I.- OR 12"
IOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12- HEIGHT
RECTANGULAR ADJUSTMENT SECTION
T
a/
#3 BAR EACH CORNET
#3 BAR EACH SIDE
HI PA. -1.
PRECAST BASE SECTION
#3 BAR EACH CORNEF
18" MIN
#3 BAR HOOP
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR
PLAIN CONCRETE
12"
ALL METAL PIPE
15,
CPSSP*
(STD. SPEC. 9-05.20)
12"
SOLID WALL PVC
(STD. SPEC. 9-05.12(1))
15'
PROFILE WALL PVC
(STD. SPEC. 9-05.12(2))
15"
x CUHRUGA I ED POLYETHYLENE
STORM SEWER PIPE
NOTES
1. As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed In the
knockouts.
2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
�Y
* PUBLIC WORKS CATCH BASIN TYPE 1 STD. PLAN - 200.00
DEPARTMENT
INTO MARCH 2O08
CONCRETE COLLAR
REBAR TO MEET VANED INLET GRATE
rIF APPLICABLE BY , (SOLID • - •• • ACCESS COVER
CONTRACTOR
����
��1��.)���� rrrrrrr��•.-r��rr��rri
'•'•'•'•'•'•'•'•'•'t l 1II1I1I11 I................JJ
:�2.S02e2.OS�.2, ..I-I-I-i., i►a,....oaeeeee�!�,INSIDE RIM INSIDE RIM INSIDE RIM
rCOLLAR OUTSIDE RIM
OPTIONAL
21$- T-W SLOPED LID
3 i-II
P-9 F-9 . • 5: fO
PERMANENT
POOL LEVEL
FILTRATION
BAY INLET
TYP.
STORMFILTER
CARTRIDGE TYP.
CARTRIDGE
SUPPORT TYP.
FLOW KIT TYP.
B CLEANOUTACCESS CATCHBASIN FOOT
PLUG ON WEIR WALL (TYP. OF 4)
SECTION A -A
StormFilte
E
m
FRAME AND VANED GRATE
yA `70•
5 s"
6" OR 12"
ONE #3 BAR HOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12" HEIGHT
RECTANGULAR ADJUSTMENT SECTION
HWPS
REDUCING SECTION
#3 BAR
EACH CORNER
#3 BAR
EACH SIDE
EACH WAY
PRECAST BASE SECTION
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR
18"
PLAIN CONCRETE
ALL METAL PIPE
21"
CPSSP*
(STD. SPEC. 9-05.20)
18"
SOLID WALL PVC
21"
(STD. SPEC. 9.05.12(1))
PROFILE WALL PVC
21"
(STD. SPEC. 9-05.12(2))
* CORRUGATED POLYETHYLENE
STORM SEWER PIPE
NOTES
1. As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 26". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
#3 BAR HOOP - #3 BAR EACH CORNER
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
Y -
�~ PUBLIC WORKS CATCH BASIN TYPE 1 L STD. PLAN - 200.10
p�$ DEPARTMENT
t�NT MARCH 2O08
STORMFILTER CATCHBASIN DESIGN NOTES
S70RMFILTER TREATMENT CAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. 3 CARTRIDGE CATCHBASIN
HAS A MAXIMUM OF THREE CARTRIDGES. SYSTEM IS SHOWN WITH A 27' CARTRIDGE, AND IS ALSO AVAILABLE WITH AN 18-CARTRIDGE, STORMFILTER
CATCHBASIN CONFIGURATIONS ARE AVAILABLE WITH A DRY INLET BAY FOR VECTOR CONTROL.
PEAK HYDRAULIC CAPACITY PER TABLE BELOW. IF THE SITE CONDITIONS EXCEED PEAK HYDRAULIC CAPACITY, AN UPSTREAM BYPASS STRUCTURE IS
REQUIRED.
CARTRIDGE SELECTION
CARTRIDGE HEIGHT
27'
\ 18"
18DEEP
MINIMUM HYDRAULIC DROP (H)
3.05'
2.3' i
\ 3.3'
SPECIFIC FLOW RATE (gprNsf)
2 gprrLW
1 gprrLW
2gpm1111I
I 1-gpm/fI-
2 gprtVfl:.
1gpm/ft'
CARTRIDGE FLOW RATE (gpm)
22.5
11.25
15
7.5
15
7.5
PEAK HYDRAULIC CAPACITY
1.0
1.0
1
8
INLET PERMANENT POOL LEVEL (A)
1'-0'
1'-0"
2'-0'
OVERALL STRUCTURE HEIGHT (B)
4'41"
319.
4'.9"
GENERALNOTES
1, CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE.
2. FOR SITE SPECIFIC DRAWINGS WITH DETAILED STORMFILTER CATCHBASIN STRUCTURE DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR
CONTECH ANGINEERED SOLUTIONS LLC REPRESENTATIVE. w ContechES.com
3. STORMFILTER CATCHBASIN WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN
THIS DRAWING.
4. INLET SHOULD NOT BE LOWER THAN OUTLET. INLET (IF APPLICABLE) AND OUTLET PIPING TO BE SPECIFIED BY ENGINEER AND PROVIDED BY
CONTRACTOR.
5. S70RMFILTER CATCHBASIN EQUIPPED WITH 4INCH (APPROXIMATE) LONG STUBS FOR INLET (IF APPLICABLE) AND OUTLET PIPING. STANDARD
OUTLET STUB IS 8 INCHES IN DIAMETER. MAXIMUM OUTLET STUB IS 15 INCHES IN DIAMETER. CONNECTION TO COLLECTION PIPING CAN BE MADE
USING FLEXIBLE COUPLING BY CONTRACTOR.
6. STEEL STRUCTURE TO BE MANUFACTURED OF 1/4 INCH STEEL PLATE. CASTINGS SHALL MEET AASHTO M306 LOAD RATING. TO MEET HS20 LOAD
RATING ON STRUCTURE, A CONCRETE COLLAR IS REQUIRED. WHEN REQUIRED, CONCRETE COLLAR WITH QUANTITY (2) #4 REINFORCING BARS TO
BE PROVIDED BY CONTRACTOR.
7. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE
7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 37 SECONDS.
8. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq it).
INSTALLATION NOTES
A. ANY SUB -BASE. BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY
ENGINEER OF RECORD.
B. CONTRACTORTO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE CATCHBASIN (LIFTING CLUTCHES
PROVIDED).
C. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF.
FLOATABLES BAFFLE
PERMANENT
_
FINISHED GRADE POOL LEVEL 1
L LIFTING EYE
(TYP. OF 4)
WEIR WALL x
FILTRATION BAY 5'
INLET 5"
FLOW
INLET STUB
(OPTIONAL)
OUTLET STUB
OUTLET PIPE
2, 0" FROM FLOWKIT
INSIDE CATCH BASI NFOOT
2'-OY2" (TYP. OF 4)
OUTSIDE
SECTION B-B
3-CARTRIDGE CATCHBASIN
STORMFILTER DATA
STRUCTUREID XxX
WATER QUALITY FLOW RATE cfs
PEAK FLOW RATE <1 cfs
RETURN PERIOD OF PEAK FLOW rs
CARTRIDGE FLOW RATE m Xx-
MEDIA TYPE CSF, PERLITE, ZPG, GAG, PHS) XXXXX
RIM ELEVATION �fXX.X)F
PIPE DATA: I.E.!DIAMETER
INLET STUB XX"
OUTLET STUB XXX.XX' )w
CONFIGURATION
OUTLET. OUTLET
O O O OO
i INLET INLET
SLOPED LID `YES\NO
SOLID COVER A'ES\NO
NOTES/SPECIAL REQUIREMENTS:
0.0368 CFS
0.260
0 0 CFS
7.5
30 77
8" IE=28.47
8" IE=27.23
O.D. Omits of pipe W (see note 4)
O.D. compaction
3' -a-3' ma . limit of pipe zone
bedding
D' material IS
for flexible
pipe (see
note 6)
0.15 O.D. min.
o O.D.
limits of pipe
compaction 0.65 O.D. min.
foundation
level
gravel backfill gravel beckfi(l for
for pipe bedding foundations when specified
A = 4" min. 27" I.D. and under
6" min., over 27" I.D.
A. Metal and Concrete Pipe
Bedding for Flexible Pipe
1 0.15 rise min.
Omits of pipe
compaction
rise min.
gravel backfill gravel backfill for
for pipe bedding foundations when specified
B. Pipe - Arch Installation
Rigid Pipe NOTES:
1. Pipe compaction limits shown on this plan are for pipe
construction in an embankment. For pipe construction
In a trench, the horizontal limits of the pipe compaction
zone shall be the walls of the trench.
2. All steel and aluminum pipe and pipe -arches shall be
Installed In accordance with design A.
3. Concrete pipe with elliptical reinforcement shall be
installed in accordance with design A.
4. Concrete pipe, plain or with circular reinforcement, shall
be installed with design A.
5. O.D. is equal to the outside diameter of a pipe or the
outside span of pipe -arch. The dimensions shown as
O.D. with T maximum shall be O.D. until O.D. equals
T; at which point T shall be used.
` V-0" for diameters 12" through 42" and spans through
50". 2'-0" for diameters greater than 42" and spans
greater than 50".
Flexible Pipe NOTES:
1. Provide uniform support under barrels.
2. Hand tamp under haunches.
3. Compact bedding material to 95% max. density; directly
over pipe, hand tamp only.
4. See "Excavation and Preparation of Trench" in sanitary
sewers section of the standard WSDOT/APWA
specifications for trench width "W" and trenching
options. The pipe zone will be the actual trench width.
The minimum concrete width shall be 1 12 I.D. = 18".
5. Trench backfill shall Conform to "Backfilling Sewer
Trenches" In the sanitary sewers section of the
WSDOT/APWA standard specifications, except that
rocks or lumps larger than 1" per foot of pipe diameter
shall not be used in the backfill material.
6. See "Bedding Material for Flexible Pipe" in aggregates
section of the WSDOTIAPWA standard specifications
for the material specifications.
® Backfll material placed in 0.5' loose layers and
compacted to 95% maximum density.
Method B or C compaction (WSDOT/APWA)
standard specifications.)
Pipe
Size
Min, dist.
between
barrels
circular pipe
conc., LCPE, CMP
(diameter)
12" to 24"
12"
30" to 96"
diam. / 2
102" to 180"
48"
pipe - arch
metal only
(span)
18" to 36"
12"
43" to 142"
span / 3
148" to 199"
48"
Y
Gti� o� PUBLIC WORKS PIPE COMPACTION STD. PLAN - 220.00
DEPARTMENT DESIGN AND BACKFILL
MARCH 2O08
Ire
ORy�ti
SEAL Z
CP n
1969
�gsli I NG�d� T G1 4
"J1
ASBUILT PLAN
5/30/18
A-9-BUILT RECU"OnLI.Ii
DRAWINGS..
SURVEYED: SCALE: DATE:
BRH HORIZZOOWAAI: NAD 1983/1991 � CITY OF STORM DRAINAGE DETAILS FlELDB0/K
DRAWN: 1/17
DESIGN JHH AS SHOWN
R E N TO N STARBUCKS AT AIRPORT PLAZA
, J PAGE:
JHH ONE INCH DATUM LANCE MUELLER & ASSOCIATES DRAWING NO:
CHECK TFD AT FULL SCALE Planning/Building/Public Works Dept. RENTON, WASHINGTON 2016067
IF NOT ONE INCH
NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: OR
C9 10
R-393609