Loading...
HomeMy WebLinkAbout263.40CONFIGURATION ON SLOPING GROUND DOWNSPOUT WITH CLEANOLIT FILTER, SEE DETAIL CLEANOUT PER STC. PLAN 226.[10 10' MIN LEVEL TRENCH WITH PERFORATED PIPE. SEE NOTE 1 5' MIN S - MIN A 11 I � CLEANOUT PER !! STD PLAN225.44 ji — — — — — — — — — — TO STORM DRAIN SYSTEM J I — ----- — ——---_... -- — — — I >a I I 5 6 I MIN MIN 1 I TO STORM DRAIN SYSTEM `DOWNSPOUT WITH CLEANOUT FILTER, SEE DETAIL 1► 10' MIN. LEVEL TRENCH WITH PERFORATED PIPE, SEE NOTE 1 0....,..,..-.....----------------- - -- r CONFIGURATION ON FLAT GROUND COMPACTEQ TOPSOIL OR OTHER CLEAN FILL NON-VWOVEN GEOTEXTILE FOR SEPARATION ON TCP AND SIDES OF TRENCH PER'44SDOT SPECIFICATIONS SECTION %33 2(1) TAEILE 3 PLAN VIEW OF PARCEL 6" MIN PVC PERFORATED PIPE PER ASTM 01785 ° FILTER SCREEN 1 112"- 34" WASHED �e4 rC3 DRAIN ROCK 24" MIN MIN. T ABOVE SEASONAL. HIGH GROUNDWATER TABLE SECTION A S❑LIDSI LEAVES TYPICAL DOWNSPOUT CLEANOUT DETAM NOTES - 1 TRENCH LENGTH TO BE 18 FEET IN LENGTH FOR EVERY 5,004 SF OF CONTRIBUTING IMPERVIOUS SURFACE, ❑R 35.480 SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTON THEREOF. GENEM NOTES: 1 1MRLTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM $!NgLE•FAMILY OR DUPLEX HOMES OR TO CDNTROL BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROL PROGRAM (UICj FOR OTHER TYPES OF RUNOFF MANAGEMENT. 2 IMPERVIOUS AREAS LARGER THAN 14.404 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 36,004 SF MAY REgLJIRE LARGER PIPE AND SHOULD BE DESIGNED BY A OV1L ENGINEER 3. THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25% 4. SEE SECTION C.2. 11 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL FOR ADDITIONAL REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE [NTSj STD. PLAN - 263.40 • JPUBLIMORKS PERFORATED STUB -OUT DEPARTMENT CONNECTION AM Nkw " a DATE 6" MIN. a Ir MIN r� ri � 11 UNDISTURBED NATIVE SOIL PLAN VIEW OF PARCEL 6" MIN PVC PERFORATED PIPE PER ASTM 01785 ° FILTER SCREEN 1 112"- 34" WASHED �e4 rC3 DRAIN ROCK 24" MIN MIN. T ABOVE SEASONAL. HIGH GROUNDWATER TABLE SECTION A S❑LIDSI LEAVES TYPICAL DOWNSPOUT CLEANOUT DETAM NOTES - 1 TRENCH LENGTH TO BE 18 FEET IN LENGTH FOR EVERY 5,004 SF OF CONTRIBUTING IMPERVIOUS SURFACE, ❑R 35.480 SF OF NON-NATIVE PERVIOUS SURFACE, OR PORTON THEREOF. GENEM NOTES: 1 1MRLTRATION TRENCHES LIMITED TO ROOF RUNOFF FROM $!NgLE•FAMILY OR DUPLEX HOMES OR TO CDNTROL BASEMENT FLOODING. CONSULT WA DEPARTMENT OF ECOLOGY REGULATIONS FOR UNDERGROUND INJECTION CONTROL PROGRAM (UICj FOR OTHER TYPES OF RUNOFF MANAGEMENT. 2 IMPERVIOUS AREAS LARGER THAN 14.404 SF AND NON-NATIVE PERVIOUS AREAS LARGER THAN 36,004 SF MAY REgLJIRE LARGER PIPE AND SHOULD BE DESIGNED BY A OV1L ENGINEER 3. THE PERFORATED PIPE MAY NOT BE PLACED IN A CRITICAL AREA BUFFER OR ON SLOPES STEEPER THAN 25% 4. SEE SECTION C.2. 11 OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL FOR ADDITIONAL REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE [NTSj STD. PLAN - 263.40 • JPUBLIMORKS PERFORATED STUB -OUT DEPARTMENT CONNECTION AM Nkw " a DATE