Loading...
HomeMy WebLinkAboutR-3980252 FINISH GRADE z M N TREE STAKE PREVAILING ROOTBALL WIND TRUNK TREE STAKE PLASTIC TREE TIES WOOD STAKE, STAKES SHOULD ROOT FLARE SHALL BE LOCATED ABOVE GROUND LINE 3" MULCH LAYER, KEEP AWAY z EH 3" WATER BASIN SCARIFY SIDE & BOTTOM OF PLANTING PIT TO ALLOW FOR ROOT PENETRATION I I I 1=1 I s�opFl Irr. I'�• �oQ I CONCRETE SIDEWALK 3x MINIMUM ROOTBALL DIAMETER RECOMPACT SUBGRADE NOTES: n TREE PIT SHALL NOT BE LESS [-4.] TREE STAKES PERPENDICULAR THAN 3 TIMES ROOT BALL DIA.1 ITO THE PREVAILING WIND 2❑ CUT ALL TIES AND FOLD RACK RLAP 5❑ PLANT TREES 2" HIGHER THAN FROM UPPER 1 3 OF ROOT BALL DEPTH GROWN IN NURSERY 3❑ REMOVE ALL PLASTIC AND TWINE TYPICAL DECIDUOUS TREE PLANTING DETAIL NTS REMOVE BURAP TWINE OFF TOP 1 3 3-4" MULCH FINISH GRADE ROOT PENETRATIONI RECOMPACT SUBGRADE ENSURE THAT ROOT FLARE WILL NOT SETTLE BELOW GROUND LINE TYPICAL SHRUB PLANTING DETAIL NTS DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Print Form Reset Form Save Form CITY OF -----Renton TREE RETENTION WORKSHEET Planning Division 1055 South Grady Way -Renton, WA 98057 Phone:425-430-7200 1 www.rentonwa.gov 1. Total number of trees over 6" diameter', or alder or cottonwood trees at least 8" in diameter on project site 11 trees 2. Deductions: Certain trees are excluded from the retention calculation: Trees that are dangerouS2 trees Trees in proposed public streets trees Trees in proposed private access easements/tracts trees Trees in critical areas' and buffers trees Total number of excluded trees: o trees 3. Subtract line 2 from line 1: 11 trees 4. Next, to determine the number of trees that must be retained 4, multiply line 3 by: 0.3 in zones RC, R-1, R-4, R-6 or R-8 0.2 in all other residential zones 0.1 in all commercial and industrial zones 3 trees 5. List the number of 6" in diameter, or alder or cottonwood trees over 8" in diameter that you are proposing5 to retain 4: 8 trees 6. Subtract line S from line 4 for trees to be replaced: (if line 6 is zero or less, stop here. No replacement trees are required) (5) trees 7. Multiply line 6 by 12" for number of required replacement inches: (56) inches 8. Proposed size of trees to meet additional planting requirement: (Minimum 2" caliper trees required for replacement, otherwise enter 0) 0 inches per tree 9. Divide line 7 by line 8 for number of replacement trees6: (If remainder is .5 or greater, round up to the next whole number) o trees Measured at 4.5' above grade. Z A tree certified, in a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed landscape architect, or certified arborist, and approved by the City. 3 Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050. "Count only those trees to be retained outside of critical areas and buffers. s The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-1301-17a. 6 When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2") caliper or an evergreen at least six feet (6') tall, shall be planted. See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees. 1 H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\Tree Retention Worksheet.docx 08/201E CANOPY DRIP LINE NO TRESPASSING 'ROTECTED TREE' iIGN POSTED EVERY 50 "EET (MINIMUM OF 2). VEGETATION AND TREE FENCING SHALL BE A MINIMUM OF 6' HIGH TEMPORARY CHAIN LINK FENCING WITH 10' LACING BETWEEN POSTS. PROTECTION MEASURES DURING CONSTRUCTION: 1. CONSTRUCTION STORAGE PROHIBITED: DO NOT FILL, EXCAVATE, STACK OR STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH IN ANY WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO \ BE RETAINED. J 2. FENCED PROTECTION AREA REQUIRED:PRIOR TO DEVELOPMENT ACTIVITIES, A 6' HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO ONE AND ONE -QUARTER FEET FOR EVERY ONE INCH OF TRUNK CALIPER, WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION j TRACT. PLACECARDS SHALL BE PLACED ON FENCING IF LESS THAN 50' INDICATING THE WORDS, 'NO TRESPASSING -PROTECTED TREES' OR ON EACH SIDE OF THE FENCING IS LESS THAN 50'. SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON 4 SIDES. 3. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE TO BE RETAINED IS TO BE RAISED, A DRY ROCK WALL OR ROCK WELL SHALL BE CONSTRUCTED AROUND THE TREE. THE DIAMETER FO THIS WALL OR WELL MUST BE EQUAL TO THE TREE'S DRIP LINE. 4. MULCH LAYER REQUIRED; ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF 3" OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. PROTECTED ROOT ZONE WITHIN THE CANOPY DRIP LINE - ACTUAL FEEDER ROOTS EXTEND WELL BEYOND DRIP LINE RENTON TREE PRESERVATION DETAIL NTS n INSTALL GROUNDCOVERS DEPTH PLAN VIEW OF SPACING NC�I�I]:]�.Y.yh[e»ii111�Ii:� JMULCH. VERIFY SAUCERI L TYPICAL GROUNDCOVER PLANTING DETAIL NTS Tr" # Species (federal code) Size inches Current health rating (good, fair, had) Drip line radius - North Duip line Son t1h Drip line East Drip fine Wes, 1 AEHI 2 3.5 good 17 20 20 1S AEHI 19-51 arood 1.1 13 15 18 3 P ME 26-5 good 18 25 15 1S 4 PE '0 Lyood 18 Is 15 15 5 P ME 22-8 good 18 15 15 6 PE 29 flood 18 24.6 15 15 7 P I E 24.5 good 18 25 15 15 8 PS M E 1.8 good 18 15 15 15 9 P ME 21-8 i2ood t S =0 15 15 10 P ME 30-5 good 18 'S 15 15 11 PhE I4-9 goad 1s = 1 35 15 trees on sites Douglas fir, Pseudc suga menzi+esii. P ME horse chestnut. Aesculus hippocastanum, AEHI NOTES: MULCH TREE PIT MIN 5-0" LENGTH X FULL PLANTING STRIP WIDTH BETWEEN CURB AND SIDEWALK (FOR PLANTING STRIPS LESS THAN 6'-0" WIDE) OR PROVIDE 5-0"DIA MULCH RING FOR PLANTING STRIPS WIDER THAN 6'-0". STAKE TREE WITH (2) TREATED 2" LODGEPOLE PINE DOWLED TREE STAKES (8'-0" LENGTH) LOOP EACH TIE AROUND HALF TREE LOOSELY TO PROVIDE 1" SLACK FOR TRUNK GROWTH. "CHAINLOCK" OR EQUAL TREE TIE MATERIAL (1" SIZED) NAIL OR STAPLE TREE TIE MATERIAL TO STAKE TO HOLD VERTICALLY. LOOP EACH TIE AROUND HALF - TREE LOOSELY TO PROVIDE 1" SLACK FOR TRUNK GROWTH. 2"-3" MULCH DEPTH (TAPERED AT TRUNK) SIDEWALK 18" ROOT BARRIER AT SIDEWALK ROUGHEN SIDES OF PLANTING HOLE TO MAXIMIZE EXCAVATED AREA WITHOUT UNDERMINING ADJACENT PAVING/CURB ROOT BARRIER; PLACE AT EDGE OF PAVEMENT/SIDEWALK/ETC.; PLACE PRIOR TO PLACEMENT OF NEW SIDEWALK OR CURB TO PREVENT UNDERMINING. TOP SOIL TYPE B, OR AS ' APPROVED BY ENGINEER. REMOVE ALL WIRE, STRINGS, AND OTHER NON -BURLAP MATERIAL; AND REMOVE BURLAP FROM TOP 2/3 OF ROOTBALL. CL �I 2'-0" MIN2" S-6" MIN MIN WIDTH OF TREE PIT = 2 TIMES ROOTBALL DIAMETER _ OR 5-0", WHICHEVER IS GREATER MULCH AREA TO BE CLEAR OF GRASS, WEEDS, ETC. TO REDUCE COMPETITION WITH TREE ROOTS NOTES: 1. PLANTING INCLUDES REMOVAL OF STAKES ONE YEAR AFTER INSTALLATION. 2. SHAPE SOIL SURFACE TO PROVIDE 3" DIAM WATERING RING. 3. TREE CLEARANCE SHALL BE PER STD PLAN NO 030. 4. SEE STD PLAN NO 424 FOR TREE PIT DETAIL. 5. ADJUST TREE TIES DURING ESTABLISHMENT TO ALLOW ROOM FOR GROWTH (@ 1" SLACK). 6. ROOT BARRIER REQUIRED ALONG EDGE OF ROADWAY, CURB, DRIVEWAY, TRAIL, SIDEWALK, OR OTHER STRUCTURES WHERE ROOTBALL IS WITHIN TWO FEET; PLACE VERTICAL ROOT BARRIER AS SHOWN IN STANDARD PLANS 424A OR 424B UNLESS OTHERWISE INDICATED IN THE CONTRACT OR DIRECTED BY THE ENGINEER. SET TOP OF ROOT CROWN 2" ABOVE ADJACENT CURB & SIDEWALK GRADE. 3" TO 4" HIGH WATERING RING (SEE NOTE 2) 24" ROOT BARRIER AT CURB. DECIDUOUS TREE PLANTING IN PLANTING STRIP NTS TREE PIT DEPTH = ROOTBALL DEPTH (MEASURE BEFORE DIGGING TO AVOID OVEREXCAVATION). DRIVE STAKES 6" TO 1'-0" INTO UNDISTURBED SOIL BELOW ROOTBALL. DRIVE STAKE AT ROOTBALL EDGE (TYP) (SEE NOTE 1) UNDISTURBED SUBGRADE (PROVIDES FIRM BASE SO THAT ROOTBALL WILL NOT SINK. STANDARD PLAN NO 100a, CITY OF SEATTLE 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL OTHER SITE I MPROYEMENTS AND CONDITIONS PRI O TO 5TARTING LANDSCAPE WORK. 2. CONTRACTOR SHALL USE CAUTION WHILE EXGAVAT I N6 TO AVOID DISTURBING ANY UTILITIES ENCOUNTERED. CONTRACTOR 15 TO PROMPTLY ADV 1 SE OWNER OF ANY DISTURBED UTILITIES. LOCATION 5ERV I GE PHONE I -aOO-424-5555. 5. CONTRACTOR SHALL MAINTAIN AND WATER ALL PLANT MATERIAL FOR I YEAR OR UNTIL FINAL INSPECTION AND ACCEPTANCE BY OWNER. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING allANT I T I ES OF PLANTS THAT ARE REPRESENTED BY 5YMBOL5 ON THE DRAW I N&. 5. 5UBGRADE 15 TO BE WITHIN 10 -L INCH OF I FOOT AS PRO\/I DED BY OTHERS. ALL PLANTING AREAS TO BE CLEARED OF ALL CONSTRUCTION MATERIAL AND ROCKS $ STICKS LARGER THAN 2 INCH DIAMETER. 6. 4 INCH DEPTH TOPSOIL IN LANDSCAPE AREA. 7. 2 INCH DEPTH, 2 FOOT DIAMETER BARK RING AROUND BASE OF STREET TREES AND OTHER TREES LOCATED IN LAWN. 5. GROUND COVERS SHALL BE PLANTED IN AN EGU I LATERAL TR I ANGULAR SPACING PATTERN AT THE ON -CENTER DISTANCES SHOWN ON THE PLAN OR IN THE PLANT SCHEDULE. WHERE GROUND COVER ABUTS CURBING, 511DEWAL<S, SIGNS OR POLES, MINIMUM PLANTING DISTANCES SHALL BE 12" FROM CENTER OF PLANT TO CURB, S 1 DEWALK, ETC. MINIMUM PLANT I N6 DISTANCE SHALL BE 24" FROM CENTER OF TREES AND SHRUBS. q. ALL PLANT MATERIAL SHALL BE FERTILIZED WITH AGRO TRANSPLANT FERTILIZER 4-2-2 PER MANUFACTURERS SPECIFICATIONS. 10. ALL PLANT MATERIAL SHALL CONFORM TO AAN STANDARDS FOR NURSERY STOCK LATEST EDITION. ALL PLANT MATERIAL FURNISHED SHALL BE HEALTHY REPRESENTATI \/ES, TYPICAL OF THEIR SPECIES OF VARIETY AND SHALL HAVE A NORMAL GROWTH HABIT. THEY SHALL BE FULL, WELL BRANGHEID, WELL PROPORTIONED, AND HAVE A VIGOROUS WELL DEVELOPED ROOT SYSTEM. ALL PLANTS SHALL BE HARDY UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN THE LOCALITY OF THE PROJECT. TREES, SHRUBS AND GROUNDCOVER aUANT I TI ES, SPECIES, VARIETIES, SIZES AND CONDITIONS TO BE AS SHOWN ON THE PLANTING PLAN. PLANTS TO BE FREE OF DISEASE, INJURY, INSECTS, DEGAY, HARMFUL DEFECTS AND ALL WEEDS. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM LANDSCAPE ARCHITECT O OWNER. 11. NO PERMANENT IRRIGATION 5YSTEM 15 PROPOSED. TEMPORARY IRRIGATION SHALL BE REOU I RED FOR THE FIRST 5 YEARS OR UNTIL PROPOSED PLANT MATERIAL 15 ESTABL I SHED. PLANT MATERIAL SPECIFIED TO BE NATIVE OR DROUGHT TOLERANT AS DETERMINED BY LANDSCAPE ARCHITECT. 12. THE AVERAGE SPAG I N6 FOR STREET TREES SHOULD BE 40 FEET ON CENTER AND ADJUSTED TO ALLOW FOR SIGHT LINES, UTILITIES, TRAFFIC 51 GNS, LIGHT STANDARDS, DRIVEWAYS AND OTHER STREET APPURTENANCES. 15. TREES IN THE RIGHT OF WAY MUST BE PLANTED TO THE FOLLOWING STANDARDS: PLANT TREES IN THE CENTER OF THE PLANTING STRIP WIDTH. 6 FEET FROM FIRE HYDRANTS AND UNDERGROUND UTILITIES 00> WATER, SEWER, ELECTRIC, GAS). 10 FEET FROM UTILITY POLES, DRIVEWAYS, AND ALLEY MARGIN, 25 FEET FROM STREET LIGHTS, 40 FEET FROM THE CORNER OF INTERSECTIONS, STOP 5I GNS, AND YIELD SI GNS. AT LEAST 72 HOURS BEFORE YOU PLAN TO DIG, YOU MUST GALL 811 TO REQUEST THAT THE LAST LOCATION OF ANY UNDERGROUND OR OVERHEAD UTILITIES (GAS, WATER, ELEGTRI G, ETC.) BE MARKED ON YOUR PLANTING AREA. <NOWI NG THESE LOCATIONS IN ADVANCE MAY SAVE YOU TIME AND MONEY BY PREVENTING AN ACCIDENT. d) # U- p � •� 4z C: Z 1- M �� 0)1It � ri U- A) -6 O 4-1 � 10 O Nr0) PROJECT TITLE State of Washington registered Landscape Architect Pevin Peterson certificate no. 1222 Z a a J � a Z O W W a LU Q N N a H Z a 0 N J N NG I.II.117 NG E D 03.16. J 1 REVISED DATE REVISED DATE L2 R-398018