Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutRS_Drainage_Report_181119_v1.pdf - 1 -
KP Development Short Plat
1825 NE 38th Street
Level 1 Drainage Report & Preliminary Storm Report
9/20/2018
For:
Mr. Cameron Damskov
Damskov Construction, LLC
1940 124th Ave NE, Suite A107
Bellevue, WA 98005
By:
Preferred Engineering, LLC
11627 SE 58th Street
Bellevue, WA 98006
(206) 501-5708
- 2 -
Table of Contents
TASK 1 THROUGH 5 IS THE PROJECT OVERVIEW AND LEVEL 1 OFF-SITE ANALYSIS
TASK 1: DEFINING & MAPPING STUDY AREA: .......................................................................................... 3
TASK 2 : RESOURCE REVIEW ................................................................................................................... 6
TASK 3: FIELD INSPECTION .................................................................................................................... 10
TASK 4: DRAINAGE SYSTEM DESCRIPTION & PROBLEM DESCRIPTIONS .................................................. 11
TASK 5: MITIGATION OF EXISTING OR POTENTIAL PROBLEMS ............................................................... 25
APPENDIX .............................................................................................................................................. 26
A. CORE & SPECIAL REQUIREMENTS DISCUSSION
a. Flow Control Discussion and Calculations
b. Existing and Proposed Site Conditions Analysis Results Using KCRTS
c. Water Quality BMP – Bioswale Design
B. DOWNSTREAM ANALYSIS MAPPING
C. AS-BUILTS
D. RENTON BACKGROUND INFORMATION
E. BASIN DELINEATION MAPPING
F. HYDROLOGICAL CALCULATIONS USING KCRTS
- 3 -
The following report provides the Level 1 Downstream Analysis and preliminary TIR report (hereafter
called the drainage report) required for preliminary plat review, as well as additional discussion of the
City of Renton Core and Special Requirement requirements. This preliminary drainage report will be
used later for the development of the full TIR for final engineering plan submittal purpose. The
following report shall comply with the City of Renton Amendment to the King County Surface Water
Design Manual effective January 1, 2017. This project proposes more than 2,000 square feet of new
impervious surface and will result in more than 7,000 square feet or more of land disturbing activity.
Therefore is subject to the Full Drainage Review criteria and requires discussion of all nine core
requirements in Section 1.1.2.4 and the six special requirements in Section 1.3.
TASK 1: DEFINING & MAPPING STUDY AREA:
The proposed KP Development 8 lot short plat is located generally west of Lincoln Avenue NE and south
of NE 38th Street in parcel 334570-0220 in the north end of the City of Renton. (See Figure 1 map) The
existing use of the 1.46 acre lot is as a single family residence with mostly grass cover, trees and
blackberries. The proposed plat proposes to develop 8 single family lots within the R8 zone allowable
land use area. The current zoning to the north , east, west and south boundaries are all R-8 zoning.
Along the southwest property boundary is a SFH with it’s prior built access drive within the project
boundary. This project proposes to fix this issue by submitting a concurrent lot line adjustment and
keeping the existing access driveway. There are no creeks within the project and the southeast
boundary project has just constructed it’s storm and utilities for their development. The boundary to
the north has NE 38th Street on it’s boundary and on the other side are homes.
The proposed development will construct a stormwater vault treating water quality and detention,
roads, sidewalks, small house lots and try to retain the required trees required by the City of Renton
codes. This drainage report will comply with the 2017City of Renton Surface Water Design Manual .
Below are some researched mapping for the area that will assist with the storm design.
- 4 -
Figure 1; Vicinity Map
Project Site
- 5 -
Figure 2: Aerial Map
Project Site
- 6 -
TASK 2 : RESOURCE REVIEW
Resources reviewed include use of Renton existing and potential flooding and erosion data, as builts and
discussions with two neighboring property owners regarding proposed walls and the existing driveway.
The following resource review includes any basin plans (basin reconnaissance summary reports), FEMA
maps, sensitive areas folios, USDA sols reports, King County Soils Survey, wetland inventory maps,
Renton erosion maps, Renton landslide maps, and any Washington State Department of Ecology’s latest
Clean Water Act Section 303d list of polluted waters.
• Basin Reconnaissance Summary Reports: There exists a downstream trail with an uphill
ditch system that intercepts the runoff from the site. Ultimately, the Jones Avenue NE
discharges to a culvert near the unimproved NE 40th Street system and under the I405
WSDOT – culvert of May Creek system. May Creek ultimately discharges into Lake
Washington.
• FEMA Maps: There exists no floodway or floodplain areas on the project site according to
IMAP or FEMA Maps.
• Renton Flow Control Application Map: The project site will be designed as a Flood Problem
Flow Control Standard with duration matching forested historical conditions for the 2 year
through the 100 year return frequencies.
• Sensitive Areas Folios:
o Coal Mine Hazard: The project is not within the City of Renton Coal Mine Hazard
Area.
o Steep Slope Areas: The project site has some steep slopes and an actual steep slope
map has been produced (see appendix) based upon survey and engineering slope
analyses with better information than what is provided in the lidar generated
mapping by the County designated in the COR Maps application.
o Landslide Flooding Areas: There exists no known landslide area within the project.
A more specific analysis has been provided by the geotechnical engineer.
- 7 -
o Seismic Hazard Areas: There exists no seismic hazard area on the site, but nearby
adjacent sites has some seismic hazard areas.
o Erosion Hazard Area: The project site is an erosion hazard area.
o Wetland Areas: There is no SAO wetland in the project area.
o Liquidification Area: See Geotechnical report.
o Drainage Complaints: There have not been drainage complaints upstream of the
project area or within the project area. Runoff primarily drains into the May creek
system immediately downstream of the project site and within a ¼ mile of the
project site.
General Soils used for small site lot LID feasibility:
The project site is primarily AgC or Alderwood gravelly sandy loam with up to 8 to 15 percent slopes,
AgD, Alderwood gravelly sandy loam 15 to 20% slopes and AkF, Alderwood and Kitsap soils with very
steep slopes according to the USDA – NRCS soils report. AgC soils typically have very low water
capacities that are moderately well drained (about 2.5 inches) with very low to moderately low capacity
of it’s most limiting layer to trasmit water. Typically a gravelly ashy sandy loam layer is present from 0
to 7 inches with very low ability to transmit water through the soil. The same is typical for the other two
Alderwood type soils. (See soils report for a more site specific summary of the soils.) Based upon the
soils information and report, runoff from the site during construction and post construction will not be
very permeable. Therefore whole site infiltration facilities are not proposed for this project.
- 8 -
From US Web Soils Survey Mapping
From Rentonwa.gov: Existing critical areas-STEEP SLOPE AREAS
Project
Site
Project
Site
- 9 -
Project Contour Map
Project
site
- 10 -
TASK 3: FIELD INSPECTION
A field visit was conducted on August 2, 2018. The weather leading up to the visit was generally dry and
no rains occurred that day. Temperature on August 2 was high 70s and low 80s in the afternoon. Soils
on Lincoln Avenue NE were gravelly and dry. Onsite the underbrush provided shade and vegetation was
healthy and green. There was no apparent upstream issues discharging onto the site and no indications
of rills or erosion was evident in the street ditch system or from the construction uphill. The
downstream ditch system adjacent to the trail did not show any type of negative erosion in the ditch.
Slopes on the ditch were generally 2:1 to 1.25:1. We walked the path where it leveled off and
discharged runoff, if ever there is heavy runoff, over the trail and spreading through the vegetation in a
northwest direction. At the base of the hill is Jones Avenue NE ‘s storm ditch system that discharges
west towards May Creek. Underbrush through the hillside prior to entering Jones Avenue NE is
generally healthy and lush. Pockets of blackberries exist preventing safe traverse downhill.
- 11 -
TASK 4: DRAINAGE SYSTEM DESCRIPTION & PROBLEM
DESCRIPTIONS
Existing Drainage System Description:
The existing drainage from the project site receives approximately 1.826 acres of upstream area from
grass, the single family house and the new vault runoff with modeling as ‘fully forested’ for it’s pre-
existing condition. Slopes vary from 18 percent to 3 percent closer to NE 36th Street. Lincoln Avenue
NE, fronting the project site, currently drains downhill Lincoln Avenue NE without being diverted
towards NE 38th Street. Any offsite from the street shall be maintained and the landuse is the same
proposed as existing since the property uphill re asphalted the road fronting this project site. North of
NE 38th Street there is a drainage catch basin allowing runoff to enter as a closed conveyance system
and heads northward towards NE 44th Street.
Proposed Drainage System Description:
The proposed drainage system from the site shall not affect any offsite downstream system. The site
shall divert any upstream runoff by install a shallow swale in the back yard of three homes and it shall
sheet flow over to it’s current natural discharge location over towards the steep slope. The runoff from
onsite shall retain it’s current flowpath and will not be diverted by this proposed development. The on-
site storm management system proposes to utilize compost amended soils as well as a rain cistern type
system to comply with the small site lot LID BMP requirement due to the inability of the soil to infiltrate
or disperse into the soils. The onsite roads, roof runoff, sidewalks, grass and driveways will be collected
into a new tightlined system and discharge into a combined dead and live volume vault. The runoff from
the vault shall at minimum match up to the 100 year return event and be less than the historic landuse
full forested runoff.
Upstream Analysis:
(See section described under Core Requirement #2 later in this report.)
- 12 -
FIGURE 1: SOUTH VIEW ON LINCOLN AVENUE NE
(LOOKING UPHILL AT THE NEW CURB/GUTTER-AUG 2018)
- 13 -
FIGURE 2: LOOKING NORTH ON LINCOLN AVENUE NE.. TOWARDS NE 38TH STREET INTERSECTION
- 14 -
FIGURE 3: LOOKING WEST ON NE 38TH STREET AT THE INTERSECTION WITH LINCOLN AVE NE
- 15 -
FIGURE 4: ENTRANCE GATE (LOOKING WEST) TO WALKING TRAIL LEADING DOWN TO JONES AVENUE
- 16 -
FIGURE 5: WALKING TRAIL WITH 2.5’ DEEP DITCH ON UPHILL SIDE (TO THE LEFT SIDE IN PICTURE) ..THE
SOUTHWEST TRAIL (WALKING DOWNHILL) EVENTUALLY OUTLETS ONTO JONES ROAD.
- 17 -
FIGURE 5: HILL HAS A LOW POINT
- 18 -
Core Requirement #1: Discharge at the Natural Location:
The project discharges immediately downstream to the existing ditch system uphill of the access trail.
All storm water runoff from the site will not be diverted from the NE 38th Street system and it’s natural
discharge location downhill of the project site.
Core Requirement #2: Offsite Analysis:
Upstream Discussion: An upstream and downstream analysis is provided in the following:
Contributing upstream runoff areas to the site are primarily from vegetated backyard grassed, treed or
sfh runoff from the southwest and via a discharged storm pipe/vault immediately uphill from the site.
The slope of the upstream areas is generally medium sloped with 5 to 15% grades. Most of the potential
offsite runoff is from this uphill vault discharge point which has been designed to the most current 2 to
100 year matching of historically forested runoff criteria due to the erosion issues and potential
downstream flooding issues. A ditch currently receives runoff from onsite and is immediately downhill
of the project limits. (See appendix for the ¼ mile level 1 downstream analysis map.)
The upstream basin divide is west of NE 36th Street (west of Lincoln Ave NE) with a storm capture MH
just south of 3601 Lincoln Avenue NE (parcel 3345700230). All upstream runoff, west of Lincoln Avenue
NE, is primarily drained to this storm drainage structure and discharges downhill towards Jones Avenue
NE.
Downstream Discussion: The downstream analysis includes discharge westward via sheet flow and into
the trail ditch system located immediately to the west of the project parcel. A low point in the trail
mostly percs into the soils and sheet flows downhill in a westerly direction off the trail. During very
intense and long rainfall events there is a possibility that runoff may sheet flow over the trail or continue
down hill in a southwesterly direction. Ultimately both discharge locations are in the same basin in less
than ¼ mile downstream. At the base of Jones Avenue NE runoff flows north to a low spot
approximately 800 feet north and then westward into May Creek and through the I405 May Creek
bridge.
The study area aerial map (see Figure 2, page 5) is provided to better illustrate the route. A ¼ mile
downstream analysis flow direction and basin boundary limits figure is also provided in the appendix.
Data was primarily collected from a qualitative walk and the CorMaps GIS mapping system.
- 19 -
The following sections (Core Requirement #3 and #8) will further evaluate and analyze the full drainage
review with a final engineering TIR submittal to be provided during the final engineering/construction
document submittals. This preliminary analysis has determined that this plat, according to the 2017 City
of Renton Surface Water Design Manual Amendment to the 2016 King County Surface Water Design
Manual, shall treat for the new PGIS, grass and clean impervious areas with designs implementing what
is recommended by the geotechnical engineer.
- 20 -
¼ Mile Downstream Qualitative Analysis
ID STRUCTURE TYPE CONDITION NOTES, Slopes, Sizes Distance
D.S.
1 Grassed trail side ditch on the south
east side (uphill) of soft trail
OK structurally,
ditches have
vegetation in it.
Good condition. No signs of
erosion in the ditch. Varies
1-ft deep to 1.5 ft.
Approximately 5% to 1.0%
slope.
0 to 307 ft.
2 The ditch has a low point at 307 feet
downstream of the project discharge
point ‘start’. The ditch does not have
a culvert that crosses the trail and
apparently just ponds up until
overflow over the trail.
OK 0% slope at this location for
45’ to 60’ width. Trail path
acts like a level spreader in
this location and sheetflows
downhill. No indications
downhill of any erosion.
This runoff would occur
only during a high and long
duration rainfall event.
307 feet DS
3 Sheet flow for approximately 250
feet
OK, vegetation
present. No
apparent erosive
rills or ditches.
Slope is steep in the
beginning of the sheet flow
at steeper than 1:1 and
leveling out near Jones
Avenue NE.
557 feet DS
4 Wide roadside ditch along east side
of Jones Avenue NE
Mild grade ditch Slope downstream along
Jones Avenue NE is 1% less
and has potential for wetland
plants. Cannot see base of
ditch due to blackberries
present. Appears to be
wetland area to the east of
Jones Avenue NE. on parcel
3345700120
1327 feet DS
of discharge
point.
- 21 -
Core Requirement #3: Flow Control Facilities:
This project proposes a flow control live volume vault to hold and control runoff from the proposed
landuse site changes. Per discussions with the City of Renton Development Services reviewer and per
the COR Flow Control Application Map, the project will be designed utilizing the Flood Problem Flow
Control Standard which essentially provides flow control for duration matching forested (historical)
conditions for the 2 year through the 100 year return frequencies. The site and downstream flow path
has a type 2 drainage problem (erosion) and potentially a type 3 drainage problem with some potential
flooding along Jones Avenue NE possible. Please note regardless of the flow control facility specified for
this project, the Core Requirement #9 shall identify and provide on-site BMPs applied to the project site.
(See Task 5 and Appendix sections of this report for landuse, calculations and preliminary/achievable
design information related to the proposed stormwater vault and LID BMPs.)
Core Requirement #4: Conveyance System
This project shall analyze, design and construct the minimum level of protection necessary against
overtopping, flooding, erosion and structural failure for the new system. The system shall be piped and
fully contain the 25 year peak flow for the developed conditions for onsite tributary areas and existing
conditions for offsite tributary areas. Any overtopping onsite will not be allowed to aggravate any
erosion or steep slope hazards. This preliminary storm water report submittal does not provide for
calculations at this time. During the final engineering plans development, when actual storm invert
elevations are known, the necessary calculations shall be provided.
Core Requirement #5: Construction Stormwater Pollution Prevention
The project shall provide sediment and erosion controls to maximum extent practical to prevent
transporting sediment from the site. A final construction SWPP plan (CSWPP) shall include an erosion
control plan and SWPPPS (spill control plan) for permanent and temporary measures.
Core Requirement #6: Maintenance and Operations
The project shall design the combined water quality and detention vault to City requirements since
runoff from ROW streets shall drain to the vault. Since the facility shall be maintained by the City, an
access path shall be provided on top of the vault to allow for future maintenance. After the 2 year bond
has been released, the City shall maintain the facility.
- 22 -
Core Requirement #7: Financial Guarantees and Liability
A maintenance bond, assignment of funds or certified check shall be posted for 2 years. The bond shall
be 100 % of the amount calculated in the bond quantities worksheet to be reviewed and accepted by
the City during the final engineering construction drawings phase.
Core Requirement #8: Water Quality Facilities
The project shall design and construct a basic water quality treatment protection for the site since it is
only a residential plat development and is not within an aquifer protection area per the City of Renton
Cor maps data. The facility shall be sized and will treat the entire proposed pollution generating
impervious surfaces from the site (PGIS). The project proposes more than 5,000 sq-ft of PGIS and is not
exempt from water quality treatment.
Core Requirement #9: On-Site BMPs
Core requirement #9 is required since the project is not designing an infiltration facility for flow control
facility code compliance, nor can it be done on this site, and the project is over 2,000 sq-ft of new plus
replaced impervious surface to be created. Based upon the 2017 City of Renton Surface Water Design
Manual, section 1.2.9 (specifically section 1.2.9.3), onsite small sub-division BMPs will be applied as
detailed on Appendix C, Section C.2.1 with impervious surfaces :
• Full Dispersion: Not capable due to lack of land for each lot and the requirement to level
out the lots and roads for most of the sited. The use of one or two splash blocks may be
possible if there is a flowpath of 50-ft or more downstream. Also the presence of erosion
and steep slopes to the west prevents even more use of the splash blocks. Rock pads also
are prohibitive due to the long length of downstream flowpath required. The simple 10-ft
trench is also not possible due to the non-infiltrating nature of the underlying soils. If this
BMP was implemented, then water would just pond underneath within the rock voids. The
same issue exists for the sheet flow option due to the lack of downstream flowpath, steep
slopes and lack of native vegetation downstream possible for this development. Non of the
Table C.2.1.A BMPs and flowpaths are possible for this development and each lot.
• Full Infiltration: Per the recommendations provided by the geotechnical engineer, whereby
they determined infiltration is not feasible for the site, this project will not be able to use full
infiltration to comply with the onsite stormwater BMP requirement. The site cannot fully
and reliably infiltrate. The geotechnical evaluation and approval requirement is not met for
full infiltration and not required per the steep slopes and erosion hazards of the project site.
The project site has shallow depth of topsoil before encountering glacial till.
- 23 -
• Limited Infiltration: Per the recommendations provided by the geotechnical engineer,
whereby they determined infiltration is not feasible for the site, this project will not be able
to use limited infiltration to comply with the onsite stormwater BMP requirement either.
Soils are better suited for limited infiltration, but still not optimal due to steper slopes and
lack of proper setbacks available for each lot. Gravel filled trenches requirements are
required to be too large if utilized on each lot and given the lack of space for this type of
facility, it is not feasible. In addition, the use of drywells is similarly problematic since the
depth of available sandy loams is also limited.
• Basic Dispersion: Basic sheet flow is not possible since there lacks proper setbacks after
fitting any potential vegetated strip.
• Farmland Dispersion: N/A in Renton
• Bioretention: Lack of available area exists for the use of this BMP since this project would
discharge on adjacent slopes greater than 15% and also is in an erosion hazard area. Finally
if this BMP was used, the areas would be transportation safety issues since families may end
up in these vegetated depressions with required roadway setbacks. Lack of proper non-
glacial soils are also not present for this site.
• Permeable Pavement: Difficult for this project site due to presence of trees overhead and
also the steeper slopes present onsite.
• Rainwater Harvesting: Use of a couple cisterns per house may be possible for this project.
• Reduced Impervious Surface Credit: Not able to setup for this site since existing lots are
already small and reducing house sizes would greatly impact the feasibility for this project.
• Native Growth Retention Credit: The native growth retention credit is not
• Perforated Pipe Connection: This BMP is possible for each lot’s on site BMP sizing.
• Rain Gardens: Not applicable due to area infeasibility.
• Soil Amendment: Possible to be amended with front yard areas that may discharge to the
roadway drainage.
• Tree Retention Credit: Tree retention is proposed for this site with trees along the south
property line being saved and areas to be included in a LLA.
• Vegetated Roofs: Financially not viable for this small development.
- 24 -
Special Requirement #1: Other Adopted Area Specific Requirements
The proposed project’s drainage basin is within the Lake Washington WRIA 8 – Cedar Sammamish
Watershed that contains Lake Washington also. The City of Renton has adopted the WRIA 8 within it’s
Ordinance for protection Salmon and other wildlife draining to Lake Washington. Any and all
endangered species must comply with the WRIA 8 plan for this basin, which this project is within.
The project is located upstream of the May Creek Basin and is subject to the City of Renton’s May Creek
Basin Plan area.
Special Requirement #2: Flood Hazard Area Delineation
There exists no flood hazards within the project area or immediately downstream of this discharge
location. There is a mapped wetlands east of the Jones Avenue area that this project drains towards.
The runoff planned to be discharged to this site will not affect the wetland hydrology.
Special Requirement #3: Flood Protection Facilities
There exists no known flood protection facilities in this area, upstream, or downstream.
Special Requirement #4: Source Control
This project shall not contain any stored materials which may contaminate the land and runoff that may
infiltrate into the aquifer. No short or long term gasing trucks, containers, or other flammable or toxic
chemicals will be stored on-site without proper containment methodologies.
Special Requirement #5: Oil Control
Oil control is not necessary for this development since traffic through the intersection of SE 2nd Place
and Duvall Avenue SE does not exceed 1,000 ADT or more.
Special Requirement #6: Aquifer Protection Area
The proposed project is not in Renton’s Aquifer Protection Mapping. The drainage plans will conform to
Ordinance 4367 and Ordinance 4851.
- 25 -
TASK 5: MITIGATION OF EXISTING OR POTENTIAL
PROBLEMS
The proposed development will have little or no long term impact to the basin or downstream
system. The proposed combined water quality and detention vault to mitigate for fully
forested conditions will actually decrease the amount of runoff from the site since the site is
currently occupied by a single family house with impervious driveways and grass onsite . The
use of the onsite BMPs for flow control exemption compliance, per the 2017 Renton Surface
Water Design Manual, is complied with also and will further decrease the discharges.
Potential temporary problems may occur if the site is left opened up during heavy storm events
so erosion and sediment control BMPs must be used during construction if continuous rainfall is
expected or the site is left unattended to for long durations. A temporary erosion and
sedimentation control plan will be created during the final engineering design phase to
minimize transport of sediment laden runoff to the downstream system. During construction
the use of stabilized entrances, CB inserts to protect downstream inlets and slope/soils erosion
BMPs (silt fence, seeding, straw waddles, check dams, plastic covering on stockpiles, etc.) will
be utilized to reduce impacts to the downstream storm system and adjacent properties.
Projected Landuse Changes for Effective Impacted Areas:
Existing Landuse (currently SFH with driveways, but will be modeled as fully forested) = 61,777.7 sq-ft
(1.418 acres)
Proposed Landuse Totals = 1.418 acres
Pollution Generating Impervious Areas = 12,909.35 sq-ft (0.296 acres)
Proposed Building Areas = 12,718 sq-ft (0.292 acres)
Proposed Driveways Areas = 3,557 sq-ft (0.0817 acres)
Sidewalks (in street areas) = 1,722 sq-ft (0.0395 acres)
Sidewalks (private lots) = 729.6 sq-ft (0.0167 acres)
Grass = 30,156 sq-ft (0.6923 acres)
- 26 -
APPENDIX
- 27 -
UPSTREAM AREASFeet0100200
Feet050100
WWHM2012
PROJECT REPORT
DRAFTNE38th-v1 9/23/2018 1:29:01 PM Page 2
General Model Information
Project Name: NE38th-v1
Site Name: 38th Ave NE SP
Site Address: Lincoln & 38th
City:Renton
Report Date: 9/23/2018
Gage:Seatac
Data Start: 1948/10/01
Data End: 2009/09/30
Timestep: 15 Minute
Precip Scale: 1.00
Version Date: 2016/02/25
Version: 4.2.12
POC Thresholds
Low Flow Threshold for POC1: 50 Percent of the 2 Year
High Flow Threshold for POC1: 50 Year
DRAFTNE38th-v1 9/23/2018 1:29:01 PM Page 3
Landuse Basin Data
Predeveloped Land Use
Basin 1
Bypass:No
GroundWater:No
Pervious Land Use acre
C, Forest, Mod 1.418
Pervious Total 1.418
Impervious Land Use acre
Impervious Total 0
Basin Total 1.418
Element Flows To:
Surface Interflow Groundwater
DRAFTNE38th-v1 9/23/2018 1:29:01 PM Page 4
Mitigated Land Use
Basin 1
Bypass:No
GroundWater:No
Pervious Land Use acre
C, Lawn, Mod 0.6923
Pervious Total 0.6923
Impervious Land Use acre
ROADS MOD 0.296
ROOF TOPS FLAT 0.292
DRIVEWAYS MOD 0.0817
SIDEWALKS MOD 0.056
Impervious Total 0.7257
Basin Total 1.418
Element Flows To:
Surface Interflow Groundwater
Vault 1 Vault 1
DRAFTNE38th-v1 9/23/2018 1:29:01 PM Page 5
Routing Elements
Predeveloped Routing
DRAFTNE38th-v1 9/23/2018 1:29:01 PM Page 6
Mitigated Routing
Vault 1
Width:18 ft.
Length:102.6249318341 ft.
Depth:12 ft.
Discharge Structure
Riser Height:11 ft.
Riser Diameter:18 in.
Notch Type:Rectangular
Notch Width:0.010 ft.
Notch Height:1.816 ft.
Orifice 1 Diameter: 0.566 in. Elevation:0 ft.
Element Flows To:
Outlet 1 Outlet 2
Vault Hydraulic Table
Stage(feet) Area(ac.) Volume(ac-ft.) Discharge(cfs) Infilt(cfs)
0.0000 0.042 0.000 0.000 0.000
0.1333 0.042 0.005 0.003 0.000
0.2667 0.042 0.011 0.004 0.000
0.4000 0.042 0.017 0.005 0.000
0.5333 0.042 0.022 0.006 0.000
0.6667 0.042 0.028 0.007 0.000
0.8000 0.042 0.033 0.007 0.000
0.9333 0.042 0.039 0.008 0.000
1.0667 0.042 0.045 0.009 0.000
1.2000 0.042 0.050 0.009 0.000
1.3333 0.042 0.056 0.010 0.000
1.4667 0.042 0.062 0.010 0.000
1.6000 0.042 0.067 0.011 0.000
1.7333 0.042 0.073 0.011 0.000
1.8667 0.042 0.079 0.011 0.000
2.0000 0.042 0.084 0.012 0.000
2.1333 0.042 0.090 0.012 0.000
2.2667 0.042 0.096 0.013 0.000
2.4000 0.042 0.101 0.013 0.000
2.5333 0.042 0.107 0.013 0.000
2.6667 0.042 0.113 0.014 0.000
2.8000 0.042 0.118 0.014 0.000
2.9333 0.042 0.124 0.014 0.000
3.0667 0.042 0.130 0.015 0.000
3.2000 0.042 0.135 0.015 0.000
3.3333 0.042 0.141 0.015 0.000
3.4667 0.042 0.147 0.016 0.000
3.6000 0.042 0.152 0.016 0.000
3.7333 0.042 0.158 0.016 0.000
3.8667 0.042 0.164 0.017 0.000
4.0000 0.042 0.169 0.017 0.000
4.1333 0.042 0.175 0.017 0.000
4.2667 0.042 0.180 0.018 0.000
4.4000 0.042 0.186 0.018 0.000
4.5333 0.042 0.192 0.018 0.000
4.6667 0.042 0.197 0.018 0.000
4.8000 0.042 0.203 0.019 0.000
DRAFTNE38th-v1 9/23/2018 1:29:01 PM Page 7
4.9333 0.042 0.209 0.019 0.000
5.0667 0.042 0.214 0.019 0.000
5.2000 0.042 0.220 0.019 0.000
5.3333 0.042 0.226 0.020 0.000
5.4667 0.042 0.231 0.020 0.000
5.6000 0.042 0.237 0.020 0.000
5.7333 0.042 0.243 0.020 0.000
5.8667 0.042 0.248 0.021 0.000
6.0000 0.042 0.254 0.021 0.000
6.1333 0.042 0.260 0.021 0.000
6.2667 0.042 0.265 0.021 0.000
6.4000 0.042 0.271 0.022 0.000
6.5333 0.042 0.277 0.022 0.000
6.6667 0.042 0.282 0.022 0.000
6.8000 0.042 0.288 0.022 0.000
6.9333 0.042 0.294 0.022 0.000
7.0667 0.042 0.299 0.023 0.000
7.2000 0.042 0.305 0.023 0.000
7.3333 0.042 0.311 0.023 0.000
7.4667 0.042 0.316 0.023 0.000
7.6000 0.042 0.322 0.024 0.000
7.7333 0.042 0.327 0.024 0.000
7.8667 0.042 0.333 0.024 0.000
8.0000 0.042 0.339 0.024 0.000
8.1333 0.042 0.344 0.024 0.000
8.2667 0.042 0.350 0.025 0.000
8.4000 0.042 0.356 0.025 0.000
8.5333 0.042 0.361 0.025 0.000
8.6667 0.042 0.367 0.025 0.000
8.8000 0.042 0.373 0.025 0.000
8.9333 0.042 0.378 0.026 0.000
9.0667 0.042 0.384 0.026 0.000
9.2000 0.042 0.390 0.026 0.000
9.3333 0.042 0.395 0.028 0.000
9.4667 0.042 0.401 0.031 0.000
9.6000 0.042 0.407 0.035 0.000
9.7333 0.042 0.412 0.039 0.000
9.8667 0.042 0.418 0.043 0.000
10.000 0.042 0.424 0.048 0.000
10.133 0.042 0.429 0.052 0.000
10.267 0.042 0.435 0.057 0.000
10.400 0.042 0.441 0.063 0.000
10.533 0.042 0.446 0.070 0.000
10.667 0.042 0.452 0.091 0.000
10.800 0.042 0.458 0.100 0.000
10.933 0.042 0.463 0.110 0.000
11.067 0.042 0.469 0.388 0.000
11.200 0.042 0.475 1.519 0.000
11.333 0.042 0.480 2.997 0.000
11.467 0.042 0.486 4.441 0.000
11.600 0.042 0.491 5.516 0.000
11.733 0.042 0.497 6.129 0.000
11.867 0.042 0.503 6.713 0.000
12.000 0.042 0.508 7.202 0.000
12.133 0.042 0.514 7.660 0.000
12.267 0.000 0.000 8.092 0.000
DRAFTNE38th-v1 9/23/2018 1:29:02 PM Page 8
Analysis Results
POC 1
+ Predeveloped x Mitigated
Predeveloped Landuse Totals for POC #1
Total Pervious Area: 1.418
Total Impervious Area: 0
Mitigated Landuse Totals for POC #1
Total Pervious Area: 0.6923
Total Impervious Area: 0.7257
Flow Frequency Method: Log Pearson Type III 17B
Flow Frequency Return Periods for Predeveloped. POC #1
Return Period Flow(cfs)
2 year 0.042221
5 year 0.069183
10 year 0.086519
25 year 0.107141
50 year 0.121425
100 year 0.134767
Flow Frequency Return Periods for Mitigated. POC #1
Return Period Flow(cfs)
2 year 0.020693
5 year 0.028512
10 year 0.034673
25 year 0.043676
50 year 0.051339
100 year 0.059885
Annual Peaks
Annual Peaks for Predeveloped and Mitigated. POC #1
Year Predeveloped Mitigated
1949 0.049 0.017
1950 0.058 0.021
1951 0.092 0.051
1952 0.029 0.016
1953 0.023 0.020
1954 0.036 0.019
1955 0.057 0.019
1956 0.046 0.024
1957 0.037 0.019
1958 0.041 0.020
DRAFTNE38th-v1 9/23/2018 1:29:37 PM Page 9
1959 0.036 0.017
1960 0.064 0.026
1961 0.035 0.022
1962 0.022 0.015
1963 0.030 0.020
1964 0.042 0.021
1965 0.028 0.023
1966 0.027 0.019
1967 0.065 0.021
1968 0.036 0.019
1969 0.036 0.019
1970 0.029 0.020
1971 0.032 0.020
1972 0.070 0.026
1973 0.031 0.023
1974 0.034 0.020
1975 0.048 0.018
1976 0.034 0.019
1977 0.005 0.015
1978 0.029 0.021
1979 0.018 0.014
1980 0.082 0.044
1981 0.026 0.020
1982 0.053 0.024
1983 0.046 0.020
1984 0.028 0.016
1985 0.016 0.016
1986 0.072 0.022
1987 0.064 0.025
1988 0.025 0.017
1989 0.017 0.016
1990 0.153 0.026
1991 0.081 0.025
1992 0.033 0.022
1993 0.032 0.016
1994 0.011 0.014
1995 0.046 0.022
1996 0.107 0.034
1997 0.083 0.100
1998 0.020 0.016
1999 0.091 0.026
2000 0.032 0.020
2001 0.006 0.012
2002 0.037 0.023
2003 0.056 0.018
2004 0.060 0.030
2005 0.044 0.019
2006 0.050 0.024
2007 0.116 0.062
2008 0.141 0.037
2009 0.066 0.023
Ranked Annual Peaks
Ranked Annual Peaks for Predeveloped and Mitigated. POC #1
Rank Predeveloped Mitigated
1 0.1529 0.0998
2 0.1409 0.0620
3 0.1156 0.0512
DRAFTNE38th-v1 9/23/2018 1:29:37 PM Page 10
4 0.1071 0.0441
5 0.0922 0.0367
6 0.0906 0.0344
7 0.0826 0.0304
8 0.0824 0.0261
9 0.0811 0.0261
10 0.0723 0.0260
11 0.0700 0.0257
12 0.0657 0.0246
13 0.0648 0.0246
14 0.0639 0.0239
15 0.0636 0.0237
16 0.0595 0.0235
17 0.0577 0.0232
18 0.0574 0.0229
19 0.0557 0.0226
20 0.0535 0.0225
21 0.0497 0.0217
22 0.0486 0.0217
23 0.0479 0.0217
24 0.0463 0.0215
25 0.0462 0.0214
26 0.0457 0.0210
27 0.0442 0.0209
28 0.0424 0.0207
29 0.0414 0.0204
30 0.0373 0.0204
31 0.0373 0.0203
32 0.0365 0.0202
33 0.0359 0.0199
34 0.0355 0.0199
35 0.0355 0.0199
36 0.0350 0.0196
37 0.0344 0.0195
38 0.0342 0.0194
39 0.0331 0.0193
40 0.0323 0.0193
41 0.0322 0.0191
42 0.0322 0.0189
43 0.0310 0.0188
44 0.0299 0.0187
45 0.0289 0.0186
46 0.0289 0.0183
47 0.0285 0.0178
48 0.0282 0.0175
49 0.0275 0.0173
50 0.0271 0.0170
51 0.0259 0.0164
52 0.0252 0.0161
53 0.0234 0.0159
54 0.0218 0.0158
55 0.0202 0.0157
56 0.0175 0.0157
57 0.0167 0.0154
58 0.0164 0.0148
59 0.0109 0.0144
60 0.0058 0.0139
61 0.0050 0.0124
DRAFTNE38th-v1 9/23/2018 1:29:37 PM Page 11
DRAFTNE38th-v1 9/23/2018 1:29:37 PM Page 12
Duration Flows
The Facility PASSED
Flow(cfs) Predev Mit Percentage Pass/Fail
0.0211 17075 15659 91 Pass
0.0221 15488 11631 75 Pass
0.0231 14074 7982 56 Pass
0.0242 12797 5364 41 Pass
0.0252 11567 3771 32 Pass
0.0262 10521 2035 19 Pass
0.0272 9561 1672 17 Pass
0.0282 8750 1482 16 Pass
0.0292 8038 1392 17 Pass
0.0302 7343 1292 17 Pass
0.0312 6733 1201 17 Pass
0.0323 6192 1130 18 Pass
0.0333 5730 1053 18 Pass
0.0343 5309 948 17 Pass
0.0353 4924 847 17 Pass
0.0363 4569 730 15 Pass
0.0373 4235 640 15 Pass
0.0383 3951 569 14 Pass
0.0393 3645 474 13 Pass
0.0404 3388 394 11 Pass
0.0414 3133 362 11 Pass
0.0424 2915 322 11 Pass
0.0434 2706 297 10 Pass
0.0444 2490 279 11 Pass
0.0454 2314 265 11 Pass
0.0464 2136 252 11 Pass
0.0475 1972 240 12 Pass
0.0485 1825 229 12 Pass
0.0495 1702 217 12 Pass
0.0505 1577 206 13 Pass
0.0515 1443 191 13 Pass
0.0525 1325 184 13 Pass
0.0535 1232 177 14 Pass
0.0545 1147 163 14 Pass
0.0556 1083 151 13 Pass
0.0566 1020 139 13 Pass
0.0576 947 129 13 Pass
0.0586 885 123 13 Pass
0.0596 824 97 11 Pass
0.0606 760 75 9 Pass
0.0616 725 46 6 Pass
0.0627 674 40 5 Pass
0.0637 623 39 6 Pass
0.0647 589 37 6 Pass
0.0657 549 35 6 Pass
0.0667 506 33 6 Pass
0.0677 469 30 6 Pass
0.0687 427 28 6 Pass
0.0697 388 26 6 Pass
0.0708 356 26 7 Pass
0.0718 328 24 7 Pass
0.0728 298 24 8 Pass
0.0738 270 23 8 Pass
DRAFTNE38th-v1 9/23/2018 1:29:37 PM Page 13
0.0748 241 23 9 Pass
0.0758 218 22 10 Pass
0.0768 197 21 10 Pass
0.0779 173 21 12 Pass
0.0789 152 21 13 Pass
0.0799 130 21 16 Pass
0.0809 119 19 15 Pass
0.0819 104 19 18 Pass
0.0829 95 19 20 Pass
0.0839 83 18 21 Pass
0.0849 74 18 24 Pass
0.0860 69 17 24 Pass
0.0870 61 17 27 Pass
0.0880 53 16 30 Pass
0.0890 46 16 34 Pass
0.0900 39 15 38 Pass
0.0910 29 15 51 Pass
0.0920 25 14 56 Pass
0.0931 22 14 63 Pass
0.0941 20 13 65 Pass
0.0951 17 11 64 Pass
0.0961 14 11 78 Pass
0.0971 12 10 83 Pass
0.0981 8 8 100 Pass
0.0991 7 7 100 Pass
0.1001 7 0 0 Pass
0.1012 7 0 0 Pass
0.1022 6 0 0 Pass
0.1032 6 0 0 Pass
0.1042 6 0 0 Pass
0.1052 6 0 0 Pass
0.1062 6 0 0 Pass
0.1072 5 0 0 Pass
0.1083 5 0 0 Pass
0.1093 5 0 0 Pass
0.1103 5 0 0 Pass
0.1113 5 0 0 Pass
0.1123 5 0 0 Pass
0.1133 5 0 0 Pass
0.1143 4 0 0 Pass
0.1153 4 0 0 Pass
0.1164 3 0 0 Pass
0.1174 3 0 0 Pass
0.1184 3 0 0 Pass
0.1194 3 0 0 Pass
0.1204 3 0 0 Pass
0.1214 3 0 0 Pass
DRAFTNE38th-v1 9/23/2018 1:29:37 PM Page 14
Water Quality
Water Quality BMP Flow and Volume for POC #1
On-line facility volume: 0 acre-feet
On-line facility target flow: 0 cfs.
Adjusted for 15 min: 0 cfs.
Off-line facility target flow: 0 cfs.
Adjusted for 15 min: 0 cfs.
DRAFTNE38th-v1 9/23/2018 1:29:37 PM Page 15
LID Report
DRAFTNE38th-v1 9/23/2018 1:29:47 PM Page 16
Model Default Modifications
Total of 0 changes have been made.
PERLND Changes
No PERLND changes have been made.
IMPLND Changes
No IMPLND changes have been made.
DRAFTNE38th-v1 9/23/2018 1:29:47 PM Page 17
Appendix
Predeveloped Schematic
DRAFTNE38th-v1 9/23/2018 1:29:47 PM Page 18
Mitigated Schematic
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 19
Predeveloped UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 NE38th-v1.wdm
MESSU 25 PreNE38th-v1.MES
27 PreNE38th-v1.L61
28 PreNE38th-v1.L62
30 POCNE38th-v11.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
PERLND 11
COPY 501
DISPLY 1
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Basin 1 MAX 1 2 30 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
11 C, Forest, Mod 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
11 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
11 0 0 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 20
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
11 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
11 0 4.5 0.08 400 0.1 0.5 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
11 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
11 0.2 0.5 0.35 6 0.5 0.7
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
11 0 0 0 0 2.5 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
END GEN-INFO
*** Section IWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
END ACTIVITY
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
END PRINT-INFO
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
# - # CSNO RTOP VRS VNN RTLI ***
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
END IWAT-PARM2
IWAT-PARM3
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
END IWAT-STATE1
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 21
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
Basin 1***
PERLND 11 1.418 COPY 501 12
PERLND 11 1.418 COPY 501 13
******Routing******
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
in out ***
END GEN-INFO
*** Section RCHRES***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
END HYDR-PARM2
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
END HYDR-INIT
END RCHRES
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
END FTABLES
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 22
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 501 FLOW ENGL REPL
END EXT TARGETS
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
END MASS-LINK
END RUN
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 23
Mitigated UCI File
RUN
GLOBAL
WWHM4 model simulation
START 1948 10 01 END 2009 09 30
RUN INTERP OUTPUT LEVEL 3 0
RESUME 0 RUN 1 UNIT SYSTEM 1
END GLOBAL
FILES
<File> <Un#> <-----------File Name------------------------------>***
<-ID-> ***
WDM 26 NE38th-v1.wdm
MESSU 25 MitNE38th-v1.MES
27 MitNE38th-v1.L61
28 MitNE38th-v1.L62
30 POCNE38th-v11.dat
END FILES
OPN SEQUENCE
INGRP INDELT 00:15
PERLND 17
IMPLND 2
IMPLND 4
IMPLND 6
IMPLND 9
RCHRES 1
COPY 1
COPY 501
DISPLY 1
END INGRP
END OPN SEQUENCE
DISPLY
DISPLY-INFO1
# - #<----------Title----------->***TRAN PIVL DIG1 FIL1 PYR DIG2 FIL2 YRND
1 Vault 1 MAX 1 2 30 9
END DISPLY-INFO1
END DISPLY
COPY
TIMESERIES
# - # NPT NMN ***
1 1 1
501 1 1
END TIMESERIES
END COPY
GENER
OPCODE
# # OPCD ***
END OPCODE
PARM
# # K ***
END PARM
END GENER
PERLND
GEN-INFO
<PLS ><-------Name------->NBLKS Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
17 C, Lawn, Mod 1 1 1 1 27 0
END GEN-INFO
*** Section PWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC ***
17 0 0 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 24
PRINT-INFO
<PLS > ***************** Print-flags ***************************** PIVL PYR
# - # ATMP SNOW PWAT SED PST PWG PQAL MSTL PEST NITR PHOS TRAC *********
17 0 0 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
PWAT-PARM1
<PLS > PWATER variable monthly parameter value flags ***
# - # CSNO RTOP UZFG VCS VUZ VNN VIFW VIRC VLE INFC HWT ***
17 0 0 0 0 0 0 0 0 0 0 0
END PWAT-PARM1
PWAT-PARM2
<PLS > PWATER input info: Part 2 ***
# - # ***FOREST LZSN INFILT LSUR SLSUR KVARY AGWRC
17 0 4.5 0.03 400 0.1 0.5 0.996
END PWAT-PARM2
PWAT-PARM3
<PLS > PWATER input info: Part 3 ***
# - # ***PETMAX PETMIN INFEXP INFILD DEEPFR BASETP AGWETP
17 0 0 2 2 0 0 0
END PWAT-PARM3
PWAT-PARM4
<PLS > PWATER input info: Part 4 ***
# - # CEPSC UZSN NSUR INTFW IRC LZETP ***
17 0.1 0.25 0.25 6 0.5 0.25
END PWAT-PARM4
PWAT-STATE1
<PLS > *** Initial conditions at start of simulation
ran from 1990 to end of 1992 (pat 1-11-95) RUN 21 ***
# - # *** CEPS SURS UZS IFWS LZS AGWS GWVS
17 0 0 0 0 2.5 1 0
END PWAT-STATE1
END PERLND
IMPLND
GEN-INFO
<PLS ><-------Name-------> Unit-systems Printer ***
# - # User t-series Engl Metr ***
in out ***
2 ROADS/MOD 1 1 1 27 0
4 ROOF TOPS/FLAT 1 1 1 27 0
6 DRIVEWAYS/MOD 1 1 1 27 0
9 SIDEWALKS/MOD 1 1 1 27 0
END GEN-INFO
*** Section IWATER***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # ATMP SNOW IWAT SLD IWG IQAL ***
2 0 0 1 0 0 0
4 0 0 1 0 0 0
6 0 0 1 0 0 0
9 0 0 1 0 0 0
END ACTIVITY
PRINT-INFO
<ILS > ******** Print-flags ******** PIVL PYR
# - # ATMP SNOW IWAT SLD IWG IQAL *********
2 0 0 4 0 0 0 1 9
4 0 0 4 0 0 0 1 9
6 0 0 4 0 0 0 1 9
9 0 0 4 0 0 0 1 9
END PRINT-INFO
IWAT-PARM1
<PLS > IWATER variable monthly parameter value flags ***
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 25
# - # CSNO RTOP VRS VNN RTLI ***
2 0 0 0 0 0
4 0 0 0 0 0
6 0 0 0 0 0
9 0 0 0 0 0
END IWAT-PARM1
IWAT-PARM2
<PLS > IWATER input info: Part 2 ***
# - # *** LSUR SLSUR NSUR RETSC
2 400 0.05 0.1 0.08
4 400 0.01 0.1 0.1
6 400 0.05 0.1 0.08
9 400 0.05 0.1 0.08
END IWAT-PARM2
IWAT-PARM3
<PLS > IWATER input info: Part 3 ***
# - # ***PETMAX PETMIN
2 0 0
4 0 0
6 0 0
9 0 0
END IWAT-PARM3
IWAT-STATE1
<PLS > *** Initial conditions at start of simulation
# - # *** RETS SURS
2 0 0
4 0 0
6 0 0
9 0 0
END IWAT-STATE1
END IMPLND
SCHEMATIC
<-Source-> <--Area--> <-Target-> MBLK ***
<Name> # <-factor-> <Name> # Tbl# ***
Basin 1***
PERLND 17 0.6923 RCHRES 1 2
PERLND 17 0.6923 RCHRES 1 3
IMPLND 2 0.296 RCHRES 1 5
IMPLND 4 0.292 RCHRES 1 5
IMPLND 6 0.0817 RCHRES 1 5
IMPLND 9 0.056 RCHRES 1 5
******Routing******
PERLND 17 0.6923 COPY 1 12
IMPLND 2 0.296 COPY 1 15
IMPLND 4 0.292 COPY 1 15
IMPLND 6 0.0817 COPY 1 15
IMPLND 9 0.056 COPY 1 15
PERLND 17 0.6923 COPY 1 13
RCHRES 1 1 COPY 501 16
END SCHEMATIC
NETWORK
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
COPY 501 OUTPUT MEAN 1 1 48.4 DISPLY 1 INPUT TIMSER 1
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # #<-factor->strg <Name> # # <Name> # # ***
END NETWORK
RCHRES
GEN-INFO
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 26
RCHRES Name Nexits Unit Systems Printer ***
# - #<------------------><---> User T-series Engl Metr LKFG ***
in out ***
1 Vault 1 1 1 1 1 28 0 1
END GEN-INFO
*** Section RCHRES***
ACTIVITY
<PLS > ************* Active Sections *****************************
# - # HYFG ADFG CNFG HTFG SDFG GQFG OXFG NUFG PKFG PHFG ***
1 1 0 0 0 0 0 0 0 0 0
END ACTIVITY
PRINT-INFO
<PLS > ***************** Print-flags ******************* PIVL PYR
# - # HYDR ADCA CONS HEAT SED GQL OXRX NUTR PLNK PHCB PIVL PYR *********
1 4 0 0 0 0 0 0 0 0 0 1 9
END PRINT-INFO
HYDR-PARM1
RCHRES Flags for each HYDR Section ***
# - # VC A1 A2 A3 ODFVFG for each *** ODGTFG for each FUNCT for each
FG FG FG FG possible exit *** possible exit possible exit
* * * * * * * * * * * * * * ***
1 0 1 0 0 4 0 0 0 0 0 0 0 0 0 2 2 2 2 2
END HYDR-PARM1
HYDR-PARM2
# - # FTABNO LEN DELTH STCOR KS DB50 ***
<------><--------><--------><--------><--------><--------><--------> ***
1 1 0.02 0.0 0.0 0.5 0.0
END HYDR-PARM2
HYDR-INIT
RCHRES Initial conditions for each HYDR section ***
# - # *** VOL Initial value of COLIND Initial value of OUTDGT
*** ac-ft for each possible exit for each possible exit
<------><--------> <---><---><---><---><---> *** <---><---><---><---><--->
1 0 4.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
END HYDR-INIT
END RCHRES
SPEC-ACTIONS
END SPEC-ACTIONS
FTABLES
FTABLE 1
92 4
Depth Area Volume Outflow1 Velocity Travel Time***
(ft) (acres) (acre-ft) (cfs) (ft/sec) (Minutes)***
0.000000 0.042407 0.000000 0.000000
0.133333 0.042407 0.005654 0.003174
0.266667 0.042407 0.011309 0.004489
0.400000 0.042407 0.016963 0.005498
0.533333 0.042407 0.022617 0.006349
0.666667 0.042407 0.028271 0.007098
0.800000 0.042407 0.033926 0.007776
0.933333 0.042407 0.039580 0.008399
1.066667 0.042407 0.045234 0.008979
1.200000 0.042407 0.050888 0.009523
1.333333 0.042407 0.056543 0.010038
1.466667 0.042407 0.062197 0.010528
1.600000 0.042407 0.067851 0.010996
1.733333 0.042407 0.073505 0.011445
1.866667 0.042407 0.079160 0.011877
2.000000 0.042407 0.084814 0.012294
2.133333 0.042407 0.090468 0.012698
2.266667 0.042407 0.096123 0.013088
2.400000 0.042407 0.101777 0.013468
2.533333 0.042407 0.107431 0.013837
2.666667 0.042407 0.113085 0.014196
2.800000 0.042407 0.118740 0.014547
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 27
2.933333 0.042407 0.124394 0.014889
3.066667 0.042407 0.130048 0.015224
3.200000 0.042407 0.135702 0.015551
3.333333 0.042407 0.141357 0.015872
3.466667 0.042407 0.147011 0.016186
3.600000 0.042407 0.152665 0.016495
3.733333 0.042407 0.158319 0.016797
3.866667 0.042407 0.163974 0.017095
4.000000 0.042407 0.169628 0.017387
4.133333 0.042407 0.175282 0.017674
4.266667 0.042407 0.180937 0.017957
4.400000 0.042407 0.186591 0.018236
4.533333 0.042407 0.192245 0.018510
4.666667 0.042407 0.197899 0.018780
4.800000 0.042407 0.203554 0.019046
4.933333 0.042407 0.209208 0.019309
5.066667 0.042407 0.214862 0.019568
5.200000 0.042407 0.220516 0.019824
5.333333 0.042407 0.226171 0.020077
5.466667 0.042407 0.231825 0.020326
5.600000 0.042407 0.237479 0.020572
5.733333 0.042407 0.243133 0.020816
5.866667 0.042407 0.248788 0.021057
6.000000 0.042407 0.254442 0.021294
6.133333 0.042407 0.260096 0.021530
6.266667 0.042407 0.265751 0.021763
6.400000 0.042407 0.271405 0.021993
6.533333 0.042407 0.277059 0.022221
6.666667 0.042407 0.282713 0.022446
6.800000 0.042407 0.288368 0.022670
6.933333 0.042407 0.294022 0.022891
7.066667 0.042407 0.299676 0.023110
7.200000 0.042407 0.305330 0.023327
7.333333 0.042407 0.310985 0.023542
7.466667 0.042407 0.316639 0.023755
7.600000 0.042407 0.322293 0.023966
7.733333 0.042407 0.327947 0.024175
7.866667 0.042407 0.333602 0.024383
8.000000 0.042407 0.339256 0.024589
8.133333 0.042407 0.344910 0.024793
8.266667 0.042407 0.350565 0.024995
8.400000 0.042407 0.356219 0.025196
8.533333 0.042407 0.361873 0.025395
8.666667 0.042407 0.367527 0.025593
8.800000 0.042407 0.373182 0.025789
8.933333 0.042407 0.378836 0.025984
9.066667 0.042407 0.384490 0.026177
9.200000 0.042407 0.390144 0.026435
9.333333 0.042407 0.395799 0.028420
9.466667 0.042407 0.401453 0.031466
9.600000 0.042407 0.407107 0.035123
9.733333 0.042407 0.412761 0.039186
9.866667 0.042407 0.418416 0.043521
10.00000 0.042407 0.424070 0.048026
10.13333 0.042407 0.429724 0.052622
10.26667 0.042407 0.435378 0.057860
10.40000 0.042407 0.441033 0.063751
10.53333 0.042407 0.446687 0.069963
10.66667 0.042407 0.452341 0.091879
10.80000 0.042407 0.457996 0.100811
10.93333 0.042407 0.463650 0.110110
11.06667 0.042407 0.469304 0.388676
11.20000 0.042407 0.474958 1.519618
11.33333 0.042407 0.480613 2.997846
11.46667 0.042407 0.486267 4.441525
11.60000 0.042407 0.491921 5.516890
11.73333 0.042407 0.497575 6.129828
11.86667 0.042407 0.503230 6.713336
12.00000 0.042407 0.508884 7.202843
12.13333 0.042407 0.514538 7.660676
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 28
END FTABLE 1
END FTABLES
EXT SOURCES
<-Volume-> <Member> SsysSgap<--Mult-->Tran <-Target vols> <-Grp> <-Member-> ***
<Name> # <Name> # tem strg<-factor->strg <Name> # # <Name> # # ***
WDM 2 PREC ENGL 1 PERLND 1 999 EXTNL PREC
WDM 2 PREC ENGL 1 IMPLND 1 999 EXTNL PREC
WDM 1 EVAP ENGL 0.76 PERLND 1 999 EXTNL PETINP
WDM 1 EVAP ENGL 0.76 IMPLND 1 999 EXTNL PETINP
END EXT SOURCES
EXT TARGETS
<-Volume-> <-Grp> <-Member-><--Mult-->Tran <-Volume-> <Member> Tsys Tgap Amd ***
<Name> # <Name> # #<-factor->strg <Name> # <Name> tem strg strg***
RCHRES 1 HYDR RO 1 1 1 WDM 1000 FLOW ENGL REPL
RCHRES 1 HYDR STAGE 1 1 1 WDM 1001 STAG ENGL REPL
COPY 1 OUTPUT MEAN 1 1 48.4 WDM 701 FLOW ENGL REPL
COPY 501 OUTPUT MEAN 1 1 48.4 WDM 801 FLOW ENGL REPL
END EXT TARGETS
MASS-LINK
<Volume> <-Grp> <-Member-><--Mult--> <Target> <-Grp> <-Member->***
<Name> <Name> # #<-factor-> <Name> <Name> # #***
MASS-LINK 2
PERLND PWATER SURO 0.083333 RCHRES INFLOW IVOL
END MASS-LINK 2
MASS-LINK 3
PERLND PWATER IFWO 0.083333 RCHRES INFLOW IVOL
END MASS-LINK 3
MASS-LINK 5
IMPLND IWATER SURO 0.083333 RCHRES INFLOW IVOL
END MASS-LINK 5
MASS-LINK 12
PERLND PWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 12
MASS-LINK 13
PERLND PWATER IFWO 0.083333 COPY INPUT MEAN
END MASS-LINK 13
MASS-LINK 15
IMPLND IWATER SURO 0.083333 COPY INPUT MEAN
END MASS-LINK 15
MASS-LINK 16
RCHRES ROFLOW COPY INPUT MEAN
END MASS-LINK 16
END MASS-LINK
END RUN
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 29
Predeveloped HSPF Message File
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 30
Mitigated HSPF Message File
DRAFTNE38th-v1 9/23/2018 1:29:48 PM Page 31
Disclaimer
Legal Notice
This program and accompanying documentation are provided 'as-is' without warranty of any kind. The
entire risk regarding the performance and results of this program is assumed by End User. Clear
Creek Solutions Inc. and the governmental licensee or sublicensees disclaim all warranties, either
expressed or implied, including but not limited to implied warranties of program and accompanying
documentation. In no event shall Clear Creek Solutions Inc. be liable for any damages whatsoever
(including without limitation to damages for loss of business profits, loss of business information,
business interruption, and the like) arising out of the use of, or inability to use this program even
if Clear Creek Solutions Inc. or their authorized representatives have been advised of the
possibility of such damages. Software Copyright © by : Clear Creek Solutions, Inc. 2005-2018; All
Rights Reserved.
Clear Creek Solutions, Inc.
6200 Capitol Blvd. Ste F
Olympia, WA. 98501
Toll Free 1(866)943-0304
Local (360)943-0304
www.clearcreeksolutions.com