Loading...
HomeMy WebLinkAbout241.10TO BYPASS CONVEYANCE SYSTEM OR DETENTION POND q 2d* baffle to control floatables INFLOW DIA. OF STANDPIPE* (2 X DIA. OF OUTLET PIPE RECOMMENDED AS STARTING POINT) TYPE - 2 C.B. _ NO BASE CHANNED REQ'D PLAN VIEW q NTS TO WATER QUALITY FACILITY ROUND SOLID LID BAFFLE TO CONTROL FLOATABLES OR PROVIDE SPILL CONTROL UPSTREAM TOP OF PIPE AT WQ DESIGN WATER SURFACE ELEVATION AND HEAD LOSSES IN OUTLET PIPE INFLOW LADDER (TYP.) SECTION A -A NTS *NOTE: Diameter (d) of standpipe should be large enough to minimize head above WQ design WS and to keep WQ design flows from increasing more than 10% during 100 -year flows. P OF RISER AT DESIGN WS ELEVATION TEE" SECTION WITH CLEANOUT DR REMOVABLE BEND -DOWN ELBOW) =\ TO WATER QUALITY FACILITY ORIFICE SIZED TO PASS WQ DESIGN FLOW � + Y � + PUBLIC WORKS FLOW SPLITTER - OPTION B STD. PLAN - 241.10 DEPARTMENT MARCH 2008