HomeMy WebLinkAboutD-230615w Q z U w 0 ry 3 0 I 0 x / 3 0 0 O n M 0 N 0 0 / 0 Z J U- �I EXISTING TEE SEE NOTE 1 3' MAXIMUM LENGTH OF FIRST PIECE OF STRAIGHT PIPE EXISTING TEE SEE NOTE 1 EXISTING SEWER MAIN 0.05 FT/FT MINIMUM SLOPE CONFLICTING SIDE SEWER STORMWATER PIPE SIDE SEWER RELOCATION ABOVE OR BELOW NEW STORM PIPE (TYP) REMOVE CONFLICTING SIDE SEWER NEW STORMWATER PIPE POSSIBLE CLEANOUT SEE NOTE 5 POSSIBLE CLEANOUT SEE NOTE 5 EXISTING SIDE SEWER --,- 0.02 FT/FT MINIMUM SLOPE NEW 6" SIDE SEWER FOAM BLOCK, SEE NOTE 4 CONNECT SIDE SEWER WITH ELASTOMERIC FLEXIBLE COUPLING INSTALL 6"x 4" REDUCER, IF NEEDED 1 /8, 1 /16, OR 1 /32 BENDS AS NEEDED (90' NOT ALLOWED) NOTES: 1. IF EXISTING TEE IS NOT USEABLE FOR RECONNECTION CONTRACTOR SHALL CUT IN A NEW TEE REPLACEMENT. 2. CONCRETE BLOCK REQUIRED AT NEW SADDLE WHEN ANGLE AT MAIN EXCEEDS 25`. SEE CITY DETAIL DWG 406.1. 3. ALLOWABLE SIDE SEWER PIPE AND FITTINGS: POLYVINYL CHLORIDE (PVC) SDR 35, OR OTHER MATERIAL, AS APPROVED BY CITY INSPECTOR. 4. FOR 3" SEPARATION INSTALL VX 2' X 2" THICK STYRENE FOAM BLOCK BETWEEN NEW PIPE AND 6" SIDE SEWER RELOCATION. 5. IF SIDE SEWER RELOCATION REACHES CURB EXTEND NEW 6" SS TO BEHIND SIDEWALK AND INSTALL CLEANOUT PER CITY DETAIL DWG 406.1, 407. 6. BEDDING SHALL BE WSDOT 9-03.12(4) GRAVEL BACKFILL FOR DRAINS. 7. ALL SIDE SEWER RECONSTRUCTIONS SHALL BE APPROVED BY CITY INSPECTOR PVC SPOOL (LENGTH AS DIAMETER TO EX. SEWER MAID, SIDE SEWER RELOCATION (TYP) NTS EX. MAIN SIZE X 6" SEWER (TYP) TRONG-BACK" COUPLING SEEDED) 1. BEDDING SHALL BE PER WSDOT SPECIFICATION 9-03.12(4) GRAVEL BACKFILL FOR DRAINS. SEWER TEE REPLACEMENT DETAIL (TYP; (NTS) CIVIL ENGINEERS & LAND SURVEYORS 2009 MINOR AVE. EAST (206) 323-4144 SEATTLE, Washington 1-800-935-0508 98102-3513 FAX# (206) 323-7135 E-MAIL: info@brhinc.com NO. SEE NOTE 4 CLEAN SURFACE AND BOTTOM AREA. PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE GROUTED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION. For TYPE 1 and TYPE 2 Catch Basins BASE SECTION )N NOTES 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE GROUTED TO FINAL GRATE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO GROUT THE COVER OR GRATING IN PLACE PER WSDOT STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3. MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR Y2 BOND. o~ o� STD. PLAN - 202.00 PUBLIC WORKS CATCH BASIN INSTALLATION A'•`o DEPARTMENT MARCH 2O08 CATCH BASIN INSTALLATION (TYP,) STD PLAN 202.00 (NTS) NEW STORMWATER PIPE NEW 8"PVC FOAM BLOCK SEWER MAIN CDF FILL FLEXIBLE COUPLING EX 8" SEWER CONIC� . I f 5) -I 5'� NOTES: 1. ALLOWABLE SEWER PIPE AND FITTINGS: POLYVINYL CHLORIDE (PVC) SDR 35 OTHER MATERIAL, AS APPROVED BY CITY INSPECTOR. 2. INSTALL Vx 2'x 2" THICK STYRENE FOAM BLOCK BETWEEN NEW SD PIPE AND NEW SEWER MAIN. 3. FLEXIBLE COUPLING SHALL BE FERNCO "STRONG -BACK" COUPLING, TYPE AS NEEDED. 4. BACKFILL CROSSING WITH CDF, DO NOT COVER COUPLINGS. RECOMMENDED FOR APPROVAL BY DANIEL CAREY 9/4/13 BY REVISION SEWER MAIN CROSSING (TYP (NTS) PAVEMENT PATCH PAY LIMIT 6.5' MIN. 1' 1' 2.5' 1' 1' MIN MIN MIN MIN MIN 2" SAWCUT AND REMOVE 2 " HMA OR ACP OR GRIND. CLASS 'B' SEAL WITH AR-4000W 6" CRUSHED SURFACING TOP COURSE HMA OR ACP CLASS 'B" COMPACT TO 95% MODIFIED PROCTOR SEE NO TE 2 TRENCH BEDDING AND BACKFILL, SEE DETAIL TRENCH WIDTH AS REQUIRED BY PIPE SIZE (SEE WSD 0 T STD SPEC 2- 09.4) PLUS ALLOWANCE FOR ANY SHORING. SHORING, IF NEEDED, SHALL MEET WSDOT STD SPEC 7- 08.3(1)B. NO TES.- 2. MINIMUM THICKNESS AND MATERIAL SHALL BE PRINCIPAL/MINOR/COLLECTOR, ARTERIAL & INDUSTRIAL ACCESS STREETS - 6"HMA OR ACP CLASS "B'; RESIDENTIAL ACCESS STREETS - 2" HMA OR ACP CLASS 'B'; IN NO CASE SHALL THE THICKNESS BE LESS THAN THE EXISTING PAVEMENT SECTION. TYPICAL PATCH FOR FLEXIBLE PAVEMENT PER STD PLAN - 110 TRENCH EXCAVATION PAY LIMIT (NTS) 30" ID - 5 1 /2' 24" ID - 5' 12" ID - 3 1 /2' SEE DETAIL FOR PAVEMENT PATCH BACKFILL MATERIAL WSD 0 T SECTION 9- 03.19 BANK RUN GRAVEL, OR NA TI VE MATERIAL IF IT MEETS SPECS. PIPE ZONE MATERIAL INSDOT 2006 SECTION 9-03.12(3) GRAVEL BACKFILL FOR PIPE ZONE BEDDING NEW UTILITY PIPE EXCA VA TION OF UNSUITABLE SOIL (IF NEEDED) DEPTH AS APPROVED BY ENGINEER BACKFILL WITH FOUNDATION MATERIAL MEETING WSDOT SECTION 9-13.6 QUARRY SPALLS NO TES 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT PIPE ZONE MATERIAL TO 95% MAXIMUM DENSITY EXCEPT DIRECTLY OVER PIPE WHERE COMPACTION WILL BE HAND TAMP ONLY. 4. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE THAT THE FLOW LINE IS MAINTAINED. TYPICAL TRENCH BEDDING AND BACKFILL (NTS) D=230615 SURVEYED: SCALE: DATE: VERTICABRH HORIZONTAL•."D 1983�1991 �► CITY O� NE 5TH PL / EDMONDS AVE NE 9-4-13 DESIGNED: AS Noted ,,_ DWC STORM SYSTEM REPLACEMENT PROJECT PELLEBOOK: DRAWN: _ RENT 0 N DWC DRAWING NO: ONE INCH DATU M CHECKEDAT FULL SCALE Planning/Building/Public Works Dept. STORM DETAILS DWC, RJS IF NOT ONE INCH 2O13009.00 BY DATE APPR PRO RJS SCALE ACCORDINGLY SHE: OF: 5 OF. x IDI-12131016 oD C I4z Icy z E c= (zEar �Crn Ln coNz m z m n D T mc 6 C E m CCn �< R D I,,m Arno rr lu z z m a n D z C 00 m 10 I D 0 m D Do TOTE AJ DC IDn c