HomeMy WebLinkAboutR-398008Z
N
(0
T
W
co
M -
S1° 31 39.44„W!I
114TH AVE SE
STA +00 = SE 162ND STA 10+00
CONIC MONUMENT W/ BRASS -
N 170084.65 9 -
E 1305087.02 °
a
a a
°
J Jj
�r-9z�0)
Cn Oj O
ZNN �I�
° O o O
=1
c�i�CDC-O �z00z
° Q
ill
Q STA 21 +51.68, 13.00' LT
m L 16 IDE DRIVEWAY
z0-) SEE SHEET C5 FOR
O ( ONSITE UTILITY PLANS
W O I� O
U� N �0 1 LINE (TYP)
J 1
RIQIECT EX UTILITY POLE �
4' WIDE ACP LANDING 1
SLOPE AT 2.0% MAX
ACP RAMP, SLOPE AT 12• -T
MAX, MATCH EX GRADE
\ CB #5 1
3 1
„ D
0 00
E- Ir2�-e�m ! m
_ !m
j FILL AND GRADE TO DRAIN !
ELEC CABINET, !
I SEE LIGHTING PLANS
1
�2+00#6 i rn
m
STA 21 +79.12, 13.00' LT
END CURB AND GUTTER AND PROJECT SIDEWALK
STArr'k1f77.12. 42.24' LT
1
1
1
1
1
1
J
m
'
.......... _
N
......
Lin
1
. . . . . . . . . . CV
cV
W
CV
�_
485
..........,.
.......... ; p w
.......
c w ...... a'
w
w
o
. . . . . .
..EX CENTERLINE
i
�� L
+ p�
o��___ _r
+ C68+
rnp a;
060-) r-
�p
rn
cflr7
GRADE
!
p. 00 00 �
a
EX GRADE AT ROADWAY
N co s N
¢ Q
� 4 � +
w N
�
+ m
N c�
� �
CO�
REMOVE EX 12"1
1
c~i� U iY !�'
CENTERLINE
PROPOSED
TOP
OF CURB ELEVATION
cn m i� LEI 00
z E w
�
CULVERT
Ln
w
1.
480
............
...............
1
FILL AND GRADE
-
1
-
.
-030%
��
TO DRAIN
45 LF 12" DI SD 1.0%
Q
EX
- - ...........
- ....
-
�q�
.:
- -
- -
i m
O
.............................................................
6"SS, FIELD VERIFY ELEVATION
......�.
.....
... .....
.. ........'
rn
......
. .................
PRIOR TO CONSTRUCTION
� .. �:..-.- ._
—
14 LF �,
— ------
1(A
475
...
.-
• %
L12
FIELD VERIFY ELEVATION OF EX 8"
I ..........
1 ITI
WATER MAIN PRIOR TO CONSTRUCTION
I
m
TO ENSURE 6" CLEARANCE FROM
470
PROPOSED 12" SD, NOTIFY ENGINEER
OF POTENTIAL CONFLICTS
EX 6" SS, FIELD VERIFY ELEVATION ...
..
1
-
o
PRIOR TO CONSTRUCTION
0
-
U
o
p
W
SAME STRUCTURE CB
6
1
cn
z
�-'
SAME STRUCTURE CB #5
1
465
�
�,
p
,�
O
475
1
�w
a_
1
g1
-
+mo,�
N C.�
1.
460
00
470
15 LF 12''
L" � �
w
SD 2.00% O
i
STA 21 +93.00, 17.5' LT
1
48" CB #6 TYPE 2 W/ SOLID LID
!
455
RIM 479.15
1
IE 473.73(N), 469.93(SE), 476.55(8" NE)
1
M0)
C�o
OOr?CR
co
1`-�N!n
C�o co
CO
Lnpr
00
LgpcV
00
m
00
m
00 m
00 m
06 O
00 ai
450
���
mF-m
���
mom
c)��
mom
���
mom
���
mom
���
mom
20+00
20+50
21+00
21+50
22+00
Know what's below.
Call before you dig.
co.:,erra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
114TH AVE SE PROFILE
SCALE: HORZ. 1 " = 10' VERT. 1 " = 5'
7 SHARED DRIVEWAYS
6 CITY COMMENTS
5 CITY COMMENTS
4 CITY COMMENTS
NO. REVISION
SURVEYED:
MB
3 29 17
PA
DESIGNED:
MB
MB
9 09 16
PA
MB
8 15 16
PA
DRAWN: MB
MB
7 07 16
PA
CHECKED:
PA
BY
I DATE
I AP P R
APPROVED:
SCALE:
1 a_ 10,
HORIZONTAL: N D 11983/1991
ONE INCH DATUM
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
Egm
2N
475
NOTES
1. SEE SHEET C1, C2 & C12 FOR GENERAL NOTES AND ROADWAY DETAILS.
2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C13.
3. SEE SHEET C11 FOR ROADWAY SECTIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE
PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS
AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT
COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BEYOND
THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF
THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL
EXISTING INFORMATION AND TO FURTHER DISCOVER AND AVOID ANY OTHER
UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE
AFFECTED BY THE IMPLEMENTATION OF THESE PLANS.
5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND
ASSUMED CONFIGURATION. THE CONTRACTOR SHALL UNCOVER ALL PIPING
WHERE CROSSING, INTERFERENCES, OR CONNECTIONS OCCUR PRIOR TO
TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE
ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE THE
APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL
ADJUST WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED
CLEARANCES.
6. COORDINATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACCESS
IS MAINTAINED AS REQUIRED.
7. PROTECT UTILITIES TO REMAIN.
8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO
CURRENT CITY OF RENTON STANDARDS.
9. THE DITCH AREA WILL BE RE -GRADED TO ALLOW THE CATCH BASINS TO
COLLECT FROM FROM THE ROADWAY AND THE ADJACENT PRIVATE
PROPERTY AND WILL BE PLANTED WITH GRASS. EDGE OF PAVEMENT TO THE
EXISTING DITCH LINE SHALL BE AT A SLOPE OF 6: 1. MAX.
LEGEND
-- 1
CB TYPE-1 C14
\� CB TYPE-2 48" C 14
- - - - - - - STORM DRAIN MAIN
SANITARY SEWER MAIN
SANITARY SERVICE LINE
— WATER SERVICE LINE
WATER/FIRE MAIN
ASPHALT CONIC
PAVEMENT
470
CEM. CONC.
PAVEMENT
465
PERVIOUS 3
CONCRETE C 15
460 SIDEWALK
455
- - - - - - - - SAWCUT LINE
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY
DEVELOPMENT ENGINEERINGn,77
rstraka 06/20/2017 'rianne
B Bannwarth 06/22/2017
CONSTRUCTION PERMIT SUBMITTAL
DATE: n
�% CITY OF L I M E L I T E SHORT PLAT FlELD3/29/17
IMU
REN TON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
Planning/Building/Public Works Dept. DRAWING NO:
FRONTAGE IMPROVEMENTS 114TH AVE SE
R-398008