HomeMy WebLinkAboutMFP18002719DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP18002719
IVR Number: 18002719
Permit Informaon
Permit Name:Comcast Cable Franchise Permit
Address/Locaon :05/21/2018Application Date:3123059032Parcel Number:4000 EAST VALLEY RD
Permit Type:05/25/2018Issue Date:Franchise
Permit Work Class:05/25/2019Expiration Date:Minor Utility
Job Number:256918Franchise Type:Cable
Description:PRE CONSTRUCTION MEETING REQUIRED
APPROVED WITH COMMENTS OR REDLINES
Directional Drill 619' in the ROW. place two 2" SCH conduits. Place .875 coax cable. Place 2 new vaults. City of Renton
requests an additional conduit for the city be placed at the time of the crossing. Pothole all existing utilities.
Restoration per City of Renton standards. Restoration for this permit will need to take place at night.
Contacts
Name Address PhoneTypeBilling
Comcast Cable Communication
Management & Comcast Cable
B: (215) 665-1700Applicant
Tom Donnelly
Comcast Business Communications
1701 Jfk Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Scott Nall
SEFNCO Communications Inc
2904 4th Ave NE
Puyallup, WA 98372
B: (877) 385-2903
C: (253) 444-9057
Contractor
Business License Number: BL.041108Construction Contractor: SEFNCCI850QD
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
Specialized
Billing
X
General Condions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
MFP18002719Justin Johnson5-25-2018City of Renton Requests an additional conduit for the city be placed atthe time of the crossing.Restoration for this permit will need to take place at nightScott Warlick5/25/2018
MFP18002719Justin Johnson5-25-2018Restoration for this work will need to happen at night - 8:00 pm to 6:00 am.Monday through Friday
NESWSEFNCOCOMMUNICATIONSSOWSOWJT#256918FILE NAME:256918_DETAILED SOWDATE:CREATED 9/25/17PAGE:1 of 5ENGINEERED FOR:Not to scale. Do not use for locating.Verification of all utilities is the contractors responsibility. WA Dig line can be reached by dialing 811, WA law requires a 48 hour notice prior to digging.SERVICE KING JOB#:4000 E VALLEY RDRENTON, WA 98057CONTACT PERSON:SEFNCO COMMUNICATIONSKYARA SCHROEDER4610 TACOMA AVE.SUMNER, WA 98390Office (253) 299-8565Mobile (253) 405-5304KSCHROEDER@SEFNCO.COMSECTION INDEX:1 – COVER SHEET/ PROJECT LOCATION2 – OVERVIEW RENTON3 – DETAILED VIEW (ROW)4 – DETAILED VIEW (PRIVATE)COMCAST COMMUNICATIONS LLCKYLE KINNEY410 VALLEY AVE BLDG C ST 12PUYALLUP, WA 98371OFFICE(253) 864-4281MOBILE(206) 510-4222KYLE_KINNEY@comcast.comPROJECT TOTALSINTERIOR CONDUIT/COAXNEW PRIVATE UNDERGROUNDNEW ROW UNDERGROUNDNEW OVERLASH25'30'500'0TOTAL FOOTAGE555'RISER0PROJECT SCOPE:COMCAST PURPOSES TO TIE INTO EXISTING SYSTEM AND BORE ~500' AND PLACE 2 (2") SCH 40 CONDUITS IN ROW; PLACE 2 NEW VAULTS; BORE ~30' AND PLACE 1 (2") SCH 40 CONDUIT TO BUILDING; CORE DRILL AND OVERSET WITH LB; RUN ~25' OF COAX TO UTILITY CLOSET. 256918253‐293‐3838MFP18002719
Kyara SchroederPrepared By:REV 1Date:2 OF 5PROJECT SCOPE:COMCAST PURPOSES TO TIE INTO EXISTING SYSTEM AND BORE ~500' AND PLACE 2 (2") SCH 40 CONDUITS IN ROW; PLACE 2 NEW VAULTS; BORE ~30' AND PLACE 1 (2") SCH 40 CONDUIT TO BUILDING; CORE DRILL AND OVERSET WITH LB; RUN ~25' OF COAX TO UTILITY CLOSET. SMBKYLE KINNEY9/25/17OVERVIEW256918SERVICE KING4000 E VALLEY RDRENTON, WA 98057NESWSEFNCOCOMMUNICATIONSSYMBOL KEYNEW COMCAST VAULT/PEDNEW UNDERGROUND (BORE/TRENCH) UTILITY/DATA AREAEXISTING COMCAST VAULT/PEDLOT LINES/EDGE OF ROWNEW INTERIOR/EXTERIOR COAX2" CORE DRILL W/ LB & SEALANTUC0160'340'UC1SERVICED UNITS30'8'125'DRILL CREW SET UP LOCATIONDRILL CREW SET UP LOCATIONDIRECTIONAL DRILL @ 36" MIN;PLACE 2 - 2" PIPE;PLACE COAX CABLEDIRECTIONAL DRILL @ 36" MIN;PLACE 2 - 2" PIPE;PLACE COAX CABLEDIRECTIONAL DRILL @ 36" MIN;PLACE 1 - 2" PIPE;PLACE COAX CABLEPLACE EXTERIOR CONDUIT ON SIDE OF BUILDING; CORE DRILL 2" AND SEAL WITH LBBRING COAX DROP THROUGH DROP CEILING AND INTO UTILITY CLOSETMFP18002719
Kyara SchroederPrepared By:REV 1Date:3 OF 5SMBDETAILED VIEWNESWSEFNCOCOMMUNICATIONSKYLE KINNEY9/25/17256918SERVICE KING4000 E VALLEY RDRENTON, WA 98057SYMBOL KEYNEW COMCAST VAULT/PEDNEW UNDERGROUND (BORE/TRENCH) UTILITY/DATA AREAR 25POLE RISEREXISTING COMCAST VAULT/PEDNEW OVERLASHEXISTING UNDERGROUNDNEW INTERIOR/EXTERIOR COAX12"X18" LOCK BOX 2" CORE DRILL W/ LB & SEALANTUTILITY POLEUC1SERVICED UNITSTIE IN POINTBORE 2 (2") SCH 40 CONDUITSW 41ST STSW 41ST ST AND E VALLEYBORE 2 (2") SCH 40 CONDUITE VALLEY RDBORE 1 (2") SCH 40 CONDUITCORE DRILL 1(2") AND OVERSET WITH LBBORE 2 (2") SCH 40 CONDUITPLACE NEW VAULTPLACE NEW VAULTMFP18002719
KyaraSchroederPrepared By:REV 1Date:4 OF 5SMBDETAILED VIEWNESWSEFNCOCOMMUNICATIONSKYLE KINNEY9/25/17256918SERVICE KING4000 E VALLEY RDRENTON, WA 98057SYMBOL KEYNEW COMCAST VAULT/PEDNEW UNDERGROUND (BORE/TRENCH) UTILITY/DATA AREAR 25POLE RISEREXISTING COMCAST VAULT/PEDNEW OVERLASHEXISTING UNDERGROUNDNEW INTERIOR/EXTERIOR COAX12"X18" LOCK BOX 2" CORE DRILL W/ LB & SEALANTUTILITY POLEUC1SERVICED UNITSFIRE PENETRATE AND CON’T DROP ALONG CEILINGNORTH END OF SERVICE REPAIR SHOPFROM CEILING DROP INTO UC AND LEAVE 5' COILEDUC OF SERVICE KINGFACING WEST INSIDE UCRUN COAX INTO HALLWAY MFP18002719