Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutR-3980131'-01 1'-0'-- SEE CONTRACTI
ROU PING 20"° 1) 1?pM R. (TYP.I
CURB NOT INCLUDED IN BID ITEM -
IN)
SEE RAISED EDGE " 3'S' IIW PREMOLORJ.EREG .. J•�
r-0' SIDEWALK DETAIL - THIS SHEET J.,NTF
SLLCUT :QN,
(SEECONTRACTI
SL`PES
1rz• DN) R. (rvP.l WITH RAISED EDGE
1 1sXURSNOTINNGTrN
auDEDmeIomEM-
NOR�� _
bH�.Ft6TL .. ..
F
3.e (INI PREMOLOEO ,,> FINISHED GRADE 1- IN) BELOW
JOINT FILLER - TOP OFCONCRETE SURFACE
7-C' SIDEWALK
ADJACENT TO CURB 1' D' 1' 0' MR. (SEE CONTRACT)
RnU nING Irz"t"R(IYP.)
_2.0'n 1 5%__� % CURB NOT INCLUDED IN BID rtEM -
1,
` are ItN '�
BRIDGE OR PEDESTRIAN PRNT FILLER
- WALL OR BARRIER
RAILING JOINT FILLER
ADJACENT TO CURB
BARNIER-BEE SIDEWALK (STEEP FI.L SLOPESI
COWRACT PLANS (BEE CO WRACTI WALL OR BARRIEf
J I H2- QN1 R. (TYP.I
FLUSH J I 15% CURB NOT INCLUDED IN BID ITEM- SIDEWALK
rr,ir. v. s T-t' Irr
VERTICAL WALL- 1'e'tlM) PREMOLDED
SEE DETAIL JOINT FLLLER(TYP.I •'�
ADJACENT TO CURB AND RAILING OR WALL 3T (IN) PREMOLOE0
JOINT FILLER
SIDEWALK BUFFERSTRIP
(SEE CONTRACT) fSEE NOTE1101
1a- IINI R. SIDEWALK ADJACENT TO WALL DETAIL
V (TYPA CURBNOTINCLUDEDeIBIDrTEM-
' �S.u-:i'w�5r•�:i LEVEL
112-IINI R. �7I
FINISHED GRADE 1- pN) BELOW TOP OF CONCRETE
SURFACE FOR PLATING - FLUSH IF PAVED e
ADJACENT TO BUFFER STRIP 0"� 1-RM R. ,!►•rr•'.e
BROONIC-0FINISH ' , �' •
4'WIDE SMOOTH
aA A'•u TROWELED PEFOMETER ABED EDGE DETAIL
t` • E%TEND SIDEWALK TRANSVERSE
0" JONTS TO INCLUDE RAISED EDGE
CEMENT CONCRETE CURB
,�- ICURS AND GUTTER SHOWN]
NOT INCLUDED IN BID ITEM
For NOTES see STD PLAN 104.2.
j Paved surfaces must comply with
STD PLAN 102.1 as applicable.
3IS' � 11B'T01N'
CO W RACTION JOINT
IN SIDE WALK ONLY
ee '
_ EXPANSION JOINT IN BOTH .•B �'e ?, TO'�' .•� �Br0'e
CURB AND SIDEWALK (SEE STD PIAN 101U
JOINT AND FINISH PREMOI E
JOINT FILLLERR
DETAIL
-:X) EXPANSION JOINT ©CONTRACTION JOINT
Y
PUBLIC WORKS CEMENT CONCRETE M. PLAN - 102
DEPARTMENT SIDEWALK PPRO rED:
TE
OEM. CONC. SIDEWALK
NTS
Gregg Zimmerman, Public Works Administrator
LANE LINE
MARKING 7,
8„
STANDARD VEHICLE WHEEL PATH
-
MIN.
1'-
MIN.
2" CLASS 'B'
2" SAWCUT AND REMOVE
OR GRIND, SEAL WITH
AR4000W
- 4.5'
3'
MIN.
MIN.
1' ACP CLASS*
MIN.
6" CRUSHED
SURFACING TOP
COURSE
EDGE OF PAVEMENT, -
EDGE OF CURB & GUTTER,
OR CENTER OF LANE LINE
J\
2.5'
MIN.
CRUSHED ROCK, FLOWABLE FILL
OR AS REQUIRED BY ENGINEER
*MINIMUM ACP CLASS 'E' or 'B' SHALL BE:
PRINCIPAL/MINOR/COLLECTOR ARTERIAL STREETS & INDUSTRIAL
ACCESS STREETS - 6" ACP CLASS 'E' or 'B'.
RESIDENTIAL ACCESS STREETS - 2" ACP CLASS 'E' or 'B'.
NOTE:
UPON REQUEST OF ENGINEER, NEW ROADWAY PAVEMENT
SECTION MAY BE DESIGNED USING AN APPROVED METHOD FOR TYPICAL LONGITUDINAL PATCH AND OVERLAY
DETERMINING PAVEMENT THICKNESS. FOR FLEXIBLE PAVEMENT
Gt�Y o� ADOPTED
CITY OF RENTON
..
STANDARD PLANS
LIT DATE: 02/05
02 ZOOS MODIFlED NOTES My DC
07 2004 1 MODIFlED NOTES Dcv Gz
DATE REVISION BY PPR D DWG. NAME: H032 SP PAGE: H032
PAVEMENT RESTORATION (LONGITUDINAL)
NTS
cotc,"ra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
p A CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH
o CURB RAMP WIDTH -• SEE CONTRACT PLANS
of w i I
LL LANDING GRADE BREAK LANDING
to GRADE BREAK SEE CONTRACT PLANS - CURB RAMP
I 4' - 0" MIN. CEMENT CONCRETE SIDEWALK -
SEE CONTRACT PLANS - I SEE NOTE 5
4'- 0" MIN. PROVIDE SMOOTH
CEMENT CONCRETE TRANSITION TO
SIDEWALK
SIDEWALK-' SEE NOTE 5 I WIDTH (TYP.) SEE CONTRACT PLANS-
2.0 I MAX. 4, _ 0"� IN.
FLARE (TYP.) 3/8" EXPANSION
JOINT (TYP.) - SEE ,
3/8" EXPANSION I CURB RAMP STANDARD PLAN F-30.10
JOINT (TYP.) - SEE
STANDARD PLAN F-30.10 GRADE V11
BREAK I TRANSITION TO SIDEWALK BUFFER, IF
GRADE BREAK PRESENT, OR TO BACK OF CURB (TYP.) -•
- _ 10.046 °'0°'E'pppp°0°° SEE CONTRACT PLANS , ,
- MAX. iiiiiiiiiiEii' •iiii 10.oMo MAX.MAX v„
CURB, OR CURB
AND GUTTER - CURB, OR CURB
SEE NOTE 4 AND GUTTER -
DETECTABLE WARNING SURFACE - SEE NOTE 4 D
SEE STANDARD PLAN F-46.10
FACE OF CURB FACE OF CURB
MEASURED PARALLEL DEPRESSED CURB AND GUTTER •-
TO CURB (TYP.) CROSSWALK SEE NOTE 4
PLAN VIEW
TYPE PERPENDICULAR A
DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F-45.10
4'- 0" MIN. 15 - 0" MAX.
SEE CONTRACT PLANS SEE NOTE 7
GRADE BREAK
2.0% MAX.
8.3% MAX.
LANDING CURB RAMP 'v
SLOPE TREATMENT -
SEE STANDARD PLAN F-30.10
SECTION O
CURB RAMP W/ WINGS
NTS
NOTES
��^ J CURB RAMP WIDTH 4'- 0" MIN.
1. Provide a Separate Curb Ramp for each marked Or unmarked crosswalk.
LANDING TO MATCH CURB RAMP
WIDTH -SEE CONTRACT PLANS
Curb Ramp location shall be placed within the width of the associated
crosswalk or as shown in the Contract Plans.
GRADE BREAK
2. Where "GRADE BREAK" is Called out, the entire length of the grade
break between the two adjacent surface planes shall be flush.
3. Do not place Gratings, Junction Boxes, Access Covers, or other appurte-
nances in front of the Curb Ramp or on any part of the Curb Ramp or
SEE CONTRACT PLANS -
Landing.
MIN. 4 - 0" MIN.
2.01d MAX.
4. See the Contract Plans for the curb design specified. See Standard Plan
BUFFER WIDTH - MATCH TO
F-10.12 for Curb. Curb and Gutter, Depressed Curb and Gutter, and
V., CURB RAMP DEPTH (TYP.)
Pedestrian Curb details.
1 ar,
5. See Standard Plan F-30.10 for Cement Concrete Sidewalk details.
\i
See Contract Plans for width and placement of sidewalk.
6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include
the adjacent Curb. Curb and Gutter, Depressed Curb and Gutter,
/
Pedestrian Curb, or Sidewalk.
CEMENT CONCRETE
PEDESTRIAN cuRe -
7. The Curb Ramp maximum running slope shall not require the ramp length
I SEE NOTE 4
to exceed 15-feet to avoid chasing the slope indefinitely when connecting
DETECTABLE WARNING SURFACE -
to steep grades. When applying the 15-foot maximum length, the running
SEE STANDARD PLAN F-45.10
slope of the Curb Ramp shall as flat as feasible.
DEPRESSED CURB AND GUTTER
8. Curb Ramp, Landing, and Flares shall receive broom finish. See
CROSSWALK
Standard Specifications 8-14.
PLAN VIEW
TYPE PERPENDICULAR B
(SHOWN WITH BUFFER) CEMENT CONCRETE
PEDESTRIAN CURB --
GRADE BREAK SEE NOTE 4
COUNTER SLOPE -
5.0% MAX.
TOP OF ROADWAY
DEPRESSED CURB AND GUTTER -
SEE STANDARD PLAN F-10.12
CEMENT CONCRETE CURB RAMP "TYPE
MIT -
ISOMETRIC VIEW
TYPE PERPENDICULAR A PAY LIMIT
IN AREAS OF NEW PAVING, INSTALL
PAVEMENT PER PAVING PLAN
EX PAVING
SUITABLE NATIVE OR
GRAVEL BORROW
COMPACTED IN 8" MAX
LIFTS TO 95% DENSITY
ON PRIVATE PROPERTY
CRUSHED SURFACING
PER WSDOT 9-03.9(3)
OR BANK RUN GRAVEL
PER WSDOT 9-03.19,
IN ROADWAYS AND
PUBLIC ROW
GRAVEL BACKFILL FOR PIPE
ZONE BEDDING PER SECTION
9-03.12 (3), OF THE WSDOT
STANDARD SPECIFICATIONS,
COMPACTED TO 95% DENSITY
6" MIN.
4" MIN.
WIDTH=1.5 x PIPE DIA +
18"MIN FOR 6" W=27"MIN 8"
W=30"MIN 12"W=36"MIN
FLEXIBLE PIPE
LEGEND
SLOPE IN EITHER DIRECTION
DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F45.10
3" R TYP. DEPRESSED CURB AND GUTTER -
SEE NOTE 4
8
CEMENT CONCRETE CURB Q P.'T RICE
AND GUTTER - SEE NOTE 4 4Q OT pASc. 8s.
n n
CURB RADIUS DETAIL O rat
ko PB
ISOMETRIC VIEW
TYPE PERPENDICULAR B PAY LIMIT
'o C'
00 ,Q 34363 �U�
s� �0ISTV,
�"ONAL ECG
$k$.
OHIZ
€m��8
PERPENDICULAR
CURB RAMP
STANDARD PLAN F-40.15-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
Pasco Bakodch M 6/20113
STATE DESIGN ENGINEER GATE
wasbin9ron Sole Department of Transportation
IN AREAS OF NEW PAVING, INSTALL
PAVEMENT PER PAVING PLAN
RESTORE
LANDSCAPE EX PAVING
%" MINUS CRUSHED ROCK -
COMPACTED TO 95% DENSITY
MINUS CRUSHED ROCK
COMPACTED TO 95% DENSITY
PAVEMENT RESTORATION (TRANSVERSE)
/I 1
NTS
6" MIN.
4" MIN.
WIDTH =1.5 x PIPE DIA +
18"MIN FOR 6" W=27"MIN 8"
W=30"MIN 12"W=36"MIN
RIGID PIPE
RESTORE
LANDSCAPE
\\
Cimils of pipe
/ ompaction
-I II
O.IS O.D. min.
]anus of pima
ompacuon Q 0.65 O.0. min.
gravel backfill Dravdetl-fllfar
for pipe bedding fountla0ons when specifietl
A. Metal and Concrete Pipe
T max
0.15 rise min.
climils of pipe
ompadlon �65 rise min.
gravel backfill9ravel backfill for
forpipebedding fountlelions when specified
B. Pipe - Arch Installation
Rigid Pipe NOTES:
1. Pipe compaction limits shown on this plan are for pipe
construction In an embankment. For pipe construction
in a trench, the horizontal limits of the pipe compaction
zone shall be the walls of the trench.
2. All steel and aluminum pipe and pipe -arches shall be
installed In accordance with design A.
3. Concrete pipe with elliptical reinforcement shall be
Installed In accordance with design A.
4. Concrete pipe, plain or with circular reinforcement, shall
be installed with design A.
5. O.D. is equal to the outside diameter of a pipe or the
outside span of pipe -arch. The dimensions shown as
O.D. with 3' maximum shall be O.D. until O.D. equals
3', at which point 3' shall be used.
" T-0" for diameters 12" through 42" and spans through
50". T-O" for diameters greater than 42" and spans
greater than 50".
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILIT
rstraka 06/20/2017Y }
DEVELOPMENT ENGINEERING
Brianne Bannwarth 06/22/2017 '
W (see note 6)
limit of pipe zone
bedding
material
for flexible
pipe I.
note 6)
m O.D.
foundation
level $
A = W min. 27" I.D. and under
6' min., over 27' I.D.
Bedding for Flexible Pipe
Flexible Pipe NOTES:
1. Provide uniform support under barrels.
2. an tamp under haunches.
3. Compact bedding material to 95% max. density; directly
over pipe, hand tamp only.
4. See "Excavation and Preparation of Trench" in sanitary
sewers section of the standard WSDOTIAPWA
specifications for trench width "W" and trenching
options. The pipe zone will he the actual trench width.
The minimum concrete width shall be 1 I.D. = 18".
5. Trench backfill shall conform to "Backfilling Sewer
Trenches" in the sanitary sewers section of the
WSDOT/APWA standard specifications, except that
rocks or lumps larger than 1" per fool of pipe diameter
shall not be used in the backfill material.
6. See "Bedding Material for Flexible Pipe" In aggregates
section of the WSDOTIAPWA standard specifications
for the material specifications.
ILLLLd Backfill material placed in 0.5' loose layers and
compacted to 95% maximum density.
EMMethod B or C compaction (WSDOT/APWA)
standard specifications.)
Pipe
Size
Min. dist.
between
barrels
circular pipe
cone., LCPE, CMP
(diameter)
12" to 24"
12"
30" to 96"
diam. / 2
102" to 180"
48"
pipe - arch
metal only
(span)
18" to 36"
1 12"
43" to 142"
span / 3
148" to 199"
48"
Y
STD. PLAN - 220.00
A� PUBLIC WORKS PIPE COMPACTION
p�R$ DEPARTMENT DESIGN AND BACKFILL
�'NTO MARCH 2O08
5 TYPICAL TRENCH SECTION /6-N PIPE COMPACTION AND BACKFILL
C13 NTS C13 NTS
CONSTRUCTION PERMIT SUBMITTAL
SURVEYED: SCALE. VERTDATE:
a_ f HORIZONTAL NAD 1983/1991 q 3/29/ 17
DESIGNED:
7 SHARED DRIVEWAYS Me 3 29 17 PA MB _ 1 O •• CITY OF L I M E L I T E SHORT PLAT
FlELDBOOK:
6 CITY COMMENTS MB 9 os 16 PA RENTON 16204 114TH AVE SE, RENTON, WA 98055 ML PAGE:
5 CITY COMMENTS MB 8 15 16 PA °�W"' Me DRAWING NO:
4 CITY COMMENTS MB 7 07 16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE Planning/Building/Public Works Dept. CML DETAILS C13
IF NOT ONE INCH
NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY SHEET: OF:
R-398013