HomeMy WebLinkAbout201.00¢Z K CATCH BASIN FRAME AND VANED GRATE (DETAIL 204.00) HANDHOLD N 2� RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION GROUT, TYPICAL (SEE NOTE 5) FLAT SLAB TOP i e o {� 48", 54", 60", 72", 84" OR 96" L MORTAR (TYP.) n IT STEPS OR LADDER o Z MORTAR FILLET � REINFORCING STEEL TYP.) \ N 12" GRAVEL BACKFILL FOR T PIPE ZONE BEDDING SEPARATE BASE INTEGRAL BASE CAST -IN-PLACE PRECAST WITH RISER "O" RING 12" GRAVEL BACKFILL FOR 6= o PIPE ZONE BEDDING SEPARATE BASE PRECAST NOTES 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning 3. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 5. All grade rings, risers, and castings shall be set in mortar in accordance with Standard Specification 9-04.3. PIPE CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM BASE REINFORCING STEEL DISTANCE in2/ft. IN EACH DIRECTION BETWEEN KNOCKOUTS SEPARATE BASE INTEGRAL BASE 48" 4" 6" 36" 8" 0.23 0.15 54" 4.5" 8" 42" 8" 0.19 0.19 60" 5" 8" 48" 8" 0.25 0.25 72" 6" 8" 60" 12" 0.35 0.24 84" 8" 12" 72" 12" 0.39 0.29 96" 8" 12" 84" 12" 0.39 0.29 NOTES 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning 3. The rectangular frame and grate must be installed with the flange down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 5. All grade rings, risers, and castings shall be set in mortar in accordance with Standard Specification 9-04.3. Q Corrugated Polyethylene Storm Sewer Pipe (Std. Spec. 9-05.20) Q (Std. Spec. 9-05.12(1)) Q (Std. Spec. 9-05.12(2)) IY �� + � + PUBLIC WORKS CATCH BASIN TYPE 2 STD. PLAN - 201.00 DEPARTMENT MARCH 2008 PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER BASIN DIAMETER CONCRETE ALL METAL CPSSP Q SOLID WALL PVC Q PROFILE WALL PVC 48" 24" 30" 24" 27" 30" 54" 30" 36" 30" 27" 36" 60" 36" 42" 36" 36" 42" 72" 42" 54" 42" 36" 48" 84" 54" 60" 54" 36" 48" 96" 60" 72" 60" 36" 48" Q Corrugated Polyethylene Storm Sewer Pipe (Std. Spec. 9-05.20) Q (Std. Spec. 9-05.12(1)) Q (Std. Spec. 9-05.12(2)) IY �� + � + PUBLIC WORKS CATCH BASIN TYPE 2 STD. PLAN - 201.00 DEPARTMENT MARCH 2008