Loading...
HomeMy WebLinkAboutR-3906111 r Irrigation C I SYM. EQUIPMENT PSI GPM Radius I , ® RAINBIRD 1800PRS 15 SERIES MPR H 30 1.85 15' I ( I I 0 RAINBIRD 1800PRS 15 SERIES MPR F 30 3.70 15' �� ' ��� :✓ S89°44'59"E 91.00' 3 1 f MP1000-90, adjustable from 90 to 210 40 .19 8 -15 I I 1 R- MP1000-210, adjustable from 2100 to 2700 40 .37 8- 15' -------------------=----- ----------------- ------ --- --------------- -15'-- MP1000-360 3600 40 .75 8' nn nn M -_ M M nn nn M nn nn __------_-- nn _______-- ^^ -!- ^^ -------------------------------- -w--------- ------------------------------- --------------------- )- s I r_ e MP2000-90 = 13' to 21' radius, adjustable from 900 to 2100 40 - I- I 40 13 21 o ---�-------- �� -- - - ---- 1: B MP2000-210 = 13' to 21' radius, adjustable from 2100 #0 270° 40 .74 13'-21' _ ��► ISO NT OF ONNECTION I 1 i N (; I K. f ©.../ ® MP2000-360= 13'to21'radius, 3600 40 1.47 13'-21' --------- ---------) ---=�� --- P.O-C. -----------------,------- - - --- -I . + I l' i- . ..: I �. MP3000-90 = 22 to 30 radius, 4� S EVE 11ND R ALL 4 adjustable from 90 to 210 40 .86 22 -30 MP3000-210 = 22' to 30' radius adjustable from 2100 to 2700 40 1.82 22-30' 1 :. ;... I ....... / I ® - - 1 .DRIV/EWAYS TY ? ►: 1 i F MP3000 360 - 22 to 30 radius, 360 40 3.64 22 30 I i / ® S89.4459"E 5 00' MA K LOCATION ON CURES --- - - __ - - ----- - - ------------------ - -- ---1=- -1-- : 0 1 r --- - ---- ---------- - _ ._ _ �_ - __ ---4"' / I MPLCS515 Left corner strip,5 x 15 40 .22 15 �---_.. 1 S - x _. r ® MPRCS515 - Right corner strip,5 x 15 40 .22 15 ► ": :.:. :, O _. . = �, - v O; T 0 O. ► E / / ® IF MPSS530 - Side strip,5 x 30 40 , E i. «l .. _... .... .............. .. _... ...._ _.....,. ........ . MPCORNER - 8 to 15 radius adjustable from 45 to 105 40 c: 1 .19,.39,.45 8-15 I : y....__......,0....... �, H, 0,:`� 0.... �,_; _::::.::::....................................... / 11 9 O.... O. E?.... a......J / 1 1 „ ; I / O / , o_ c ..�_......�... Q r e HUNTER 1.20.60.36V. ADV. STD. N. 40 1.0 40 1, :. ............................. ....,..,..................................... ® f ............ .,:. .. .... .. .., ...;...... ., is jj _............. .... =s. / HUNTER 1.20.60.36V ADV. STD. N. 40 2.0 40 I ❑ ❑ ::. / w 4 O :: ❑ I HUNTER 1.20.60.36V. ADV. STD. N. 40 4.0 40' ❑;; 0 5 - RAINBIRD - 5RC - QUICK COUPLER VALVE 41 - RAINBIRD OR NETAFIM DRIP ZONES - 24" DRIP LINE IN SENSOR 1 1 I .fir' / i , 1 / cr j/ ,, ✓3 OODINATE LOCAL" ON W/ G.C. AQUA BALL VALVE (1-1/2) 200 PSI THREADED ENDS 1 I pNTROLLER >O ATION 11 4"SLEEVE / FEBCO DOUBLE CHECK ASSEMBLY- 850J-DC ( 1-1/2) I I W COORDINATWI H G.C. / _ - I ® ! UNDER SIDkWALK Lr),v: G.C. TOP OVIDE POWE TO CLOCK 11 �- ..., ► / ' � MARK'EDGE OF STRAINER -WILKINS (1-1/2") /® �;. ... ( .._ BRASS STRAINER WITH 100 MESH SCREEN „ ► w.., I LL _ / SIDEWAL WHERE SLEEVE ARE PRESSURE REDUCING VALVE - WILKINS PRV 600 SERIES LO AT INSTALL ONLY IF PRESSURE EXCEEDS 75 PSI I = 4 � E 11 w ❑ 2 SLEEV ❑ ICV - G SERIES AUTO CONTROL VALVE ;; ► / ► UNOER AL WALKWAYS T 1 WATER METER, P.O.C. 11 BUILDING TYPI II f Imo/ ® RAIN SENSOR W/ BY-PASS SWITCH I ❑ ,r 1 2 MAITYR ., NLIN -D CHAMPION MANUAL DRAIN VALVE �� � T RAINBIRD ESP -ET STATION IN WEATHERPROOF CASE MOUNTED ON BUILDING _..__ _««w __....; _.... ___.._ ... .................... / C GENERAL CONTRACTOR TO SUPPLY 110 POWER SOURCE FOR CLOCK-� .. \ . / r q N894459"W 129.46' DRIPLINE - NETAFIM OR EQUIV. 24" SPACING EMMITERS - - - 11��------______-_ ��------- -- ---- - --.--. - _ - --- 1/ ;'� �11 SLEEVE°..NDER SIDE W LK 1/2 THRU 1-1/4 SCH. 40 PVC LATERAL LINE , -- -.- - - _ - 1 1/2" SCHEDULE 40 PVC MAINLINE - - - - - - - - -- - ----------------------------= = =- - _ - - - - - - -__ - - - 4. ___ -------------.A - ------ _ -- ---- ------- NONE DIRECT BURY CONTROL WIRING, USE WHITE AS COMMON - --J RED FOR SIGNAL, AND YELLOW AS SPARE NONE ARMOR BACKFLOW BOX W/ LOCKING LID NONE ARMOR CONTROL VALVE BOX W/ GREEN LOCKING LID i %7' -It NONE ARMOR MANUAL DRAIN VALVE BOX W/ GREEN LID GRAPHIC SCALE N 10 0 5 10 20 IRRIGATION PLAN IRRIGATION NOTES 1. Irrigation system engineering based on a 1" water meter connection. The installer to verify ( IN FEET ) adequate static water pressure at time of installation. System designed to run at 40 PSI. 1 inch = 10 ft. Install pressure reducer when necessary. 2. Irrigation lines are that are shown within hard surface areas for clarity, shall be located within landscape planting areas or underground sleeves. All valves shall be installed within protective boxes installed flush and level with finished grade. 3. Install all equipment per state and local codes. Call Line Locaters prior to digging at 811. The installer shall be responsible for all permits, tests and inspections as required. 4. See civil drawings to verify all utility locations. 5. Coordinate with the general contractor for the required power and installation of sleeving, IMPORTANT NOTE: 1. CONTRACTOR SHALL COORDINATE PLACEMENT OF IRRIGATION 6. Install manual drains at all low points and record all locations on the "Record Drawings". SLEEVING PRIOR TO ANY PAVING OF HARD SURFACES. GENERAL 7. Adjust radius on all sprinkler heads to maximize the coverage and minimize overspray on all CONTRACTOR SHALL NOTIFY LANDSCAPE CONTRACTOR OF ANY hard surfaces. Add anti -drain check valves to low heads to eliminate drainage and run-off. PAVING PRIOR TO INSTALLATION OF PAVING TO ALLOW TIME FOR 8. Install the Controller as per detail, coordinate with the General Contractor for 110 volt power PLACEMENT' OF SLEEVING. required. Provide and install rain sensors on an eight foor past near each controller. 2- ALL SLEEVING SHALL BE LOCATED WITH MARKINGS ON THE 9. Main line& wiring to have a minimum cover of 18" and all lateral piping 12". VERTICAL EDGE OF THE CONCRETE PAVING BY THE CONCRETE 10. Use select "rock free" materials to backfill all trenches and compact to 85°lo density for CONTRACTOR AT TIME OF POUR. 1`? landscape areas and 95% for areas under concrete or asphalt. 3. IRRIGATION CONTRACTOR SHALL INSTALL A VISUAL POP UP 11. As part of the contract, the landscaae contractor is to winterize in the fall and activate the INDICATOR AT EACH ZONE OF DRIP LINE. RAINBIRD X17500 . system in the spring for one year. NatureBy Landscape Architecture ,qqr 253.460.6067 1320 Alameda Avenue, Suite B, Fraest, WA 98M www.naturebydesigninc.com p � CQ I �z� oZ a �Qa w 4 �a 0 a REVISIONS: B. REVISED PER CITY COMMENTS C. REVISED W NEW BASE PLAN DRAINING ISSUED FOR: AGENCY REVIEW DATE: OCTOBER 21, 2016 STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECT KATHERINE OWENS CERTIFICATE NO.692 PROJECT NO.: 1611 FILE NAME: 1611 LSC X REFS: CES DRAWN BY: KLO CHECKED BY: KLO PLOT SCALE: 1:1 DRAWING SCALES: 1"=10'-011 coaa®',3 9®4,!}