! (TYP)
' I I
1
=D 4" AC WATER
(TYP) \
\ FD MIC
CONC MON W/IiIRASS DISC
\\DN 0.3'
- — — — 1 —
—ss—ss—
°
d
a EXISTING
100W LUMINAIRE
ON POWER POLE
— —I K NAIL
I
w I
u I
I
;
I
W
I
>
e
Q
I
rn
i
I
o<
Zz
°
L
Qj
OF
I
,
N
o
FUTURE I
o
LUMINAIRE f
o
BY OTHERS!
'
r�
1 °
'
co
�
I
I
�
I
N
= J
i
W
i
'Izo
i
I
II
w
oU
4a
o
Z w
! o
I
N
LA
! c
'
i
_
z I
IN
I
I
—fs
}}w
w
z
3
w
N
as
a
a
LI
Q
0
m
z
0
w
ry
0
z
20 0 20 40
scale feet
1
1
LIMELITE SHORT PLAT
A PORTION OF THE NE 1/4 OF SECTION 29, T. 29 N., R. 05 E., W.M.
CITY OF RENTON, STATE OF WASHINGTON
FUTURE
LUMINAIRE
BY OTHERS
4" AC (R)
—w—W—W—W—w—w—w—
SE 162ND STREET
11+00
11+50
LOT 3
S88°29'39"E
99.00'
LOT 4
/1\
FF-eA83.13
FF=483.07
I
I
I
0,-
6
Lv
M
z
LOT 2
1
d
N
FRI
1
FUTURE
LUMINAIRE OPP
BY OTHERS
_r"'L— — _ — — — I -
w—w—w
S88°29'39"E 730.79' ,z+so
50.661'
I
I
LOT 1
LIP
019
i
r
!
S88°2
09"E
1 1.31',
7
�•,�
4.67
i
e:
'
}
::}: I
' l'<•• s.•
�: '
r.
�. :.. •
_�. 1:,•::Sr,.�:.
----
LOT 5
FF=481.55
_
_ — — — --=•
OU 1
0 0 I
.w— I
CAUTION;
LOCATION OF EXISTING UTILITIES SHOWN IS
APPROXIMATE AND MAY NOT BE ACCURATE
OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO POTHOLE AS REQUIRED
AND FIELD VERIFY LOCATION OF UTILITIES
PRIOR TO PROCEEDING WITH CONSTRUCTION.
UNDERGROUND UTILITY NOTE:
YOU MUST CALL 811 NOT LESS THAN 72 HOURS
BEFORE BEGINNING EXCA VA TION WHERE ANY UNDERGROUND
UTILITIES MAY BE LOCATED. FAILURE TO DO SO COULD MEAN
BEARING SUBSTANTIAL REPAIR COSTS (UP TO THREE TIMES THE
COST OF REPAIRS TO THE SERVICE).
LUMINAIRE SCHEDULE
CONSTRUCTION NOTES
O1 INSTALL NEIGHB❑RH❑❑D STREET PEDESTRIAN LUMINAIRE FIXTURE AND POLE PER
STANDARD PLAN 116A, CONCRETE F❑UNDATI❑N, AND ASS❑CIATED JUNCTI❑N BOX PER
DETAILS ON SHEET 2 AND 3, AND LUMINAIRE POLE SCHEDULE.
2O INSTALL ELECTRICAL SERVICE CABINET # XXX PER DETAILS ❑N SHEET 3, LOCATED
ON ROAD A AT APPR❑XIMATE STATI❑N 21+75, 15.5' LT. C❑❑RDINATE WITH PSE FOR
SERVICE C❑NNECTI❑N. LABEL BACK ❑F CONTACTOR CABINET WITH ADDRESS
L❑CATI❑N; USE 1" LETTERS.
O INSTALL TYPE 1 JUNCTI❑N BOX WITH CONCRETE PAD,
WIRING SCHEDULE
CONDUIT
RUN
0
CONDUIT
SIZE
CONDUCTORS
NOTES
1
2.0" PVC
(SCHEDULE
40)
2—#8,
1—#8 GREEN
2
2.0" PVC
SCHEDULE
40
2— 8
1— 8 GREEN
3—#14
PHOTOCELL
3
2.0" PVC
SCHEDULE
40
PSE
POWER
4
2.0" PVC
(SCHEDULE
40)l
PULL
STRING
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION OPERATIONff IL
cbarnes 06/22/2017
LEGEND
LED PEDESTRIAN LUMINAIRE
AND DECORATIVE POLE
LED ROADWAY LUMINAIRE
AND DECORATIVE POLE
-------
PVC CONDUIT (SEE WIRING SCHEDULE)
TYPE 1 JUNCTION BOX WITH
®
CONCRETE PAD
®
SERVICE CABINET
AWIRE
NOTE
O
CONSTRUCTION NOTE
LUM.
NO.
POLE
ID. NO.
CIRCUIT
NO.
LOCATION
OFFSET
(FEET)
LED LAMP
WATTAGE
MAST ARM
(FEET)
MOUNTING
HGT. (FT.)
STANDARD
PLAN #
116.1
1
44020 44
A
114TH AVE SE 21+67
19.5' LT
44 LED
NA
14'
2
44030 44
A
114TH AVE SE 20+54.5
16.5' LT
44 LED
NA
14'
116.1
3
44040 441
A
I SE 162ND ST 10+45.5
1 16.5' RT
1 44 LED
NA
14'
116.1
4
44050 441
A
I SE 162ND ST 11+45
16.5' RT
1 44 LED
NA
14'
116.1
Tjaff
NORTHWEST �X
TRA FF/C EXPERTS
11410 NE 124th St., #590, Kirkland, WA 98034
Phone:425.522.4118 Fax:425.522.4311
T-398001
(5
Z
m
0
W
Li.l
IL
V)
w
w
0-
0-
0
W
0
IL
N
H
O
a
L
w
X
m
I�
,�
V /
0
Z
N
(O
W ()
V
T
LLJ
0
J
x c,
z V) Z U
w � U
z -
0 Lq
z
Q 4 U
V)
IDw IL
160 113 [6) IIL
w
0
z
0
w
0
z
(4) 9vAt.:; 0
p.. Eg^ l ATI ACL'CPlING4714
ALL ALUMIN;ITB Lti A! 9 AN6 POLEF;P.tj"ANI 51
PtolEO PANS. SN{LL .01=11f ANCHOR ti(]L e
PRIMED ANC POWDER COATED:
FIN!% COL OyT RAL SOC97X '11 HLACIN' .: 9:
'�
��'P�,
PRESTIGE SmES (CY17T4) LED
. POST TOP 13:ACRAIP.E.;YKTTAGE 2.4, t3 _ V 6,L4�,
PER YI ANS; 4,e0a GCT. T2O-7X7V EYE
Y �ACE0
tNiRERSA . DRIA R. APfII. y BAR 2 &ONTSli:T ikLE$S
kiBBA APPROVE
ACVLIC lE BY SLATED OTNEi2YF5E
BE N Et AL T(S fiFI IV€RER CONDUIT
PLANS CENTER IN FO NDATION
EDITURE�
1+4 'k CIRCLE (D!A t R
SE PtA7E Dfft L,
+�lOitl�R ¢pLT BATrlS SHEIK
#4 HOOK 0 12"
FOUNDATION SEC71ON
2' CONGOIT UNLESS CROaJND Pckf To
STATED OTHERWISE ON FOUNDATION
PLANS
i
.;/A' ORAMt•1!:R (TYP'I
1'-6" MIN se ow \\}�
GROUND,
2' TLIGH? -0' MIN UNDERFUR STREET I
FOR RI O'CAi. PAVEMENT
t8iM8it9A DET1vT,
REM TO. CITY Or ttT.- i THE COItiNA'T
R£NTW ST'J 'FLAN 121 fi" MIN 8E'+0ND
FOUNOAPiN OR THE
WNTROLLED t3ENSITY
BACKFflt t a
I
a
14'=0' RUTE) SHAPE, S" DIAMETER, Q4 HBOP9 12" r' !
STRAlOrIT ALUMINUM POLE o
(PW-I44646-RAL906STX-TN43) B - y5 BARS,
BY CYCLONE (OR APPROVED EQUAL) EVENLY SPACS I
INSTALL GROUT.
?RTYgm I/2"' INA ORAIN
TUEE T14RO 4 GROUT.
2'K5' HANDHOLC
DECTXtATIk ALLTMINFiM CF.;— -
BASE. COV".. B044 91 =LONE.
(09 ;Af?tK!BVEOf,QULN)
SEE POLE 8.45E
DETAIL, THIS
SHECT
� FGR FuUNT;A1tON if€TA.S,
SEE T14S 'HET
POLE ELEVATION
2 Tj2` CLR
• MhN._n.T u
WEtVN 1
24"
FOUNDATION i)E.TAIL
7/6' DIA HOLE
/—
( YP)
I/4' STEEL PLATE
8� T CIRCLE (DIA
PEfl BASE PLATE
.DETAL YWS' 901;'
ANCHOR. BOLT, 4 TOTAL
DIA (TYP)
314" NEX NUTS, STEEL X
RE
O'D PER ANCHOR SOLT),
FLAT WWAW.RS fb RUTD.PLN
ANCHOR 86 i
ANCHOR BOLT ASSCkWLY DETAIL
FOUNDATION DETAILS
PUBLIC VORKS NEIGHBORHOOD STREET
DEPARTMENT PEDESTRIAN LUMINAIRE
FIXTURE AND POLE DETAILS
INSTALL DECAL NUMBERS VERTICALLY.
INSTALL IN DRY WEATHER, 00' F OR
ABOVE.
NUMBERING
2 EXAMPLES
3
4
C LED TYPE
7� �.
WATTAGE
CURB
MOUNTING
HEIGHT o�0
15 FEET
45'
TRAFFIC
FLOW
PLAN VIEW
1-3/4" TO 2"
2" TO 2-7/8"
2-1/2" 1C S
T p-.-A
DFCAL:
REFLECTORIZED GOTHIC GOLD OR WHITE
LEGEND ON BLACK BACKGROUND
U4 Y a STD. PLAN - 121
+ PUBLIC WORKS STREET LIGHT STANDARD
�- DEPARTMENT DECAL NUMBERING SYSTEM PRQ ED:
CAIJTIDN:
LOCATION OF EXISTING UTILITIES SHOWN IS
APPROXIMATE AND MAY NOT BE ACCURATE
OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO POTHOLE AS REQUIRED
AND FIELD VERIFY LOCATION OF UTILITIES
PRIOR TO PROCEEDING WITH CONSTRUCTION.
UNDERGROUND UTILITY NOTE:
YOU MUST CALL 9-800-424-5555 NOT LESS THAN 72 HOURS
BEFORE BEGINNING EXCA VA TION WHERE ANY UNDERGROUND
UTILITIES MAY BE LOCATED. FAILURE TO DO SO COULD MEAN
BEARING SUBSTANTIAL REPAIR COSTS (UP TO THREE TIMES THE
COST OF REPAIRS TO THE SERVICE).
OF RENTON STANDARDS
TRANSPORTATION OPERATION % +
cbarnes 06/22/2017
Tj!;?f7fE'ArH
TRAFF/C EXPERTS
11410 NE 124th St., #590, Kirkland, WA 98034
Phone:425.522.4118 Fax:425.522.4311
W
SST
INA
4-17-17
T-398002