HomeMy WebLinkAbout236.00wall flange (typical) -III— III III —III III -VIII o III III II e III III III o I' �-III. 6" min. 1 DESIGN W.S. - flow flow i� restrictor handholds, o o steps or ladder see 0 6"sediment o flow 12"T_� storage o 12"� L2m min. e capacity of outlet pipe not less than developed 100 - yr design flow in. SECTION A -A NTS 4'minimum NOTES: 1. All metal parts must be corrosion resistant. Steel parts must be galvanized and asphalt coated (Treatment 1 or better). 2. Provide water stop at all cast -in-place construction joints. Preceast vaults shall have approved rubber gasket system. 3. Vaults <10' wide must use removable lids. 4. Prefabricated vault sections may require structural modifications to support 5'x 10' opening over main vault. Alternatively, access can be provided via a side vestibule as shown. 5. All vault areas must be within 50' of an access point. 6. For vaults under roadways, the removable panel must be located outside the travel lanes. Alternatively, multiple standard locking manhole covers may be provided. Spacing of manhole covers shall be 12 feet, measured on center, to facilitate removal of sediment. Ladders and hand -holds need only be provided at the outlet pipe and inlet pipe, + + PUBLIC WORKS TYPICAL DETENTION VAULT STD. PLAN — 236.00 DEPARTMENT MARCH 2008 outlet pipe �---------- — SII I a------ �'� III flow, 5% I A MIT, I flow A 5% I L I I I I I I 5'x 10' opening I I I for vaults 2000 sf I I or greater floor area I optional I I PLAN VIEW I 5' x 10' access vault I I NTS may be used in lieu of top access frames, grates and round solid covers marked "DRAIN" with locking bolts. wall flange (typical) -III— III III —III III -VIII o III III II e III III III o I' �-III. 6" min. 1 DESIGN W.S. - flow flow i� restrictor handholds, o o steps or ladder see 0 6"sediment o flow 12"T_� storage o 12"� L2m min. e capacity of outlet pipe not less than developed 100 - yr design flow in. SECTION A -A NTS 4'minimum NOTES: 1. All metal parts must be corrosion resistant. Steel parts must be galvanized and asphalt coated (Treatment 1 or better). 2. Provide water stop at all cast -in-place construction joints. Preceast vaults shall have approved rubber gasket system. 3. Vaults <10' wide must use removable lids. 4. Prefabricated vault sections may require structural modifications to support 5'x 10' opening over main vault. Alternatively, access can be provided via a side vestibule as shown. 5. All vault areas must be within 50' of an access point. 6. For vaults under roadways, the removable panel must be located outside the travel lanes. Alternatively, multiple standard locking manhole covers may be provided. Spacing of manhole covers shall be 12 feet, measured on center, to facilitate removal of sediment. Ladders and hand -holds need only be provided at the outlet pipe and inlet pipe, + + PUBLIC WORKS TYPICAL DETENTION VAULT STD. PLAN — 236.00 DEPARTMENT MARCH 2008