HomeMy WebLinkAbout234.10CONTROLSTRUCTURE EMERGENCY OVERFLOW WS OVERFLOW WS V p POND DESIGN WS p a DEBRIS BARRIER 6" SEDIMENT STORAGE V POND DESIGN W.S. TOP WIDTH OF BERM 6' MIN.12'/15' MIN. FOR ACCESS ROAD EXISTING GROUND PROFILE ,wmn MAXIMUM ELEVATION 0 10 -yr W.S. KEY, IF REQUIRED SECTION A -A SECTION a -a SECTION B -B has 2 options L (AS REQUIRED) CIRCUMFERENCE LENGTH OF OPENING FOR 100 yr FLOW OVERFLOW WS p FRAME/GRATE FOR SECONDARY INLET. PROVIDE VERTICAL BARS IN FRAME @ 4"O.C. (OTHER SYSTEMS ACCEPTABLE IF APPROVED BY DDES) SEE ALSO THE SEPARATE OVERFLOW STRUCTURE 2" ASPHALT (FOR SPILLWAYS ON ACCESS ROADS) EMERGENCY OVERFLOW WATER SURFACE 6"MIOVERFLOWWSI��o a�0o Ooio�oo000 p DESIGN WS SECTION B -B V ROCK LINING Emergency Overflow Spillway NTS OVERFLOW WS jDESIGN WS EMERGENCY OVERFLOW WS p p = OHO ao Q ROCK LINING PER 40 COMPACTED COMPACTED o EMBANKMENT / SECTION C -C NOTE: 1.This detail is a schematic representation only. Actual configuration will vary depending on specific site constraints and applicable design criteria. 2.Access Road shall meet the following design criteria. 2.1. maximum grade shall be 15 % for asphalt paving and 12 % for gravel or modular grid paving. 2.2. Outside turning radius shall be 40 feet, minimum. 2.3. Fence gates shall be located only on straingh section of road. 2.4. Access roads shall be 15 feet in width on curves and 12 feet n straight sections. 2.5. A paved apron shall be provided where access roads connect to paved public roadways. 3. All facilities shall be fences. Fence shall be provided around facility allowing proper maintenance per standard details unless otherwise specified. Y + + PUBLIC WORKS TYPICAL DETENTION POND STD. PLAN - 234.10 DEPARTMENT SECTIONS MARCH 2008