HomeMy WebLinkAboutD-2306090
N
N
CL
Ld
Q
Z
1--
C)
W
3
0
ry
a_
3 of w
Ln O LLJ �P �l ds b .. \ r- Z 1
�NZ \ U Z N� �O �9 c \ JIIN
Cv N \ � �° v 1 o 21 7227502180 z Z `�'
I` o N n 7227502185 Z w
Ln \ 0 (o c�i N 7227502195 7227502190 2502 NE 5th PL ,
\ °N° I °�° o \ \\�\ 572 EDMONDS AVE NE 568 EDMONDS AVE NE U
w 11 I� 578 EDMONDS AVE NE \ \\�
\ Z lill J N Q STA 32+43.7 24.2'LT 2 \\\\\ `-o
I = Z w m o 1 - F.H. ASSEMBLY 3 SDMH RIM buried �280.3 ° ^ W \\\\ = N Cr-,
°
\\\ W 0_ \ N_ o_ o \\\ N"
. I Q N o S 18"CONC. IE 271.1 w° W x_ \Y � IIO p-
1�■ NDS A a3 �• d3 r a \ 3 �w II O� W
PLUG AND BLOCK EXISTING . ' _ z VE. NE. N , 8"GONG. IE=271.1 F r- Z 3 �\ x O �, I- w m Z
z - O co �� No
CROSS. " - 0 30LF 6"DI WITH MEGA -LUG _D N > � a
1 - 10 PLUG o 0- z JOINT RESTRAINT �\\\\\\\\\\\\\\\� N \ 1 /
- RUST BLOCK � � /i • 1 CONC THRUST
STA 32+43.4 5.1 LT ���\; r, ,\
o ;� 1 - 16"x6" TAPPING TEE \9 PROTECT �a o J N N 1 \ 1 c Ql
-� Q� 1 - 6" GV (FLXMJ) W/ 1 Ira Ex TREE 1 �a Z~ w O Ira
1 C l� cv � l - � Ex Tree �'r _ _ cn a �
L
MEGA -LUG :x Tree
� c Bank?
_
Cd
P nc Bank. % • ° r � ° . ' ° o . .
;W ~ io v) \v TCd P a cr - uc
one Bank7� GW: ° �3:5' PVC-QW
10"W P t (Hi oo nCb c-gonk°
- -- DUC BANK? "
\
li
III
z
C
0
�B_c.
e
16"W
P ~
4"G P
O
LO
W b
�s. -
N N
II II
9MIS
z Z
3r0
~0
I=
O
O w In 3 DO
z
W
Ua- W N
co
'00?
_ C0,04
\ II co Do 00 ~O
ss
W 00
M
\ r`o(
\ N 04 (D
N
o
\
\ II N
\ w II II
- W
\ W
-
\y
�
16"W P
G(P)4
VD S
4„�(P SVD
SdD
N
O B-3
O
.CW
TCd(P)
> x
Lo a
TCd P
0 a' '0
V) �i p
°
MON.
IN CASE
Q w -t
m Q
REBAR
W/CAP IN CONC.
��
w �
II C4
"LS
hFT
11691 ", DIN 0.3'
o
Z w
N
\\ W
ucT �
\ 16-4• PVC
8-3.5" PVC Conc Bank? '
10' Conc Bank?�"
TCd P
TCd P �� �0 / Z l
CB - 2 DUCT BAND 1 3 S J
34 00 \ s "_9a Capped O M
-- - _ -- - �`��" -
-� CB-23 t
t
\ B-21 CB-22
tin 4"G(P � Z �
._
..PUNCH IN SMALL 7t
ON, IN CASE
WJ 0
w cn O W N
Z �
Z W I OO Q O� w U cn N
II
a Z Il Z ~ \ U11 Wwa-m
0 J W \ W W W co (0 00 !Z m
Q \ 0 I � N t0
EDM®N S AVE. NE. I
I z \ 0 Q11
W \\\ N� I NN W
11 N
W Z_ 2 z \ Lu W 11
Q -
9- - SVD SVD
TCd P
_
-3E
� -
2ao^
�0)
V) O O
N O C/)
11
0' 20'
II
w
28 3415.D° ....
CB-21 A
\ CB-21 A
CB-21 B
STA STA 3 4+36.1,
3
STA 34+36.1, 19.5'R
STA 34+35.2,
TYPE 1
-14.8'L
GAS
TYPE 1
SS Rim EL=-278.4
TYPE 1
TELE
8-3.5" PVC 4PPX
OPEN CURB FACE FRAME
CB-21 Appx
EL. Unk GAS
Rim El=-278.48
Conc Bank? 16"W
6"Sp
Rim E1=-278.4
28
AppX
Appx Appx Appx
6" W IE=276.7 exSD
TL 0 8" E IE=276.66
TELE ? Conc Bank? 12" N IE=275.90
Possible
Ex 6"PVC W IE=276.7 27 37 aLF 12-in _CPEP @ 3.50% 10„W l; a
DN IE=274.61 UP IE=275.90 Appx
34 FT 8-in DI
@ 1.00%
IE=277.00 0 NEW 24"SD
27 IE=276.66 0ExSS
PROFILE ALONG STREET CENTERLINE SCALE: Horz. 1" = 20' Vert. 1" = 5' 26 3+90 34 0o 34+50
CB-21 IE
CB-20 STA 34+00.1 , 1 1 .9'R CB-22 CB-23 IE
CB-19 STA 33+86.6, -2.2'L TYPE 2 48-in STA 35+06.5, 22.8'R STA 35+20.9, 16.2'R
TYPE 2 48-in Rim EL=279.04 TYPE 2 48-in TYPE 2 48-in
285 Rim. EL=279.41 12 S. IE=274.61 Rim EL=278.88 Rim EL=279.23
GAS 5
Appx ExSS GS
Appx SS TELE PVC ® \ \ \
Appx Runs E-W TELE Appx Conc Bank? 1 6"W 8-3. TELE
16-4" PVC 10
16
EL Unk GS Appx SS Conc PVC
4 WS`"W S5 Appx Conc Bank? Conc Bank. A
Appx A ox Appx EL Appx Appx Runs N-S
28O . . . . . . . . . . . . . . . . . . . . . . ExSD Appx . . P .PP 6"SD . . . . WS-WM . . . . EL Unk Appx
o. . EL EL Unk. AppX. . Appx. . ExSD . 280
o \ ExSS
18"SD a
Appx \ 0
275 :.. ................ �. .............................:. ......: 275
_- _-- - - - - Ex.SD 18-ir
ExSD 18-in -
270 _.................... -
_� - Crossing
8„S To -- - Appx
LU NE'
6 TH O ---- -`- W
170 F 24-in CPEP @ 0.30% Z
-�- - -- - C - C .30% 17 LF 24-in CPEP @ 0.30%
DN IE=270.21 UP IE=270.72
265 ... _ :.. ................: -... - N IE-271.12. UP IE=271.1.7. .
20 LF 24 in PEP @ 0 30% In
DN IE 270 72 UP IE 270 78. DN IE 270 78 UP IE 271.12 D J
f 0 ...
s 33+00 - 34+00 35+00 s
SECTION WEST
ON CAMAS AVE
CIVIL ENGINEERS & LAND SURVEYORS
2009 MINOR AVE. EAST (206) 323-4144
SEATTLE, Washington 1-800-935-0508
98102-3513 FAX# (206) 323-7135
E-MAIL: info@brhinc.com
\l6
RECOMMENDED
FOR APPROVAL
BY DANIEL CAREY 9/4/13
BY
REVISION
SURVEYED:
BRH
DESIGNED:
DWC
DRAWN:
DWC
CHECKED:
DWC, RJS
BY DATE APPR APPROVED:
RJS
D=230609
CALL 48 HOURS BEFORE YOU DIG
811
EXISTING UTILITY LOCATIONS ARE APPROXIMATE,
NOT ALL UTILTIES MAY BE SHOWN.
CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES.
GENERAL NOTES
1. OVERHEAD UTILITY LINES NOT SHOWN.
2. DO NOT BLOCK DRIVEWAYS EXCEPT WHEN INSTALLING NEW STORM SYSTEM
IN FRONT OF THEM.
3. PROTECT/SAVE ANY TREES, PLANTS, LANDSCAPING, MAILBOXES, FENCES AND
OTHER IMPROVEMENTS IN CONSTR AREA. RESTORE/REPLACE AFTER CONSTRUCTION.
4. SIDE SEWER LOCATIONS ARE APPROX AND MAY VARY FROM LOCATION SHOWN.
5. SIDE SEWERS IN CONFLICT WITH NEW STORM LINE SHALL BE REBUILT
PER SIDE SEWER RELOCATION DETAIL.
6. PIPE LENGTHS, SLOPES ARE MEASURED FROM CENTER OF STRUCTURES.
7. ALL CB RIMS AND GRATES SHALL MATCH EXISTING GRADE UNLESS NOTED OTHERWISE.
8. TYPE 2 CB"s SHALL BE RING AND COVER UNLESS NOTED OTHERWISE.
TYPE 2 CB AS SHOWN ON PROFILE: 2-FT SUMP, OR NO SUMP.
TYPE 2 CB MAINLINE IE's GIVEN ON PIPE CALLOUTS.
9. TYPE 1 CB's SHALL BE FRAME AND VANED GRATE UNLESS NOTED OTHERWISE.
TYPE 1 CB AS SHOWN ON PROFILE: 2-FT SUMP, OR CONCRETE INLET.
ADJUST CB LOCATION & RIM EL AS NEEDED TO DRAIN, CONFIRM w/INSPECTOR.
10. KEEP ALL EX CB INLETS ACTIVE UNTIL REPLACED BY NEW TYPE 1 CB'S.
11. CONTRACTOR SHALL PROVIDE TEMP STORMWATER BYPASS/PUMPING AS NEEDED.
= PLUG EX PIPE
CONSTRUCTION NOTES
01. TEMP EROSION CONTROL: INSTALL CATCH BASIN FILTER FABRIC PER STD PLAN
216.30 AT ALL EX CB'S AND AT NEW CB's WHERE EARTHWORK OCCURS.
INSTALL SILT FENCING WHERE NEEDED OR DIRECTED BY CITY.
2 2. CONNECT NEW STORM SYSTEM TO EX STORM SYSTEM.
3 3. ABANDON EX SD CATCH BASIN TYPE 2 AFTER FLOW IS TRANSFERRED
TO NEW STORM SYSTEM.
4 4. ABANDON EX SD CATCH BASIN TYPE 1.
5 5. REPLACE STREET MONUMENT, IF DAMAGED.
6 6. CORE DRILL EX SDMH FOR NEW STORM CONNECTION.
7 7. ABANDON BORING/MONITORING WELL, B-1 THRU B-6.
8 8. POTHOLE UTILTIY AND SURVEY LOCATION AND ELEVATION.
DETERMINE CLEARANCE FROM NEW SD.
\9 9. PROJECT SIGN.
20 20. SEWER TEE REPLACEMENT, SEE DETAIL AND SEWER SCHEDULE.
CONTRACTOR TO VERIFY LOCATION OF TEES PRIOR TO EXCAVATION.
RESTORATION NOTES
1. PROTECT/SAVE ANY PLANTS, LANDSCAPING, MAILBOXES, FENCES AND OTHER
IMPROVEMENTS IN CONSTR AREA. RESTORE/REPLACE AFTER CONSTRUCTION.
zj, 2. ALL DISTURBED GRASS AREA SHALL BE RESTORED WITH SOD.
0 3. ALL DISTURBED GRAVEL AREAS SHALL BE RESTORED WITH
CRUSHED SURFACE BASE COURSE (WSDOT 9-03.9(3)).
4. TRENCH PATCH SHALL BE PER DETAIL TYPICAL PATCH FOR FLEXIBLE
PAVEMENT (PER STD PLAN 110).
5. CITY MAY REQUIRE DAMAGED ASPHALT OUTSIDE OF TRENCH PATCH AREA
TO BE REMOVED AND REPLACED, AS NEEDED.
6. ALL CURB, GUTTER, SIDEWALK, AND DRIVEWAY RESTORATION SHALL MATCH
EXISTING TYPE AND DIMENSIONS, UNLESS NOTED OTHERWISE.
SAWCUT EXTENT AS DIRECTED BY CITY.
�7 7. RESTORE CONC CURB, GUTTER, SIDEWALK.
80 8. RESTORE CONC SIDEWALK (ASPHALT CURB OR NO CURB).
9Q 9. RESTORE CONC DRIVEWAY (ASPHALT CURB OR NO CURB).
SHEET NOTES
\ 1. PROVIDE TEMP WATER TIGHT CONNECTION OR BYPASS PUMPING BEFORE
\CUTTING AND CAPPING EX 18"SD.
2. INSTALL CB-21A,B AFTER NEW 24"SD IS ACTIVE.
\ 3. REBUILD SEWER MAIN AT CROSSING, SEE DETAIL.
4. WATER SERVICE, CONFIRM LOCATION.
4 COORD WITH CITY WATER MAINTENANCE TO RELOCATE IF NEEDED.
5 5. CENTURYLINK TELECOM CONDUITS, CONC ENCASED DUCT BANK.
COORD W/ PRIVATE UTILTIY IF WORK NEEDED.
10 6. REPLACE EXISTING 34' WATER SERVICE WITH NEW 1" WATER SERVICE PER
STANDARD DETAIL 320.1. (TYPICAL FOR ALL SERVICES) CONNECT NEW METER
SETTER AND NEW COPPER TAIL PIECE TO CUSTOMER PRIVATE SERVICE LINE.
SCALE:
VERTICAL-NAw 1988
•. �- CITY 0 E
As Noted HORIZONTAL::NAD 1983/1991 ,�
RENTON
ONE INCH DATUM
AT FULL SCALE Planning/Building/Public Works Dept.
IF NOT ONE INCH
SCALE ACCORDINGLY
NE 5TH PL / EDMONDS AVE NE
STORM SYSTEM REPLACEMENT PROJECT
EDMONDS AVE NE STA 32+12 to STA 35+70
9-4-13
FIELDBOOK:
PAGE:
DRAWING NO:
2013009.00
SHEET: OF:
9 x
�. 2^
IDz
UJ
M z
D
m- T
N W
z m
m
nT1
�o
�
D
n�
m
-
z
�.
AZ
z
�M
C
o
�z
m
7
O
o
U0
z ~c
b�
bm�
1
O
am
C
N
z�
tTJ
W
O
0
�C"IIIIIi
C�
y
D
'T1
Ro
�o
o�
D
O
�
SD
G
_
I D -12131016