Loading...
HomeMy WebLinkAboutR-390604TO (3) (' ) 0 I r) W LE.(6n IN)=195.00 1 MIN COVER OVER .� / 4 LE.(6nOUT)=8 195.01 / I TRNECH . � PROVIDE STORM SEDIMENT CONTROL STRUCTURE I CLEANOUTS FOR00 PER DETAIL ON SHEET C8. II \ MAINTENANCE / / • / a 0 EP=196.00 050 \ - Ie% Unit ROOF DOWNSPOUT 4 " I �' to rn CLEAN OUT (TYP.) 5LF 6 ADS N- 12 / 0 1.007.(MIN.) �I ` / / ®C� �I F.F. ' L 7198.6 F.F. EL.=200.6 �F�EL.=200.6 F.F. EL=20�.6 F.F. EL=202.6 / // ®Set• I ® D , SFo� IZD Lo 0 31 4 4 6" PVC SDR, 35 ROOF DOWNSPOUT SEWER CLEANOUT // ���h // ST \ I SEWER LINE I(TYP.) a LINE (TYP.) (TYP-) blol T . , C3 C, r . R a R 2OSq a .4 ) 02�4 D-4 I< RD L0. a . / l _ ��, (�oq, s \ ® °% N Oi( ' ° o �%� . Q ® ° a 13 O ° �0.53% a aA / i� a a x / //�0�. a . I / �� / tioA / Zp8 �\ N89°44'59"W - - - - ���;' ��;/`l� / C �� / �/------- -- — �— _ {- - -v— — — �— — — / 4 — T — — — — — — \ III 4 d - - - - -- — — ---- a d --=--------------- —I r ------------ EXISTING 5 UTILITY _ _ - - \ - - r TOP OF WALL EL: 202.70t \ EASEMENT PER AFN# R - - \ \ / BOT. OF WALL EL:202.25 \\ /� \ 7709060799 TOP OF WALL EL•206.00f TOP OF WALL EL:198.30 I / TOP OF WALL EL: 200.25 � � PN BOT. 0� WALL EL:204.00 , BOT. OF WALL EL:196.80f BOT. OF WALL EL:199.50f - _ \ / 8137900000 \ I a PROPOSED GROUND @ CENTERLINE -A mAb 210 1 205 1 200 195 SITE ADDRESSi 905 1 NE 98056 FACE OF WALK IS TO BE CONSTRUCTED FLUSHED WITH THE LIGHTPOLE'S FOUNDATION. ASSUILT RECORD 140TE THE SHOWN HORIZONTAL AND VERTICAL LOCATIONS OF THE STORM DRAINAGE AND ROAD SYSTEMS WAS FIELD SURVEYED BY ME OR UNDER MY DIRECTION. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. \ NOTE: SLOPE GROUND AT A MAXIMUM \ / SLOPE OF 4:1 UP TO 3 FEET FROM THE \ BACK OF SIDEWALK '10/�Aj k p6 / i v OF SHARED ACCESS. RP RP SC SC w �� �� N z ®L6 �� N�� W Nr)j N +N +N oNco m m r�� w II +N II d- 11 +WN W w Oo a WW> = II o o II W H 11 � ¢ > z J U cr_ cn fn W � ¢ � c� i - � J c d cn :mw _ cn W C" M Oui i �+C4 6 O �+N cWi V)U-i �ui- 1.50% ----- - i CD DA EXISTING GROUND 0 CENTERLINE OF SHARED ACCESS. -- -SHARED ACCESS - STA:3+00.00 TO STA:4+90.00 _ 1" =10' HORZ. 1" = 5' VERT. o o n C) rn rn CDO N N C) N O� N N N N N z W aZ Q J J mo _ =o V) W WALKWAY s o- JRB z p �wW w J J z I—i " Q ® O U ® O aj ¢cam Boa W ~ fn 2' MIN. L . lit 3/8" EXPANSION JOINT o d- u `V 1-1/2" STEEL PIPE (TYP.) <s 4" MAXIMUM (TYP.) HANDGRIP-a� a J a STEEL PIPE CONSTRUCTION NOTES IT INSTALL 2-48LF INFILTRATION TRENCHES PER THE TYPICAL SECTIONS ON SHEET C8. D® PAVE DRIVEWAYS AS PER THE TYPICAL SECTION ON SHEET C8. DA PAVE DRIVE AISLE AS PER THE TYPICAL SECTION ON SHEET C8. CONSTRUCT 5' WIDE CONCRETE WALKWAY AS PER THE DETAIL ON SHEET C8. ST CONSTRUCT CONCRETE STAIRS AS PER THE DETAILS ON THIS SHEET. RP RESTORE PAVEMENT AS PER THE DETAIL ON SHEET C7. SC SAWCUT FULL DEPTH. WHERE NEW ASPHALT JOINS EXISTING, THE EXISTING ASPHALT SHALL BE CUT TO A NEAT VERTICAL EDGE AND TACKED WITH ASPHALT EMULSION TYPE CSS-1 IN ACCORDANCE WITH SECTION 9-02.1(6) OF THE CURRENT WSDOT STANDARD SPECIFICATIONS. THE NEW ASPHALT SHALL BE FEATHERED BACK OVER THE EXISTING TO PROVIDE FOR A SEAL AT THE SAWCUT LOCATION AND THE JOINT SEALED WITH GRADE AR-4000OW PAVING ASPHALT. EC REPLACE EXISTING EXTRUDED CURB PER THE DETAIL ON SHEET C7. PAINT CURB RED TO MATCH EXISTING FIRE LANE STRIPING. R® RETAINING WALL DESIGNED BY OTHERS. SEE CONCRETE WALKWAY DETAIL ON SHEET C8 FOR MORE GRADING INFORMATION. CD REPLACE EXISTING DRIVEWAY ENTRANCE WITH A NEW CEMENT CONCRETE DRIVEWAY ENTRANCE WITH BUFFER PER CITY STANDARD PLAN 104.2 AND 104.4 ON SHEET C7. GENERAL NOTES CURB DAMAGED DURING CONSTRUCTION SHALL BE REPLACED IN KIND. SEPARATE BUILDING PERMIT IS REQUIRED FOR ANY WALL 4 FEET OR TALLER. THE TYPE OF FLOW CONTROL BMP PROVIDED IS LIMITED INFILTRATION USING TRENCHES. 11" 4" MIN. 7" MAX STEP DETAIL \-6" 4" R.(TYP.) 3" 3-44 LONGITUDINAL BARS EQUALLY SPACED. j #4 BARS 0 24" O.C. TRANSVERSE 23" MIN SECTION . 4 ' NOSING MUST BE FLUSH, NOTES: SLIP -RESISTANT AND ROUNDED TO 1/2" 1. CONCRETE SHALL BE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. CEMENT CONCRETE STAIRWAY [P IAVTEI 12" 3/8" EXPANSION JOINT N TS VERTICAL SPICKETS, 1/2"x1/2" SOLID BAR (0,850 LB/FT) f 4'-0" HANDGRIP 1-1/2" SQ. BOX 14 GAUGE MIN. { THICKNESS NEWELL POST 1-1/2"- SQ. BOX, 14 GAUGE MIN.WALL THICKNESS. 6"J S I A RAILS I IV 1 NTS 2" TO 4" LOWER RAIL 1-1/2" SQ. BOX 4" MAXIMUM (TYP.) TUBE STEEL CALL 48 ; BEFORE 1 811 3+00 3+50 4+00 4+50 H-390604