HomeMy WebLinkAbout221.2012'• material to be ASTM A 36 Y4" plate galvanized Smooth Coupling Band for Smooth Pipe T Plate Detail coupling band NOTE: 1. The smooth coupling band shall be used in 1 collar (2" pipe) combination with concrete pipe. 2. Concrete pipe without bell and spigot shall not be installed on grades in excess of 20%. weld 3. The first anchor shall be installed on the first weld plate (see detail) section of the lower end of the pipe and remaining anchors evenly spaced throughout the installation. material to be ASTM 4. If the pipe being installed has a manhole or 1 2' x 6' pipe stakes A 36 galvanized after fabrication per ASTM catch basin on the lower end of the pipe, the each side of culvert A 153 first pipe anchor may be eliminated. 5. When CMP is used, the anchors may be attached to the coupling bands used to join flatten to point the pipe as long as the specified spacing is Anchor Assembly not exceeded. Corrugated Metal Pipe 6. All pipe anchors shall be securely installed before backfilling around the pipe. I Y � STD. PLAN - 221.20 + + PUBLIC WORKS DETAILS FOR COUPLING BANDS �NTo� DEPARTMENT FOR CORRUGATED METAL PIPES MARCH 2008