Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutRS_Hazmat Report 3400 E Valley Rd renton WA_May 2018
2517 EASTLAKE AVENUE EAST
SUITE 100
SEATTLE, WA 98102
206.233.9639 MAIN
866.727.0140 FAX
PBSUSA.COM
Hazardous Materials Survey Report
3400 East Valley Road
Renton, WA 98335
Prepared for:
Dale Walker
c/o Roger Hanson
HH&J Architects
Tacoma, WA 98402
May 18, 2018
PBS Project No. 41482.001
Hazardous Materials Survey Report
3400 East Valley Road
South End Auto Wrecking
Renton, Washington
©2017 PBS Engineering and Environmental Inc.
I
May 18, 2018
PBS Project No. 41482.001
TABLE OF CONTENTS
1 INTRODUCTION .............................................................................................................................................. 1
1.1 Project Background ................................................................................................................................................................... 1
1.2 Building Descriptions ............................................................................................................................................................... 1
1.3 Survey Process ............................................................................................................................................................................ 1
2 FINDINGS ......................................................................................................................................................... 1
2.1 Asbestos-Containing Materials (ACMs) ............................................................................................................................ 1
2.2 Lead-Containing Components ............................................................................................................................................. 2
2.3 Mercury-Containing Components ...................................................................................................................................... 2
2.4 PCB-Containing Components ............................................................................................................................................... 2
3 RECOMMENDATIONS .................................................................................................................................... 2
3.1 ACMs .............................................................................................................................................................................................. 2
3.2 Lead-Containing Paint ............................................................................................................................................................. 3
3.3 Mercury-Containing Components ...................................................................................................................................... 3
3.4 Survey Limitation ....................................................................................................................................................................... 3
APPENDICES
APPENDIX A: PLM Bulk Sampling Information
PLM Bulk Sample Inventory
PLM Bulk Sample Laboratory Data Sheets
PLM Bulk Sample Chain of Custody Documentation
APPENDIX B: AA Lead Paint Chip Sampling Information
AA Lead Paint Chip Sample Inventory
AA Lead Paint Chip Laboratory Data Sheets
AA Lead Paint Chip Chain of Custody Documentation
Metals Lab Data
APPENDIX C:
Photo Documentations
Certifications
Hazardous Materials Survey Report
3400 East Valley Road
South End Auto Wrecking
Renton, Washington
1
May 18, 2018
PBS Project No. 41482.001
1 INTRODUCTION
1.1 Project Background
PBS Engineering and Environmental, Inc. (PBS) performed a hazardous materials survey of South End Auto
Wrecking (former tenant) located at 3400 East Valley Road, Renton, Washington, in conjunction with planned
demolition of the structure. The intent of this investigation is to ensure that the owner is in compliance with
applicable regulatory requirements that a "good faith inspection” for ACMs be performed prior to renovation
or demolition activities.
At the request of the owner, all accessible areas of the building were inspected for the presence of asbestos-
containing materials (ACMs), lead-containing paint (LCPs), PCB-containing light ballasts, and mercury-
containing fluorescent lamps.
1.2 Building Descriptions
The building at 3400 East Valley Road that houses South Ends Auto Wrecking is a sheet metal building with a
sheet metal roof and concrete floors. The structure was reportedly constructed in the 1970’s. Interior finished
including textured gypsum walls and ceilings in the rest rooms and office space. The offices are heated with
electric wallboard heating units.
1.3 Survey Process
Accessible areas included in the project scope were inspected by AHERA Certified Building Inspector Janet
Murphy (Cert. No. 167197 Exp. 5/2/2019) in May 2018. PBS endeavored to inspect all accessible areas.
Inaccessible areas consist of those requiring demolition, fall protection, or confined space entry protocols in
order to gain access.
When observed, suspect materials were sampled. All samples were assigned a unique identification number
and transmitted for analysis to NVL Laboratories, Inc. (NVLAP #102063-0) under chain-of-custody protocols.
Samples were analyzed according to EPA Method 600R-93/116 using Polarized Light Microscopy (PLM), which
has a reliable limit of quantification of 1% asbestos by volume. Information regarding the type and location of
sampled materials can be found on the attached PLM Sample Inventory.
Suspect ACMs may exist in inaccessible areas. PBS endeavored to determine the presence and estimate the
condition of suspect materials in all inaccessible areas included in the scope of work. While PBS has
endeavored to identify the ACM that may be found in concealed locations, additional unidentified ACM may
exist.
2 FINDINGS
2.1 Asbestos-Containing Materials (ACMs)
Federal and state regulations define an asbestos-containing material as any materials that contains greater
than 1% asbestos.
None of the Materials sampled contained detectable asbestos
The following materials sampled and found not to contain detectable concentrations of asbestos are:
Hazardous Materials Survey Report
3400 East Valley Road
South End Auto Wrecking
Renton, Washington
2
May 18, 2018
PBS Project No. 41482.001
Texture on Walls and Ceilings — in the offices and restrooms;
Brown Covebase and Yellow Mastic — in the office and restrooms;
Joint Compound and Gypsum Wallboard — throughout;
Gray Sealant – on exterior window frames throughout;
White Sealant – on exterior window frames throughout
Black Gasket – in exterior wall penetration;
Brown Sealant – on exterior door frames throughout;
Black Sealant – on exterior door frames throughout;
Fiberglass Batt Insulation – lining walls and ceiling throughout;
Fire Door Core – roll door on west side of building.
For a complete listing of representative bulk sampling and associated laboratory analysis, refer to the
Attachments.
2.2 Lead-Containing Components
Nine (9) representative painted coatings were sampled for lead content. The samples were assigned unique
identification numbers and transmitted to NVL Laboratories, Inc. (AIHA IH #102063-0) in Seattle, Washington
under chain-of-custody protocols for analysis using Flame Atomic Absorption. Lead was detected in one (1)
of the nine (9) samples collected:
Red paint on metal/steel beams and columns throughout the building (0.11% Lead-Containing)
Refer to attachments for locations and metal laboratory results of paint samples.
2.3 Mercury-Containing Components
All fluorescent light tubes are presumed to contain mercury. PBS noted fluorescent tubes (including compact
bulbs) in the structure for the purposes of mercury vapor recovery prior to renovation activities. Caution
should be exercised during renovation to not damage these bulbs and light tubes that may spill mercury in
work areas.
2.4 PCB-Containing Components
PBS inspected representative fluorescent light fixture ballasts throughout the building. The light fixture
ballasts inspected were observed with “No PCB” labeling. PBS recommends all light ballasts be inspected
prior to disposal. All magnetic ballasts should be presumed to contain PCBs. All electronic ballasts are
presumed to not contain PCBs.
3 RECOMMENDATIONS
3.1 ACMs
PBS performed an asbestos survey of the subject site and found no asbestos-containing materials.
Hazardous Materials Survey Report
3400 East Valley Road
South End Auto Wrecking
Renton, Washington
3
May 18, 2018
PBS Project No. 41482.001
The possibility exist that suspect ACM may be present in equipment, wall and ceiling cavities, and in other
select concealed areas included in the scope of renovations. These may include, but are not limited to
waterproofing membrane, vapor barriers, internal gasketing, mastics, caulking, and sealants on HVAC
equipment, construction adhesives, electrical insulators, below grade pipe covering and insulation. In the
event that suspect ACM is uncovered during construction, contractors should stop work immediately and
inform the Owner promptly for confirmation testing. All untested materials should be presumed asbestos-
containing or tested for asbestos content prior to impact.
3.2 Lead-Containing Paint
Representative painted coatings from the project location were found to contain lead by laboratory analysis.
Impact of painted surfaces with detectable concentrations of lead requires construction activities to be
performed according to Washington Labor and Industries regulations for Lead in Construction. Concealed
painted coatings may exist in inaccessible areas or in secondary coatings on building components. These may
consist of standard interior paint on walls, floors and ceilings, in wall and ceiling cavities, or coatings on
concrete decking or piping. Any previously unidentified painted coatings should be considered lead
containing until sampled and proven otherwise. Impact of painted surfaces with detectable concentrations of
metals in building materials and products requires construction activities to be performed according to
Washington Labor and Industries regulations for Lead/Metals in Construction (WAC 296-155-176).
Workers impacting LCP and regulated metals should be Lead trained, provided the personal protective
equipment and use proper work methods and engineering controls to limit occupational and environmental
exposure to lead until an initial exposure assessment has been conducted.
Painted coatings may exist in inaccessible areas of the work area or in secondary coatings. Any previously
unidentified painted coatings should be considered lead containing until sampled and proven otherwise. Dust
control and housekeeping is crucial in preventing worker and occupant exposures.
3.3 Mercury-Containing Components
Fluorescent lamps (tubes and bulbs) are known to contain mercury and mercury vapors. All fluorescent and
compact lamps/bulbs and tubes at this site are presumed to be mercury-containing. PBS recommends that all
fluorescent lamps be carefully handled and recycled/disposed of in accordance with the contract documents
and applicable regulations during demolition activities. Breakage of lamps should be avoided to prevent
potential exposures to mercury. Washington Department of Safety and Health requires specific training,
handling, engineering controls and disposal practices when performing this work. All mercury waste shall be
handled in accordance with WAC 173-303.
3.4 Survey Limitation
Suspect materials (regulated lead-containing paint or asbestos) may exist in inaccessible areas at the project
site, such as in ceiling/wall cavities and in interstitial spaces. PBS endeavors to determine the presence and
estimate the condition of suspect materials in all accessible areas included in the scope of work. In the event
suspect materials are uncovered during construction, contractor should contact immediately the Owner for
associated asbestos or other regulated hazardous materials confirmation testing.
Hazardous Materials Survey Report
3400 East Valley Road
South End Auto Wrecking
Renton, Washington
4
May 18, 2018
PBS Project No. 41482.001
Report Prepared by:
PBS Engineering and Environmental Inc.,
Janet Murphy Willem Mager
AHERA Building Inspector Sr. Project Manager
Cert. # 167197, expiration 05/2/2019 AHERA Building Inspector
Cert. #165414 2/7/2019
APPENDIX A
PLM Bulk Sampling Information
PLM Bulk Sample Inventory
PLM Bulk Sample Laboratory Data Sheets
PLM Bulk Sample Chain of Custody Documentation
South End Auto Wrecking - 3400 E. Valley Rd, Renton, WAHH and J Architects/Dale WalkerPBS Engineering and Environmental Inc.PBS Project #41482.001PLM ASBESTOS SAMPLE INVENTORYMaterial TypeSample LocationLab DescriptionLab ResultLab41482.001 -1 Texture on Gypsum Wallboard South Hall Wall Layer 1: White powdery material with paint NAD SATLayer 2: White chalky material with paper NAD41482.001 -2 Texture on Gypsum Wallboard Southwest Office Wall Layer 1: White powdery material with paint NAD SATLayer 2: White chalky material with paper NAD41482.001 -3 Texture on Gypsum Wallboard South Office Wall Layer 1: White powdery material with paint NAD SAT41482.001 -4 Brown Cove Base Southwest Office Wall Layer 1: Brown rubbery material NAD SATYellow Mastic Layer 2: Tan mastic NADWall Texture Layer 3: White powdery material with paint NAD41482.001 -5 Yellow Cove Base Mastic East Side on Office Wall Layer 1: Yellow mastic NAD SAT41482.001 -6 Composite Retail Counter Area Layer 1: Trace white powdery material NAD SATJoint Compound Layer 2: White chalky material with paper NADWall Board41482.001 -7 Composite South Office Wall Layer 1: Trace white powdery material NAD SATJoint Compound Layer 2: White chalky material with paperWall Board41482.001 -8 Gray Sealant North Exterior Window Frame Layer 1: Gray soft/elastic material NAD SAT41482.001 -9 Gray Sealant East Exterior Window Frame Layer 1: Gray soft/elastic material NAD SAT41482.001 -10 White Sealant South Exterior Window Frame Layer 1: White soft/elastic material with paint NAD SAT41482.001 -11 Black Gasket Exterior Exterior Wall Penetration Layer 1: Black soft/elastic material NAD SAT41482.001 -12 Brown Sealant East Exterior Door Frame Sealant Layer 1: Brown soft/elastic material NAD SAT41482.001 -13 Black Sealant West Exterior Door Frame Sealant Layer 1: Black soft/elastic material NAD SAT41482.001 -14 Paper West Interior Wall Insulation Layer 1: White soft/elastic material NAD SATMastic Layer 2: Trace clear mastic NADFiberglass Layer 3: Yellow fibrous material NAD41482.001 -15 White Foam Core West Roll Door Insulation Layer 1: White foamy material NAD SATPBS Sample #May 18, 2018 NAD - No Asbestos Detected 1 of 1
APPENDIX B
AA Lead Paint Chip Sampling Information
AA Lead Paint Chip Sample Inventory
AA Lead Paint Chip Laboratory Data Sheets
AA Lead Paint Chip Chain of Custody Documentation
South End Auto Wrecking - 3400 E. Valley Rd, Renton, WAHH and J Architects/Dale WalkerPBS Engineering and Environmental Inc.PBS Project #41482.001AA LEAD PAINT CHIP SAMPLE INVENTORYPBS Sample #Paint Color / Component or SubstrateSample LocationResults (mg/kg)Results (%)Lab41482.001 -Pb1 Orange White / Gypsum Wallboard / Wall South Office Wall at Retail Counter <48 <0.0048 NVL41482.001 -Pb2 Red / Metal / Sill West Interior Window Sill <78 <0.0078 NVL41482.001 -Pb3 White / Wood / Frame South Office Door Frame <140 <0.014 NVL41482.001 -Pb4 White / Gypsum Wallboard / Wall Retail Counter Area <50 <0.0050 NVL41482.001 -Pb5 White Orange / Gypsum Wallboard / Wall South Office Wall <49 <0.0049 NVL41482.001 -Pb6 Red / Metal / Column Large Open Area 1,100 0.11 NVL41482.001 -Pb7 Tan / Metal / Siding Exterior Siding <60 <0.0060 NVL41482.001 -Pb8 White / Metal / Roll Door East side of building. <130 <0.013 NVL41482.001 -Pb9 Black / Gypsum Wallboard / Wall Interior Wall at Office/Accent Color <63 <0.0063 NVLMay 18, 2018mg/kg = Milligrams per kilogram< = Less than the Limit of Detection1 of 1
RE: Metals Analysis; NVL Batch # 1808462.00
Dear Ms. Murphy,
May 4, 2018
PBS Environmental (Seattle)
Janet Murphy
2517 Eastlake Ave E, Suite 100
Seattle, WA 98102
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical
instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence
of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually
expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually
expressed in mg/Kg (ppm) , Percent (%) or mg/cm2 by area. Dust wipe sample results are usually
expressed in ug/wipe and ug/ft2. TCLP samples are reported in mg/L (ppm). For air filter samples,
analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and
ug/m3. Other matrix materials are analyzed accordingly using published methods or specified by
client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure
levels, please call your local regulatory agencies for more details.
This report is considered highly confidential and will not be released without your approval.
Samples are archived for two weeks following analysis. Samples that are not retrieved by the
client are discarded after two weeks.
Thank you for using our laboratory services. if you need further assistance please feel free to call
us at 206-547-0100 or 1-888-NVLLABS.
Sincerely,
Shalini Patel, Laboratory Analyst
page 1 of 4
Analysis Report
Total Lead (Pb)
HH and J "South End Autowrecking"
PBS Environmental (Seattle)Client:
2517 Eastlake Ave E, Suite 100
Seattle, WA 98102
Ms. Janet MurphyAttention:
Address:
Project Location:Samples Received: 9
Samples Analyzed: 9
Client Project #: 41482.001
Batch #: 1808462.00
Date Received: 5/3/2018
Lab ID Client Sample #
Sample
Weight (g)
Results
in mg/Kg
Results in
percent
RL in
mg/Kg
Matrix: Paint
Method: EPA 3051/7000B
18044213 Pb1 0.2085 48 <48 0.0048<
18044214 Pb2 0.1276 78 <78 0.0078<
18044215 Pb3 0.0729 140 <140 0.014<
18044216 Pb4 0.1984 50 <50 0.0050<
18044217 Pb5 0.2021 49 <49 0.0049<
18044218 Pb6 0.1915 52 1100 0.11
18044219 Pb7 0.1679 60 <60 0.0060<
18044220 Pb8 0.0756 130 <130 0.013<
18044221 Pb9 0.1584 63 <63 0.0063<
ClientSampled by:
Aaron BrownAnalyzed by:
Shalini PatelReviewed by:
05/04/2018Date Analyzed:
05/04/2018Date Issued:
Bench Run No:2018-0504-2
mg/ Kg =Milligrams per kilogram RL = Reporting Limit
Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit
Note : Method QC results are acceptable unless stated otherwise.
Unless otherwise indicated, the condition of all samples was acceptable at time of receipt.
Shalini Patel, Laboratory Analyst
page 2 of 4
PBS Environmental (Seattle)1808462.00
9
Company NVL Batch Number
Total Number of Samples
HH and J "South End Autowrecking"
1 DayTAT
5/4/2018Due Date 3:10 PMTime
(866) 727-0140Fax
janet.murphy@pbsusa.comEmail
Project Manager Ms. Janet Murphy
(206) 233-9639
(206) 409-9904Cell
Phone
Rush Samples
Rush TAT
NoAH
41482.001Project Name/Number:Project Location:
Sample ID Description A/RLab ID
LEAD LABORATORY SERVICES
Subcategory
Item Code
Flame AA (FAA)
Metals
FAA-02 EPA 7000B Lead by FAA <paint>
2517 Eastlake Ave E, Suite 100
Seattle, WA 98102
Address
Pb11 A18044213
Pb22 A18044214
Pb33 A18044215
Pb44 A18044216
Pb55 A18044217
Pb66 A18044218
Pb77 A18044219
Pb88 A18044220
Pb99 A18044221
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Emily SchubertReceived by
CourierRelinquished by
Aaron BrownAnalyzed by
Results Called by
NVL
NVL
5/3/18
5/4/18
1510
Print Name
Entered By: Emily Schubert
Date: 5/3/2018
Time: 3:51 PM
Special
Instructions:
page 3 of 4
page 4 of 4
APPENDIX C
Photo Documentations
Certifications
3400 East Valley Road PBS: 41482.001
May 18, 2018
Photo 1: Lead-containing Paint – red paint on metal/steel columns throughout (3400 East Valley
Road)
Photo 2: Lead-containing Paint – red paint on metal/steel beams and structure throughout (3400 East
Valley Road).