HomeMy WebLinkAboutRC 20180911001278Instrument Number: 20180911001278 Document:COV Rec: $105.00 Page-1 of 7
Record Date:9/11/2018 3:17 PM
Electronically Recorded King County, WA
Return Address:
City Clerk's Office
City of Renton
1055 S Grady Way
Renton, WA 98057
DE CLARATION OF COVENANT FOR INSPECTIONAND
MAINTENANCE OF STORMWATER FACILITIES AND BMPS
Grantor: IFonnell Family LLC
Grantee: City of Renton
Legal Description: LOT 3 CITY OF ItLi�TON ip'T LINE ADJUSTMENT NO LUA 15-000237 (BONNELL FAMILY LLC;
_
LOTLINE, ADJUSTMENT) RECORDING NO 20151006900005 (BEING A PORTION OF NE QTR NON Q I R STR 19-23-05)
Assessor's Tax Marcel. III#: 1923059I04 � _ _
IN CONSIDERATION of the approved City of Renton Dutch Bros. Drive-Thru Coffee Standpermit
for application file No. LUA/SWP______.._-.. .. _—_. relating to the real property ("Property")
described above, the Grantor(s), the owner(s) in fee of that Property, hereby covenants(covenant) with the
City of Renton, a political subdivision of the state of Washington, that he/she(they) will observe„ consent
to, and abide by the conditions and obligations set forth and described in Paragraphs l through 10 below
with regard to the Property, and hereby grants(grant) an easement as described in Paragraphs 2 and 3.
Grantor(s) hereby grants(grant), coven ants(covet ian:t), and agrees(agree) as follows:
1. 'The Grantor(s) or his/her(their) successors in interest and assigns ("Owners of the described
property") shall at their own cost, operate„ maintain, and keep in good repair, the Property's stormwater
facilities and/or best management practices ("BMPs") constructed as required in the approved
construction plans and specifications.----.---.--.- on file with the City of Denton and submitted to the
City of Renton for the review and approval of permits).. B15007950 _ The
property's storrawater facilities and/or best management practices ("BMPs") are shown and/or listed on
Exhibit A. The property's stormwater facilities and/or BMPs shall be maintained in compliance with the
operation and maintenance schedule included and attached herein as Exhibit B. St:orrnwater :facilities
include pipes, swales, tanks, vaults, ponds, and other engineered structures designed to manage and/or
treat stormwater water on the Property. Storinwater BMPs include dispersion and infiltration devices, native
vegetated areas, permeable pavements, vegetated roofs, rainwater harvesting systems, reduced impervious
surface coverage, and other measures designed to reduce the amount of stormwater runoff on the
Property.
2. City of Renton shall have the right to ingress and egress over those portions of the Property
necessary to perform inspections of the storrnwater facilities and BMPs and conduct maintenance
activities specified in this Declaration of Covenant and in accordance with RMC 4-6-030.
3. If City of Renton determines that maintenance or repair work is required to be done to any of
the stormwater facilities or BMPs, City of Renton shall give notice of the specific maintenance and/or
repair work required pursuant to RMC 4-6-030, The City ,shall also set a reasonable tune in which such
Page I of 3 F^orni Approved by City Attorney 10/2013
Instrument Number: 20180911001278 Document:COV Rec: $105.00 Page-2 of 7
Record Date:9/11/2018 3:17 PM King County, WA
work is to be completed by the Owners. If the above required maintenance or repair is not completed
within the time set by the City, the City may perform the required maintenance or repair, and hereby is
given access to the Property, subject to the exclusion in Paragraph 2 above, for such purposes. Written
notice will be sent to the Owners stating the City's intention to perform such work. This work will not
corninence until at least seven (7) days after such notice is Trialled. If, within the sole discretion of the
City, there exists an imminent or present danger, the seven (7) day notice period will be waived and
maintenance and/or repair work will begin immediately.
4. If at any time the City of Renton reasonably determines that a stormwater facility or BMP on
the Property creates any of the hazardous conditions listed in RM(..4-4-060 G or relevant municipal
successor's codes as applicable and herein incorporated by reference, the City may take measures
specified therein.
S. The Owners shall assume all responsibility for the cost of any maintenance or repair work
completed by the City as described in Paragraph 3 or any measures taken by the City to address hazardous
conditions as described in Paragraph 4. Such responsibility shall include reimbursement to the City
within thirty (30) days of the receipt of the invoice for any such work performed. Overdue payments will
require payment of interest at the current legal rate as liquidated damages. If legal action ensues, the
prevailing party is entitled to recover reasonable litigation costs and attomey's fees.
6. The Owners are hereby required to obtain written approval from. City of Renton prior to
filling, piping, cutting, or removing vegetation (except in routine landscape maintenance) ntenance) in open
vegetated stormwateT facilities (such as swales, channels, ditches, ponds, etc.), or performing any
alterations or modifications to the storrnwater facilities and BMPs referenced in this Declaration of
Covenant.
7. Any notice or consent required to be given or otherwise provided for by the provisions of this
.1
Agreement shall. be effective upon personal delivery, or three (3) days after mailing by Certified Mail,
return receipt requested.
8. With regard to the matter's addressed herein, this agreement constitutes the entire agreement
between the parties, and supersedes all prior discussions, negotiations, and all agreements whatsoever
whether oral or written.
9. This Declaration of Covenant is intended to protect the value and desirability of the real
property described above, and shall inure to the benefit of all the citizens of the City of Renton and its
successors and assigns, This Declaration of Covenant shall run with the land and be binding upon
Grantor(s), and Grantor's(s') successors in interest, and assigns.
10. This Declaration of Covenant may be terminated by execution of a written agreement by the
Owners and the City that is recorded by King County in its real property records.
IN WJTNESS WHEREOF, this Declaration of Covenant for the Inspection and Maintenance of
Stormwater Facilities and BMPs is executed this Z!L/xN, day of'
e 20 14
A, /
GXANTOR, owner of the Property
GRANTOR, owner of the Property
Page 2 of 3 Form Approved by City Attomey 10/2013
Instrument Number: 20180911001278 Document:COV Rec: $105.00 Page-3 of 7
Record Date:9/11/2018 3:17 PM King County, WA
COUNTY 0FK.1NG )SS'
On this day personally appeared before me:
'. ,_ _.___ __... _._ ..._ .__., to me ]mown to be the individuals described in
and who executed the wit .-n and foregoing instrument and acknowledged that they signed the same as
their free and voluntary act and deed, for the uses and purposes therein stated,
Given under my hand and official seal this L day of
a A9u Printed name ,
Notary Public in and for the State of Washington,
tq;at2l'Y G'Ubhc residing at
Broth G;" "tAjjshirigtc^r�
My Appointrne nt Exp rep Oct 8, 2018
My appointzxaent expires .w.._ _ . _ _ ------
Page 3 of 3 Form Approved by City Attorney 10/2013
Instrument Number: 20180911001278 Document:COV Rec: $105.00 Page-4 of 7
Record Date:9/11/2018 3:17 PM King County, WA
CY
Ln
ilI-J
cr CL rD
'J
z
L)
I
<
w<
U
10"3 C) w
0
C)
ci
U U) CC
C>
CD
V)
Uj
IIII
ti
57<
mlmmffmrmmmkwlmm owl_
w w
w
z
CO
M
0
��v
w
UT
en
Instrument Number: 20180911001278 Document:COV Rec: $105.00 Page-5 of 7
Record Date:9/11/2018 3:17 PM King County, WA
The owner or operator of the project shall be responsible for maintaining the stormwater
facilities in accordance with local requirements. Proper maintenance is important for adequate
functioning of the storrnwater facilities. The following maintenance program is recommended
for this project:
APPENDIX A 1V9A('NTFNANcFw REQUIREMENTS FOR S'i3OW CONTROL, CONVEYANCE, AND WQ FAC:ILITIES
. 5 — CATCH BASINSAND IOL.
Maintenance Defect O Problern
Condition When Maintenance Is Needed
Results Expected When
Component
Maintenance is Performed
structure Sediment
Sediment exceeds 60% of the depth from the
Sump of catch basin contains no
bottom of the catch basin to the invest of the
sediment.
lowest pipe into or out of the catch basin or Is
within 6 inches of the Invert of the lowest pipe
Inn or out of the catch hasin,
Trash and debris
Trash or debris of more then % cubic foot which
No Trash or debris blocking or
is located irnsnediately in front of the catch lasin
potentially blockeng erntsanca to
opening or is blacking capacity of the catch basin
catch basin,
by more than t 0%.
Trash or debris in the catch basin that exceeds
No trash or debris in the catch basin
'f:, the depth from the bottom of basin to invert the
lowest pipe into or out of the basin.
Bead animals or vegetation that could generate
No dead animals or vegetation
odors that could cause complaints or dangerous
present within catch basin.
gases (e.g., meihane).
Deposits of garbage exceeding I cubic foot in
No emid➢ ion present which would
volume.
attract or support the breeding of
insects or rodents..
Damage to frame
Cosner of frame extends more than % inch past
Frame is even with curb.
and/or top slab
curb face into the street (if applicable).
...... .__....
Top slab has holes larger than 2 square inches or
Top slab is free of holes and cracks.
cracks wider than '/, inch,
Frame hot sitting flush on tap slab, i.a. __.__...
Frame is sitting flush can top .slate,
separation of more than '1 inch of the frame from➢
the top slab.
Cracks in walls or
Cracks wider than r. inch and longer than 3 feat„
Catch basin Is sealed and
bottom
any evidence of soil particles entering catch
structurally sound.
basin through cracks, or maintenance person
judges that catch basin Is unsound.
Cracks wider than ! inch and linger than I foot
._..---._......_....____.._...
No cracks more than % leach wide at
at the joint of any iniet/outtet pipe ar any evidence
the joint of arlet?outfet pipe,
of soot particles entering catch basin through
_.
cracks.
Settlement/
Catch basin has settled more than 1 Inch or has
Basin replaced or repaired to designY
misalignment
rotated more than 2 inches out of alignment.
standards.
Damaged pique joints
Cracks wider than P inch at the joint of the
No cracks more than %-inch wade at
inletloutiet pipes or any evidence of soil entering
the Joint of InleUoutlat pipes,
the catch basin at the joint of the inledoutlet
pipes.
Contaminants and
Any evidence of contaminants or pollution such
Materials removed and disposed of
pollution
as rail, gasoline, concrete Slurries or paint.
according to applicable regulations.
Source contrail BMPs implemented if
appropriate, No contaminants
present other than a surface oil Solna.
InleliCti0et Pjpe Sediment
Sediment filling 20% or snore of the pipe.
mleUoutlet pipes clear of sediment,
accumulation
Trash and debris
Trash and debris accumulated in inletloutlet
No trash or debris in pipes.
pipes (includes Roatabies and non-fGoatables),.
Damaged
Cracks wider than l-inch at the joint of the
No cracks more than "%Anch wide at
inbUoutlet pipes or any evidence of soil entering
the joint of the inledoutiet pipe.
at the joints of the inletioutlet pipes.
2009 Surface Venter Design Manuat ..._ Appendix A J/9/2009
A-9
Instrument Number: 20180911001278 Document:COV Rec: $105.00 Page-6 of 7
Record Date:9/11/2018 3:17 PM King County, WA
APPENDIX A MAINTENANCE REQUIREMENTS FLOW CONTROL, CONVEYANCE, AND WQ FACILITIES
5 -- CATCH BASINS AND MANHOLES
Maintenance Clefeet Rec presblern
Condition When Mairnernance is Needed
Results Expected When
Component
Maintenance is Perforoted
Metal Grates Unsafe grate opening
Grade with opening v0do r than 'Is inoh.
Grate opening nerets design
(Catch Basins)
standards.
Trash and debris
Trash and debris that is blocking more than 20%
Grate free of trash and debris,
of grate surface.
footnote to guidelines for disposal
Damaged or missing
Grate missing or broken member(s) of the agate.
Grate is in place and meets design
y opera structure requires urgent
standards,
Maintenance,
Manhole Cover/Lid Cover/lid not in place
Covertlid is missing or only partially In place.
Cover/lid protects opening to
Any open structure requires urgent
Structure.
malintenance.
Lacking mechanism
Mechanism cannot be opened by one
Mechanised opens with proper tools,
Not Working
maintenance person with proper reels- Solis
cannot be srs ated. Self -larking caraver/#id does not
wo,"
Cov'r,id diinC alR Co
One maintenance person cannot remove
CoveriRd can be removed and
RernRaere
cover/lid after applying 80 lies. of fift.
reinstalled by one maintenance
Person,
1/9/2009 2009 Surface Water Design Manual Appendix A
A-i!?
Instrument Number: 20180911001278 Document:COV Rec: $105.00 Page-7 of 7
Record Date:9/11/2018 3:17 PM King County, WA
APPENDIX A MAINTENANCE REQUIREMENTS FOR. FLOW CCb7`d`i'FiOL, CONNVFYANCT, AND WQ FA.CIIA-riES
O. 6 — CONVEYANCE PIPES AND DITCHES
Maintenance
Defect or Problems
C ondithans When Maintenance is Needed
Results Extracted When
Component
Maintenance is Performed
Pipes
Sediment & debris
Accumulated sediment or debris that exceeds
Water flows freely through pillms.
accumulation
20 of the diameter of the pipe.
Vegetationfroots
Vegetation/roots that reduce free mr wernent of
Water flows freely through pipes,
._
water through pipes,
Contaminants and
Any evidence of ccntarninwrts or pollution such
Materials removed and disposed of
pontuion
as oil, gas6me, concrete slurnes or paint.
according to applicable regulations.
Source control [3MPS implemented if
apprapritate. No contaminants
_..._____......_......_._......-
_...... _...
present other than a surface cif l�Prn.
Carnage to protective
_.._.__ _..__
Protective coating is damaged; mast or corrosion
.� __. _ _._ ._.. _
pipe repaired or replaced.
coating or corrosion
is weakening the stn.ectural Integrity of any part of
pipe.
Caarrraged
Any dent that decreases the cross section area of
Pipe repaired err replaced.
pipe by more than 20 % or is determined to have
...
...... .._......
weakened structural integrity of the pipe..
Ditches
Trash and debris
_
Trash and debris exceeds 1 cubic foot per 1,000
Trash and debris cleared train
square feet of ditch and slopes,
ditches.
..4. editnent
Accumulated sediment that eyceeds 20 % of the
Ditch deaned1flusl' ed of all sedir ent
accumulation
_..
design depth.
_. ._.__.......
and debris see that It matches design,.
Noxious weeds
Any noxious ornuisance vegetation which sylay
Noxious and nuisance vegetation
constitute a hazard to County personnel or the
removed according to applicable
public.
regulations, No danger of noxious
vegetation where County personnel
or the public might normally be,.
Contaminants and
Any evidence of contaminants or pollution such
Materials removed and disposed of
pollution
as oil, gasoline, concrete slurries or paint.
according to applicable regulations,
Source control BMPs implenrented it
apptropriate. No contaminants
present other than ¢a surface oil Mot.
Vegetation
Vegetation that reduces free movement of waster
Water flows freely through ditches.
._
through {.filches.
..._
Erosion damage to
.............®.®.......�_.®...., ........__..
Any erosion observed an a ditch 51opn;
.................... _—...
Slopes are not erading,
iope:s
Rock lining out of
One layer or less of rock exists above native soil
Replace rocks to design slandards.
place or missing (it
area 5 square feet or more, any exposed native
Appiicable)
soil.
2009 Surface Water Design Manual _. Appendix A E/9/7.009
A-l1