --_ � / L.il`LHNl1R — — I I I— — — — — — — — — — — — — — — — — — — — — — — — — — — (LT' — — — — — -- — — _ — — -- — — — — — — — — — — — — —'- — — — — — — — — — — — — — — — — — - — — — — — _ �►`�--------------- --- ---- -_------------------ - I \ 350-- l 358-- — ----- ----- --- II 'S2.c' I ------------------------------------------ —_------350----------- ---- — —----------------350— _ __ _ _ ____ —— — — — — — — — — — — — 3 2g0IECLEIATfOIT_ _ — _ _— zB�i�3—sg3�— -- __ — -- -- _— ----- ---_ —_ _ _ — --- / — _ — — lE� 2vcC *) L.3e56. � _ / t _ _ _ _ _ _ _ _ _ _ _ _ _ _ � ------------------------ ------------a5�----s�uej6�o— —_--�— _ ----- \�`� \�� \ PROTECT EX a _ _ _ _ _ _ — _ — — — PROTECT EX Ass \ TREES (TYP) l\� TREES TYP l �.-_-fig � nniL, 1, i wrv� v✓nLK / l — IJ� '�1►� -) coNc wA)K I I / i I I I foNc WALK \� \ J Sb� v�� UM U R T -uMrr uMlr uMIT ° JUMR T uMIT /l o Approved By: lE 6'PVC(NE)-N9.82 �� ASPHALT DRIVE IE 8'PVC(SE)=349 / Approved B t - / LIMITS OF WORK �� °D \ IE 8'PVC(S)-349.52 / j p p y: w / w IE 12'PVC(NW)=34702 / w w \ w w w w � w vv — \ \ \ 1 ' e''R — �'_\ ` __\ _ __\__ Approved By: -- ��___ _ 6CURBSTOPS — —� I —BSc°'-- --- 356 ��--_=--------------f?\ 3� — �, 'I \LJ, - --- _— T_---- Approved By. 43667 O 'ISTFR� Cs� INAL COUGHLIN PORTERLUNDEEN A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 SEATTLE, WA 98104 F: 206/343-5691 " REVISION SURVEYED: DESIGNED: KAW DRAWN: LBJ CHECKED: JAJ BY DATE AP P R APPROVED: SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. Call before• j •. • or :�� . UNDERGROUND SERVICE (USA) SCALE 1"=20' LEGEND EXISTING PROPOSED ASPHALT PAVING CONCRETE PAVING BUILDINGS GRAVEL SAWCUT LINE CONSTRUCTION LIMITS uMIT ROCKERY TREE W/PROTECTION Coco CURBING CONTOUR (INDEX) CONTOUR WATER LINE STORM DRAINAGE LINE SANITARY SEWER LINE POWER / TELEPHONE LINE / GAS LINE / WATER METER/VALVE/FH / STORM CB/MH / SANITARY SEWER MH/CO / GAS VALVE/METER / STREET LIGHT ASSEMBLY / TELEPHONE RISER/MH / TESC Notes: / / 1. PROVIDE PERIMETER PROTECTION AT AREAS OF DISTURBED SOIL / / 2. COLLECT SEDIMENT LADEN WATER AND ALLOW SEDIMENT TO SETTLE BEFORE DISCHARGING TO STORM SYSTEM. FILTER IF NEEDED. / / 3. MONITOR DISCHARGES FROM DISTURBED SITE TO ENSURE SEDIMENT AND SOIL DOES NOT LEAVE SITE. 4. KEEP VEHICLES ON PAVEMENT. DO NOT ALLOW SOIL TO BE TRACKED OFF SITE. 5. COVER SOILS NOT IN WORK WITH SHEETING OR STRAW IF THEY WILL BE LEFT MORE THAN 7 DAYS. 6. MAINTAIN EX PAVEMENT FOR WORKING SURFACES AS LONG AS POSSIBLE. KEEP PAVEMENTS CLEAN. 7. COORDINATE WORK AREA FENCING WITH COLLEGE TO MAINTAIN ACCESS TO CAMPUS AND SEPARATE CONSTRUCTION AREA. ^ 8. CONTROL DUST ON SITE. SPRINKLE BARE SOILS AS NEEDED. DO NOT OVER WET SO AS TO CREATE MUDDY RUNOFF. 9. SEE CITY OF RENTON NOTES ON CO.01. CONSTRUCTION RECORD DRAWING THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE PREPARED BY COUGHLIN PORTER LUNDEEN AND HAS BEEN EDITED TO REFLECT FIELD VERIFIED INVERT AND RIM ELEVATIONS OF THE STORM, SANITARY SEWER AND WATER MAIN SYS CE S. FIELD CONSTRUCTION VERIFIED INVERT AND RIM IN MARCH 2O17 COUGHLIN PORTER LUNDEEN, INC. DOES NOT PROVIDE ANY WARRANTEE SUCHSINFORMATIONACCURACY PROVIDED R B yOTNESS OF HERS UPERMIT# U15000494 AUTOMOTIVE TRAINING CENTER RENTON TECHNICAL COLLEGE RENTON WASHINGTON Date: Date: Date: Date: DATE: 04/30/2015 FIELDBOOK: PAGE: C2.00 TEMPORARY EROSION CONTROL PLAN SHEET: 5 OF:13 R-381805 rr W I- z W U 0 z z_ Q rr w O O Not Used Not Use 2 Y MAX. DRAINAGE CAA-P TRIM GRATE FRAME SEDIMENT AND DEBRIS v y + i f T [YVERFLO+iV BYPASS tr _I BELOW INLET GRATE DEVICE P Ill. FILTERED WATF,R 1 I ' A A h sEeTia a VIEW DRAINAGE GRATE - RECTANGULAR GRAB S41UNN BELOW INLET GRAT? GFVI ISOMETRIC VIEW RETRIEVAL SYSTEM (TYP.) 6VERFLOW BYPASS(TYP, NOTES 1. Slze the Bnlow Inlat Grata DeVlca (BIGD) farthe storm waters4uctura itwill service. 2. The BIGD sha11 have a bullt-In InIWflow relief system (ovenlow bypass) 3. the rattleval system md8t a!=Gw ramovai of the BIGD wlthoul sp.II rig the Dalledad maierlali. 4- Perform maln(er.ance In accordance with Standard Sperifcal nn "1.3(15). � � SM. PLAN — 216.30 `'I"I.L3�IC ti5'OitKS CATCH BASINFILTER 0. VARCTi 2O08 JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS. 6' MAX. POST SPACING MAY BE INCREASED TO 8' IF WIRE BACKING IS USED 2"x2" BY 14 Ga. WIRE OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC MINIMUM 4"x4" TRENCH BACKFILL TRENCH WITH NATIVE SOIL 2"x4" WOOD POSTS, STEEL FENCE POSTS, REBAR, OR EQUIVALENT z N NOTES 1. CONDITION OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. 30-100 SIEVE SIZE (0.60-0.15MM) FOR SI LT R LM ADS (ASTM D4751) 50-100 SI EVE SIZE(0.30-0.15MM) FOR OTHER FABRI CS WATER PERMITTIVITY ASTM D491 0.02 SEC^-1 MINIMUM GRAB TENSI LE STRENCHT(ASTM D4632) 180 LBS. MI N. FOR EXTRA STRENGH FABRIC 100 LBS. MIN. FOR STANDARD STRENGHT FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30 % MAX. ULTRAVIOLATE RESISTANCE(ASTM D4355) 70%MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2HAV 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY. 3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDIMENT. 3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. p1�Y �� STD. PLAN — 214.00 + a� + PUBLIC WORKS SILT FENCE DEPARTMENT MARCH 2O08 r /n PP winr nnnr nnn%nnr rrni inr viv nvi vn�vnrn CORNER POST 2.875 INCH O.D. CONCRETE BLOCK NTS Construction Fence 3 3 -4 (1.2m) 1 D -25 \ m (3-Bm) ADJACENT ROLLS SHALL TIGHTLY ABUT SEDIMENT, ORGANIC MATTER, AND NATIVE SEEDS ARE \ CAPTURED BEHIND THE ROLLS 1 ROLL SPACING DEPENDS ON SOIL TYPE AND SLOPE STEEPNESS STRAW ROLLS MUST BE PLACED ALONG SLOPE CONTOURS 3"-5" `. (75-125mm) 8"40" DIA. 4 4+t (200-250mm) LIVE STAKE NOTES 1"x 1" STAKE 1. CONDITION OF USE 1.1. SEEDING SHALL BE USED THROUGH THE PROJECT ON DISTURBED AREAS THAT HAVE REACHED FINAL GRADE OR THAT WILL REMAIN UNWORKED FOR MORE THAN 30 DAYS. 1.2. VEGETATION -LINED CHANNELS SHALL BE SEEDED. CHANNELS THAT WILL BE VEGETATED SHOULD BE INSTALLED BEFORE MAJOR EARTHWORK AND HYDROSEEDED OR COVERED WITH A BONDED FIBER MATRIX (BFM) 1.3. RETENTION / DETENTION PONDS SHALL BE SEEDED AS REQUIRED. 1.4. AT THE CITY'S DISCRETION, SEEDING WITHOUT MULCH DURING THE DRY SEASON IS ALLOWED EVEN THOUGH IT WILL TAKE MORE THAN SEVEN DAYS TO DEVELOP AN EFFECTIVE COVER. 1.5. AT THE BEGINNING OF THE WET SEASON, ALL DISTURBANCES AREAS SHALL BE REVIEWED TO IDENTIFY WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHOULD BE SEEDED WITHIN A WEEK OF BEGINNING OF THE WET SEASON. AT FINAL SITE STABILIZATION, ALL DISTURBED AREAS NOT OTHERWISE VEGETATED OR STABILIZED SHALL BE SEEDED AND MULCHED. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE BEST TIME TO SEED IS APRIL 1 THROUGH JUNE 30, AND SEPTEMBER 1 THROUGH OCTOBER 15. AREAS MAY BE SEEDED BETWEEN JULY 1 AND AUGUST 31, BUT IRRIGATION MAY BE REQUIRED IN ORDER TO GROW ADEQUATE COVER. AREAS MAY ALSO BE SEEDED DURING THE WINTER MONTHS, BUT IT MIGHT TAKE SEVERAL MONTHS TO DEVELOP A DENSE GROUNDCOVER DUE TO COLD TEMPERATURES. 2.2. TO PREVENT SEED FROM BEING WASHED AWAY CONFIRMED THAT ALL REQUIRED SURFACE WATER CONTROL MEASURES HAVE BEEN INSTALLED. 2.3. THE SEEDBED SHOULD BE FIRM BUT NOT COMPACTED. 2.4. IN GENERAL, 10-20-20N-P-K FERTILIZER MAY BE USED AT A RATE OF 90 POUNDS PER ACRE. IT IS RECOMMENDED THAT AREAS BEING SEEDED FOR FINAL LANDSCAPING CONDUCT SOIL TO DETERMINE THE EXACT TYPE AND QUANTITY OF FERTILIZER NEEDED. DISTURBED AREAS WITHIN 200 FEET OF WATER BODIES AND WETLANDS MUST USE SLOW RELEASE LO-PHOSPHORUS FERTILIZER. 2.5. THE FOLLOWING REQUIREMENTS APPLY FOR MULCHING 2.5.1. MULCH IS ALWAYS REQUIRED FOR SEEDING SLOPES GREATER THAN 3HAV 2.5.2. IF SEEDING DURING WET SEASON MULCH IS REQUIRED 2.5.3. THE USE OF MULCH MAY BE REQUIRED DURING WET SEASON AT THE CITYs DISCRETION IF GRASS GROWTH IS EXPECTED TO BE SLOW, THE SOILS ARE HIGHLY ERODIBLE DUE TO SOIL TYPE OR GRADIENT, THERE IS A WATER BODY CLOSE TO THE DISTURBED AREA, OR SIGNIFICANT PRECIPITATION IS ANTICIPATED BEFORE THE GRASS WILL PROVIDE EFFECTIVE COVER. 2.5.4. MULCH MAY BE APPLIED IN TOP OF THE SEED OR SIMULTANEOUSLY BY HYDROSEEDING. 2.6. HYDROSEEDING IS ALLOWED AS LONG AS TRACKIFIER IS INCLUDED. HYDROSEEDING WITH WOOD FIBER MULCH IS ADEQUATE DURING THE DRY SEASON. HYDROSEEDING WITH WOOD FIBER MULCH IS ADEQUATE DURING THE DRY SEASON. DURING THE WET SEASON, THE APPLICATION RATE SHOULD BE DOUBLED. IT MIGHT BE NECESSARY IN SOME APPLICATIONS TO INCLUDE STRAW WITH THE WOOD FIBER, BUT THIS CAN BE DETERMINED TO GERMINATION. 2.7. AREAS TO BE PERMANENTLY LANDSCAPED SHALL USE SOIL AMENDMENTS. GOOD QUALITY TOPSOIL SHALL BE TILLED INTO THE TOP SIX INCHES TO REDUCE THE NEED FOR FERTILIZER AND IMPROVED THE OVERALL SOIL QUALITY. MOST NATIVE SOILS WILL REQUIRE THE ADDITION OF 4 INCHES OF WELL -ROTTED COMPOST TO BE TILLED INTO THE SOIL TO PROVIDE A GOOD QUALITY TOPSOIL. `�Y STD. PLAN — 213.40 as + PUBLIC WORKS STRAW WATTLES �N LOB DEPARTMENT MARCH 2O08 DRIPLINE NTS Tree Protection 4 NTS Not Used 8 UPERMIT# U15000494 Approved By: Date: City of Renton Std Plan 216.30 NTS NTS Approved By: Date: I I Catch Basin Filter Silt Fence Straw Wattle Approved By: Date: Approved By: Date: I A• Jq DATE: of wasy SURVEYED: SCALE: VERTICAL: NOTED .. CITY OF AUTOMOTIVE TRAINING CENTER / / HORZONiAL:•NAD 1983/1991 �► 04 30 2015 COUGHLIN PORTERLUNDEEN DESIGNED: RENTON TECHNICAL COLLEGE FIELDBOOK: A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION DRAWN: LBJ � RENTON RENTON WASHINGTON PAGE: 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 ONE INCH DATUM DRAWING NO: 43667 SEATTLE, WA 98104 F: 206/343-5691 CHECKEDJAJ AT FULL SCALE Planning/Building/Public Works Dept. 1 GI S T F R ��� APPROVED: IF NOT ONE INCH SHEET: OF: ()NALE LNO. REVISION BY DATE APPR SCALE ACCORDINGLY T"E"S.C. DETAILS 6 13 R-381806 N0.27 05 W 828.22' - - - - - - - - - - - - - - - - - - - - - - - - Call before you SDMH R1M=342.6 FOFSITE PS STORM SYSTEM CONNECTS TO CITY SYSTEM SOUTH ssMH RiM=338.84 o.F=339.Bo D j g. 8- I - NEAR KIRKLAND AVENUE & JEFFERSON AVENUE SDMH R1M=340.08 CL CHAN 8'CONC(N,S)=32Z69 /E 18'CMP(S)=3Aalk 35.50 SSMH R1M=340.68 D or-800-424-5555 - O.F.=337.18 KIRKLAND A VENUE N. E. CL CHAN 8'CoNC�S)=330.78 LIMITS OF WORK CB R/M=340.04 UNDERGROUND \ lE 181CMP(E)=332.98 ,° "" ,� q� ti0 o ' CB R1M=337.82 , , ° a' ,e' 0' ,p' SERVICE (USA) _LJ - - h e CONC WALK W� W ti" e°0ti 0 J 0 10 20 40 q 4 CO �k° q o� ° �b°6aq o'ONC WALK _ W ya ° - - '� °t� a° ASPHALT I� 0��1--� - �� �- 0" T4u1APL -_1 °-��'d4�LE,e------------------ -- �h " - - e -3$2-- 4'MAPLE t / °�0 DRIEWAY 340 t'� - - �- + ----0 _ -- ,-----s- ---- - ------ +--342---------------�4�Z-"° % + 14M1tt3L� \ 7J 7 S SAP 14luf �4'L7APL� �+ J_ __�°---j�LT -- \gyp --_So_ 0� -�- -- ��_ - -_ --r __-- __-- -- -- - ---777 - SCALE1=20 Il "cIL" ---- -- - - ._ 342-�8 a- "ti ° SD -r-----SD s-- S -° �--5 -� ti a`3B " ti ---- S ° +" (IS S h a` Y�n - may_ ee-a ? r6�° 1 " � 6 _ o k o a q 0 ° 5 6 + 9.0/ + +++ + q k -�� oK���V+ VLEGEND ■a �° X awn b wn w �n �w j n 20 awnr � b - ES' k : 0 INCREASE ie'fH AT POROUS PAVING +' m \ ,/ cHAWLWK AS REQ D TO ALLOW FOR CURB CUT I _ _ 6' iNCNc-- - _ _ _ _ _ _ L - y� ° 6' cHA/nlcc - y"k 20 , c " - - EXISTING PROPOSED (IS - �- -�- -----� - \ r - T T A T ��-o r T TE " 3--- _____ TR342.0��\ ti ' n _ \ SD - SD SD SD SD SD SD D SD SID SD �wn " D / _ 6 -0 TYP PER D - - - \ IIII ASPHALT PAVING 1�.01 PAVING PLAN - - r 339.00 CO ° / I 9 - . - . r r r r ..: r P� RHANG - / 740 SF NEW I _ " '" I CONCRETE PAVING ""> Imo- IMPERVIOUS AREA .:. V; 40.00 . . c -.r. � » .. , . q'_ - PERMEABLE _ , CONCRETE PAVING af Q`� 328. �9 ;�I- y� TC 339.Ot r` - $ MH Rl =341.0 r ° 40'UTIL TY RE C w �,° LIMf, BC 338.5± EX) p J 339.00 - \ ° " b" tiq"0 / 2-J" POWER EX CAMPUS SDMH RIM=342.83 339. - TC 341.95 I I I _ ,, r r lE 6 PLS> (NE)=336.76 CB R1M=340.6 q' ti -r -' �� � �+,° � BC 341.25 EX � � BUILDINGS C f lE 8 PUC(SE)=335.76 /E 8 PVC(E)=333.19 \ + s 2-3" SECURITY & COMMUNI oN STORM MAIN lE 8 PI�C(E)=333.73 3 ( ) I l� °� I lE l8'CMP(N)=332.96 /E 18"CMP SN-333.19 hb '. 2-2" FIRE ALARM lE 18 CMP(S)=333.63 341.50 EX z ( )- TC 342.92 I GRAVEL w - " +' r r r 3 Q4 CMP(S)=33236 PERMEABLE 339.00 CO o qs,�9� 3 .20 341.00 BC 342.42(EX) I- TC 339.25 18 CMP(W)=33206 1 D RECONNECT ALL ROOF DOWNSPOUTS 4 341.60(EX 341.65 341.75 U I I BC 338.75 EX) 339.40 CONCRETE ° C RECONNECT ALL ROOF DOWNSPOUTS I "� b CONSTRUCTION LIMITS LIMIT PER DETAIL C3.10 " wQco TO EXISTING RAIN LEADERS IN SAME K �"" \ r a LOCATIONS. SEE ARCHL PLANS (TYP) TO EXISTING RAIN LEADERS IN SAME AISE EX VAULT LI TC 342.60 C3 I APPROX 1500 SF g �' \ ° - ' IE= 4.2 BC 342.10(EX) ROCKERY � C>�7t z J "ob \ CB R=338.77 \ LOCATIONS. SEE ARCHL PLANS (TYP) NEW GRADE EW 80 LF 6 � IE 8'P (NW)=335.77 � / 3 1.3f VAULT I D ®2.0% MIN .. d Q VA 342.60 MATCH IX z 40 LF 12" SD MATCH TREE oiL/H2o A MEABLE q A c 33 . @ 0.5% 342.5 Q SEPARAIOR P VERS d ' CB RIM=338.57° C 33 :00 I r L _J q1 I, 342.50 CURBING ER DETAIL 4.03 8"C0NC=337.37� S / / / SD ,0 D �_°' 33 :00 \ Y � EW AREA DRAIN \ " 6'APPROX 1500 SF I=338.60 d I \ RD RD RD D RD - o I TC 342.40(EX) I D CONTOUR (INDEX) -/X- -100- I \ co o \ TYPE �2 CB ON EX 8- CHIP � W OOF DRAINS PER ARCHL a o I , , =an= ' =an= Cn=an= Co=any o=any �o=a �n=a �n=an� CS]SC o vi c3.10 d / \ CONNECT TO EX TC 39.75 `�� RIM=3 9.40 (IN PLANT) �34 '13 CONTOUR -goo - - 98 - > CONNECT TO SITE STORM I bA 339.40 ARC ' Bc 39.25 IE=335.2 (EX PIPE) IN MATCH R 339.50 -� ( STORM DRAIN NNECT TRENCH DRAI � WATER LINE NEW TRENCH DRAIN �: co D - _ SD O �16� c IM=339.48 SD SD sD D SD SD : ' 338839.15 CB ITH 6-INCH PIPE STORM DRAINAGE LINE- SD - t r r.. �o=338.75 BC 339.75 EX) r ' rkr / a 9 9 c +.� _� -' - .. _ _ 8'Pt/C =33 g L O POURED I PLACE - 141 ; w +' ( o 9.1 -33 25 k SANITARY SEWER LINE . + � � -� � " v o � . CB R 39.15 b ryti ° '° v . CURB CUT + CONNECT TO RD a77 ° J POWER 339.50 EX SITE STORM � � +v s . � o NEW 93 LF 6 Q 12''(12" CB IN GUTTER o cn 339.50 339.50 2342.33 TELEPHONE LINE - T - 340.00 500 SF NEW d FFE FFE SD ®1.0% MIN MATCH EX o REPLACE ROUGHLY 24 LENGTH IMPERVIOUS AREA I 650 SF NEW I s I ��11 GAS LINE - GAS OF PAVERS WITH KINNICKINNIK 342.51 in / IMPERVIOUS AREA I RECONNECT ALL ROOF DRAINS TO SITE STORMPER REVISED L1 02 PLAN TC 341.00 342.00 I / / ROOF DRAINS TO EX I WATER METER/VALVE/FH N a BC 340.5 EX) 0 R 340.50± SYSTEM. SEE ARCHL FOR NEW ROOF & I I NEW 45 LF TRENCH DRAIN \ } GUTTER (TYP FOR ALL BUILDINGS TO REMAIN) I SITE STORM SYSTEM I / RIM=339.35 NEW CB I STORM CB MH L J ■ CB Rl=338.84 "339.75 i 6 SD @ 1.0% MIN I� RIM=339. 5 / � a I / IE=337.35 ��IE IE 6PoFG(S)=337.5j� � q IE=338.25 6P1�(N)=33684 "� I NEW K3 BUILDING 8-INCH PIPE AT / lE 12 C C(NE�' 34ti99"�9, r� / d �' ROOF DRAINS I / Q ' k �v �3 � �' SANITARY SEWER MH/CO OO • \ IE 12 COZ((W)=#�4 4 , ' ' SEE DETAIL 8 TYP I I PER ARCHITECTURAL kti�" k1 GAS VALVE/METER M 0 _ _TC 342.50 I o C3( ) i \ FF=339.5_ DOWN SPOUT2\ , 3 ° \\ I I J BC 342.0 EX) ALT 2 Q STREET LIGHT ASSEMBLY NOTE: REFERENCE 2/A6.12 K1 WALL d BUILDING WORK POINT " N SEE I I PER ARCHL I 1 WITH sLA SECTION WITH RESPECT TO GRADING TELEPHONE RISER MH ■ T wrrH cEN Aron I o I SEE ARCHL SEE DETAIL 8 °� 342.19 �¢¢ i\ 1 c5.2o REQUIRED AT LOUNGE I / I ) �� III `r"�' I H o I , ARCH'LPER (TYP) c� o MATCH EX o TC 344.25 IIIII o - qti ^� BC 343.75 L----I " ti^ 41 a ,/ MATCH EX I N III I , 339.50 339.50 GRATE PER \ ,k� f ► I I � HOLD BACK ROCKERY FROM LOUNGE � FFE \ �346 I WALL AS REQUIRED TO SUIT GRADING I ARCHL I III I I H RECONNECT REMAINING k�0 C I / \� iJ J II \ TRENCH DRAIN TO EX 339.00 NEW 6 SD I I I a' f STORM SYSTEM C� 1.0% MIN I ~' _ o _ 339.50 , . �... v _ g. 0 nyp: 0` \ B °ED_ .� o v: -. -v.. v.� ev.. v: •o. ,�- -+... -v• 'Y � t+ IIIII l o ^ / I IIIIIIJ lllll --- ° I qo LIGHTI �I� I I , I I RECONNECT ALL ROOF DRAINS TO SITE STORM 00 wQ VAULT ° - Q° I 0 / PER ECT a/ ALL STORM DRAINAGE PIPE AND STRUCTURES ARE IIII IIV .� I I l SYSTEM. SEE ARCH'L FOR NEW ROOF & CO ! �;, ,.c�6PVC=334.57FD339.50 0 /1111 IIIIIIIII , ° , kb \\IIII GUTTER (TYP FOR ALL BUILDINGS TO REMAIN) CO ���'� CO (IS as so NEW 43 LF / / PART OF THE PRIVATE SYSTEM WITHIN THE RENTON D SD D - SD @ 1.0 o MIN TECHNICAL COLLEGE CAMPUS. NO CITY SYSTEMS IIIIIIII } II co SD SD CB WILL BE MODIFIED OR EXTENDED IN THIS PROJECT. SS C S] CD=Q C co CL]SQ CD=Q SCCnC OD Ci]SC[ CL]= C QS]C CCISC[ � t Q' CCI \ / NEW TYPE 1 CO a ° - - - 0� I _ , , 339± 339.50 - RIM _339.5 \ IIIII IIII II II I� ,q' / RD RD RD RD RD M I - - °9 s CO _ � . I I Q v1I a IIIIIII i11 d G SEE STORM WATER NOTES ON CO 01 / REVISE EX DOWNSPOUT " tie 342.5 z q L _ 'k--- - MATCH IX k�� � a WYE INTO EX STORM n I I I -- II COORDINATE W/ NEW „ = ' - z i� CONFIRM INTERNAL BUILDING FLOOR DRAINS ARE I IIIIIIII ' ' OBI �' IIII "�9 ROOF AND GUTTERS I IE 335.5f / 339.20 +�� / ,k � 7 �, IIIIIII IIIII _ ' \ CB RlM 338.56 /l NEW BIKE RACKS �°c / �" /t iF/ '� -I ry�� �� ROUTED THROUGH OIL /WATER SEPARATORS AND CB R1M=339.33 IIIIIII I I IIII /tl 8PVC=337.51 / RECONNECT ALL ROOF DOWNSPOUTS RECONNECT ALL ROOF DOWNSPOUTS PER ARCHL +� �b k �1 S TO SEWER SYSTEM FOR DISCHARGE. lE 8 PVC S=335.73 II III �` - - r I I I / H / TO EXISTING RAIN LEADERS IN SAME TO EXISTING RAIN LEADERS IN SAME ,hqb IE 12""CONC(W)=335.33 I - d / LOCATIONS. SEE ARCHL PLANS (TYP) LOCATIONS. SEE ARCHL PLANS (TYP) y � CO / RESTORE AREA 725 SF EX IMPERVIOUS NEW FACILITY SIGN 339 ,^ ss ///III- - - - - -° III ` PER L SCAPE CONVERTED TO PLANTER PER ARCH 0 / f ^,� - +"6 CONSTRUCTION RECORD DRAWING #lti V I I \ b5�q kk�0 + sue' " Sv5, ° -sv� SvDRAWING IS A COPY OF A �\I IIIIIII II II \ .k' y b� y ti �k "b _ - - ti Al' / / �q8- THIS CONSTRUCTION RECORD DRAW " k b' b' R " , t "I k� k� ""� k,� "�" / % - '"^® CAD FILE PREPARED BY COUGHLIN PORTER LUNDEEN AND " c^^ /i;�reP�= e o ti h ( RHANG o b' " o- k o- ., k " / / e _=_ _-_ �_ _�_ _ _- _-_ ' -_ _-_ - - _ _ _ _ _ " ' _ _ _ -�_ _� _ _ _ _ � _ _ _ _ � BEEN EDITED TO REFLECT FIELD VERIFIED INVERT AND ti- _ 6--- 9 - --_-- �--------- -�- 0 _ �tik HAS --�---------- -- --- - - - - - '- --(has D€+ - + __--------346-----------� --- �+-------------------- 34s + /� 34 - �titi RIM ELEVATIONS OF THE STORM, SANITARY SEWER AND 1- - - - - - - - - - - - - - - ' / k�' \ k "� �L - _ -_ _ _ _ _ _ - - - _ _ _ _ _ 8'oEc�b ti LIMITS OF WORK WATER MAIN SYSTEMS. FIELD VERIFIED INVERT AND RIM - 350-- - I 3gg-- -350 - f0 '+ ✓ _ = 358-- = 358------------ ------------ --- _ h'6' ti� �`�✓ ° - - CENCMARCH 2017NSTRUCT10N _ _ _ �_ - - - CB 1M=352.69 IE6yPV%E)=350.5 ----------- ---- __ _ ___ ___________________________T- - ____________-__ __ - - _ LIMITS OF WORK !_ _- - - - - -_- = 354 - - - - - - - - - - - - - - - - - - - - - - - - h' - - - 9 c C HH -3P9 E -540.0 - - -++"_ h COUGHLIN PORTER LUNDEEN, INC. DOES NOT PROVIDE ANY / / _ _ - '� - - - - - - - - - - - - - - - - - - - - -_ _ - - - - IE _ -' -4- - - - - - - - - -yam - -_- - - - CT CHAN a PAc w -338. s q +'"q� C WARRANTEE AS TO THE ACCURACY OR COMPLETENESS OF - _ 7-- - - - _ _ - - - I � � -�- _ _ _ _ - - - - - - - - - - - - - - - (��6 \ O �� ° SUCH INFORMATION PROVIDED BY OTHERS. 355�(IX) ��- =_----------------------------------------------- TS\ y'q i'--f---=---- o----�_-- �5$------------------- ------ ) j6 11- -� - I \ yyq GRASS 5., \ ^ �' ��Rq \ h 35 q -%N BL / hq' \ ,P s5° \ \ \ ti`° I ' oo y ' / UPERMIT# U15000494 q 6L +5t(EXY " e ob t t q` \ q e. I _ g' �` Sys / �° / �5 �e i �� �6 - �6 �6 ro5 \ po-_ 6�� � ` °..'v� ��ti gti yti^ ebb y' Cgvc WALK °ql I ye 0�6 °tik ,� CONC WALK ,ry °�^ °, qe^ A� - a a o6 � 0e I ^�5 I bti - I yti kph C Al h' e' _ S 5 5 p Approved By: Date: LIM U IT r IT 'NMIT LIMIT � LIMIT LIMIT LIMIT T UMIT4t�11'9 w". 0 yy. S d J y yy °yeti 0" yy. / 6ti y� \ \�7 lE 6 PVC(NE)=349.82 LT DRIVE ® °\ �e 0 \ y-i'� l ASPHALT C '66 lE 8 PVC(S))349.52 ----+ i \ \ / / / / Approved y `'17 \ `O� o� c!•� �^ lE 8 PVC $E-349_62 / / LIMITS OF WORK � 6� S h \ 1 \\ ti 6 A roved B Date: b°yy yye: yy W W 4E 12 PVC(NW)=347.02 �/ W \ 6 W - sb° W �hq ` W I W ° W n� a q " 6`�W \ 6°aq W°ge y ` 'a \ y o° \ y ati \ ° q` q \ y q ��' p p y Approved B Date: 6 6 6 b h T ^l y �J � ^J ^J 'S k' 7 k � - - 362 e CURE STOPS °°' T°-- \ �\ _ �� -_ �5�-_ ----- - _ ���_ - - 6 �> - Approved By: Date: `� i +' \ \L -1 %may -- ----- _ T \ _ _ �� �- � VERTICAL, NOTED CITY OF AUTOMOTIVE TRAINING CENTER / / OF WA S� O SURVEYED: SCALE: AS HORIZONTAL: NAD 1983/1991 �► 04 30 2015 W COUGHLIN PORTERLUNDEEN DESIGNED: RENTON TECHNICAL COLLEGE PAGE: OK: ti A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION DRAWN: IN RENTON PAGE: LBJ RENTON WASHINGTON DRAWING NO: 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 ONE INCH DATU M 43667 �� SEATTLE, WA 98104 F: 206/343-5691 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. C3.00 NAL 1 //�1/, NO• SCALE ACCORDINGLY GRADING AND STORM DRAINAGE PLAN /� REVISION BY DATE APPR APPROVED: SHEET: 7 oF:13 R-381807 12" { ADA FRAME & GRATE WITH LOCKING MECHANISM min1.,n. Ilmlraa' PIPS j, w [aeenato4i J }�O•� [i5m[56tIl..P max, Ireik43F,P�6mne•hedtllr.PPIPE ALLOWANCES PIP&trr+e""W 6I MIN 12"x12" SQUARE GRATE W/PEDESTRIAN MAXIMUM � 4�SPACED GRID SIMILAR TO ADS H-10 HINGED. FRAME AND VANED GRATIE PIPE MATERIAL AMETINSIDQIAMEiER PLASTIC VALVE BOXSET FLUSH W/ FINISHEDREIRFORD,80M I-h'r'° W/ 8" DIA LID LANDSCAPE GRADE PLAIN CONCRETE 12'""1a^ °''�'`PI''r-urJeym FINISHED GRADEAiLMETAL PIPE 15�• �,��I Inrol # @ GRAVEL THREADED CAP DUCTILE OR CAST IRON FRAME WALKWAY as CPSSP* 12• • A=4` rnkr, 2r I,a, a-W J9Pm•' rr n /VA//VA//VA//VAO �VA�O n tsTO. sPEc.9 anp $ �,• I,p, 3 18 \/\/\/\/ \/\ � \ 12 DIAMETER � FINISHED GRADE � � /iVA//VA//VA// // � //O� s� (STU. WAt1PVC rs A. foetal an-d Concrete Pipe w SOLD. WALLP051211I} ®PAVING NOMINAL PROFILE WALL 1s. Meddling Fnr Flexlble PIPE 1211 2 �ii0/�Ai 00 AO A / Z ADAPTS TO VARIOUS PIPE B' 4R 12' (STT1. SPEC.9 t1:t.1zp)) w * 9TQRMSETWEERCORRUGAD POFEETHI�LENE 2" PEA GRAVEL FILTER FABRIC SIZE AND MATERIAL �I �T� � ��*;�,.x� "��' a>tlDlePIpet�OT&t3: SEE PLAN FOR INVERT ON _ CONC. CL. 5 (3/4) TW ff BAR HOOP P FiFOR HEIGHT ', P"Ide pnlfum -suppo'I p�dar t wr�Ig, (� TWO i aAR HOP5 FaR 1� HEIGHT f 1 2, Hand lamp under haunrk-e% 8"0 DIP v RECTANGULAR ADJUSTMENT SECTION 3, Compp t teddIng-nateclel to t 6% max, Censlty: dIrGc�Y Z w avm plpa, hand Lamp omly, FIBRE JOINT PACKING 45' (1 /8) BEND a,l!� Ise reh, 4, 5tra'Fxs:alwA-an arid F�aparaduri of Trurlch' In sanllbry z L r WtV8 sddlOtl of 1I14 b!YKidrd VVSDD'F. >,PWA U z f4 r rrnus,rIra _ ixDecl ocallorcs for IMISCiI widthW and trllrg 1 /8 BEND Q ` � NOTES 90TP"`Ih° ��es rKe rrin, opllorz. The pi pe xone will be the adual Mrich width. I" mill num concrete wldih shall be 1 ' I.C. = 18', 1. As aoce (able aftematives to the rebar shown In the PRECAST BASE grbrel bxxcll Grbvel tin rrr ELEVATION SECTION, fibers {placed according to the Standard Specificatiansi of 1W Pips pe air m �valbne wtwn ep1«c11s1 3, Trer1ic s' I i111 '19II anrarTat !a "Baekkfll Ilr 5eavar 9 � Tremche5' IrI the sanliary seu�era 5ecllan orihe NOTES: NTS wiro mesh having a minimum area of 0.12 square Inc#1es per foot shot WSOOT(APWA s.2-ldard apeca`lce'Ir3nG, gxoepl LFIBI DIA PER PLAN LLI he used with the minlrnan required rebarshown In the ALTERNATIVE p I rga p plpe I 1. 12" PVC DRAIN BY CARBON ADS OR APPROVED EQUIVALENT. Area Drain PRECAST BASE SECTION. Wire mesh shall not be placed In the ocks cc lu=r a a r then 1' erinol ai d emeler 4 khoCkouts. 8. Pipe ' Leh h►sl�Ilarlltrrt seal I not 99 asec! In pfa tyot;ltflll ma;aril, #3 BAR EACH CORNER 9, Stu'Sedding Matoriai for Flexlulo P'Ip¢ In aggrcgalos DOWNSPOUT PER 2, The knOaDUt diameter shal not be greater than 217. Knockouts shal aectltal iy th,§ WELD UT•1,gp7 A slarxirffd spcclflCdtI0r- 1 2" , O have a wal thickness flf 2" minimum to 2.5" maximum. Provide a l.5" Eat• she materlal speelftMans, 10" / ARCH L PLANS minimum gap betwuen the knockout wall and the outside of the pips. » AND SPECIFICATION After the pipe Is metaled, fill the gap vrtth joint mortar In accardancu Rlgld Pl a f� OTFS: 9" 5 8rr 2 RAISED 43BAR EACH SIDE with Standard Specification 9-04.3. RII:aa cenpactlan IlmIts s+lawn an ails Oar ere for pipe » / LETTERS O3. The ma;amurn depth from the finished grade to the lowest pipe invert �ore5lraletlon In are ember.kmerr� Foe pipe Cor�srLecllon 8 3 4 SDCO—STORM I I THREADED WYE AND ADAPTER shot be 5'. In a imr.-Gh,1ne horiznntal Ilmft of tl ae pipe c nirmactlon AS NEEDED FOR DOWNSPOUT zone shall be the walls of She ;rerx+r, SSCO—SANITARY n #3 BAR EACH WAY d. The frame and grate must be Instaled with the flange down. J, All staml amd alvr Inum plea arid plpe,archa5 shall bo 4 DCO IN LANDSCAPE AREAS t t CLEANOUT WITH Q PRECAST BASE $ECTION Installed I-n accordance wllh design A. 1 8" RAISED 5. The Precwd Base Section may have a rounded floor. and the walls may 3, Comcrate pipe with elliolcel reinfgrcamant shall t5e P TT.I BRc�III materlal vlacad In 0,5' lowe Iayets and ] „ THREADED CAP be sloped at a rate of 1:24 or steeper. Ins'aIIE'J I r accordamoe with deslgr A, tL d compsrried t� 95% mexlmum darmlly, 2 �/8" 1 2 WIDE A. ConCrate pipe. plain or wit*1 clrcula' raln`Drr�am shall Z 3 4 BORDER 6. The opening shall he measured at the top of the precast base sectcn' 4g I nstal led W11h daslgr. A. Me,.khod S or C cA5mpaction WSDOTIAR4 A) 8" 7. Al pickup hales shall be grouted full alter the basin has been placed. 5, O.D. In mival .b the ixitsift dlalnttdr of a pipe b- ;ho Warlda'd auttlde spar' of pipe -arch. rho dlm&-*Io a shriven a3 15" 8. AI grade rings and casings shot be set In mortar In accordance uuftli O,a, wliK 3 m xlmutr +fall ae 0.0. , urNl O,f), equals Lo Standard Speclflcatlon 9-04.3. 3'; at whlch palrhl 3' sr3all oe ;reed, i'-0`fcs 11$meters 1Z'Innyign 42" Fmd spafy, Ihrmugh 5T. 7-17 rpr diarns lers WaateT 11-tah 42" 9nd spa-ir:. Ih9n'w Ulan 50', "3 BAR EACH CORNER 19" MIN. #3 BAR HOOP SEE NOTE 1 Pipe Mlrl. list. SIZO between harrels 6rcular pipe oonc,_ LOPE. CMP �62117!Teter) 12" to 24' 12" 30" b, 96' dlafn, 12 1021, to IaT 48" pipe - arCh metal only (span) 1.8" to 36" 12" 43" to 14 " Span 13 148- Lo 199", 48" W/ CONCRETE RING CONCRETE PAVING —V--- OR FINISHED GRADE --� PLUG SHALL BE SEALED IN SAME III MANNER AS MAIN w�v-i„ �it�•: j:•r: !..•' :.',?� •� i;•;,;'.. ��„��'!"��.•_:. •• t:�: •��•1� { � ;•�- -• jr-: �,'�'�y:••: NOTE: -- ___=====1 SEWER JOINTS •, . :� . + .:a .:.4:� .; ,,: �; �:k•.; .: .,::. .... ,�., ,•.,;• -� �:•:••--,.•�.;. 1. USE ONLY FOR SIDE SEWER AND SERVICE DRAINS WYE OR 1/8 BEND' " p �' IF �� I 1 3" EXTENSION J.T. FILLER (TYP ALL t t AS REQUIRED AROUND WHEN CONCRETE ALTERNATIVE PRECAST EASE SECTION IS PRESENT FERNCO BOOT STD PLAN _ 200.00 PUBLIC WORKS CATCH BASIN TYPE I # ` DEPARTMENT MARCH 200E .5TD- PLAN — 220,00 6" SD WITH LONG SWEEP MJBLIC WORK PIPE COMPACTION �AS REQUIRED L�1N:lE'Al`13TEN'1' DESIGN AND BACKFILL ]Z,�_?C:H 08 lq MINIMUM NTS NTS NTS NTS Catch Basin TY5 Pipe Bedding Storm Drain Cleanout Details Downspout Connection FINISHED GRADE PER PLAN PEDESTRIAN SURFACE WIDTH PER PLAN PLANTER NOTE 2� CONCRETE CURB AND GUTTER PER PLAN 000000000000000 0000000 0 0 0 0 0 0 0 0 o ROADWAY PAVEMENT 00000000000000000 NOTE 000000000000000000 000000000 NOTE 2 PER 00000000000000a 0 000000000 o0000000000000000000000000000000 0000000000 /\\\\V/\VO O 0000 00000�0000 0000 000000000000000 0000C 0 o11000000000000000 000000000000000000000 v�O o o 00O�O���O� 000 o O o o O� o O� o /iv00/ /vivi � NOTE 2 \i/ o 00�00�0000�°000°0�000�00 o O000�0000000 ///��/ /00//" 24 THICKENED EGDE ,\/\/\/\/\//\/\/\/\\; O//y \\\/o \,� O/ AT PLANTER EDGE AT CURB PREPARE SUBGRADE PER SPECIFICATIONS 4" DEPTH OF PERMEABLE CEMENT CONCRETE SIDEWALK PER SPECIFICATIONS 6" MIN DEPTH OF AGGREGATE DISCHARGE SUBBASE PER WSDOT STD SPEC 9-03.1(2) 8oz. NON -WOVEN GEOTEXTILE ON BOTTOM AND SIDES. U P E R M IT# U 1 5000494 MIRAFI 140N OR APPROVED EQUAL EXTEND GEOTEXTILE ABOVE POROUS PAVEMENT. NOTES: 1. DEPTHS SHOWN FOR PAVEMENT SECTIONS ARE COMPACTED DEPTHS. Approved By: Date: PERMEABLE PAVEMENT SECTION 2. AFTER PAVEMENT HAS CURED AND ADJACENT FINISHED GRADE HAS BEEN STABILIZED, Approved B Date: CUT GEOTEXTILE AT FINISHED GRADE. (TYP.) NTS NTS p P y Permeable Pavement 10 Not Used Approved By. Date. Approved By: Date: A. JAC' AS NOTEDHORIZONTAL:.. CITY OF AUTOMOTIVE TRAINING CENTER / / Y OF WASH O SURVEYED: SCALE: •NAD 1983/1991 �► 04 30 2015 COUGHLIN PORTERLUNDEEN DESIGNED: RENTON TECHNICAL COLLEGE PAGE: OK: A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION DRAWN: LBJ RENTON RENTON WASHINGTON PAGE: 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 ONE INCH DATUM DRAWING N0: 43(i67 SEATTLE, WA 98104 F: 206/343-5691 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. C3, 1 O JAJ IF NOT ONE INCH NALE��~ 'LN0. REVISION BY DATE APPR SCALE PAVING AND DRAINAGE DETAILS / APPROVED: SHEET: 8 OF:1 3 R-381808 N027105 W_ 828.22' SEE ELEC'L FOR CONDUIT HAND EXCAVATE SDMH RIM=3426 INSTALLATION SOUTH OF SITE. SSMH RIM=338.84 O.F.=339.80 PATCH TRENCH PER PAVING SDMH RIM=340.08 CL CHAN 8'CONC(N,S)=327.69 THROUGH TREE AREA KIRKLAND A VENUE N. E. IE 18'CMP(S)=335.50 DETAILS AFTER INSTALLATION O.F.=337.18 o lE 18CM €ktWSEWER P.O.C. TO PUBLIC SEWER LIMITS OF WORK CB R1M=340.04 o CB RIM=337.82 , , F 7 W J CONCWALK - ----- ---- - - - SS -/ W W W - - W- W W S SS wcc W SS INS= W W W -940 1_ - SAP 6APLL- _ _ Z _ 14'1a4PL� _ 14- - - / DRNEWAY - �C�T _ - ---- _ _ ---- -- ��--_34z -_�_llwn°/OMM PER ELCAL 14aePc�__ _ -- - -\ ---s� SD ------sue ---- sue- --s - -�- - ---- 5 - - as ,� W RESTORE ASPHAIff - - - _ = -hr�m � -PROTECT E)� LIGHL - - - - - - - - _ �-21 --- _ ASPHALr PROVIDE 5' W1D� � �- _ING 11 n TEMPORARY ATB WALK 3 m 1lwn \ I - IF A � � � n 20 � jinn - - � �Iwn s� A �w � � �DRIuFwAY TO REST2f TRENCH - -� - /�� I CHA/NLINK -20 I - - - - - - - - - - - - EBINET PER E E L �� PRIMARY WER E E Q -- I SSMH RIM=340.68 D CL CHAN 8 CONC(S)=330.78 C/) CONC WALK W- W - V W � r L) _ Call before you .l. • Or 1-800-424-5555 . UNDERGROUND SERVICE (USA) SCALE 1"=20' LEGEND EXISTING PROPOSED \ - -s - - - - SD- - __ SD ER ELEC L D SD SD K AS SD / I umn 1 �� ! BUILDINGS FD. 4'$RASS / - I �,r0 W/'X',' DON. 0.6' Q _ - 540 � - _ = _ . 11 , ,,� V o o n �P /F o �r� In113 0 o F V� '# / M R r - OVER Al J , 20» I - ' I CONSTRUCTION LIMITS OMIT C \ 1 24'" - L - - sE 32a �9 � ,L / I ROCKERY C C>•C7t S MH Rl =341.0 40,, TIL TY RE CH _ ^� GATE \ I I w �� UMIT IE 6'PLST NE-336.76 - ( PROTECT EX IRRIGATION 2-3" POWER SDMH R1M=34283 - / I I - 5 ( ()- CB R1M=340.6 POWER CONDUIT I TREE 0 A0 p,b IE 8'PUC(SE)=33576 /E 8 PVC(E)=333.19 I ° DURING POWER TRENCHING 2-3" SECURITY & COMMUNICATIO IE 8'PUC(E)=333.73 - I / I z IV 1 C IE 18 CMP(N)=33296 /E 18 CMP(S,N)=333.19 w UNDER EX WALL 2-2" FIRE ALARM IE 18'CMP(S)=333.63 I 1 \ IE 18 CMP(S)=33236 CO SEE ELEC L FOR4 II CURBING w I IE 18 CMP(W)=332.06 2.5'x2.5' COMM CONDUIT D I I > I 0 � POTHOLE TO CONFIRM K4 m ? U I > \ I PULL VAULT 12 NC= 34.0 TRANSFORMER PER EX SEWER DEPTH BUILDING WATER LINE - w \ � ELEC'L. EXCAVATE ADJUST RIM TO \ I o � BEFORE BEGINNING NEW GRADE I \\I FOR 776-LA VAULT SEWER RE-ROUTE SEE C3.00 , I STORM DRAINAGE LINE - z /� CB R1M=338.77 (2) 1-1/2" CHILLED MEI ' R pN R IE 8'PVC(NW)=335.77 WATER PER MECH'L a 4" q L PAD I I SEE MECH L FOR CHILLER CONDUIT ° I TRASH I z VAULT I SSCO 4" PVC SIDE SEWER o VAU[r SANITARY SEWER LINE- ss 0/L/H20 \ I \ L POWER AND COMM PER IE=332.56 65 LF 0 1.0% MIN ENCLOSURE Q SEPARATOR i I I J CB RIM=3�3 \ ELEC'Ll COMM i F \ PER ARCH'L / POWER - E - II - 8""GONG=3 7 GD G D R 00 D GD ' �1D D EX CITY SEWER �' - TELEPHONE LINE T RD _ _ RD OVERHANG _ RD RD RD SSCO \ o w co ,zaa---_-__ El �n=CLINE \ GAS LINE - GAS - V GATE PER > SSCO 60 LF 6" DI FIRE SERVICE ° GAS LINE 4 PVC ® 1.0% (RECORD) ARCH' 1 EX CITY \ IE=331.00 wo VA EXPOSED I WATER MAIN WATER METER VALVE FH ® m \ N ' ss s ss ss s ss SS ss p / / ~ Ip'0 I IR I co 118 LF 6" DI FIR SERVICE J SSCO I I o O / PW 0 ASPHf Co �Ni�avd NV 3 I� 1 I STORM CB/MH ❑❑ ' � = O � n n _ - _ - _ - 8'PUC 33 CB R 39.15zg (l o r / RD - I / SANITARY SEWER MH/CO v OO • O - - EW)=339y25 RD 9 wo � � J WATER PER MECH'L // CL 0 a ❑� / � � GAS VALVE/METER ki � - - Z �I� 6 90 BEND (RJ) RECONNECT EX WATER FIRE SERVICE FOR K3 / I H 6 SIDE SEWER TO SERVICES FOR K4 GATE PER COORDINATE W _ STREET LIGHT ASSEMBLY I� ARCH L / a d � � � EX PRIV T� SEWER ' o � � 60 LF 3 TYPE KCOPPER -3� MECH L/PLUMBING � ° 1 z BUILDING FLOOR DRAINS SHALL I? ` DOMESTIC WATER SERVICE I o I TELEPHONE RISER/MH ■ OT / n / 1 K3 GAS SEE MECH'L/PLUMBING I I 1 DISCHARGE TO SEWER ONLY IQ H I / CONNECT NEW BUILDING �1 \ SSCO TO EX POWER COMM WATER METER FOR CONT N � "� a Wo VAULr `� IE=331.52 \ (FIRE AND DOMESTIC) ' CB Rl-338.84 ` \ °� - - - \ I 1 IE 6" (S)=337.54� \ lE 6P1(N)=336.84 IE 12 cr�vc(neEj 33a.99 I H d SPEED BUMP Z p 90 LF 3" DOMESTIC WATER SERVICE NEW K3 BUILDING PROVIDE HAND HOLE AT �, / Z `� b - \ IE 12 CoNc w)-J34�4 - - G; I A PER ARCHITECTURAL REMOVED LIGHT FIXTURE FOR CONDUIT TO REMA \ I a ( SEWER RECONNECT ICD SET TO FINISH GRADE2� _ NEW PLAZA 339.35f 3 1 CONC 9 EXISTING SEWER PIPE INSIDE SITE ®8 SEE ELEC'L Utility Notes: COORDINATE GAS RE -CONNECTION WITH MECHANICAL / PLUMBING DESIGN RE-ROUTE WATER INSIDE THE SITE TO SERVE EACH BUILDING WITH GEN ATOR I �� \ I I IS 4" AND 6" PVC PER N a 102 LF 6" DI FIRE SERVICE D ROUTE FLOOR DRAINS FROM I I RECORD DRAWINGS OF 1986 WO VAULTS al SERVICE AREAS THROUGH EX DOMESTIC WATER NOTE: EX SITE WATER (FIRE & DOMESTIC) SERVICES ALSO 6 PVC=336.7 I SITE OIL WATER SEPARATORS SERVICE FOR K3 ( I / n III Z 1 / COORDINATE W/ MECH L/PLUMBING I I CIO � PROVIDE WATER TO BUILDING L. COORDINATE SHUT �m N I I I I wl J RECONNECT EX WATER PRIOR TO DISCHARGE TO ) l / -� DOWNS OF WATER SERVICES WITH ALL CAMPUS USERS \ \ 1 Z I 1 _ a B SERVICES FOR K2 SANITARY SEWER. (TYP) \ \ / o� II III JI H �) RECONNECT EX WATER I I GAS LINE I ( SERVICES FOR K1 220 LF 3 TYPE K COPPER 231 LF 6 DI I \ CHANGES TO WATER SYSTEM TO BE I I( \ \ FF=339. EXPOSED TI T S V E E I \ I CONNECT TO - - �\DOM \ CB 1M=338.57 EX 2 WATER �\ COORDINATED WITH CLASS SCHEDULES AND I \\tire �' I n IIII I D iE 'PVC( 335. 021 CONNECT TO I� I OCCUR DURING SUMMER BREAKS. SYSTEMS SHALL I �ENUD RJ' - f2W �� I EX 8 WATERS I I BE FUNCTIONAL WHEN CLASSES ARE IN SESSION. _ � '\ I � / I 1111I111 h 11 I o - PPS/ OPWR P' 1 wo VAULr No PA J 1111 III/' I 4�0 53 LF 6 PVC SS ® 1.0% MIN IIII o° 6 PVAULT 5 BocrFD - - - - - n /ASPf SEE WATER AND SEWER NOTES ON C0.02 I I l� IIIIIIIII Ir\II,II a� D us END RJ / SEE WATER SERVICE DETAIL co (IIIIIII - III co CO, i s ( ) I PER 11 ;, SS SS SS SS SS SS SS SS / co c0 a pp =n= L �n n� Lw I- - - �a.�o SEE DETAILS ON C4.10 7- RD RD, RD RD RD COQ d / 'P. .C-T$ B�LIC \ IIIIIIIII / ASPHALr _ sNlNavd/�v �G 3ald /� \ Illll�llf' SPEED -BC/Mfi vl\IIIIIIi = u �, WATER SYSTEM CONFIRM INTERNAL FLOOR DRAINS ARE ROUTED �n G o cD r 3 z THROUGH OIL / WATER SEPARATORS AND TO SEWER \ IIIIIII / l SSCO TO GRADE (2) 1-11/4 CHILLED_3 1IIM l llll�� In L I FF=339.0 FF=339.0_i - - -� SYSTEM FOR DISCHARGE. SEE DETAIL 6 C4.10 GAS LINE WATER PER MECH L ¢ owl �111I1 (- I EXPOSED / / FIRFI=DEPAR E t0 ECTI C) IIIIIIh / POST INDICATOR (PIV) / - i�R&^UILDIN ON E IP �� IIIIIII I (IIIIIII w a PROVIDE ASPHALT PATCH OVER UTILITY TRENCHES L I / /� CB RIM=338. / K2 FOR BUILDING K 0 PIPE / / / CB R1M=339.33 (IIIII 8PVc=337. / BUILDINC / S PER DETAIL 8\C5.10 IE 8 PUC(S)=33573 IIIIIII / - - f1 111 DISCHARGE TBUILDING OO SEWEROR NONLYALL ) // N A'- POST INDICATOR VALVE PIV /lE 12 CONC(W)=33533 111 / I 11 COFOR BUILDING L ON E PIPE / / l�- - II / II I11 \ - - - - FIRE DEPARTMENT CON ECTION (FDC) - _ coNc � ��ass o PROVIDE TORZ �� W FOR BUILDING L ON EX PIPE / / ,I FIST ING I I CONSTRUCTION RECORD DRAWIN \ I I I \ ss s v9 LI __ 14 - - - s THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A y \ IIIIIIIII CONC WALL W/CLF _ OVERHANG T DDi16�E�UC„ R _ � - - - - --_ _ __ H K-VALVE ON EXI FIRE c E ITED TO CAD FILE PREPARED BREFLOECTHFIELD PORTER VER VERIFIED (INVERT AND ------ -- - -------346- � --- - - _ � - - - ------�4�- -------------34s-- -� �FRVIEE: CO RDIN�T rIL(j) �� - -- \ HAS BEEN ---- ---------- _--------34�- _ _ __ _ _ - _8 IONS OF THE STORM, SANITARY SEWER AND I I 1 �--------- - (2}BDN�- ----- - NVERT AND RIM ------------ _-------- ----- ---------1�2G0A5-MEfiE1� F E�tL�(RMS Cj or INSTALL EDU D PRESSURE` RIM ELEVAT---- -- -------- ----rr---------- -- CB F1M=35269 I rg - - - _ 358-- - - - -- - - - - - 358- -- - - - - - -� -350-- - -6'c - � _ _ _ _ �o _ - -�" - f �-o BACKFLO SEMBLY ON EX CE&C CONSTRUCTION z IE6PUC(E)=350.59/ ---------------------------------------------------_-_-_-_-_-_-_-_--___ _--- _______----- DOMESTIC SSEMBLY WITH IN MARCH 2O17 LJ o ------------------------- --------------------------------�B-R�,t�3583�---- ------------------ ()- - HOT BO AND POWER. OR COMPLETENESS N a / \ C - - �- - - - - - - - - - - - - _ 9 H - 49.78 COUGHLIN PORTER LUNDEEN INC. DOES NOT PROVIDE ANY OF -3b4----------------------- 354------------ _----�54------ -- -- ------ ---------_� CL PROVE POWER TO HOT I / -\ o / - - - - - - - - --__________________ - - - - - -/ �(CF�F �L�4---- -- _ �r\ -_��� - ��\ CL CHAN BP\t/C(W)=338.68 / WARRANTEE AS TO THE ACCURACY ` I '¢� 8'oEc _ _ _ _ _ - - - - _ _ - L - - _ _ - \ ' BOA C SEA DETAIL 87,E SUCH INFORMATION PROVIDED BY OTHERS. I ~ - _ -_-- --- ------------- -� -- - \ \ B:DEC \ N L C�i -358---------------------- ___ --7f Pli--j5620 GRASS � / �`---��------�)-- \� r--- �\ �\ � �� \ �� � ��� '� ."BRASS ��'�369� __�� _---\�--- - ` � �6g _ �\\ *6,UPERMIT# U15000494 \ �� 1 % ��\ �� 1 � ����_IARB�-�y' wrv� vvnLn CONC WA+K 1 1 / CONC WALK I I I / 1ONC WALK \ vM?,- - - - - - -- ---- ---� - --- -- Approved By: Date: SV9 a UM U R r R LIMIT LIMIT OMIT T OMIT \ MITT T UMR9� I7/M�10 o / 7 77- [i� \ \ IE 6'P�C(NE)=349.82 'ON4LT DRIVE �� CTil �' ASPHALT DRIVE lE 8'PUC(SE)=349iS2 LIMITS OF WORK PROVIDE STORZ FITTING \ IE 8'PVC(S)=349.52 \ w / / Approved By: Date: z w z EX CITY WATER MAIN \ / �N EX FIRE HYDRANT (TYf� �, \ \ IE 12PVc(NW)=347.02 W PROVIDE STORZ FITTING / W w w w �\ w w �e w w o �w w w w /, - �6FlR �� - / / ON EX FIRE HYDRANT (TYPY - ` -0 \_ - - \ - �� v _ = Approved By: Date: Lam- 9-- ---- 362- CURB 3�C------ S �� i - --- -- -- - CWA�`� - L J ,CON // Approved By: Date: A. Jq C _ NOTED CITY OF AUTOMOTIVE TRAINING CENTER / / OF WA S� O SURVEYED: SCALE: AS HORIONiAL: NAD 1983/1991 �► 04 30 201 5 COVGHLIN PORTERLUNDEEN DESIGNED: RENTON TECHNICAL COLLEGE FlELDBOOK: ti A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION DRAWN: RENTON PAGE: 801 SECOND AVENUE -SUITE 900 P: 206/343-0460 LBJ ONE INCH RENTON WASHINGTON DRAWING NO: DATU M 43667 CIs V,�` SEATTLE,WA 98104 F:206/343-5691 CHECKED: AJ IF NOT AT FULL SCALE Planning/Building/Public Works Dept. C,4°00 sSI�NA1L y�v� /�� N Q APPROVED: SCALE ACCORDINGLY UTILITY PLAN SHEET: 9 OF:1 Z REVISION BY DATE APPR J W- 1 1 R-381809 S/ 38 80 PRECAST CONCRETE VAULT WITH 3 — Nx 3' ONE EACH SIDE 4"x 2 1/2" FIRE DEPARTMENT DOUBLE HINGED STEEL PLATE COVERS. ❑II+rENSI0r45 CONNECTION FOR STAND PIPE WITH 5`-S'x Si'-2"x 7'-2" EQUAL TO UTILITY 4" ADAPTER, FL.x SCREWED BREAKABLE CAST 3RON HOSE CABS. FAULT OR EQUAL +4"x+4"x5" Bi1LL HEAD TEE, FL. ONE EACH SIDE EWAL TO GRINNEL FIG, 1682 WITH HOSE CAPS FIG. 1333 L,i 120 VOLT ELECTRICAL OUTLET FOR TOUCH READ PIT FIL I_A7ESENSDR z HEAT TAPE_ INSTALL NEAT TAPE PROPERTY LINE CCIVFRED 4N STEEL PLATE 6•' PIPE FLx 6" IS NG TYPE GRAVITY OPERATED J FOR FREEZE PROTECTION RECESSED COVER THROUGH 2" DIA. CHECK VALVE, FL. EQUAL TO d �31LIFT POCKET DRILLED MOII IN COVER. FL 2'-U" LID CENTER BACKFL4W MUELLER CO. WITH BALL I cr PREVENTER IN FUTURE THE BY-PASS ASSEMOLT SHALL BE DRIP VALVE ATT BOTTOM Ad LJ 6" BUILDING SEWER PIPE UUILOING SEWER nJCLUUED AS PART 4F THE DETECTOR INSTALL EPDXY NON -SHRINK 0 � REDUCED PRESSUR€ ENCL{]SUF�1= ' } - 11 N.C.SOCKET HD 2'-D" OOUBLE CHECK VALVE {ASSEN1bLY. 18" FOR 10" ASSEMBLY GROUT (TYP- r BACKFLOW ASSEMBLY �" 2" A.C. ) � S/8"x3/4" SENSUS SRII (TR/PL) METER 17 1 �2" FOR s" ASSEMBLY = � SCREW 1 }atl LONG 3 _a 6" PIPE, FL,x Fi 3'O" LONG f� o WITH ICE REGISTER- 1s 1/2" FOR 8" ASSEMBLY 0 (RPBA} �" MIN. a (BROhi E OR S.S.) } \6"& 8' ASSEMBLY. B' SHORE p 2"x 4" STUD MARKING POST PAINTED { 4 CITY eWA1E I'll 7. TEE WITH 6" SIDE OUTLET J 8 x6 X6 WYf WHITE WITH THE WORD "SEWER" STENCILED SURFACE CLEANOUT WITH � CAST IRON RING & COR IN 3" HIGH BLACK LETTERS AND #6 WIRE � � V 2" RAISED PADS = PIi�t1c PANGVE W WRAPPED AROUND THE STUD AND (EAST JORDAN IRON WORKS x TEE JUJ x FL) q EXTENDED TO THE TAP OF THE STUD- 2975 DR APPROVED EQUAL, CL "SEWER" 1— _ . GATE VALVE(FL x ASS) SPECIFY OR LID, � f 6" SIDE SEWER, AND BUILDING SEWER SEE SM. PLAN 403,1 FOR INSTALLATION) fi' CONCRETE�- M.L�k CITY PiAIl CLASS 3000 SAND OR —To 12' ALL AROUNDFOAMLINES ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAINEXPANDABLE ARE AS FOLLOWS CONCRETE $LOCK ING RADAIS 90 BEND FL. 10" ASSEMBLY 90' a"xB" INSULATED ENCLOSURE REDUCING SEND fL. 3" MIN- 3" MIN, "HOT BOX" OR EQUAL .3/8" X 4" ANCHOR : TO BUILDIN 1 BOLTS PER f MANUFACTURER DEADMAN eLocK 3" MIN- REOUIRED CONCRETE SLAB z UNION FINISHER A. VITRIFIED CLAY MAIN -- CUT IN A NEW SECTION OF SEWER MAIN WIT} i2 74 1❑-,a",a- FL x MJ ADAPTOF. A NEW TEE USING FLEXIBLE COUAUNGS WATER TIGHT ALL DETECTOR DOUBLE CHECK VALVE GRADE i4LIJG ASSEMBLIES SHALL INCLUDE RESILIENT cv W (FERNCO OR APPROVED EQUAL)- 10", 8" 4R 6" FL.x P.E. qq FINISHER COCKS. SHUTOFF VALVES AND TEST PLAN 10' ASSEMBLY "x8"y8` TEE, FL L PIPE WFTH COLLAR 18" GRADE r 13 CONCRETE MAIN - CUT IN A NEW SECTION OF SEWER MAIN WITH FROM P.E. CROSS -COCKS. .4N0 APPROVED Al ASSEMBLY B"x8"x6" TEE. FL. 6" z A NEW TEE USING FLEXIBLE COUPLINGS 2- ASSEMB ES ECTIarI CONTROL ASSEMBLY 6'xC-xC" TEE, FL }fg" 14"- 3'-9" LONG' ASSEMHUES PER DEPARTMENT OF w (FERNCQ OR APPROVED EQUAL). - 45- (T/8) BEND 8 3'-5- LONG HEALTH LATEST APPROVED LIST. 14", 8", OR fi"' GATE VALVE, FL,x Md. ' fi"- 4'-0" LUNG WITH INDICATOR POST. INDICATOR U JPV C. PVC MAIN -CORE-DRILLED WITH A ROMAC SADDLE (OR APPROVED i 2^ I4ICLUDESTWO H -RESILIENT VALVL Ss£aTED CHECK VALVEVALVE SA(EfLLETaME SIZE ASD ON LE WV F1 Vp DRAIN EQUAL) OR CUT IN A NEW TEE USING RIGID COUPLING`-. 1 y" �`¢"= SHUTOFF VALVES. ' R C4, E4LIAL), PAINTED fIEO. ¢ z SEA NOTE ¢ V D. DUCTILE IRON MAIN — CORE —DRILLED WITH A ROMAC SADDLE (OR g" 10'. S', OR 6" FLANGED COUPLING fi'� MINIMUM � m SLEEVE Z APPROVED EQUAL i 4" ! C� ADAPTER EQUAL TO ROMAC- 1Q", B" OR fi" DLICTII E IRON FREE DRAINING m (TYP. E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE 1 CLASS 52 14IPPLE PIPE. GRAVEL � z AT MANUFACTURED KNOCK -OUTS OR THE �G CEMENT LINED, LENGTH T4 FIT. STRUCTURE SHALL BE CORE -DRILLED. Q i 1 TOUCH READ PIT LID SENSOR MOUNTED CONNECT TQ 50" ALLOWABLE MAX- 12 Y•" A1ON STEEL PLATE COWER THROUGH 2" DIA, WATER METER FOR CAST IRON PIPE I&" '�1 N01L DRILLED HOLE IN COVER- IMMEDIATELY S, 36"TO4' ADJACENT TO DR DUCTILE IRON PIPE. LOCATE VAULT IN PLANTING AREA, NOT IN RAVfNG f�PQA �S D13 w 1:3:5 MIX �`� �� �� OAST IRON RING AND COVER ��' PIPE MATERIAL AS SPEGIF'sLl! 2. +4" AND LARGER SENDS AND TEES TO BE CAST i FL xIPSCR+WJ — CONCRETE apG c�`�` BY THE ENGINEER IRON CEMENT LINED. 16" FOR ifl' ASSEMBLY 17 BLOC141NG 'L �}P 1/2- FOR s' ASSEMBLY 18 FLOW � TEMPORARY SUPPORT SHALL BE PROVIDED UNDER 1/2- FOR 6" ASSEMBLY 2 Ws» 3 INSTALLED W% APP-D. O p 2% MIN SLOPE VALVES AT THE TlVE OF INSTALLATION TO CENTER TO OWNERS ELECTRICAL PANEL, FRONT VIEW _ 7HE PIPE IN VAULT OPEMNG. AFTER COMPLETE MATERIAL PER UPC s/5"x3/4' INVENSvs DIRECT BURIAL OR IN RIGID METER SIDE HORIZONTAL INSTALLATION REMOVE THE TEMPORARY SUPPORT iR—PL METER WwTH 7-2- (SIZE AS REQ-} CONDUIT PER ELECTRICAL 6" SIDE OUTLET TEE ANO INSTALL ADJUSTABLE PIPE SUPPORT. ICE REGISTER �. SIDE I EW PERMIT R'EQUIREMENTS- OSEWER 4. INSTALL GALVANIZED LADDER FOR ACCESS. 6" MIN. DRAIN TO DAYLIGHT OR ,\ fi" MIN- MAIN SEWER MAIN STORM DRAIN SYSTEM WITH 6" so' SEND FL NOTES- 5. AFTER FIELD INSTALLATION, MAIN I)DCVA AND CATCH BASIN OR MANHOLE-`,2'-1T" 1. ALL REDUCED PRESSURE BACKFLOW ASSEMBLIES (RPBA's) MUST BE LISTED Oink LATEST LIST OF ` ACKFLOW 45' (1/8) BEND BY-PASS DCVA MUST BE TESTED SATISFACTORILY PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATEI", PUBLISHED BY STATE Or C.QN.CR.ETE BLOCKING, ANGLE QY A DEPT- OF HEALTH CERTIFIED BACKFLOW GALVANIZED TYPICAL_ SDE-SEWER -ELEVATION ASSEMBLY TESTER, TEST REPORT TO BE SUBMITTED STEEL LADDER WASHING70N DEPARTMENT Cr HEALTH. OF TEE AT MAIN OVER ?5 TO CITY OF RENTON WATER UTILITY ENVINEERING 2. THE OY1+1VERfAPPIICANT MUST OBTAIN A SEPAf ATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION ELEVATION DEPT. PRIOR TO AC1]VAYION OF NEW LINE COMPACTED FQUfEpATlOhe OF THE INSTALLATION OF THE RPRA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE RPRA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. hl07ES: S. INSTALL BRASS Y¢" FLARE TEST COCI4S WITH 04�AVEL FLARE CAPS ADJlI5TAF3LE STEEL PIPE SUPPORT, 3. THE RPRA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL NOTE: 1- 8" AND 6" C'IEANIOUTS ON SEWER MAINS SHALL RF EAST UDRDAN IRON WQRI{S, INC- STANCHIONS ROLTED To FLOOR. INSTALLATION, AF rER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST No. 3698 OR EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE END VIEW UTILITY CROSS -CONNECTION CONTROL SPECIALSIT, FAX NO. 425-430-7241. A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER' 2- IN kJNIMPROVED AREAS, POUR A 1'-O" THICK, 2'-U- SQUARE 4. DRAIN SHALL BE SIZED IN ACCORDANCE WITH AWWA CROSS CONNECTION CONTROL MANUAL STANDARDS THAN THE LOWEST HOUSE ELEVIATION, WHICHEVER IS LOWER. CONCRETE. CLASS 3000, PAD AROUND THE RING ,ANU CDVER. 3" DRAIN FOUR 1" OR SMALLER RPBA's, 4" DRAIN FOR 1.5' TO 2" RPBA's" 6" FOR 3" RPBA's, 5_ RPBA AND ENCLOSURE SHALL BE LOCATE[ ON PRIVATE PROPERTY AND AS NEAR. A5 POSSIBLE TO THE WATER METER. PUB11C WORKS 8 OR 6 INCH CLEAN -OUT STD. PLAN — 403.1 c; STANDARD SIDE SEINER STD. PLAN -- 406.1 +' + 6" 8" & 10" DOUBLE DETECTOR CHECK STD. PLAN — 980.E S'I'I}. PLAN — 350.E PUBLIC WORDS 4 DEPARTMENT FOR SANITARY SEWER MAINS PUBLIC WORKS PUBLIC WORKS REDUCED PRESSURI= BACKFLI IN INSTALLATION - SEPTEMBER 2011 + + ASSEMBLY WITH STANDPIPE OUTSIDE + + * � r DEPARTMENT Y .. DEPARTMENT ., DEPARTMENT ASSEMBLY IN 1—ICT BQ}{ `N e o (SEWER MAIN TO PROPERTY LINE) JANUARY 2013 INSTALLATION MARCH 2O10 MARCH 2010 NTS NTS NTS NTS Standard Side Sewer Installation 5 SanitarySewer Cleanout 8" DDCVA in Vault 7 Reduced Pressure Back Flow Assembly in Hot Box y FIRE DEPARTMENT CONNECTION (FDC) FOR BUILDING K ON EX PIPE (2) 45° BENDS (MJ) 8" PE TO FIT 8"x6" REDUCER 1 W/THRUST BLOCKING 8" SPOOL VERIFY EXISTING CONDITIONS AND PIPE SIZES BEFORE ORDERING PARTS AND BEGINNING INSTALLATION POST INDICATOR VALVE (PIV) - ------ FOR BUILDING K ON EX PIPE ----------------------- 5 nn -- POST INDICATOR VALVE (PTV) -------------------- FOR BUILDING L ON EX PIPE CONTRACTOR SHALL VERIFY I THE VAULT SIZE REQUIRED TO ACCOMMODATE ALL REQUIRED PIPES VALVES AND FITTINGS INSTALL DOABLE DETECTOR PRIOR TO ORDERING VAULT FIRE DEPARTMENT CHECK VALVE ON EX 8" FIRE EX 8" DI TO BUILDING L CONNECTION (FDC) SERVICE. COORDINATE WITHFIRE ALARMS, SEE DETAIL 7 FOR BUILDING L ON EX PIPE INSTALL REDUCED PRESSURE BACKROW ASSEMBLY ON EX DOMESTIC ASSEMBLY WITH uj PHOT BOX AND ROVIDE POWER POWER. 0 P E R M IT# U 15000494 TO BOX COVER SEE DET 'IL 8 co c1�1 Approved By: Date: NTS EX 2" D MESTIC METE Scale 1 =5 Approved By: Date: � Not Used 9 W W W W Water Service Detail Approved By. Date. Approved By: Date: A. JAC' As NOTED .. CITY OF AUTOMOTIVE TRAINING CENTER / / Y OF WASH O SURVEYED: SCALE: HORZONTAL:�NAD 1983/1991 �► 04 30 2�� 5 COUGHLIN PORTERLUNDEEN DESIGNED: RENTON TECHNICAL COLLEGE PAGE: OK: A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION DRAWN: LBJ RENTON RENTON WASHINGTON PAGE: 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 ONE INCH DATUM DRAWING N0: 43667 SEATTLE, WA 98104 F: 206/343-5691 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. C4, 1 0 JAJ NAL E��N0. REVISION BY DATE APPR SCAEOACCORONGLY UTILITY DETAILS APPROVED: SHEET: � O OF:1 Z S/W-381802 R-38181 0 �1�iA�IZIf� '�1 � i 1�1II�►� 1 '`I���li ��s�i��I•� I NO2705 W 828.22' — — — — — — — — — — — — — — — — — — — — — — — — Call before you SDMH R1M=342.60 sSMH R1M-338.84 EXTEND EX ROCKERY ALONG 0.F 339.30 D j g. 8-1-1 1 , �a CHAN 8'CONC(N,S)=32769 SIDE WIDER PORTION OF lE 78'CMP(S)=33550 SS/AH '' or 1-800-424-5555 Kl R KLA ND A VENUE N. E CL CHA,, 98 POROUS CONCRETE WALK 7<j UNDERGROUND o CB R1M=337 82 r r-,� SERVICE (USA) 0 10 20 40 4'MAP E 4'NAPLE 4'M PLE '1AAP17 SCALE 1"=20' 4'�A4PLE — — — — 76 20 P/NL�� ASPHALT LEGEND DRIVEW414E�mm*�jj*n—>t4- � n r� wn =� i�wn n� � n awn awn � 3 2 S MATCH EX I 6' cHA1NLINK cHA/NUNK � I EXISTING PROPOSED CURB REMOVE TEMPORARY PATCH WALL 0 INSTALL POROUS PAVEMENT - L J L _,'------------------- ASPHALT PAVING .. .. L J� _ llnn — IN SEQUENCE 2 r re- CONCRETE PAVING 0 co OVERHANG ,''. .r. . D 'a,' o. 20 F pp'r6''�, a, r r.r.-� r^' .r' '. r rr'r r.r 16 L r r. r.. °r �� r r r .,Q--• 'r r r, r.-�. °--6--•..r 'mod - RECORD �� POROUS ��•r'�: r� .r. i 6"-328.39 r r. r GATE CONCRETE PAVING LU ESTORE VERTICAL '2p' a' I--- CURB PER r r POROUS CONCRETE WALK L SDMHnR1M-342. , 83 10" MATCH EX c�2o � r �.. � PER(a) e BUILDINGS �� 8 CURB WALL w ELEVATIONS r r r WHEEL STOP (TYP) O e .. L c o . . EQUIPMENT PADS GRIND AND OVERLAY PER 12 PER 10 GRAVEL ADJUST LIDS U I RECONFIGURE POROUS CONC. WALK 6" CONCRETE SLAB PER AND CASTINGS PER c` o CONSTRUCTION LIMITS UMIT �r _ AND ROCKERY TO ACCOMMODATE . COORD W/POWER, COMM A NOTE: ADD NEW ASPHALT AT TO GRADE (TYP) 5.0 CONCRETE WALK O LOCATION OF GAS METER ASSEMBLY AND CHILLER INSTALLATIONS GRIND & OVERLAY AREA AS ROCKERY C7t z � _ cR R[1 - . PER 10 RAISE GRATE AND '�^ WHEEL STOP NECESSARY TO DRAIN TO EX NOTE: AREA BETWEEN c5.�a O o CHANGE TO BE q@ TRENCH DRAINS AND TO FLUSH GRIND AND OVERLAY SIDEWALKS SLOPES TO TREE z VERTICAL CURB r 7.5' POROUS CONCRETE PER 12 (TYP) ASPHALT PAVING � EX TRENCH DRAIN J PER 6 OUT WITH CONCRETE WALK PER 2 ADA COMPATIBLE Q (TYP) PAVING PER 10 C5.10 PER C5.20 CURBING c�2o] c� o J c .�a GD G�: D R cD c ° ° TRASH 6P'�R CURBEl WATER METER/VALVE/FH 63 D4 PATCH 6" CONC SLAB C 200 W R=43' SEE LANDSCAPE n ASPHAL SIMILAR TO STORM CB/MH ❑❑ ❑ FOR PLANTINGS I ;I, 0 cC5.100 > SANITARY SEWER MH/CO OO 0 694 SF L J L J O 0'0,r ONIHaVd ON 3N Id, o GAS VALVE/METER D4 0 75 >e s cIJ •^ .-v. ev. s o ,o "v -v' _ _ ' v v. .s; v�- .v v O I STREET LIGHT ASSEMBLY 339.50 PLANTER PER BEGIN VERTICAL TELEPHONE RISER/MH ■ OT r Z ASPHALT SPEED BUMP END CURB L SCAPE 1 v CURB PER 20 Q e / a PER11 E NEW PAINTED o C5.20 N z �i WHEEL STOP TYP CROSSWALK ^ w CONCRETE � (TYP) WHEEL STOP ENTRY PER 12 LU PER 12 (TYP) R=49' LL �10 \ ADJUST LIDS ADJUST ROCKERY AND CASTINGS 19 SEE 6 �¢ �'��� as—� FOR NEW BLDG TO GRADE (TYP) FOR C1-0 N PROTECT EX ASPHALT SPEED BUMP O PER11 DETAILED GRADING ROCKERY ALT 2 c 2�0 END CURB 3 / � � I SEE LANDSCAPE SEE CI l o FIRE LANE � CONCRETE WALK 20 FOR PLANTINGS ? MARKINGS PER ( J 1 (TYP) PER 10 PERTORASPHALT m a c� o I C� c�52�o Z Z ASPHALT PAVING R ASP R=43 m a PER(j) ASPHALT SPEED BUMP \\ PER CI .' z O J cC5 o PER 11 GA5 LUVL C5.20 z a EXPOSED - e F. IRE w - o - F LANE NO PARKING C L J I 00 0 � co 0 0 J o PLANTER PER OLLED CURB o L'SCAPE ER� 1 n=ter TRANSITION CURB \ C 0 ERHANG ONIN21Vd ON,- 3N4-1 38I1 PER 0 ASPHAL T v EL it RUM G GC r' n GRIND AND OVERLAY =- ' GRIND AND OVERLAY PER ADJUST LIDS PER(a:) C5.20 05.2o MONOLITHIC # !_ AND CASTINGS CONCRETE WALK . - L J I TO GRADE (TYP) PER 3 -- 339.33 0� 0 IL � � ;C'(S)-33573 MATCH EX CURB c 72"coNc w-335.33 w ® AND WALK ��- PROTECT EX � CONCRETE RESTORE LANDSCAPING T- 3; �� / PER L'SCAPE FROM 2'-6" HIGH ROCKERY CURB PER 1 � ; o - G BRIDGE REMOVAL I CONSTRUCTION RECORD DRAWING o != THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A ,T I � oRERHANc CAD FILE PREPARED BY COUGHLIN PORTER LUNDEEN AND � HAS BEEN EDITED TO REFLECT FIELD VERIFIED INVERT AND I silly )78 i�l [SLR C RIM ELEVATIONS OF THE STORM, SANITARY SEWER AND [R V 8'F1R 8'oEC LIMITS OF WORK WATER MAIN SYSTEMS. FIELD VERIFIED INVERT AND RIM R CE&C CONSTRUCTION IN r , MARCH LIMITS OF WORK COUGHLIN PORTER LUNDEEN INC.DOES NOT PROVIDE ANY L J CB R1M=358.38 CL CHAN 8 FAC(E)=340.08 WARRANTEE AS TO THE ACCURACY OR COMPLETENESS OF I ROLLED CURB e 7E 8 PLC(SE)=356.78 CL CHAN 8 PI/C(W)=338.6 LE 8'PVC(N)=35578 SUCH INFORMATION PROVIDED BY OTHERS - LE 8'PLC(F)-35620 8'DEC MAINTAIN MIN 4-FOOT 0 J� RFD. MARBI RQ< ' RB[ CONCRETE LANDING U P E R M IT# U 15000494 \ PER �� MATCH EX BEHIND CURB RAMP fin\ Vim' ` � R LVIVI� VVHLII ' �g CONC WALK Approved B: Date: — — UMIT — — UMIT E - — UMIT — — UMIT — — — UMIT — ---LuMlf` UMn — — — — OMIT — — UMR p provey CURB TRANSITION a 349.82 �� _ lE 8'PI/C(SE)=349.62 RESET STOP SIGN LIMITS OF WORK lE 8'Puc(s)=349.52 Approved By: Date: TYPE 2 CURB RAMP � W/DETECTABLE WARNINT""""""" ROLLED CURB F 72'PAc(Nw)=34i PER 7 PER 5 Approved By: Date: cog C� o - cotiG Approved By: Date: LV VERTICAL- It7 AS NOTED .. CITY OF AUTOMOTIVE TRAINING CENTER / / OF WA $� O SURVEYED: SCALE: HORIZONTAL: NAD 1983/1991 �► 04 30 20 1 5 W �1 - `� COUGHLIN PORTERLUNDEEN DESIGNED: RENTON TECHNICAL COLLEGE FIELDBOOK: ti A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION DRAWN: RENTON PAGE: LBJ RENTON WASHINGTON DRAWING NO: 801 SECOND AVENUE -SUITE 900 P: 206/343-0460 ONE INCH DATU M 43667 �` SEATTLE, WA 98104 F:206/343-5691 CHECKED: AT FULL SCALE Planning/Building/Public Works Dept. C,5.00 sSI�NAL y�v� IF NOT ONE INCH N Q APPROVED: SCALE ACCORDINGLY PAVING PLAN SHEET: 1 1 OF: 1 Z REVISION BY DATE APPR I J R-381811 12" R R TIC 339.35 ° BC 339.00 FLOW LINE I TIC 340.00 _ BC 339.50 13" R , 1/2» R ° R=24.5 FIRE LANE MARKINGS SHALL CONSIST OF: GENERAL ASPHALT PAVING NOTES: 9 339.50 ° ° 1. RED PAINTED CURB WHERE CURB IS PRESENT. 1. SPECIFICATIONS FOR ALL ASPHALT CONCRETE WORK SHALL BE PER THE LATEST EDITION IN EFFECT OF ° 1 R-1' - THE WASHINGTON STATE DEPT. OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND o i \ 2. RED STRIPE 4" WIDE ON PAVEMENT WHERE NO CURB IS PRESENT. MUNICIPAL CONSTRUCTION." ° o Cn f ° ° „ 3. BLOCK LETTERS STATING FIRE LANE - NO PARKING 18 TALL WITH 3 BRUSH STROKE PAINTED WHITE 2. ALL ASPHALT CONCRETE PAVEMENT SHALL BE PLACED IN ACCORDANCE WITH WSDOT/APWA SECTION 5-04, 339.35 16 TC 340.75 APPROXIMATELY 12 FROM FACE OF CURB OR LANE EDGE AT 50 INTERVALS. UNLESS OTHERWISE SPECIFICALLY NOTED. 1 o BC 340.25 3. PROOF ROLL AND REMOVE ANY SOFT SPOTS. REPLACE REMOVED MATERIAL WITH STRUCTURAL FILL PER THE GEOTECHNICAL ENGINEER. CONTRACTOR SHALL TEST AND VERIFY SUBGRADE MEETS COMPACTION REQUIREMENTS o' PRIOR TO PAVING. 4. CRUSHED SURFACING SHALL BE PLACED IN ACCORDANCE WITH WSDOT/APWA SECTION 4-04, AND SHALL MEET � 6" 12" THE REQUIREMENTS OF WSDOT/APWA SECTION 9-03.9(3). 1'-6" 'B' z 5. AGGREGATE SHALL BE CLASS 1/2" MAX MEDIUM GRADING CONFORMING TO SECTION 9-03.8 OF WSDOT/APWA. w ASPHALT BINDER SHALL BE ASPHALT PAVING GRADE AR-4000 AND SHALL COMPLY WITH WSDOT/APWA 9-02.1. U ASPHALT MIXING AND PROPORTIONING SHALL COMPLY WITH WSDOT/APWA 9-03.8. 4" 339.30 (D 6. SAWCUT FULL DEPTH WHERE NEW PAVEMENT ABUTS EXISTING AND APPLY TACK COAT. Z18y LO Z y 339.45 Q 00 NTS NTS W ,/ 339.69 Fire Lane Markings 3 Paving Notes > z Q / 339.30 z CO O ROLLED CURB #3'S AT 12" O.C. 73 PER PLAN 339.50 339.33 339.69 FFE EACH WAY (TYP) CONCRETE SLAB ° 12" MIN SAWCUT, TACK AND MATCH 20' MIN a 2" MIN , FINISHED GRADE EX ASPHALT FULL DEPTH _ • ° 0 o o 6 a ° as ° \\IF R=2 21 S' 00 00 00 00 00 00 0 00 00 0o ao 00 0o ao 000 oo�oo oo�oo oo�oo oo�oo oo�oo 0 00 00�00 00�00 00�00 00000 00000 00000 00000 0 cbo 000 000 000 00 0°00 o�Do o�DO ooDo Do o�Do o� 4.0% TIC 340.33ooC°`�oo�°`�oo�°`�oo�° o 0 oocbo oocbo oocbo oocbo oocbo 00 o Do o Do o Do o Do 0 00 0 oocbo D D D D D D 4�(� 4� l� 4�C� 4� BC 340.00 000��000 ��000 �a000 �a0000�80000�8 00��000 ��0000��0000�a0000�80000�80000�S0000�8 �r oc�0000�0000�0000�o�ooc�o�oocboo cbo�oo�0000cbooDocbooDoc�ooDoc�0000c� jooDoc�oo Cao4��a \/i\/i\ \/i\/i\/i\/i\/i\/i\/i\/i /\/% - - - /✓i✓✓i //, �/, // /% r /i //� /, = - - - - VERTICAL CURB NOTES EX OR NEW PER PLAN 45 \\\\\i\\\�\. \/\�\\�\��/, CRUSHED SURFACING BASE -COURSE COMPACT TO 95% MAX DENSITY = -=- =//\\//` \/\\ EXISTING ASPHALT 1. FORMS SHALL BE TRUE TO LINE AND GRADE AND SECURELY STAKED. I 1 \ , SCARIFY AND RECOMPACT TOP 6" OF 1 I _ \/\/\ EX UNDISTURBED PAVEMENT =11=11=11=I I=11=11 11=I I=1=11 I I=11 11=I I=11= I // //, - - - - - - \\\\\\� SUB -BASE MUST BE I / - ` EXISTING SOIL TO 95% MAX DENSITY =III 1 1 1 1 1 I 1 I I\\\/�\\/�` COMPACTED TO 95% MAX. / / 2. THRU JOINTS SHALL BE PLACED ADJACENT TO CATCH BASINS, INLETS, CURB RETURNS, ALLEYS, OR A MAXIMUM SPACING OF 10 FEET. TIC 340.50 (SOILS ENGINEER TO APPROVE EX SUB- - _ - _ _ _ - = _ - _ - _ \\,//� DENSITY PER ASTM D 1557 BC 340.17 5 7% � GRADE PRIOR TO PLACEMENT OF CONIC) „ „ 3 CLASS B ASPHALT CONCRETE PAVEMENT 3. THRU JOINTS SHALL BE 1/2" WIDE PRE -MOLDED JOINT FILLER. NOTES: "' 1. PROVIDE CONSTRUCTION OR CONTRACTION JOINTS PER DETAIL 9 \�/i /j\�/j// 2 CRUSHED SURFACE TOP COURSE 4. ALL JOINTS SHALL BE CLEANED AND EDGED. LIGH�IPOLE� COMPACT TO 95% MAX DENSITY SUBGRADE 5. CONCRETE SHALL BE CEMENT CONCRETE CLASS 4000. dLEC'L N 2. COORDINATE BLOCK OUTS WITH EQUIPMENT. 4" CRUSHED SURFACE BASE COURSE 6. STEEL FORMS ONLY MAY BE USED ON TANGENT SECTIONS, WOOD FORMS MAY BE USED ON CURVED SECTIONS. 50 33 . S E L'SCAPE FOR R=2.5' CORING LAYOUT 3. MIN CLASS 3000 AIR -ENTRAINED CONCRETE. COMPACT TO 95% MAX DENSITY - 12" (MIN) STRUCTURAL FILL AS REQUIRED OR 7. FINISH SHALL BE LIGHT BROOM. EXISTING SUBGRADE COMPACTED TO 95% MAX. DENSITY PER ASTM D 1557 8. THE FINISHED CONCRETE SHALL BE COVERED BY CURING COMPOUND, WATERPROOF PAPER OR PLASTIC , - TIC 340.83 20 SHEETING IN THE EVENT OF RAIN OR OTHER INCLEMENT WEATHER. CURING TIME SHALL BE AS SPECIFIED. BC 340.50 AZI NTS Rolled Curb and Gutter 5 Grading 6 gp Reinforced Concrete Equipment Pad 7 As halt Concrete Paving g EXISTING SLAB, 3/8" WIDE x 1/4" DEPTH NEW POUR SITE OR BUILDING BEAD OF ELASTOMERIC SEALANT FINISH PER L'SCAPE CONCRETE SLAB _..: . ,. ° 3/8" FIBER EXPANSION JOINT ° CONCRETE, SEE DETAIL 10\C5.10 Q O Q O a ° 4. ° a - CONCRETE WHEEL STOP W/ (1) NO. 4 BAR (EACH END) 0000 00�00 00�00 00�00 00�00 00�00 000 00000 00000 00�00 00�00 00�00 00�0o COMPACTED CRUSHED ROCK ooq�o Doq�o Doq�o Doq�o ooq�o ooq� Doq�o Doq�o ooq�o oOcbo oOcbo oOcbo oocb oq�o D ���oaoo�aoaoo�aoaoo�aoaoo�goaoo�g000�g0000�aoo0o�ao°0o��0000��0000��o°0o�go°0o�8o°0c SEE DETAIL 10\C5.10 a ° a a a a e ° ° a ° °°° 4 " APPLY EPDXY RESIN TO 000°000°000°000°000° o° 000° boo°o° boo°o° boo°o°moo°o°moo°o°moo°o°`boon°`C 0000�80000�80000�80000�80000�8 00�80000�80000�80000�80000�80000�80000�80000�80000�80 ° e ° ° a � a °, � \\ \ CONTACT SURFACES PAVING SEE DETAIL 10\C5.10 000 OooO OooO OooO DooO OooO o0 OooO OooO OooO OooO �000 OooO OooO 00�0000q�0000�0000�0000�0000�oo �0000�0000�ooDo�ooDo�ooDo�0000�0000q�oo � /\ \ \ i///////// EXPANSION JOINT CAP EXPANSION JOINT ��goo0o��oo0o�aoo0o�aoo0o�aoo0o��000 goo0o��0000��oo0o�aoo0o�aoo0o�aoo0o�goo0o�goo0 / \\ \\ \\ \\ \\ \ 000boo°oboo°oboo°000°oo 000q�a000q�a000q�a000q�a000q�a000q�a000q�a000 4 000�80000�80000�80000�80o00�80000�8 00��0000��0000��0000�a0000�80000�80000�S0000�8 �\ \\ \\ \\ \ // // // // EMBED DOWEL SCORE JOINT (TOOLED W/ 3/ 16" Do 0000 0000 0000 0�00 0�00 00 0000 0000 o�Do o�Do o�Do 000 000 00 o 000 000 000q� 000q-� 000q-��oo 000q� 000q� 000q� 000q� 000ry� 000ry� 000q��oo 000 000 oDo�Oo oDo�Oo oDo�Oo 000 oDo�Oo 0�0�00 0�0�00 0�0�00 oDo�Oo oDo�Oo 0�0�00 000 \j�\j�\j�\j�\ 6" MIN /�\,j�\,j�\,j\\ a., RADIUS) WIDTH NOT TO EXCEED 000 000 000 000 000 000 00 000 000 000 000 000 000 000 3/ 16 . NO TOOL MARK ON EDGES CONCRETE, SEE DETAIL 10\C5.10 0000 00000 00000 00000 00000 00000 000 0000 00000 00000 00000 00000 0000o COMPACTED CRUSHED ROCK >o°roo D°ro0 D°�O D°�O D°�O D°�O D O°D°�O D°�O D°row D°row D°row D°ro °vim D ��00000�00000�00000�00000�00000�00000 00000�oo°°0�00000�00°00�00° 0�00000�00°00�oo°0c SEE DETAIL 10\C5.10 CRUSHED SURFACING BASE -COURSE I SECTION A -A 000°000°000°�ooC°�ooC°�ooC° 000°g`boos°g`boos°g�oo�°g�oo�°g�oo�°�oo�°�ooU°� COMPACT TO 95% MAX DENSITY oo°cU000°cUOo°�Oo°�Oo°�Oo°off o°�Oo°�Oo°�Oo°�Oo°�Oo°�Oo°�Oo°�0� %�/jA/jv/jA//A//v�j��j��/v�jA///v//A//A//A//A//A�/�//;/�;/�;//;//�//v COMPACTED SUBGRADE SCARIFY AND RECOMPACT TOP 6" OF „ �,,. 7" 3 ��o� - NOTE: ���A/`/ SEE DETAIL 10\C5.10 EXISTING SOIL TO 95% MAX DENSITY 9 PLASTIC OR RUBBER WHEEL STOPS MAY BE SCORE JOINT DEPTH TO EXCEED SCORE JOINT (SOILS ENGINEER TO APPROVE EX SUB- . n SUBSTITUTED WITH APPROVAL. MUST BE PORT 1/3 THE DEPTH OF THE GRADE PRIOR TO PLACEMENT OF CONC) STYLE TO ALLOW WATER TO PASS THROUGH. CONCRETE SLAB MIN NOTES: ° - COLD JOINT ° ��� 1. PROVIDE CONSTRUCTION OR CONTRACTION JOINTS PER DETAIL 1 1 s-- Q. ° ° ° a ° ° CONCRETE, SEE DETAIL 10\C5.10 o �p Q c 0 6 0-- o . -- U P E R M IT# U 15000494 a Q o Q O Q O O p O p o p o p o p o p o o p o 0 0000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 0000o COMPACTED CRUSHED ROCK ooq�o Doq�o Doq�o Doq�o Doq�o Doq�o Doq�o Doq�o Doq�o Doq�o Doq�o Doq�o Doq� oq�o D ego° o�go° o�go° o�go° 0�80000�80000�80000��o°0o�ao°0o�ao° o�ao° o�ao° 0�80° o�goo0c SEE DETAIL 10\C5.10 2. SEE SPECIFICATIONS FOR GENERAL CONCRETE PAVING DETAILS. ° �o0o°�bo0o° bo0o° bo0o° bo0o° bo0o° bo0o° bo0o° bo0o° �o0o°�bo0o°�bo0a°�bo0a°�bo01d, OooO�oOooO�oOooO�oOooO�oOooO�oOooO�oOooOC�oOooOC�oOooOC�oOooO�p000O�p000O�p000O�pOooO�oC Do o Do o Do o Do o Do o Do o Do o Do o Do o Do o Do o Do o Do o Do o D 3. SEE LANDSCAPE FOR FINISH, TEXTURE &COLOR. o� _ J o Approved By: Date COMPACTED SUBGRADE o.. � SEE DETAIL 10\C5.10 COLD JOINT Approved By: Date: NTS Concrete PavingControljoint 9 Unreinforced Concrete Slab -on- radNeTS g Port St le Wheel StoTSI2 y p Approved By. Date. Approved By: Date: JA Cti DATE: Y OF WA SA O .� W ; 1 COUGHLIN PORTERLUNDEEN SURVEYED: SCALE: AS NOTED VERTICAHORIZONTAL` NAD 1983/1991 �� CITY OF AUTOMOTIVE TRAINING CENTER RENTON TECHNICAL COLLEGE 04/30/2015 DESIGNED: KAw P LDBOOK: A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION RENTON RENTON WASHINGTON DRAWN: LBJ DRAWING N0: C5, 1 0 PVC 43667 801 SECOND AVENUE - SUITE 900 P: 206/343-0460 SEATTLE, WA 98104 F: 206/343-5691 ONE INCH DATUM Planning/Building/Public Works Dept. cHECKEDJAJ AT FULL SCALE N0. REVISION BY DATE APPR ��s10NAL E��� v,/0 IF NOT INGH SCALE ACCORDINGLY PAVING DETAILS APPROVED: SHEET: OF: 12 1 3 R-381812