Loading...
HomeMy WebLinkAboutD-230605w Q z 0 LLI 0 n 16+00 3 x X 3 0 0 0 0 M 0 N 0 0 LJ Q Z Ll 0 N N U) PROFILE ALONG STREET CENTERLINE SCALE: Horz. 1" = 20' Vert. 1" = 5' CB-1013CB-10A CB-11A 2.5.5--------- ...... CB.-10 ...... CB-1 1 B .. STA 23+77:4 STA 21 +57.9, - 6"vv 2„G STA 21 +55.4, STA 23+81 .9, CB-11 12.5'R -12.11 A12.2 R �ph Appx -12.0 L 6"w TYPE 1 TYPE 1 '� TYPE 1 TYPE 1 2"G Rim El=-252.1 -- Rim E1=252.28 Rim EI=256.33 -- Appx Appx Rim E1=256.19 2.50._- . ... 255-- 15 FT. 12-in. CPEP.............. -- 20 FT 12-in CPEP -- @ 7.80% IE=250.40 10 FT 12-in CPEP -- 14 FT 12-in CPEP IE=-251.3 ilk- @ 1.00% @ 1.00% IE=250.40 ................ IE=247.60 .....2.4.5._ IE=247..6.4....... ............. ....... ............ ....... .250--/ -- ...... CB-1 1... . IE=247.50 IE-247 50 0 2601 --- ... .. 255 235 CIVIL ENGINEERS & LAND SURVEYORS 2M MINOR AVE. EAST (206) 323-4144 SEATTLE, Washington 1-800-935-0508 98102-3513 FAX# (206) 323-7135 E-MAIL: info@brhinc.com - Ex 4"-6"SD ExSD STA 23+77.8, -2.9 L TYPE 2 54-in CB-10 STA 21 +55.5, -2.2'L Conc. Connect -- Rim EL=256.50 TYPE 2 48-in w/Couplings -- 12" E IE=251.40 Rim EL=252.63 246- 10 FT 12-in CPEP 12" W IE=250.40 12 E =247.50 ....................... IE IE=251.60 2.00� ................ .12" E IE=250.40 exSO- - 12" W IE=247.50 IE=251.40 SS SS Appx GS SS g"W Appx Appx GS Appx EL UI SS Appx WS Appx EL Unk me Appx I Appx EL Unk Rol RECOMMENDED FOR APPROVAL BY DANIEL CAREY BY 9/4/13 REVISION IIIIIIIIIIIIM - aw SURVEYED: BRH DESIGNED: DWC DRAWN: DWC CHECKED: DWC, RJS APPROVED: RJS SCALE: CALL 48 HOURS BEFORE YOU DIG 811 EXISTING UTILITY LOCATIONS ARE APPROXIMATE, NOT ALL UTILTIES MAY BE SHOWN. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES. GENERAL NOTES 1. OVERHEAD UTILITY LINES NOT SHOWN. 2. DO NOT BLOCK DRIVEWAYS EXCEPT WHEN INSTALLING NEW STORM SYSTEM IN FRONT OF THEM. 3. PROTECT/SAVE ANY TREES, PLANTS, LANDSCAPING, MAILBOXES, FENCES AND OTHER IMPROVEMENTS IN CONSTR AREA. RESTORE/REPLACE AFTER CONSTRUCTION. 4. SIDE SEWER LOCATIONS ARE APPROX AND MAY VARY FROM LOCATION SHOWN. 5. SIDE SEWERS IN CONFLICT WITH NEW STORM LINE SHALL BE REBUILT PER SIDE SEWER RELOCATION DETAIL. 6. PIPE LENGTHS, SLOPES ARE MEASURED FROM CENTER OF STRUCTURES. 7. ALL CB RIMS AND GRATES SHALL MATCH EXISTING GRADE UNLESS NOTED OTHERWISE. 8. TYPE 2 CB"s SHALL BE RING AND COVER UNLESS NOTED OTHERWISE. TYPE 2 CB AS SHOWN ON PROFILE: 2-FT SUMP, OR NO SUMP. TYPE 2 CB MAINLINE IE's GIVEN ON PIPE CALLOUTS. 9. TYPE 1 CB's SHALL BE FRAME AND VANED GRATE UNLESS NOTED OTHERWISE. TYPE 1 CB AS SHOWN ON PROFILE: 2-FT SUMP, OR CONCRETE INLET. ADJUST CB LOCATION & RIM EL AS NEEDED TO DRAIN, CONFIRM w/INSPECTOR. 10. KEEP ALL EX CB INLETS ACTIVE UNTIL REPLACED BY NEW TYPE 1 CB'S. 11. CONTRACTOR SHALL PROVIDE TEMP STORMWATER BYPASS/PUMPING AS NEEDED. E = PLUG EX PIPE CONSTRUCTION NOTES O 1. TEMP EROSION CONTROL: INSTALL CATCH BASIN FILTER FABRIC PER STD PLAN 216.30 AT ALL EX CB'S AND AT NEW CB's WHERE EARTHWORK OCCURS. INSTALL SILT FENCING WHERE NEEDED OR DIRECTED BY CITY. 2 2. CONNECT NEW STORM SYSTEM TO EX STORM SYSTEM. 3 3. ABANDON EX SD CATCH BASIN TYPE 2 AFTER FLOW IS TRANSFERRED TO NEW STORM SYSTEM. 4 4. ABANDON EX SD CATCH BASIN TYPE 1. 5 5. REPLACE STREET MONUMENT, IF DAMAGED. 6 6. CORE DRILL EX SDMH FOR NEW STORM CONNECTION. 7 7. ABANDON BORING/MONITORING WELL, B-1 THRU B-6. 8 8. POTHOLE UTILTIY AND SURVEY LOCATION AND ELEVATION. DETERMINE CLEARANCE FROM NEW SD. O9 9. PROJECT SIGN. 20 20. SEWER TEE REPLACEMENT, SEE DETAIL AND SEWER SCHEDULE. CONTRACTOR TO VERIFY LOCATION OF TEES PRIOR TO EXCAVATION. RESTORATION NOTES 260 1. PROTECT/SAVE ANY PLANTS, LANDSCAPING, MAILBOXES, FENCES AND OTHER IMPROVEMENTS IN CONSTR AREA. RESTORE/REPLACE AFTER CONSTRUCTION. Q2 2. ALL DISTURBED GRASS AREA SHALL BE RESTORED WITH SOD. 255 3. ALL DISTURBED GRAVEL AREAS SHALL BE RESTORED WITH CRUSHED SURFACE BASE COURSE (WSDOT 9-03.9(3)). 4. TRENCH PATCH SHALL BE PER DETAIL TYPICAL PATCH FOR FLEXIBLE PAVEMENT (PER STD PLAN 110). 250 5. CITY MAY REQUIRE DAMAGED ASPHALT OUTSIDE OF TRENCH PATCH AREA TO BE REMOVED AND REPLACED, AS NEEDED. 6. ALL CURB, GUTTER, SIDEWALK, AND DRIVEWAY RESTORATION SHALL MATCH EXISTING TYPE AND DIMENSIONS, UNLESS NOTED OTHERWISE. SAWCUT EXTENT AS DIRECTED BY CITY. 245 07 7. RESTORE CONIC CURB, GUTTER, SIDEWALK. Q8 8. RESTORE CONIC SIDEWALK (ASPHALT CURB OR NO CURB). Q9 9. RESTORE CONIC DRIVEWAY (ASPHALT CURB OR NO CURB). SHEET NOTES D=230605 '"ER"CAl-* NAVD 1988 NE 5TH PL / EDMONDS AVE NE As Noted HORIZONTAL: NAD 1983/1991 � CITY 0F 9-4-13 R E N TO N STORM SYSTEM REPLACEMENT PROJECT PAGE: ONE INCH DATUM DRAWING NO: AT FULL SCALE Planning/Building/Public Woks Dept. CAMAS AVE NE STA 20+80 t0 STA 23+80 2013009.00 IF NOT ONE INCH SCALE ACCORDINGLY SHEET: OF: 5 x IDI-1213ID161 Q D Z CT) U _?M z Mo c d Xrr z m I NZ r, M cn go 0 �Cf) ? D a Z Cil m n D m T LT, ru Z z m O A D cn D TI o mp E00 D �Dc s�