TRAFFIC SIGNAL PLAN - RRFB
FOR
UW MEDICINE - VALLEY MEDICAL CENTER
TALBOT ROAD TRAFFIC SIGNAL AND INTERSECTION IMR.POVEMENTS
EX - - - - -
3 S4 S1
2 S2
EX 5' F4
EX 1 1 '-
o
EX 5.5'
5.5'
10'
5 -
RIW - - - -
267 RIW
SEE SHEET TS1.01 I
I SOURCE LOCATION.
I I I I I I I I I I
I .I
SIGNAL CONSTRUCTION NOTES (THIS SHEET ONLY):
0 CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-21.10 AT STATION 07+43.0, 33.5' RT. FURNISH AND INSTALL BLACK FB
SIGNAL POLE (15-FT HEIGHT), BASE, AND CAP. INSTALL TWO 36 "x36" W 1 1-2 SIGNS, ONE 24 "x 12" W 16-7P(R) SIGN, ONE
24"x12" W16-7P L SIGN, ONE W1 1-501 SIGN, ONE CARMANAH TWO-SIDED WRAP AROUND RRFB UNIT WITH PEDSTRIAN
VERIFICATION LIG T , ONE CONTROLLER UNIT WITH CABINET AND ONE NEW POLARA MODEL X APS PUSHBUTTON ON THE SIGNAL
POLE. SEE POLE 1 DETAIL, SHEET 2.02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. PEDESTRIAN PUSHBUTTON
SHALL FACE NORTH PARALLEL TO CROSSWALK.
CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.11 AT STATION 07+37.0, 30.0' LT. FURNISH AND INSTALL BLACK FB
SIGNAL POLE (15-FT HEIGHT), BASE, AND CAP. INSTALL TWO 36"x36" W11-2 SIGNS, ONE 24"x12" W16-7P(R) SIGN, ONE
24"x12" W16-7P L SIGN, ONE W1 1-501 SIGN, ONE CARMANAH TWO-SIDED WRAP AROUND RRFB UNIT WITH PEDSTRIAN
VERIFICATION LIGHTS, AND ONE NEW POLARA IMODEL X APS PUSHBUTTON ON THE SIGNAL POLE. SEE POLE 2 DETAIL, SHEET
2.02 FOR CONFIGURATION OF SIGNS AND BEACONS ON THE POLE. PEDESTRIAN PUSHBUTTON SHALL FACE NORTH PARALLEL TO
CROSSWALK.
3 REMOVE EXISTING POLE AND EQUIPMENT. SALVAGE AND RETURN ALL TO THE CITY OF RENTON SIGNAL MAINTENANCE SHOP.
REMOVE FOUNDATION TO A MINIMUM 24" BELOW SURFACE GRADE. COMPACT VOID.
SIGNAL GENERAL NOTES
o f EX
- I
v �
o i 5.5' -
1. THIS PROJECT SHALL BE CONSTRUCTED PER 2016 WSDOT STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION,
CITY OF RENTON STANDARD PLANS (CURRENT EDITION), AND WSDOT STANDARD DETAILS (CURRENT EDITION). EACH OF THESE DOCUMENTS
SHALL BE CONSIDERED PART OF THIS CONTRACT.
2.
3. ALL TRAFFIC SIGNAL AND PEDESTRIAN HEADS AND PUSH BUTTONS SHALL BE SECURELY AND COMPLETELY COVERED WHILE NOT IN
OPERATION.
2. JUNCTION BOXES SHALL BE PLACED OUTSIDE OF PAVEMENT SURFACE AND WHEELCHAIR RAMPS UNLESS OTHERWISE INSTRUCTED BY THE
ENGINEER. ALL JUNCTION BOXES WITHIN THE PAR/SIDEWALK SHALL USE NON-SKID COVERS PER WSDOT GSP8.20.2(9-29.2(1)A).OPT 1.GR8.
3. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS AND THE CURRENT EDITION OF THE CITY OF RENTON STANDARD SPECIFICATIONS
AND DETAILS. THE CURRENT EDITION OF THE CITY OF RENTON STANDARD SPECIFICATIONS AND DETAILS SHALL BE CONSIDERED PART OF
THIS CONTRACT.
4. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY.
5. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE INSPECTOR FOR MATERIALS APPROVAL THREE WEEKS PRIOR TO REQUESTED APPROVAL
DATE.
6. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES
48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY
COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE.
8. EXISTING FEATURES TO REMAIN UNLESS OTHERWISE NOTED.
9. ALL CONDUCTORS FOR SIGNAL HEADS, LOOPS, PEDESTRIAN HEADS, PUSHBUTTONS, AND STREET LIGHTS SHALL BE LABELED IN EACH
JUNCTION BOX.
10. ALL SIGNALIZED CROSSWALKS SHALL BE OPERATIONAL AT ALL TIMES UNLESS FLAGGERS/POLICE ARE PRESENT TO ASSIST PEDESTRIANS.
11. SALVAGE REMOVED SIGNAL EQUIPMENT TO THE CITY AS REQUESTED, INCLUDING TRAFFIC SIGNAL HEADS, TRAFFIC SIGNAL CONTROLLER
CABINET, MAST ARM STREET NAME SIGNS, AND OTHER ITEMS AS REQUESTED. CONTRACTOR SHALL DISPOSE OF ITEMS NOT DESIRED BY THE
CITY.
12. CONTRACTOR SHALL PROVIDE TENW WITH REDLINE MARKUPS SHOWING ANY AND ALL CHANGES FROM THESE APPROVED PLANS FOLLOWING
CONSTRUCTION.
13. SIGNAL POLE BASE PLATES AND FACE OF PUSHBUTTONS SHALL ALIGN WITH THE BEARING OF THE CROSSWALK IT SERVES. FAILURE TO
ORIENT POLES/BASE PLATES WITH THE CROSSWALK WILL REQUIRE THE FOUNDATION TO BE REMOVED AND RE -POURED BY THE CONTRACTOR.
SEE SIGNAL POLE PLACEMENT DETAIL SHEET TS2.02.
14. CONTRACTOR SHALL CONFIRM PREFERRED TRENCHING/BORING METHOD WITH CITY OF RENTON PRIOR TO BEGINNING CONSTRUCTION.
15. TRAFFIC SIGNAL, ILLUMINATION AND INTERCONNECT CONDUIT SHALL BE PLACED SUCH THAT IT WILL NOT CONFLICT WITH FUTURE STREET TREE
OR STRUCTURE INSTALLATIONS. VERIFY CONDUIT PLACEMENT WITH ENGINEER PRIOR TO BEGINNING CONSTRUCTION.
IPTENW
Transportation Engineering Northwest
Transportation Planning I Design I Traffic Impact & Operations
PO Box 65254, Seattle, WA 98155 1 Office (206) 361-7333
Project Contact: Chris Bicket, P.E.
Phone: 425-250-5002
"ER••T: B
•oF wAj
o:14
6'1STE9�P�
ONAL•�
07/18/2=
_5
23 10' -
1------ 5'------ -
F1 - - -
I RAW -
S1
S3
I
I�
:EX::jDEWALK I
TOOT R- S
-
-EXR/W
_ I
EX 5' SIDEWALK
RIW
SIGNAL WIRING SCHEDULE
RACEWAY
CONDUIT
SIZE
FLASH
PPB C
BEACON
PWR
#8
EQUIP,
GRND.
*
PULL
WIRE
CONDUIT
FILL
ALLOW.
FILL
NEW
NO.
22
2" SCH40 PVC
1
1
0.28
0.890
2" SCH80 PVC
1
1
0.28
0.890
23
2" SCH80 PVC SPARE
1
---
0.890
24
2" SCH80 PVC
1
2
1
0.45
0.890
2" SCH80 PVC
2
1
0.17
0.890
25
2" SCH80 PVC SPARE
1
---
0.890
26
2" SCH40 PVC
2
1
0.17
0.890
*EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR LARGER THAN THE
LARGEST WIRE SIZE IN THE CONDUIT.
Z
10 40
0 20 60
SCALE IN FEET
SIGNAL DISPLAYS
EL] ELI]
RECTANGULAR RAPID
FLASHING BEACON
NEW: F1,172,F3,F4
ALL NEW DISPLAYS SHALL BE LED.
SIGNAL LEGEND
(THIS
SHEET ONLY)
NEW
DESCRIPTION
O
SIGNAL POLE TYPE FB
H
POLE MOUNTED SIGN
©
POLE MOUNTED
CONTROLLER CABINET
OCONSTRUCTION
NOTE
®
SIGNAL POLE NUMBER
NEW SIGN NOTES (THIS SHEET ONLY)
S1 INSTALL ONE (1) 36"x36" W1 1-2 SIGN.
INSTALL ONE (1) 24"x 12" W 16-7P(L) SUPPLEMENTAL PLAQUE BENEATH
S2 W 1 1-2 SIGN.
S3
INSTALL
ONE
(1) 24"x 12" W 16-7P(R) SUPPLEMENTAL PLAQUE BENEATH
W 1 1-2
SIGN.
S4
INSTALL
ONE
(1) 12 "x 12" W 1 1-501 SIGN ABOVE PUSHBUTTON.
SIGN LEGEND
W 16-7P(L)
<
24"x12"
>
S2
W11-2
36 "x36"
W 16-7P(R)
S1
24"x12"
S3
•
W11-501
CROSS TRAFFIC
12 "x 12"
MAY NOT STOP
S4
USE CAUTION
WHEN CROSSING
AFFIX R10-25 (9"X12"
PER MUTCD) PLAQUE TO
PEDESTRIAN PUSHBUTTON
ASSEMBLIES
PUSH
POLARA MODEL X: 2 CT
BUTTON TO
TURN ON
WARNING
BACKGROUND : YELLOW
LIGHTS
TEXT/SYMBOL : BLACK
W 16-7P SIGNS
SHALL BE FLOURESCENT
YELLOW -GREEN
WITH BLACK SYMBOLS
AND BORDER.
W 1 1-2 SIGN SHALL BE FLOURESCENT
YELLOW -GREEN
WITH BLACK SYMBOLS
AND BORDER.
SEE POLE DETAILS,
SHEET TS-2.02 FOR
ADDITIONAL SIGNING REQUIREMENTS.
T-3991 010
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION OPERATION (Di
cbarnes 09/19/2018
SURVEYED:
SCALE:
VERTICAL: AD
HORIZONTAL: NAD 193/183/1 991
DATUM
A&W& C TY OF
vRRENTON
•
Planning/Building/Public Works Dept.
TRAFFIC SIGNAL PLAN - RRFB
UW MEDICINE -VALLEY MEDICAL CENTER
TALBOT ROAD INTERSECTION UPGRADES
400 SOUTH 43RD STREET
RENTON, WA 98055
DATE:
7/18/18
DESIGNED: J LS
FIELDBOOK:
PAGE:
DRAWN: JLS
ONE INCH
DRAWING NO:
TS2. 1
CHECKED:
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
NO.
REVISION
BY
DATE
APPR
APPROVED:
SHEET: 1 O OF: 1 7
00
M
O
O
Cfl
T
Q
J
N
O
L0
O
0
(0
T
7
C/)
z
Lu
2
Lu
O
z
O_
U
Lu
C/)
Lu
z
0
z
Q
J
Q
z
0
C/)
U_
IL
IL
Q
0
Q
O
O
In
J
Q
L L1
z
L L1
U
J
Q
U_
0
L L1
G
J
>