Loading...
HomeMy WebLinkAbout226.00TRAFFIC RATED CAST IRON CLEAN OUT BOX COYER, CAST IRON VALVE BOX. OR EQUAL - PAVED AREA SOILTInH' COUPLER UNDERVRAIN PIPE SEE NOTE 1 t�f OVERFLOW 1UCTURE OR ?RYA MAIN -1 � p 4 TYPICAL CLEANOUT CONFIGURATION TRAFFIC RATED LOCKING CAST IRON LID OR VALVE BOX PER MANUFACTURER RECOMMENDATIONS SEE 140TE 2 LANDSCAPING _ EXTEND CLEANOUT F" ABOVE DESIGN PONDING ELEVATION OR PER PLAN - 72 DESIGN PONDING ELEVATION 2"x2'xi'THICK CONCRETE COLLAR ADO VALVE BOX EXTENSION OR SOIL PIPE AS NECESSARY TO ACCOMMODATE O 0 OF RISER PIPE FERNCO GASKETED QUIK CAP OR SIMILAR 4" STREAMSED COBBLER PER WMSDOT M311(2) t"I ANOUT TOP LOCATED WITHIN BIQIZETENTION PONDING AREA NOTES: 1 UNDERDRAIN PIPE PER STD PLAN 392 OD DIAMETER TO BE 64NCHES MIN PRIVATE. 84NC11ES MIN PUBLIC 2 CLEANOUT COVER TO BE LOCKING WITH ALLEN HEAL} BOLT, MARKED -DRAIN CLEANOUT,—CLEANOUT," 'UO;' OR SIMILAR GENERAL NOTES: 1 UNDERDRAINS FOR STORMWATER FACILITIES SHALL HAVE AN ACCESS PGINT (CLEANOUJT. OBSERVATION PONT. OR OVERFLOW STRUCTUREjAT EACH END AND AMINIMVM SOF EVERY ifm FEET OF PIPE 2 CLEANGUT PIPE SHALL 8E SAME SIZE AND MATERIAL AS UNDERORAIN PIPE 3. CLEANOUT SMALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 4 ALL FITTINGS SHALL BE SOIL TIGHT 5. CLEANOUT RISER TOP SHALL BE LOCATED OUTSIDE OF FACILITY UNLESS APPROVED OTHERWISE, ANV OUTSIDE OF PONDING AREAS WHERE POSSIBLE UNLESS OTHERWISE Y10TED, DRAWING IS NOT TO SCALE (NISI STD. PIAN - 226.00 03PUBLIC WORKS aPpRcsYEa: DEPARTMENT STfIR�II ATER FACILITY CLEANOUTlATE