HomeMy WebLinkAboutD-373102c,
r`
C�
N
>
>W
LEGEND
EXISTING
PROPOSED DESCRIPTION
RIGHT OF WAY
EASEMENT
CONTOUR INTERVAL
CONTOUR INDEX
ABBREVIATIONS
AP
APPROX
BLDG
BOT
CB
CPEP
CL
ANGLE POINT
APPROXIMATE
BUILDING
BOTTOM
CATCH BASIN
CORRUGATED POLYETHYLENE PIPE
CENTER LINE
GENERAL
1.
2.
3.
NOTES
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH STATE, LOCAL AND FEDERAL PERMITS.
ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARDS
AND SPECIFICATIONS AND WASHINGTON STATE DEPARTMENT OF TRANSPORTATION "STANDARD
SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION," 2016 AND AS AMENDED
BY CITY OF RENTON SUPPLEMENTAL SPECIFICATIONS AND THE CONTRACT SPECIAL PROVISIONS.
ALL WORK WITHIN THE SITE SHALL BE SUBJECT TO THE INSPECTION OF THE CITY ENGINEER
OR DESIGNATED REPRESENTATIVE.
NOTES
1. ALL SIGNS SHALL BE MOUNTED ON NEW POSTS UNLESS OTHERWISE
SPECIFIED.
2. BOTTOM OF LOWEST SIGN SHALL BE AT LEAST 7.0' ABOVE FINISH GRADE.
FOR 2 OR MORE SIGNS, BOTTOM OF LOWEST SIGN SHALL BE AT LEAST
6.0' ABOVE FINISH GRADE
3. SIGNS SHOULD BE MOUNTED ON POST IN A WAY THAT THE OUTSIDE EDGE
SHALL BE AT LEAST 24" FROM THE PROJECTION OF THE FACE OF CURB.
BUILDING EDGE
CMP
CORRUGATED METAL PIPE
BUILDING OVERHANG
COM
COMMON
4.
PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL MEET WITH THE CITY ENGINEER
4. PAINTING, THE FACE AND EDGES OF THE 1/2 INCH PLYWOOD SIGN BOARD
COMM
COMP
COMMUNICATION
COMPACTED
FOR A PRE —CONSTRUCTION MEETING.
SHALL HAVE ONE PRIME COAT AND TWO COATS OF EXTERIOR ENAMEL.
— —
EDGE OF PAVEMENT
CONC
CONCRETE
THE POSTS, BRACES AND BACK OF SIGN BOARD SHALL HAVE ONE COAT
— — — — — —
LANE LINE
5.
A COPY OF THESE APPROVED PLANS AND PROJECT SPECIFICATIONS MUST BE ON THE SITE
OF PRIMER AND EXTERIOR ENAMEL. THE BACKGROUND COLOR IS WHITE.
CTRL
CONTROL
WHENEVER CONSTRUCTION IS IN PROGRESS.
0
0 FENCE LINE
CSBC
CRUSHED SURFACING BASE COURSE
5. LETTER TYPES. THE LETTER TYPE SHALL BE SOLID HELVETICA MEDIUM
FENCE LINE
6.
PRIOR TO ANY SITE CONSTRUCTION THAT INCLUDES CLEARING OR GRADING, THE SITE
EXCEPT THE LOGO WHICH WILL BE PROVIDED BY THE CITY. ALL LETTERS
DEPT.
DEPARTMENT
CONSTRUCTION LIMITS SHALL BE LOCATED AND IDENTIFIED BY THE CONTRACTOR'S PROJECT
AND NUMBERS WILL BE BLACK.
A A RETAINING WALL
DIA
DIAMETER
SURVEYOR AND APPROVED BY THE CITY.
----------TV-
ry
UNDERGROUND CABLE —TV LINE
D/W
DWG
DRIVEWAY
DRAWING
6 LETTER SIZE. 4" LETTERS ARE 1/2" WIDE; 3" LETTERS ARE 3/8" WIDE;
7.
TEMPORARY EROSION AND SEDIMENT CONTROL FACILITIES SHALL BE CONSTRUCTED PRIOR TO
2" LETTERS ARE 1/4" WIDE.
— — — — — FIT—
UNDERGROUND COMMUNICATION LINE
OVERHEAD ELECTRICAL LINE
E
FASTING
ANY GRADING OR EXTENSIVE LAND CLEARING IN ACCORDANCE WITH APPROVED TEMPORARY
EROSION AND SEDIMENT CONTROL PLAN. THESE FACILITIES MUST BE SATISFACTORY MAINTAINED
---P
ELEC
ELECTRICAL
UNTIL CONSTRUCTION AND LANDSCAPING IS COMPLETED AND THE POTENTIAL FOR ON —SITE
— — — — — BP—
UNDERGROUND ELECTRICAL LINE
ELEV/EL
ELEVATION
EROSION HAS PASSED.
EOP
EDGE OF PAVEMENT
O,
— — — — — BT—
UNDERGROUND FIBER OPTIC LINE
ESC
EROSION AND SEDIMENTATION CONTROL
8.
PUBLIC STREETS SHALL BE CLEANED ONCE PER DAY OR AS DIRECTED BY THE CITY.
2
D
UNDERGROUND NATURAL GAS LINE
EXIST/EX
EXISTING
FLUSHING STREETS WITH WATER WILL NOT BE ALLOWED.
Sunset Community Low Impact Development Retrofit Green Connection:
S
-----So-----SD-
UNDERGROUND SANITARY SEWER LINE
—So UNDERGROUND STORM DRAIN LINE
FT
FEET
9.
LOCATIONS OF EXISTING UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR VERIFYING THE LOCATIONS OF EXISTING UTILITIES PRIOR TO CONSTRUCTION.
Harrington Avenue NE
ECbLdG This project IS funded In part b the `
�......... „ P 1 P Y
GALV
GALVANIZED
UTILITIES SHOWN ARE FOR THE PURPOSE OF ASSISTING THE CONTRACTOR IN LOCATING SAID
Washington State Department of Ecology +�
— — — — — W—
UNDERGROUND WATER LINE
GPS
GLOBAL POSITIONING SYSTEM
UTILITIES. CONTRACTOR SHALL CONTACT UNDERGROUND UTILITIES LOCATION CENTER
FUNDING:
®
CONTROL POINT (MISCELLANEOUS)
GV
GATE VALVE
(1-800-424-5555) 48 HOURS PRIOR TO BEGINNING OF CONSTRUCTION AND OBTAIN ON -SITE
DEPARTMENT OF ECOLOGY GRANT: $675,000 4'0"
UTILITY LOCATIONS.
CITY OF RENTON SURFACE WATER UTILITY SHARE: $225 000
°
CONTROL POINT (OTHER)
HORIZ
HORIZONTAL
TOTAL: $900,000
GATE POST
10.
CONTRACTOR SHALL COMPLY WITH ALL OTHER NECESSARY PERMITS AND REQUIREMENTS BY
PROJECT MANAGER: BETH TAN, 425-430-7247, Btan@rentonwa.gov
D
INSIDE DIAMETER
THE CITY OF RENTON. SEE APPROVED PERMITS AND PERMIT REQUIREMENTS IN PROJECT SPECIAL
CONSTRUCTION CONTRACT AMOUNT:(awarded amount)
a
SINGLE POST SIGN
IE
INVERT ELEVATION
PROVISIONS.
CONTRACTOR: (name & contact info)
SCHEDULE: (month/year to month/year)
�a
DOUBLE POST SIGN
LF
LINEAL FOOT
11.
CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF TRAFFIC CONTROL PLANS. CONTRACTOR
III
MAILBOX
LP
LOW POINT
SHALL SUBMIT PLANS TO ENGINEER FOR APPROVAL PRIOR TO IMPLEMENTATION.
1'O" 4'x8'1/2" EXTERIOR PLYWOOD
®
LT
LEFT, LIGHTING JUNCTION BOX
(SMOOTH BOTH SIDES,ABX)
BOREHOLE
2.
DRAINAGE STRUCTURES AND RELATED DETAILS SHALL CONFORM TO CITY OF RENTON STANDARD
2"X4"DIAGONAL BRACE
0
COMMUNICATION MANHOLE
MAX
MAXIMUM
DETAILS.
DF STD & BTR, TYR TVABOVE
®
SANITARY SEWER MANHOLE
MH
MIN
MANHOLE
MINIMUM
ROADWAY
(MIN)
i
❑
o STORM DRAIN CATCH BASIN
MISC.
MISCELLANEOUS
13.
FOR CATCH BASIN AT THE CURB, THE OFFSETS SHOWN ON PLANS ARE TO THE FACE OF CURB.
FOR STRUCTURES AT THE BIORETENTION SWALE, THE OFFSETS ARE TO THE CENTER OF GRATE.
4"X4"X12'VERTICALPOSTS
TREATED,
1-
MON.
MONUMENT
—7—
®
STORM DRAIN MANHOLE OR
O
14.
ALL PIPE TRENCH BACKFILL SHALL BE IMPORTED TRENCH BACKFILL UNLESS THE NATIVE SOIL IS
CATCH BASIN TYPE 2
N
NORTHING
SUITABLE FOR BACKFILL AND APPROVED BY THE ENGINEER.
NAVD
NORTH AMERICAN VERTICAL DATUM
°
COMMUNICATION UTILITY PEDESTAL
NGVD
NATIONAL GEODETIC VERTICAL DATUM
15.
FOR STORM DRAIN CROSSING OF UTILITIES WHERE THERE IS LESS THAN 1'-0" VERTICAL
GUY ANCHOR
NO.
NUMBER
CLEARANCE BETWEEN PIPES, PLACE 1' X 1' X 4" STYRENE FORM BETWEEN PIPES.
TY
NTS
NOT TO SCALE
0—
GUY POLE
6.
BEDDING FOR STORM SEWER PIPE SHALL BE PER CITY OF RENTON STANDARD PLAN 220.00
O-
LIGHT POLE WITH ONE ARM
OC
ON CENTER
"PIPE COMPACTION DESIGN AND BACKFILL".
OHW
ORDINARY HIGH WATER
o
POWER POLE
17.
ABANDON OR REMOVE EXISTING WATER LINE AFTER THE NEW WATER LINE IS INSTALLED AND IN
SERVICE.
i
LIGHT POLE WITH NO ARM
PC POINT OF CURVATURE
®
PROP PROPOSED
ELECTRICAL JUNCTION BOX
PT POINT OF TERMINAL
®
ELECTRICAL PANEL BOX
SECTION INDICATOR
0
FIBER JUNCTION BOX
R RADIUS
REF REFERENCE
GAS VALVE
REINF REINFORCEMENT
DRAWING ON WHICH SECTION IS CUT (C-1):
ROW RIGHT OF WAY
❑
CATCH BASIN
RT RIGHT
Q]
TRAFFIC JUNCTION BOX
SECTION LETTER
SD STORM DRAIN
A
- R
-
FIRE HYDRANT
SDCB STORM DRAIN CATCH BASIN
C-5
FIRE DEPARTMENT CONNECTOR
SDMH STORM DRAIN MANHOLE
DRAWING REFERENCE NUMBER
WATER VALVE PIV
SS SANITARY SEWER
ON WHICH SECTION APPEARS
STA STATION
i D4
►�
WATER VALVE
STD STANDARD
B3
®
WATER METER
T TOWNSHIP
DRAWING ON WHICH SECTION APPEARS (C-5):
TREE
TJB TELEPHONE JUNCTION BOX
SECTION LETTER
EROSION AND SEDIMENT CONTROL
SECTION
Q
BUSH
TYPC TEMPORARY
YPICAL
O
STUMP
SCALEUTIL
rDRAWNG
UTILITY
O
WATER PRESSURE REDUCTION VALVEUNDGND
UNDERGROUND
REDUCER
REFERENCE
E
VERT VERTICAL
NUMBER ON WHICH
SECTION IS CUT
W WATER LINE
DRAINAGE STRUCTURE ID:
WM WATER METER
3i
WSDOT WASHINGTON STATE DEPT. OF TRANSPORTATION
X-Y
9
WSEL WATER SURFACE ELEVATION
WV �,�,�pC�� VALVE
DRAINAGE STRUCTURE ID
aT�A"Wa.
SITE PLAN SHEET NUMBER
19]�][1L1[4lG11
DRAWING ON WHICH DETAIL IS REFERENCED (C-1):
DETAIL NUMBER
C15
DRAWING REFERENCE NUMBER
ON WHICH DETAIL APPEARS
DRAWING ON WHICH DETAIL IS APPEARS (C-5):
DETAIL DETAIL NUMBER
SCALE 2C-1RAWING REFERENCE
NUMBER ON WHICH
DETAIL IS REFERENCED
PROJECT SIGN
DETAIL
NTS TYP
a
RECOMMENDED V NSA E N/A I—. . wi9 �05/05/201
FOR APPROVAL �'�• �. STICK CITY OF HARRINGTON AVENUE NE PHASE II
RENTON
SUNSET COMMUNITY - GREEN CONNEC1I0I,I oBY J. wi�soN DATUM w
C44211ASsIm BY ) °"`°R. CHUNG � Planning/Building/Public Works Dept. ABBREVIATIONS 1 LEGEND 1 GENERAL NOTES G - 2
T N0, REVISION BY DATE APPR . scene ..ccoxoixar cam.
�D. ATCHISON 2 24
D-373102