DRIVEWAYS SHALL BE PAVED TO THE EDGE
OF R-C-W PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO AVOID
EX1SA"AGPOPO
/
DAMAGING OF THE ROADWAY
IT IS RECOMMENDED THAT THE
R = 25' MIN.
ENTRANCE BE CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
moo.
y2
INSTALL DRIVEWAY CULVERT IF THERE
IS A ROADSIDE DITCH PRESENT, AS
PER CITY ROAD STANDARDS
4"-8- QUARRY SPALLS
GEOTEXTILE
sy
12' MIN. THICKNESS PROVIDE FULL WIDTH OF
NOTES INGRESS/EGRESS AREA
1. CONDITION OF USE
1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON
PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE.
GRAB TENSILE STREBNGTH(ASTM D4751)
1200 PSI MIN.
GRABTENSILEELONGATION(ASTM D4632)
30%MAX.
MULLEN BURST STRENGTH (ASTM D3786-80A
400 PSI MIN.
AOS (ASTM D4751)
20-45 (U.S. STANDARD SIEVE SIZE)
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED
FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY
AT ANYTIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO
PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY
INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE
STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE
ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH
CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY
SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET,
EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A
SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND
DISCHARGED APPROPRIATELY.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE
INSTALLED TO CONTROL TRAFFIC.
e
PUBLIC WORKS STABILIZED STD• PLAN - 215.10
DEPARTMENT CONSTRUCTION ENTRANCE
MARCH 2O08
STABILIZED CONSTRUCTION ENTRANCE
5' MAX.
DRAINAGE GRATE
GRATE FRAME
3
4 d
� D
SEDIMENT AND DEBRIS -�
OVERFLOW BYPASS
• b "„7;:'•` o P BELOW INLET GRATE DEVICE
FILTERED
WATER
° p d
p p
SECTION V IE W
DRAINAGE GRATE
- REC'
ISOMETRIC VIEW
NOTES
1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service.
2. The BIGD shall have a built -In high -Flow relief system (overflow bypass).
3. The retrieval system must allow removal of the BIGD without spilling the collected material.
4. Perform maintenance In accordance with Standard Specification 8-01.3(15).
EM (TYP.)
Y
*� + PUBLIC WORKS CATCH BASIN FILTER STD. PLAN - 216.30
`8 DEPARTMENT
�d'AiTO� MARCH 2O08
CATCH BASIN PROTECTION
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
EQUIVALENT TO ATTACH FABRIC TO POSTS.
POST SPACING MAY BE INCREASED
TO 8' IF WIRE BACKING IS USED
2"I2" BY 14 Ga. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC
BACKFILL TRENCH WITH
NATIVE SOIL
2"X4• WOOD POSTS, STEEL FENCE
POSTS, REBAR, OR EQUIVALENT
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
30-100 SIEVE SIZE IDrAD.15MM) FOR SILT FILM
ADS (ASTM D4]51)
'0 RXIS1EVE SIZE 10.30O.15MM) FOR OTHER FABRICS
WATER PERMITTIVITY ASTM D4911
0.025EC^-1 MINIMUM
GRAB TENSILE STRENCHT(ASTM D4632)
180 LBS. MIN. FOR EXTRA 5TRENGH FABRIC
300 LBS. MIN. FOR STANDARD STRENGHT FABRIC
GRAB TENSILE ELONGATION(ASTM D4632)130%MAX.
ULTRAVIOIATE RESISTANCE (ASTMD4355)170%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNEL17ATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
Y
pt� O n
+ + PUBLIC WORKS SILT FENCE STD. PLAN - 214.00
DEPARTMENT
�FN.fO� MARCH 2O08
FILTER FABRIC FENCE
NTS C12 NTS C12 NTS
-� FACE OF CURB 6" CEMENTCONCRETE
11T R. 1"R. - SIDEWALK RAMP
6t/2 VARIES _ I OR LANDING
51/2" 1" FROM T
6- TO D
TOP OF
i(' ° • n
° Fcl� ROADWAY - JOINT FILLER
D
12' R. / JOINT FILLER
CEMENT CONCRETE
PEDESTRIAN CURB
° AT SIDEWALK RAMPS AND LANDINGS
1,-6"
FACE OF ADJACENT CURB
CEMENT CONCRETE 6112" -'
TRAFFIC CURB AND GUTTER SEE DEPRESSED CURB DETAIL THIS SHEET
' _r FACE OF ADJACENT CURB 1:24
TOP OF
6 112_ .'
- FLUSH WITH GUTTER �- �1" 12"R. ROADWAY
�- PAN AT SIDEWALK 2"
RAMP ENTRANCE D
1:12 / - 1:24 °
TOP OF ° D
112• R./ ROADWAY
DEPRESSED CURB SECTION
• ° DP "I AT RESIDENTIAL DRIVEWAYS ONLY.
ICI \\!l FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 1042
DEPRESSED CURB SECTION FACE OF CURB
AT SIDEWALK RAMPS
611T
5 112' L 1"
112"R. 1"R.
FACE OF ADJACENT CURB T TOP OF
o ROADWAY
GUTTER SURFACE
_L- •
D B 114" I
1" R. D , CEMENT CONCRETE
° ' '• TRAFFIC CURB
• D
DEPRESSED CURB DETAIL
AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS
GENERAL NOTES:
1. See standard plans 102 and 101.1 for curb expansion and Contraction joint spacing.
2. Not used.
3. For Depressed Monolithic Driveway Curb 8 Gutter Section, see Standard Plan 104.2
PUBLIC WORKS STD. PLAN 101 -
DEPARTMENT CEMENT CONCRETE CURBS PR 'ED
F1VT0 It
',A*
CURB AND GUTTER DETAILS
NTS
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
7 n' AAINI .._... _..__
EXIS IING ASPHP
PAVEMENT
SAWCUT
(SEE NOTE 2)
R
7" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
RESIDENTIAL STREET MINIMUM
4" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
NOTES:
1. MUST MATCH EXISTING THICKNESS IF GREATER,
2. SAWCUT SHALL BE POSITIONED 1' - 0" BEYOND EDGE OF
DAMAGED PAVEMENT.
3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT
PLACEMENT AT THE GUTTER FACE. SEE STANDARD PLAN
FOR CEMENT CONCRETE CURBS.
STD. PLAN - 103
* PUBLIC WORKS CURB AND GUTTER PPRO D:
DEPARTMENT REPLACEMENT DETAIL y
ATE
CURB AND GUTTER DETAIL
KITC
7 SHARED DRIVEWAYS
6 CITY COMMENTS
5 CITY COMMENTS
4 CITY COMMENTS
NO. REVISION
STREET/CONTROL
L
30,
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY DEVELOPMENT ENGINEERING
PROP. rstraka 06/20/2017 0 Brianne Bannwarth 06/22/2017 0
ROW
13' 8.5' 5' 3.5'
STREET PLANTER SIDEWALK
TOP OF CURB
(PROFILE POINT)
EXISTING GRADE (TYP)
2.0%
4 3
ASPHALT PATCH 5" PERVIOUS CONCRETE SIDEWALK
C15 C15
4 CURB AND GUTTER PER 8" TOPSOIL, HYDROSEED OR SOD
C 1 COR STDS
BE 162ND ST TYPICAL ROADWAY SECTION
J NTS
STREET/CONTROL PROP.
CL ROW
1 30' 1
13' 8.5' 5' 3.5'
STREET PLANTER SIDEWALK
TOP OF CURB
(PROFILE POINT)
EXISTING GRADE (TYP) 2 0%
111III111 lllii
4 ASPHALT PATCH 5" PERVIOUS CONCRETE SIDEWALK 3
C15 C15
4 CURB AND GUTTER PER 8" TOPSOIL, HYDROSEED OR SOD
C 1 COR STDS
114TH AVE SE TYPICAL ROADWAY SECTION
NTS
BIDITEIA RAxUDESSIDEWADIRA!
e wN
-FRE.ISEE NOTE TI 6 I,
MEN
V
CO DCTK`I` ff ,
SEE NOTE CENENTCONcgETE
R1r.1P WIiN laity
SLOPE (IYP.)
B CUF GU F
ISEE NOTE 11
YB' CONTRACTION 10w (M.)
(SEE STD. PL ui
uul PLAN VIEW
VAME9
'-ISEE NO'F TDI el%MAX.
SEENOTESIT ,
.I
craw c• MN
fi' M11N
CENENi CONCRETE MESToP IIWI RYPI
smEwaaK 6ECTION O ISEE Sio. vtAN t@i
\ a.amP.l
'
REPRESSED LURE d GUliER
Id!l NDR ]I
eoEWax mDw
. DIFFERENCE IN SLOPE
r.Nx -
DNVEWAY WI rNE SLOPE (SLOPE SHOWN EXAOCFMTE01
1]%
',�
-
t ia,
• DIIIVEV AY
/
Y Hw
DRIVEWAY W. RELATIVE r
° sE ON O
NE TNESLOPE fSL
SHOWNEXIGG Met
i
- CEMENT CONCRETE
CURS d GUTTER
(SEE NOTE 3)
rl
CEMEM
CONCi
.1ae uc
_ OMTN'C
ETAa Si0 PLAN tw]I
TYPE R1B -ISOMETRIC VIEW
(RESIDENTIAL WITH BUFFER)
For NOTES STD. PLAN 104.2
STD. PLAN - 104.3
a `
PUBLIC WORKS
CEMENT CONCRETE DRIVEWAY
PPP. \'FD:
DEPARTMENT
ENTRANCE -TYPE RIB
�, m � Z
NT
A-;
{SEE NOTE al
ISEE NOTE e)
ID U Of PAVED
oalvswer gEouweo
Ld'EXPANSIONIAMj!]'P4
cE
(SEE SiD. PLAN 1@I
COMCREIE
snEwux
iBEE
NCtE s
e
m
=
Gregg Zimmerman, Public Works Administrator
y..¢„�\ \ ~•�' \�`�� CEMENT CONCRETE
`- CURB 8 GUTTER
J / (SEE NOTE 3)
CEMENT / % DEPRESSED MONOLITHIC
CONCRETE -,
SIDEWALK
CURB AGUTTER
(BEE DETAIL THIS SHEET)
�`
• w4%�
TYPE C2B - ISOMETRIC VIEW
(COMMERCAAt, WITH BUFFER)
NOTES
1. When a driveway width exceeds 15 feet, construct a full dep'J)
expansion Joint with 3/8' Joint filler along the driveway lane lines
FACEGFICURB
(see aid, plan 102). Construct expansion joints parallel with Lite
�© a1¢ own DEPRESSEDHIS HCURB DETAIL
centedlne as required at 15' maximum spacing when driveway
COKTRACTtON JOINT
STO PUN 102
widths exceed 30',
a� r ,
b 1lrR TaPaF
/ ROADWAY
2. See std. plan 102 for sidewalk details,
-� a
jL
3. Curb and gutter shown, other curb designs may be specified.
,j�
%" '• '
See std. plan 101 for curb details.
4. Not used.
�-
1'-Ir
5. The engineer will design all driveways to Include elevations at all
NOTE: DRIVEWAY LONcrruDINAL!!oANSION
points marked with symbol "X". All elevations Bra at the back of
JDINTB stvu BE FUC=RB H
DEPRESSED MONOLITHIC CUI� &GUTTER DETAIL
curb top on uphill side
6. Not used.
7. For Driveway Widths sea DRIVEWAY STANDARDS
(See NOTE 10). The expansion joints (see std. plan 102) shall be
spaced as shown In the corresponding Isamelrlc view.
8. Slopes shall Comply with seCSlons R303.2.1 Or R303.2.2 Or
- FACE OF ADJACENT CURB
R303.2.3 of the Revised Draft Guidelines for Accessible Public
Rights November 23, 2005
\ 1"
-of -Way of (PROWAO).
9. Curb reWme for any Type C-MAX Driveway may be approved on
a case -by -case basis.
', yo fit. R ACE
10. STREET STANDARDS = Renton Municipal Code (RMC)
Title IV Development Regulations
CHAPTER 5 STREET AND UTILITY STANDARDS
Section 4-6-060 STREET STAN DARDS
DEPRESSED CURB DETAIL
AT RESIDENTIAL ORCOMhERCULL DRIVEWAYS, AND ALLEYS
DRIVEWAY STANDARDS = Renton Municipal Code (RMC)
Title IV Development Regulations
_
Driveway Example: TYPE C1B
CHAPTER 4
R=Resldensd, C--Gomm cw
CITY-WIDE PROPERTY DEVELOPMENT STANDARDS
1}
Number of Laren,
Section 4-4-080 PARKING, LOADING AND DRIVEWAY
(MAx=4 Lane Commerrtaq
REGULATIONS
B-Bufter(Renting Strip), Blank-NoSuffw
PUBLIC WORKS
CEMENT CONCRETE DRIVEWAY
D - 104az
R 'V
DEPARTMENT
ENTRANCES - NOTES AND DETAILS
Arr
s DRIVEWAY DETAILS
C12 NTS
SURVEYED: SCALE: CONSTRUCTION PERMIT SUBMITTAL ��
w� f HORIZONTAL-TICAINAD 1983/1991 4► 3/29/17
MB 3 29 17 PA DESIGNED: 10•� CITY OF L I M E L I T E SHORT PLAT FIELDBOOK:
MB 9 09 16 PA MB RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
MB 8 15 16 PA DRAWN:
MB DRAWING N0:
MB 7 07 16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE Planning/Building/Public Works Dept. CML DETAILS C1
If NOT ONE INCH
BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: OR
R-398012