Loading...
HomeMy WebLinkAbout224.00Y K Q m Z pipe O.D. 1'-0 min min end cap or plug flow to second dispersal trench clean out wye from pipe if necessary notched a grade board m in 6" perforated pipe laid flafnevel 2" x 2" notches 18" O.C. type I CB w/solid cover (locking) A A SO' type I CB w/solid cover ❑❑ influent pipe (max design flows0.5 CFS per trench) clean out wye from pipe galvanized 2" x 12" pressure treated grade board filter *15% max for flow control/water quality' treatment in rural areas. PLAN NTS / pipe O.D. SECTION A -A NTS min 6" perforated pipe laid flat clean (<5% fines) 4" - 1 �"washed rock flow to other branching CB's as necessary 18" O.C�—I V- 2" grade board notches 2 NOTES: 1. This trench shall be constructed so as to prevent point discharge and/or erosion. 2. Trenches may be placed no closer than 50 feet to one another. (100 feet along flowline) 3. Trench and grade board must be level. Align to follow contours of site. 4. Support post spacing as required by soil conditions to ensure grade board remains level. + + PUBLIC WORKS 50 FOOT DISPERSION TRENCH STD. PLAN - 224.00 �NTo� DEPARTMENT WITH NOTCHED BOARD MARCH 2008