HomeMy WebLinkAbout240.00LADDER (TYP.)
3
Y ACCESS COVER (TYP.) W/LADDER ACCESS
TO VAULT. IF > 1250 SF, PROVIDE 5 X 10
REMOVABLE PANEL OVER INLET/OUTLET PIPE.
m INFLOW 20' MAX
(RECOMMENDED
I lz
O - 3
INLET PIPE (8" MIN.)
MANHOLE
HIGH FLOW BYPASS
PLAN VIEW
NTS
OUTLET PIPE (8" MIN.)
SHUT OFF VALVE W/
RISER & VALVE BOX
5' MAX.
SLUDGE RETAINING BAFFLE
VARIES (CAN BE
CONSTRUCTED ON OIL RETAINING BAFFLE
GRADE WITHOUT FLOW SPREADING BAFFLE
RISERS) (RECOMMENDED)
EXISTING GRADE TEE (8" MIN.)
6" MIN.
£ %\\ — tee i�l —
b \ — OIUWATER 1' MIN
\ forebayD CHAMBER OR (0
min
1' MIN.. 24" MIN.
2' min. 1' min.
REMOVABLE TEE
GRAVITY DRAIN
8' MIN.
D = 3' MIN.
(RECOMMENDED) U3 - L/2 8' MAX.
1' MIN.
(APPROX.)
L=5W
SECTION VIEW
NTS
NOTES:
1. GRAVITY DRAIN SHALL BEAT LEAST 8 INCH MINIMUM DIAMETER AND SHALL BE
CONTROLLED BY A VALVE. USE OF A SHEAR GATE IS ALLOWED ONLY AT THE
INLET OF A PIPE LOCATED WITHIN AN APPROVED STRUCTURE.
I y STD. PLAN - 240.00
+ + PUBLIC WORKS BAFFLE OIL / WATER SEPARATOR
DEPARTMENT
MARCH 2008