FRAME AND VANED GRATE
5
I.
OR 12"
ONE #3 BARR HOOP FOR 6" HEIGHT
TWO #3 BAR HOOPS FOR 12" HEIGHT
RECTANGULAR ADJUSTMENT SECTION
2N0�01 rS�FA16
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCEDOR
12"
PLAIN CONCRETE
ALL METAL PIPE
15"
CPSSP*
12"
(STD. SPEC. 9-05.20)
SOLID WALL PVC
15"
(STD. SPEC. 9-05.12(1))
PROFILE WALL PVC
15"
(STD. SPEC. 9-05.12(2))
* CORRUGATED POLYETHYLENE
STORM SEWER PIPE
�6) NOTES
1. As acceptable altematives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
a wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
v PRECAST BASE SECTION. Wire mesh shall not be placed in the
#3 BAR EACH CORNER knockouts.
#3 BAR EACH SIDE
#3 BAR EACH WAY
PRECAST BASE SECTION
#3 BAR EACH CORNER
18• MIN
#3 BAR HOOP
2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
n + PUBLIC WORKS CATCH BASIN TYPE 1 STD. PLAN - 200.00
�FN COS DEPARTMENT
MARCH 2O08
RENE
Nonni
r
0
FRAME AND VANED GRATE
CLEAN SURFACE AND BOTTOM AREA.
PROVIDE UNIFORM CONTACT.
THE SURFACE AREA OF THE BASE SECTION MUST
BE GROUTED TO THE BOTTOM AREA OF THE
ADJUSTMENT SECTION.
BASE SECTION
/ SEE NOTE 4
NOTES
1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT,
GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISI IED, AND UNTIL PERMISSION TI IEREAFTER IS GIVEN BY
THE ENGINEER TO GROUT IN PLACE IN ACCORDANCE WITH APWA STANDARD SPECIFICATION 7-05.3.
2, SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED,
3. A CONTINUOUS LAYER. OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT.
4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR %z BOND,
5, ADJUSTMENT SECTION SHALL BE GROUTED WATER'flGl IT TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH NONSHRINK GROU t
3. GROUTING BETWEEN AUJUSI MEN I SEC I ION SHALL BE WATER TIGHT.
7. GROUT IS TO BE NON -SHRINK TYPE GROUT MEETING THE REQUIREMENTS OF ASTM 157 PER APWA STANDARD SPECIFICATION 9-20.3 FOR
MAXIMI_IM PERCENT DRY SHRINKAGE. THE MINIMUM COMPRFSSIVF STRFNGTH SHAI I BF 4,000 PSI AT 7 DAY PER APWA STANDARD
SPECIFICATION 9-20.3
B. PICK / LIFTING HOLES AN E 1 O BE GROU I I-D WA-1 HR I IGH 1.
PUBLIC WORKS GATCH GAG®H LUSTALLATION
DEPARTMENT
STD. PLAN -- 202.00
MARCH 2O08
BOLT -DOWN HOLE (TYP.)
- 5/8" - 11 NC, SEE
DETAIL & NOTE 2
O
TOP
SECTION O
NOTES
1 This frame is designed to accommodate 20" x 24" grates or
covers
2. Provide two holes in the frame that are vertically aligned with t
he grate or cover slots. Tap each hole to accept
a 5/8" - 11 NC x 2" alien head cap screw.
Location of bolt down holes varies among different
manufacturers.
3. Refer to Standard Specification 9-05.15(2) for additional
requirements.
RECESSED ALLEN
HEAD CAP SCREW
7/8"_ I 118" 5/6" - 11 NC x 2"
3/4• GRATE
ISOMETRIC VIEW
N a
e
a FRAME
2 112
SECTION
BOLT -DOWN DETAIL
DETAIL O SEENOTE2
�ZY o STD. PLAN - 204.00
A PUBLIC WORKS RECTANGULAR FRAME
DEPARTMENT
'f'�•N,tp MARCH 2O08
l
I'- 4' 2-7"MAX . MIN. 5'-D" CLEAR WIDTW .
VARIES IL�� VARIES
- I C TO 17 FACE of I O TO 17 I EDGE OF
f I SHOULDER CURB
I - ... - OR TURNOUT l�
I I
�- - - - - -I MUULfT' UN PEDE5TAL
PROVIDED WITH N.D.C.
-i E"U. UNIT.
TYPE OF
- - - - }' SUPPORT R CURB
I VARIES (TYPE
- - - - VARIES)
PLAKITIIJG 5f21NG WIOTW
D TO VARIABLE
ANCHOR 50)L-T
PATTE2iJ PER N.O. 3/6" X FULL DEPT 4
3/8' x FULL DEPTH C-E5.0 PEDESTAL F)CPANsiom JOII�Jr.
EXPAL1510N JOINT TEMPLATE.
WAL fC
�•�; ♦• 7: �r�: ��f: ram:.
F20KF VIEW SIDE VIEW
NUTE5
1.IN5TALL.ATION OF N.D.C:E.U. INCLUOIHG
CONSTIZUTION OF 5E WILL 8>= pUNE
5Y U,5. P05TAL 5E9_VI(_c.
NEIGN6URu000 DELIVERY AME)
COLLF-C-171M SOX UNIT
U.S.P.O. Neighborhood Delivery and
Collection Box Unit (Mailbox) Installation
O�
ADOPTED
Ufa
CITY OF RENTON
_ +
STANDARD PLANS
LST DATE:1-Aug-87
DWG NAME: HR-06 SP PAGE: H026
� LAMES
Encompass ��°FWAs0 V1,
�I�
�00 .A
ENGINEERING & SURVEYING UZ
Western Washington Division 4
165 NE Juniper Street, Suite 201 Is Issaouah, WA 98027 is Phone: (425) 392-0250 ■ Fax: (425) 391-3055 p R 38285
Eastern Washington Division, ISTEg�
407 Swiftwater Blvd. ■ Cie Elum, WA 98922 ■ Phone: (509) 674-7433 ■ Fax: (509) 674-7419 Sj0NAL
TYPE OF
SUPPORT
VARIES
AT EDGE OF SHOULDER BEHIND CURB
MAILBOX PLACEMENT SECTIONS
Y - r O.C. MIN
POST TO Pogr
, I
NEWSPAPER BOX
(SEE NOTE 3)
ANTI- TWIST �
$HE ", ATE 7p 1 F'I II
sTEELP03T WOOD POST
OPTION OPTION
TYPE 1 SUPPORT
MAILBOX SIZE 1, 1A, OR 2 (TYP.)
(2 CLAMPS PER BOX)
S MIN.
BETWEEN
MAILBOXES
MAILBOX SPACING DETAIL
VARIES NOTES:
0 TO tr 1. An ad ustable platform may be used in lieu of the platform design shown on
SACK OF thisplan. Adjustable latfarrns must fit the brackedesi n shown on this Ian.
SIDEWALK Brakets are requiredf or all single post installations. Field drilling may be
required.
2. A Type 2 support is required when 2 or more mailboxes are to be installed on
one support. A maximum of 5 mailboxes may be installed on a Type 2 sup-
port. See Std. Spec. 9.32.7.
>n TYPE OF 3. Attach a newspaper box to a steel post with two 1 7/8" Muffler Clamps spaced
SUPPORT 4" apart Field drill 7t16" holes in the newspaper box to fit. Use 2 1/2" . 114"
IH VARIES lag bolts to attach newspaper boxes to wood posts. Newspaper boxes must
SIDEWALK
not extend beyond the front of the mailbox when the mailbox door is closed.
4. Spacing of mailbox mounting holes varies among manufacturers. Attachment
of the mailbox to the platform may require drilling additional holes through the
mailbox to fit the platform.
5. Center the mailbox on the platform to ensure space for the mailbox door to
open and to allow space for installing the fasteners.
BEHIND SIDEWALK 6. A socket and wedge anchoring system may be substituted in lieu of the anti -
twist plate assembly for single steel posts shown on this plan. The socket and
wedge anchoring system shall meet NCHRP 350 Crash test criteria. Anti -twist
plates are not required for wood post installations.
INSTALL SNOW GUARD WHEN
SPECIFIED IN CONTRACT
(SEE DETAIL SHEET 3)
U.S.
lu MA L MAIL
w
NEWSPAPER BOX
(SEE NDTE 3)
'k ON TAS#.
- MULTIPLE MAILBOX R���
SUPPORT (SEE NOTE 2) �`, 5
9 �
Nil o,A 4p zrecl �,o
c� CI STEa ♦�
�•r10NAL 8�6
EXPIRES MAY 16, Y003
MAILBOX
INSTALLATION
TYPE 1 8r TYPE 2
(PROPRIETARY DESIGN SHOWN) STANDARD PLAN H-12
TYPE 2 SUPPORT sr1EEr 1 of 3 sNEErs
ADOPTED
nTM GtitY O� CITY OF RENTON
S STANDARD PLANS
dam rrY VI. I"srrUrlw p
mrr Ixrlsls '�Q�-•N,O.$ LAST DATE: 05109/2002
SP PAGE H027
Iv 5 REVISED DITCH STORMDRAIN BCS 11/27/17 TJR
SURVEYED: SCALE:
VERTICAL: NAVD 1988
n r HORIZONTAL: NAD 1983/1991
4 TAPER FRONTAGE CURB/ MOVE SS BCS 1/17/1 TJR DESIGNED: 1 =20
3 REVISED PER CITY REVIEW BCS 4/20/17 NEM TJR
2 REVISED PER CITY REVIEW BCS 3/20/17 TJR DROWN` BCS
1 REVISED PER CITY REVIEW / ADD VAULT BCS 2/16/17 TJR CHECKED: ONE INCH DATUM
TJR AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
TJR
1
A
TOP
24•
7 OR 8 EQUAL SPACES
M
Iri -DIRECTION OF FLOW
T__
SECTION O
SLOT - SEE DETAIL
AND NOTE 1
SECTION BO
1/2
1 114•
5/8'
BOLT -DOWN SLOT DETAIL
SEE NOTE 1
NOTES
I Provide two slots in the grate that are vertically aligned
with the holes in the frame. Location of bolt -down slots
varies among different manufacturers.
ISOMETRIC 2. Refer to Standard Specification 9-05.15(2) for additional
requirements.
3. Unless otherwise specified, vaned grates shall be used with standard frame
in the travel way, gutter or shoulder. vaned grates shall not be located
within crossroads. Use vaned grates along rolled curbs.
ZY PUBLIC WORKS RECTANGULAR STD. PLAN - 204.20
DEPARTMENT VANED GRATE
MARCH 2O08
CITY OF
RENTON
Planning/Building/Public Works Dept.
IN COMPLIANCE WITH CITY OF RENTON
STANDARDS
BY:
Date:
BY:
Date:
BY:
Date:
BY:
Date:
DATE:
CARPENTER SHORT PLAT 10/27/17
L U Al 4- 001200 U 16 - 0 0 4 6 3 6 FIELDBOOK: N/A
PAGE: N/A
DRAWING NO:
DETAILS 13708
SHEET:
OF.1
1 1 5
R
3
9
0
8
1
0
S
3
9
0
8
0
3