Loading...
HomeMy WebLinkAbout242.10SIDE WITH WING WALLS PLAN VIEW Y K Example of a concrete sump flow m spreader used with a biofiltration swale (may be used with other WQ facilities). 0 C� CONCRETE SUMI` OUTFALL RIPRAP INLET PIPE A A SIDE WITH WING WALLS Note: 1. Extend sides into slope. Height of side wall and wing walls must be sufficient to handle the 100 -year flow or the highest flow entering the facility. 2. Concrete for sump box may be either cast -in-place or pre -cast, but the bottom of the sump shall be reinforced with wire mesh for cast -in-place sumps. 3. Sump boxes shall be placed over bases that consist of 4 inches of crushed rock, % - inch minus to help assure the sump remain level. ROCK A I Y � STD. PLAN - 242.10 + + PUBLIC WORKS FLOW SPREADER OPTION B �NTo� DEPARTMENT CONCRETE SUMP BOX MARCH 2008 PLAN VIEW NTS ij INLET PIPE WING WALL OUTLINE 2" MIN. CLEARANCE C� 8" (MIN.) �i:/���\ VX�/���/� CONCRETE SUMP (4"WALL THICKNESS) 24" (MIN) SECTION A -A NTS Note: 1. Extend sides into slope. Height of side wall and wing walls must be sufficient to handle the 100 -year flow or the highest flow entering the facility. 2. Concrete for sump box may be either cast -in-place or pre -cast, but the bottom of the sump shall be reinforced with wire mesh for cast -in-place sumps. 3. Sump boxes shall be placed over bases that consist of 4 inches of crushed rock, % - inch minus to help assure the sump remain level. ROCK A I Y � STD. PLAN - 242.10 + + PUBLIC WORKS FLOW SPREADER OPTION B �NTo� DEPARTMENT CONCRETE SUMP BOX MARCH 2008