1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2016 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT.
2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY, A PRECONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF
FEDERAL WAY, THE APPLICANT, AND THE APPLICANT'S CONSTRUCTION REPRESENTATIVE.
3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
4. IT SHALL BE THE APPLICANTS/CONTRACTORS RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE
INITIATING OFF -SITE WORK WITHIN THE ROAD RIGHTS OF WAY.
5. VERTICAL DATUM: CITY OF RENTON, 1988 NAVD.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT,
FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT
PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE
TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AT LEAST ONE FLAGGER FOR EACH
LANE OF TRAFFIC AFFECTED. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07.23-TRAFFIC CONTROL, SHALL
APPLY.
7. ALL UTILITIES SHALL BE ADJUSTED TO FINAL GRADE.
CONSTRUCTION SEQUENCE
1. PRE -CONSTRUCTION MEETING.
2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF
CONSTRUCTION SIGN).
3. FLAG OR FENCE CLEARING/CONSTRUCTION LIMITS.
4. INSTALL CATCH BASIN PROTECTION IF REQUIRED.
5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S).
6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.).
7. GRADE AND STABILIZE CONSTRUCTION ROADS.
8. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING
FOR PROJECT DEVELOPMENT.
9. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND
MANUFACTURER'S RECOMMENDATIONS.
10. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION AND
SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS.
11. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET
SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT.
12. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS.
13. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS.
14. UPON
COMPLETION
OF THE PROJECT, ALL DISTURBED AREAS MUST BE
STABILIZED AND BMP5 REMOVED
IF APPROPRIATE.
CITY
OF
RENTON EROSION
CONTROL
NOTES
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH
THE CITY OF RENTON, PUBLIC WORKS DESIGN ENGINEER.
2. ALL LIMITS OF CLEARING AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BE
CLEARLY FLAGGED IN THE FIELD AND OBSERVED DURING CONSTRUCTION.
3. ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND
CLEARING AND/OR CONSTRUCTION TO ENSURE THAT SEDIMENT LADEN WATER DOES NOT ENTER THE NATURAL DRAINAGE
SYSTEM. ALL EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME
THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE
IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE
THE RESPONSIBILITY OF THE PERMITEE.
4. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM
REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL
CONDITIONS DICTATE, THE PERMITEE SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES
WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF
CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITEE TO ADDRESS ANY NEW CONDITIONS
THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM
REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING
DRAINAGE SYSTEM.
5. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF
STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR RETENTION FACILITIES.
6. DURING THE TIME PERIOD OF OCTOBER 1ST THROUGH APRIL 30TH, ALL PROJECT DISTRIBUTED SOIL AREAS GREATER
THAN 5,000 SQUARE FEET, THAT ARE TO BE LEFT UN -WORKED FOR MORE THAN 12 HOURS, SHALL BE COVERED BY
MULCH, SODDING OR PLASTIC COVERING.
7. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE NO FURTHER WORK IS ANTICIPATED FOR A
PERIOD 30 DAYS OR MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTING
OR OTHER APPROVED EROSION CONTROL TREATMENT APPLICABLE TO THE TIME OF YEAR. GRASS SEEDING ALONE WILL
BE ACCEPTABLE ONLY DURING THE MONTHS OF APRIL THROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED,
HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE PERMITEE, BUT MUST BE AUGMENTED WITH MULCHING, NETTING OR
OTHER TREATMENT APPROVED BY THE CITY OF RENTON, OUTSIDE THE SPECIFIED TIME PERIOD.
8. FOR ALL EROSION/SEDIMENTATION CONTROL PONDS WHERE THE DEAD STORAGE DEPTH EXCEEDS 6 INCHES, A FENCE IS
REQUIRED WITH A MINIMUM HEIGHT OF THREE (3) FEET, 3:1 SIDE SLOPES.
9. A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE, 24 FEET X 50 FEET X 8 INCHES OF 4 TO 6 INCH QUARRY SPALLS
SHALL BE LOCATED AT ALL POINTS OF VEHICULAR INGRESS AND EGRESS TO THE CONSTRUCTION SITE.
Know what's below.
Call before you dig.
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
PERMIT CONDITIONS OF APPROVAL
1. BUILDING ON LOT 5 SHALL BE CONSTRUCTED WITH A FIRE SPRINKLER SYSTEM.
2. APPLICANT SHALL SUBMIT STRUCTURAL CALCULATIONS FOR THE STORMWATER DETENTION TANK CONFIRMING THAT THE TANK CAN SUPPORT A 30 TON LOADING WITH 75-PSI POINT LOADING PRIOR TO CONSTRUCTION OF THE STORMWATER
DETENTION TANK OR FINAL RECORDING OF SHORT PLAT, WHICHEVER COMES FIRST
3. PRECONSTRUCTION MEETING REQUIRED PRIOR TO THE START OF WORK.
4. BOND OR CASH SURETY IS REQUIRED PRIOR TO THE START OF CONSTRUCTION.
LIMELITE SHORT PLAT - U15006542
RENTON, WASHINGTON
SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS
1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH
THE CITY OF RENTON PLAN REVIEWER.
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND
MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED
BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT.
3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON
FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL
FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION.
4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL
CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS.
6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND
THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE
EROSION HAS PASSED. AFTER CONSTRUCTION ACTIVITY IS COMPLETE THEY MUST BE REMOVED.
7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL
CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY
SECTION.
8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED
STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS
DEPARTMENT, SURFACE WATER UTILITY SECTION.
9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION
7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION.
THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS
WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE
LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE
APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95%
FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6
INCHES OVER AND UNDER PVC PIPE.
10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1
OR BETTER INSIDE AND OUTSIDE.
11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15
FEET FROM THE TOP OF ANY CHANNEL BANK.
12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL.
13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY
APPROVED BY CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS ADMINISTRATOR.
14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY
ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS:
4 - 8 INCH ROCK / 40 - 70% PASSING;
2 - 4 INCH ROCK / 30 - 40% PASSING; AND
LESS THAN 2 INCH ROCK / 10 - 20% PASSING.
15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS
APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED
AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION.
16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF
THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER,
THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE
SYSTEM PROVIDED DURING CONSTRUCTION.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE
EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC,
AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY
WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC
CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF
THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY.
18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA
(APA).
SURVEY INFORMATION
1. METHOD OF SURVEY: INSTRUMENTATION FOR THIS SURVEY WAS A TRIMBLE ELECTRONIC DISTANCE MEASURING UNIT.
PROCEDURES USED IN THIS SURVEY WERE DIRECT AND REVERSE ANGLES, NO CORRECTION NECESSARY. MEETS STATE
STANDARDS SET BY WAC 332-130-090.
2. VERTICAL DATUM: PER CITY OF RENTON SURVEY CONTROL PT #1863; CONIC MON ® INTX OF 116TH AVE SE & SE 168TH ST,
ELEV=459.08'
3. BASIS OF BEARINGS: PER CITY OF RENTON SURVEY CONTROL, THE EAST LINE OF NE QUARTER SEC 29-29T-R5E BEARS
N01'47'08"E.
4. EXISTING LEGAL DESCRIPTION: THE NORTH HALF OF LOT 6, BLOCK 4 OF AKER'S FARM NO. 6 AS PER PLAT RECORDED IN
VOLUME 42 OF PLATS, PAGE 15, RECORDS OF KING COUNTY, WASHINGTON.
5. SEE SURVEY FOR MORE INFORMATION.
SURVEYED: SCALE:
nI��w983/1991
1988
7 SHARED DRIVEWAYS MB 3 29 17 PA DESIGNED: 1 =10>' HORZONTNAD
6 CITY COMMENTS MB 9 09 16 PA MB
5 CITY COMMENTS MB -8/-15/1-6 PA DRAWN: MB
4 CITY COMMENTS MB 7 07 16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
co
<
77777777/7
SE 162ND STREET
co
PROJECT SITE
SE 164TH STREET
VICINITY MAP
SCALE 1 " = 200'
ABBREVIATIONS
BC: BOTTOM OF CURB
BW: BACK OF WALK
TC: TOP OF CURB
EX: EXISTING
DI: DUCTILE IRON
SD: STORM DRAIN
SS: SANITARY SEWER
W: WATER
CIVIL SHEET INDEX
C1
COVER AND NOTES
C2
PERVIOUS CONCRETE SPECIFICATIONS
C3
TESC PLAN
C4
PAVING AND GRADING PLAN
C5
DRAINAGE AND UTILITY PLAN
C6
FRONTAGE IMPROVEMENTS- SE 162ND ST
C7
ROADWAY SECTIONS- SE 162ND ST
C8-10
FRONTAGE IMPROVEMENTS- 114TH AVE SE
C11
ROADWAY SECTIONS-114TH AVE SE
C12-16
CIVIL DETAILS
SOOS CREEK WATER AND SEWER DISTRICT PLANS
1 SEWER PLAND AND PROFILES & NOTES
2 MATERIALS & SURFACE RESTORATION
3 CONSTRUCTION PROVISIONS
4 SEWER DETAILS
CONTACTS
OWNER
LIMELITE DEVELOPMENT
CIVIL ENGINEER
COTERRA ENGINEERING
321 3RD AVENUE , SUITE 406
SEATTLE, WA 98104
CONTACT: PETER APOSTOL, PE
TEL: (206) 596-7115
SURVEYOR
GEODIMENSIONS, INC
10801 MAIN ST, SUITE 102
BELLEVUE, WA 98004
CONTACT: EDWIN J GREEN
TEL: (425) 458-4488
PLANNER
TERRANE
FORMERLY (GEODIMENSIONS, INC)
10801 MAIN ST, SUITE 102
BELLEVUE, WA 98004
CONTACT: ANDY MCANDREWS
TEL: (425) 458-4488
LANDSCAPE
ROOT OF DESIGN
7104 256TH ST NW #218
STANWOOD, WA 98292
CONTACT: DEVIN PETERSON
TEL: (206) 491-9545
ELECTRICAL
TRAFFEX
11410 NE 124TH ST., #590
KIRKLAND, WA 98034
CONTACT: LARRY HOBBS, PE
TEL: (425) 522-4118
UTILITY PURVEYOR
SOOS CREEK WATER AND SEWER DISTRICT
14616 SE 192ND ST
RENTON, WA 98058
TEL: (253) 630-9900
SAFE WALK TO SCHOOL PLAN
LITCHEFIELD ENGINEERING
12840 81ST AVENUE NE
KIRKLAND, WA 98034
CONTACT: KEITH A. LITCHFIELD
TEL: 425-821-5038
ILLUMINATION PLANS
IL1 ILLUMINATION PLAN
IL2-3 ILLUMINATION DETAILS
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
LANDSCAPE PLANS
L1 LANDSCAPE PLAN
LIRRIENT PLANNING
DEVELOPMENT ENGINEERING �
L2 LANDSCAPE PLAN
davis 06/20/2017
Brianne Bannwarth 06/22/2017
1 SAFE WALK TO SCHOOL PLAN
SURFACE WATER UTILITY
UTILITY SERVICE NOTES
rstraka 06/20/2017
0
COORDINATE BLDG. SYSTEM CONNECTION SIZES, LOCATIONS AND INVERT ELEVATIONS WITH PLUMBING CONTRACTOR. VERIFY THAT THERE ARE NO
CONFLICTS WITH PROPOSED SYSTEMS AND OTHER UTILITIES.
2. COORDINATE INSTALLATION OF NEW WATER AND SEWER SERVICES WITH CITY OF RENTON AND SOOS CREEK WATER DISTRIC.
3. DESIGN BUILD FIRE SPRINKLER CONTRACTOR SHALL VERIFY SIZE OF FIRE METER, LINE SIZE, AND FDC LINE SIZES PRIOR TO CONSTRUCTION.
CONSTRUCTION PERMIT SUBMITTAL
-]
DATE: 5/3
Z
CITY OF LIMELITE SHORT PLAT FlELDB5/31/17
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DRAWING NO:
Planning/Building/Public Works Dept. COVER AND NOTES ci
SHEET: OF:
R-398001
2
FINISH
GRADE
z
M
N
TREE STAKE
PREVAILING ROOTBALL
WIND TRUNK
TREE STAKE
PLASTIC TREE TIES
WOOD STAKE, STAKES SHOULD
ROOT FLARE SHALL BE LOCATED
ABOVE GROUND LINE
3" MULCH LAYER, KEEP AWAY
z
EH 3" WATER BASIN
SCARIFY SIDE & BOTTOM OF
PLANTING PIT TO ALLOW FOR
ROOT PENETRATION
I I
I 1=1 I
s�opFl Irr. I'�• �oQ I CONCRETE SIDEWALK
3x MINIMUM ROOTBALL DIAMETER
RECOMPACT SUBGRADE
NOTES:
n TREE PIT SHALL NOT BE LESS [-4.] TREE STAKES PERPENDICULAR
THAN 3 TIMES ROOT BALL DIA.1 ITO THE PREVAILING WIND
2❑ CUT ALL TIES AND FOLD RACK RLAP 5❑ PLANT TREES 2" HIGHER THAN
FROM UPPER 1 3 OF ROOT BALL DEPTH GROWN IN NURSERY
3❑ REMOVE ALL PLASTIC AND TWINE
TYPICAL DECIDUOUS TREE PLANTING DETAIL
NTS
REMOVE BURAP
TWINE OFF TOP 1 3
3-4" MULCH
FINISH GRADE
ROOT PENETRATIONI
RECOMPACT SUBGRADE
ENSURE THAT ROOT
FLARE WILL NOT SETTLE
BELOW GROUND LINE
TYPICAL SHRUB PLANTING DETAIL
NTS
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Print Form Reset Form Save Form
CITY OF
-----Renton
TREE RETENTION WORKSHEET
Planning Division
1055 South Grady Way -Renton, WA 98057
Phone:425-430-7200 1 www.rentonwa.gov
1.
Total number of trees over 6" diameter', or alder or cottonwood
trees at least 8" in diameter on project site
11
trees
2.
Deductions: Certain trees are excluded from the retention calculation:
Trees that are dangerouS2
trees
Trees in proposed public streets
trees
Trees in proposed private access easements/tracts
trees
Trees in critical areas' and buffers
trees
Total number of excluded trees:
o
trees
3.
Subtract line 2 from line 1:
11
trees
4.
Next, to determine the number of trees that must be retained 4, multiply
line 3 by:
0.3 in zones RC, R-1, R-4, R-6 or R-8
0.2 in all other residential zones
0.1 in all commercial and industrial zones
3
trees
5.
List the number of 6" in diameter, or alder or cottonwood trees
over 8" in diameter that you are proposing5 to retain 4:
8
trees
6.
Subtract line S from line 4 for trees to be replaced:
(if line 6 is zero or less, stop here. No replacement trees are required)
(5)
trees
7.
Multiply line 6 by 12" for number of required replacement inches:
(56)
inches
8.
Proposed size of trees to meet additional planting requirement:
(Minimum 2" caliper trees required for replacement, otherwise enter 0)
0
inches per tree
9.
Divide line 7 by line 8 for number of replacement trees6:
(If remainder is .5 or greater, round up to the next whole number)
o
trees
Measured at 4.5' above grade.
Z A tree certified, in a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed
landscape architect, or certified arborist, and approved by the City.
3 Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050.
"Count only those trees to be retained outside of critical areas and buffers.
s The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-1301-17a.
6 When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2") caliper or an evergreen at least
six feet (6') tall, shall be planted. See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees.
1
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\Tree Retention Worksheet.docx 08/201E
CANOPY DRIP LINE
NO TRESPASSING
'ROTECTED TREE'
iIGN POSTED EVERY 50
"EET (MINIMUM OF 2).
VEGETATION AND TREE
FENCING SHALL BE A
MINIMUM OF 6' HIGH
TEMPORARY CHAIN LINK
FENCING WITH 10' LACING
BETWEEN POSTS.
PROTECTION MEASURES DURING CONSTRUCTION:
1. CONSTRUCTION STORAGE PROHIBITED: DO NOT FILL, EXCAVATE, STACK OR
STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS,
OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE
EARTH IN ANY WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO
\ BE RETAINED.
J 2. FENCED PROTECTION AREA REQUIRED:PRIOR TO DEVELOPMENT ACTIVITIES, A 6'
HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES
OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO
ONE AND ONE -QUARTER FEET FOR EVERY ONE INCH OF TRUNK CALIPER,
WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION
j TRACT. PLACECARDS SHALL BE PLACED ON FENCING IF LESS THAN 50' INDICATING
THE WORDS, 'NO TRESPASSING -PROTECTED TREES' OR ON EACH SIDE OF THE
FENCING IS LESS THAN 50'. SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR
GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE
FENCED ON 4 SIDES.
3. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE
TO BE RETAINED IS TO BE RAISED, A DRY ROCK WALL OR ROCK WELL SHALL BE
CONSTRUCTED AROUND THE TREE. THE DIAMETER FO THIS WALL OR WELL MUST
BE EQUAL TO THE TREE'S DRIP LINE.
4. MULCH LAYER REQUIRED; ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE
COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF 3" OF BARK MULCH
PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING.
PROTECTED ROOT ZONE WITHIN THE CANOPY DRIP LINE -
ACTUAL FEEDER ROOTS EXTEND WELL BEYOND DRIP LINE
RENTON TREE PRESERVATION DETAIL
NTS
n
INSTALL GROUNDCOVERS
DEPTH
PLAN VIEW OF SPACING
NC�I�I]:]�.Y.yh[e»ii111�Ii:�
JMULCH. VERIFY SAUCERI
L
TYPICAL GROUNDCOVER PLANTING DETAIL
NTS
Tr" #
Species
(federal code)
Size
inches
Current health rating
(good, fair, had)
Drip line
radius
- North
Duip
line
Son t1h
Drip
line
East
Drip
fine
Wes,
1
AEHI
2 3.5
good
17
20
20
1S
AEHI
19-51
arood
1.1
13
15
18
3
P ME
26-5
good
18
25
15
1S
4
PE
'0
Lyood
18
Is
15
15
5
P ME
22-8
good
18
15
15
6
PE
29
flood
18
24.6
15
15
7
P I E
24.5
good
18
25
15
15
8
PS M E
1.8
good
18
15
15
15
9
P ME
21-8
i2ood
t S
=0
15
15
10
P ME
30-5
good
18
'S
15
15
11
PhE
I4-9
goad
1s
= 1
35
15
trees on sites
Douglas fir, Pseudc suga menzi+esii. P ME
horse chestnut. Aesculus hippocastanum, AEHI
NOTES:
MULCH TREE PIT MIN 5-0" LENGTH X
FULL PLANTING STRIP WIDTH BETWEEN
CURB AND SIDEWALK (FOR PLANTING
STRIPS LESS THAN 6'-0" WIDE) OR
PROVIDE 5-0"DIA MULCH RING FOR
PLANTING STRIPS WIDER THAN 6'-0".
STAKE TREE WITH (2) TREATED
2" LODGEPOLE PINE DOWLED
TREE STAKES (8'-0" LENGTH)
LOOP EACH TIE AROUND HALF
TREE LOOSELY TO PROVIDE 1"
SLACK FOR TRUNK GROWTH.
"CHAINLOCK" OR EQUAL TREE TIE
MATERIAL (1" SIZED) NAIL OR
STAPLE TREE TIE MATERIAL TO
STAKE TO HOLD VERTICALLY.
LOOP EACH TIE AROUND HALF -
TREE LOOSELY TO PROVIDE 1"
SLACK FOR TRUNK GROWTH.
2"-3" MULCH DEPTH
(TAPERED AT TRUNK)
SIDEWALK
18" ROOT BARRIER
AT SIDEWALK
ROUGHEN SIDES OF PLANTING
HOLE TO MAXIMIZE EXCAVATED
AREA WITHOUT UNDERMINING
ADJACENT PAVING/CURB
ROOT BARRIER; PLACE AT EDGE
OF PAVEMENT/SIDEWALK/ETC.;
PLACE PRIOR TO PLACEMENT OF
NEW SIDEWALK OR CURB TO
PREVENT UNDERMINING.
TOP SOIL TYPE B, OR AS '
APPROVED BY ENGINEER.
REMOVE ALL WIRE, STRINGS,
AND OTHER NON -BURLAP
MATERIAL; AND REMOVE
BURLAP FROM TOP 2/3 OF
ROOTBALL.
CL
�I
2'-0" MIN2"
S-6" MIN
MIN WIDTH OF TREE PIT = 2 TIMES ROOTBALL DIAMETER _
OR 5-0", WHICHEVER IS GREATER
MULCH AREA TO BE CLEAR OF GRASS, WEEDS, ETC. TO
REDUCE COMPETITION WITH TREE ROOTS
NOTES:
1. PLANTING INCLUDES REMOVAL OF
STAKES ONE YEAR AFTER INSTALLATION.
2. SHAPE SOIL SURFACE TO PROVIDE 3"
DIAM WATERING RING.
3. TREE CLEARANCE SHALL BE PER STD
PLAN NO 030.
4. SEE STD PLAN NO 424 FOR TREE PIT
DETAIL.
5. ADJUST TREE TIES DURING
ESTABLISHMENT TO ALLOW ROOM FOR
GROWTH (@ 1" SLACK).
6. ROOT BARRIER REQUIRED ALONG EDGE
OF ROADWAY, CURB, DRIVEWAY, TRAIL,
SIDEWALK, OR OTHER STRUCTURES
WHERE ROOTBALL IS WITHIN TWO FEET;
PLACE VERTICAL ROOT BARRIER AS
SHOWN IN STANDARD PLANS 424A OR
424B UNLESS OTHERWISE INDICATED IN
THE CONTRACT OR DIRECTED BY THE
ENGINEER.
SET TOP OF ROOT CROWN
2" ABOVE ADJACENT CURB
& SIDEWALK GRADE.
3" TO 4" HIGH
WATERING RING
(SEE NOTE 2)
24" ROOT BARRIER
AT CURB.
DECIDUOUS TREE PLANTING IN PLANTING STRIP
NTS
TREE PIT DEPTH =
ROOTBALL DEPTH
(MEASURE BEFORE
DIGGING TO AVOID
OVEREXCAVATION).
DRIVE STAKES 6" TO
1'-0" INTO UNDISTURBED
SOIL BELOW ROOTBALL.
DRIVE STAKE AT ROOTBALL
EDGE (TYP) (SEE NOTE 1)
UNDISTURBED SUBGRADE
(PROVIDES FIRM BASE SO THAT
ROOTBALL WILL NOT SINK.
STANDARD PLAN NO 100a, CITY OF SEATTLE
1. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL OTHER SITE I MPROYEMENTS AND CONDITIONS PRI O
TO 5TARTING LANDSCAPE WORK.
2. CONTRACTOR SHALL USE CAUTION WHILE EXGAVAT I N6 TO AVOID DISTURBING ANY UTILITIES ENCOUNTERED. CONTRACTOR 15 TO
PROMPTLY ADV 1 SE OWNER OF ANY DISTURBED UTILITIES. LOCATION 5ERV I GE PHONE I -aOO-424-5555.
5. CONTRACTOR SHALL MAINTAIN AND WATER ALL PLANT MATERIAL FOR I YEAR OR UNTIL FINAL INSPECTION AND ACCEPTANCE BY
OWNER.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING allANT I T I ES OF PLANTS THAT ARE REPRESENTED BY 5YMBOL5 ON THE
DRAW I N&.
5. 5UBGRADE 15 TO BE WITHIN 10
-L INCH OF I FOOT AS PRO\/I DED BY OTHERS. ALL PLANTING AREAS TO BE CLEARED OF ALL
CONSTRUCTION MATERIAL AND ROCKS $ STICKS LARGER THAN 2 INCH DIAMETER.
6. 4 INCH DEPTH TOPSOIL IN LANDSCAPE AREA.
7. 2 INCH DEPTH, 2 FOOT DIAMETER BARK RING AROUND BASE OF STREET TREES AND OTHER TREES LOCATED IN LAWN.
5. GROUND COVERS SHALL BE PLANTED IN AN EGU I LATERAL TR I ANGULAR SPACING PATTERN AT THE ON -CENTER DISTANCES SHOWN ON
THE PLAN OR IN THE PLANT SCHEDULE. WHERE GROUND COVER ABUTS CURBING, 511DEWAL<S, SIGNS OR POLES, MINIMUM PLANTING
DISTANCES SHALL BE 12" FROM CENTER OF PLANT TO CURB, S 1 DEWALK, ETC. MINIMUM PLANT I N6 DISTANCE SHALL BE 24" FROM CENTER
OF TREES AND SHRUBS.
q. ALL PLANT MATERIAL SHALL BE FERTILIZED WITH AGRO TRANSPLANT FERTILIZER 4-2-2 PER MANUFACTURERS SPECIFICATIONS.
10. ALL PLANT MATERIAL SHALL CONFORM TO AAN STANDARDS FOR NURSERY STOCK LATEST EDITION. ALL PLANT MATERIAL FURNISHED
SHALL BE HEALTHY REPRESENTATI \/ES, TYPICAL OF THEIR SPECIES OF VARIETY AND SHALL HAVE A NORMAL GROWTH HABIT. THEY SHALL
BE FULL, WELL BRANGHEID, WELL PROPORTIONED, AND HAVE A VIGOROUS WELL DEVELOPED ROOT SYSTEM. ALL PLANTS SHALL BE HARDY
UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN THE LOCALITY OF THE PROJECT. TREES, SHRUBS AND GROUNDCOVER aUANT I TI ES,
SPECIES, VARIETIES, SIZES AND CONDITIONS TO BE AS SHOWN ON THE PLANTING PLAN. PLANTS TO BE FREE OF DISEASE, INJURY, INSECTS,
DEGAY, HARMFUL DEFECTS AND ALL WEEDS. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM LANDSCAPE
ARCHITECT O OWNER.
11. NO PERMANENT IRRIGATION 5YSTEM 15 PROPOSED. TEMPORARY IRRIGATION SHALL BE REOU I RED FOR THE FIRST 5 YEARS OR UNTIL
PROPOSED PLANT MATERIAL 15 ESTABL I SHED. PLANT MATERIAL SPECIFIED TO BE NATIVE OR DROUGHT TOLERANT AS DETERMINED BY
LANDSCAPE ARCHITECT.
12. THE AVERAGE SPAG I N6 FOR STREET TREES SHOULD BE 40 FEET ON CENTER AND ADJUSTED TO ALLOW FOR SIGHT LINES, UTILITIES,
TRAFFIC 51 GNS, LIGHT STANDARDS, DRIVEWAYS AND OTHER STREET APPURTENANCES.
15. TREES IN THE RIGHT OF WAY MUST BE PLANTED TO THE FOLLOWING STANDARDS: PLANT TREES IN THE CENTER OF THE PLANTING STRIP
WIDTH. 6 FEET FROM FIRE HYDRANTS AND UNDERGROUND UTILITIES 00> WATER, SEWER, ELECTRIC, GAS). 10 FEET FROM UTILITY POLES,
DRIVEWAYS, AND ALLEY MARGIN, 25 FEET FROM STREET LIGHTS, 40 FEET FROM THE CORNER OF INTERSECTIONS, STOP 5I GNS, AND YIELD
SI GNS. AT LEAST 72 HOURS BEFORE YOU PLAN TO DIG, YOU MUST GALL 811 TO REQUEST THAT THE LAST LOCATION OF ANY UNDERGROUND
OR OVERHEAD UTILITIES (GAS, WATER, ELEGTRI G, ETC.) BE MARKED ON YOUR PLANTING AREA. <NOWI NG THESE LOCATIONS IN ADVANCE
MAY SAVE YOU TIME AND MONEY BY PREVENTING AN ACCIDENT.
d)
# U-
p
�
•� 4z
C:
Z 1-
M
��
0)1It
�
ri
U- A) -6
O
4-1
�
10
O
Nr0)
PROJECT TITLE
State of
Washington
registered
Landscape Architect
Pevin Peterson
certificate no. 1222
Z
a a
J �
a Z
O
W W
a
LU
Q N
N a
H
Z
a 0
N
J
N
NG I.II.117
NG E D 03.16. J 1
REVISED DATE
REVISED DATE
L2
R-398018
TREE DENSITY TABLE
LOT
LOT 51 ZE
MIN. SIGNIFICANT
TREES REQUIRED
NEW TREE51
IRETAINED TREES
[COMPLIANT
0
5,055 SF
2❑
2 ® 2" GAL I PER
O❑
YES
2❑
5,055 SF
2❑
1 (P 2" CALIFER1
YES
11 TREE @ 50.5" GAL.
0
5,Q42 592❑
1
-7 TREEG L IS"-2�i"
YES
4
8,852 SF
®
4 9 2" GAL I PER
0
YES
5
2
lf=LANT SC.,HEDULEI
DV I i-tIVlVi-tL IVi-tl"IC / VVI"II"IVIV IVf-tl"IC
Corpus kousa 'Chinensis' / Kousa Dogw
Street Tree
Lot Landscaping Tree / TSD
All trees planted must include a 2" dep
mulch ring with a 2 ft radius around the
tree.
GROUND COVERS 507ANICAL NAME / COMMON NAME
,Arborist Chips
Landscape Area
All ground covers must be a min. 4" pot,
planted in triangular spacing.
All shrubs must be a min. 2 gallon
container size, planted with a min. 2"
mulch depth.
Turf Sod / Drought Tolerant Fescue 51
0TY
1,121 sf
2,7Q5 sf
10,547 sf
NOTE:
-DETAIL LANDSGAFE FLAN TO E3E SUEM 1 TTED
WITH E3UILDING FER�-1I7 Ai=i='LIGATION.
-ALL fi ER\/IOUS AREAS TO E3E LANDSGAi=ED.
-STREET FRONTACGE LANDSGAfi=E TO INCLUDE
A 1M I XTURE OF TREES, SHRUE35, AND
GROUNDGOVER.
-DRIVEWAY LAYOUTS ARE Ai=fi='ROX 11MATE
AND WILL 5E Uf= DATED AT E3U I LD I NG f= ERM 1 T.
LANDSC.,AFE CLAN
SCALE : III
— 10,
— II
DETAGHED SINGLE FAMILY DEVELOPMENT:
7WO SIGNIFICANT TREES ARE REQUIRED FOR EVERY 5,000 5F.
LOT AREA EX: 2 - MINIMUM NUMBER OF TREES
1!51000
#
Q
Z
4-1
O
7
Q
4-1
0
Q
cV r ct1
�
VOL
PROJECT TITLE
State of
Washimton
registered
landscape Architect
nevin Peterson
certificate no. 1222
z
a a
J �
a Z
0
W W
a
W
a N
LU
U >
N a
o
z
a
N
J
QATF
mN 1.11.1"1
NC-7Eo 05.16.1� i
REVISED DATE
REVISED DATE
Ll
R-398022
z
M
o
-
r
0
0
_j
-0
rf)
cl:
0
re)
Ci
fn
cV
co
Uj
V)
V)
_j
0)
__j
0
V)
Ld
II-_
Uj
(D
rr
O
0
E-4
C)
n
001,
M
1-,
n
Z R
OF
WN
wo
>-.
W
Z ZO
Z
Z
3�
D
0
UZI
S2
Y)
w
0
C3
y
0
0
a-
0-
<
a_
a_
<
REFER TO WSDOI LOCKING LID STANDARD
DUTY JUNCTION BOX TYPES I & 2
,NtANDARD PLAN J-40.10-03
SPLICE KITS CLEAR EPDXY
S W, E Kip ON ALL THRU
SPLICE
4' CONCRETE PAD
l gget,5p
IM
2' MIN, #J5 BARE COPPER
GROUND "RE
:I rll
1 -#a EQUIPMEN 'U 'j WIREW/MCN INSULATION
FROM SERVICE CABINET
2 - LIGHTING SYSrEV-
WIRES TO CONTACTOR
(SIZED AS REOV.)
5/W'x8' COPPER CLAD
GROUND ROD
LUMINAIRE WIRES WILL BE A CONTINUOUS RUN
FROM FUSE HOLDER TO FIXTURE WITH
NO SPLICES.
GROUND ROD
FUSE KITS QUICK DISCONNECT
TO LUMINAIRE
3 AMP W USE FUSE KITS
LUMINAIRE WIRES WILLBE.#42
S.E.C. OR EQUAL
AW IN A JACKETED CABUEi
#0 GREEN INSULATED WIRE
�1
TO FIXTURE GROUND LUG
GROUND LUG
WM
IMUM
tXR0�10
HOtE
2' MIN. GROUT
TOP Of CONCRETE 1`000AnoN To
_
Sr_
UNDER POLE BASE—,
BCE LEOAM! VV_ WTH TOP OF SIDEWALK
I
i
PL
GROUND
CLAMP
II------------
2"YPVCSTEM CONDUIT I II II
S
CONCRETE ---------------- J_L
FOUNDATION
5' SO. OR DIA.
U—OTES.
1. EQUIPMENT GROUND WIRE do BARE "RE SHALL BE
SECURELY FASTENED TO 1HE: GROUND LUG INSIDE THE
POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS
SHALL REMAIN ACCESSIBLE FOR INSPECTION AND
MAINTENANCE.
2. IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR
THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED
WRE OF FHE SAME SIZE SHALL BE RUN FROM THE FIXTURE
TO THE GROUND LUG INSIDE THE. POLE HANDHOLE. IF THE
FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN
INSULATED %RE SHALL BE RUN FROM THE FIXTURE
GROUND LUG TO THE POLE GROUND LUG.
in. FILM - Ito
PUBLIC WORKS TYPICAL LIGHT11ING
DEPARTMENT UNDERGROUND SYSTEM
A :
I APPRO�,.ED:.
......................... .......................
..........
-------
....... ------
....... ....
0 0
C)
3'
STREET LIGHT POLE\
�JUNCTION BOX
PLAN VIEW
4" DEEP
SIDE VIEW
LIGHTING STANDARD & JUNCTION BOX
PLAN VIEW
INDIVIDUAL JUNCTION BOX
NOTE:
CLASS V CONCRETE TO BE
USED IN CONSTRUCTION OF PAD
PUBLIC WORKS CONCRETE PAD DETAILS SM. PLAN - 120
DEPARTMENT
WYE SPLICE
SPLICE KIT
FUSE KIT
FUSE KIT & SPLICE KIT DETAILS
y
0 7 *,ON-s
ADOPTED
CITY OF RENTON
+ +
MR
1R, Standard plans
6) LST DATE: 11/5/96
DATE I REVISION IBY DWG. NAME: JR-12 SP PAGE:JO13
:4-j-
A
---------------
1 1 1 �_,
_Lj I
U a: is I
ow
u z
< gi:i
0-1
Of
z
C-4 L0
R < Z
5 0 Q of. 2
Z11 5 g DOW_ H is
M 0
& ME
011 . :5 Ls
ro
0
Of_ z
>
JX!: UiI -2- -
0
>
0 z
C a
50
---- C ct LUtR
1
wo?l - L- �3 ;z. .1
0 i
ot _w 2
w
Z<
S
*E
a , 4wi� j of
m<
N r z
Le;
E
z
C)
-------------
L
z
.4
01
PUBLIC WORD SERVICE CABINET SM. PLAN 122.1
DEPARTUM WITHOUT IIIIIIIIIIIIIS
STREET LIGHTING CONTACTOR CABINET
WIRING SCHEMATIC
TYPE III SERVICE 120Z240 VOLT
100 A MAIN BREAKER (MIN.)
2 POLE 240 VOLT II
BRANCH BREAKERS
120/240 VOLT
TEST
16 POLE
SWTCH
TERMINAL
BLOCK —
CIRCUIT WIRES TO LIGHTING RUNS
PHOTO -CELL
MOUNTED ON
NEAREST
LUMINAIRE
<
fh
F
z
1
UTILITY
PLUG (GFI)
STREET LIGHTING
CONTACTORS
TO GROUND
ROD
WIRING COLOR CODE
A. WHITE JACKET (NEUTRAL)
B. BLACK JACKET (LINE)
C. GREEN JACKET (GROUND)
D. RED JACKET (LOAD)
E. GREEN OR BARE WIRE (GROUND)
. 3
PUBLIC WORKS STREET LIGHTING CONTACTOR. PROVESMFLAN — 12
,
DEPARTMENT CABINET SCHEMATIC 4111111-
Taff
NORTHWEST �X
TRA F-F-1c EXERTS
11410 NE 124th St., #590, Kirkland, WA 98034
Phone: 425.522.4118 Fax: 425.522.4311
w
4-17-17
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION
ATION OPERATION 1
06/22/2017
Cbarn:s +
CONDUIT ENTR. AREA
k
PLAN VIE
SIZE To FIT SIZE TO FIT
CABINET CABINET
0'
*r4
�_611 --Grade Level
jr
L-
4 F
FRONT VIEW
STREET LIGHT CONTACTOR FOUNDATION
Shim to plumb Shim to plumb
La -IV —See Note 3See Note 3
#4 hoops
+1 1 #4 hoops
#4 bar each corner
10 1 r-Y4 bar each canner
If
45, MIN to 2"
3/8" diameter piastic or -In Q\_3/a" diameter plastic drain
SIR
f-a" cabinet depth
Cabinet depth 1.
+ 2-
#4 bar each corner �
#4 bar each
corner
PLAN VI W PLAN ME
PAD MOUNT PADMOUNTCONTROLLER CABINET FOUNDATION BAIERY 162= (11115) FOUNDATION
For NOTES see Std. Plan 126.2
PUBLIC WORKS CABINET FOUNDATION DETAILS ROVESTD. PLAN 126.1
DEPARTMENT o 1111,2-
1-Ii!
K-JUbU I I
TREE DENSITY TABLE
LOT
LOT 51 ZE
MIN. SIGNIFICANT
TREES REQUIRED
NEW TREE51
IRETAINED TREES
[COMPLIANT
0
5,055 SF
2❑
2 ® 2" GAL I PER
O❑
YES
2❑
5,055 SF
2❑
1 (P 2" CALIFER1
YES
11 TREE @ 50.5" GAL.
0
5,Q42 592❑
1
-7 TREEG L IS"-2�i"
YES
4
8,852 SF
®
4 9 2" GAL I PER
0
YES
5
2
lf=LANT SC.,HEDULEI
DV I i-tIVlVi-tL IVi-tl"IC / VVI"II"IVIV IVf-tl"IC
Corpus kousa 'Chinensis' / Kousa Dogw
Street Tree
Lot Landscaping Tree / TSD
All trees planted must include a 2" dep
mulch ring with a 2 ft radius around the
tree.
GROUND COVERS 507ANICAL NAME / COMMON NAME
,Arborist Chips
Landscape Area
All ground covers must be a min. 4" pot,
planted in triangular spacing.
All shrubs must be a min. 2 gallon
container size, planted with a min. 2"
mulch depth.
Turf Sod / Drought Tolerant Fescue 51
0TY
1,121 sf
2,7Q5 sf
10,547 sf
NOTE:
-DETAIL LANDSGAFE FLAN TO E3E SUEM 1 TTED
WITH E3UILDING FER�-1I7 Ai=i='LIGATION.
-ALL fi ER\/IOUS AREAS TO E3E LANDSGAi=ED.
-STREET FRONTACGE LANDSGAfi=E TO INCLUDE
A 1M I XTURE OF TREES, SHRUE35, AND
GROUNDGOVER.
-DRIVEWAY LAYOUTS ARE Ai=fi='ROX 11MATE
AND WILL 5E Uf= DATED AT E3U I LD I NG f= ERM 1 T.
LANDSC.,AFE CLAN
SCALE : III
— 10,
— II
DETAGHED SINGLE FAMILY DEVELOPMENT:
7WO SIGNIFICANT TREES ARE REQUIRED FOR EVERY 5,000 5F.
LOT AREA EX: 2 - MINIMUM NUMBER OF TREES
1!51000
#
Q
Z
4-1
O
7
Q
4-1
0
Q
cV r ct1
�
VOL
PROJECT TITLE
State of
Washimton
registered
landscape Architect
nevin Peterson
certificate no. 1222
z
a a
J �
a Z
0
W W
a
W
a N
LU
U >
N a
o
z
a
N
J
QATF
mN 1.11.1"1
NC-7Eo 05.16.1� i
REVISED DATE
REVISED DATE
Ll
R-398022
ca ,�
D-R A XA1 I KI
R D
,z
— ., Hw-
- CONTRACTOR SHALL COMPLY WITH THE CITY OF o L
NAVD-88 w
- . RENTON'S TRENCH RESTORATION AND STREET w �, w
OVERLAY REQUIREMENTS. ~
W '�' `
L�] = c
- - -- - - o�
L moo CD
o
SE 162ND ST STA 1 Q+D = 1 +'AVE-SE STA--20*0 - .. - - - . - -- - _ - -- - — - — - F w - - -- S=� I_ � o 1- - -
- - d. — -- — _ - - • In - - - - — - - -
CONC MONUMENT 4Vf BRASS DISC - _ - _,� �:.
N 1700$4.65 q _ ca a "'
+"
E 1315d87.02 012 SE � 2N ST SEE S00S CREEK SEWER MAIN - -� LJ o I + w rs
~^ SS$' 29' 3$_90"E 1 d+SQ PLANS FOR SANffARY SEWELt
1+00 'MPRQVEMENTS �fiYF) - I
R2'M E 8 W&E-�47,�7,54 --- - -- ---- - --. - - 11+so I i �' ' 12+00
CB #9
12+50
)01
483.43t (j
- — RIM=483 43 -
EL CHK , — --
297 . A { 30 31, 13,00' RT
482-90f(E) END C 'AND GUTTER
---- - __ GRAE2:1 MAX&
MATCFr 'EX DITCH
S�q-GRADES
493.7 4'X5'X12," THICK RIP RAP
ACP RAMP, SLOPE AT 12:1
STA 1Q+37.99; 3R. — — fv�AX, M4TCH EX GRADE
w _ RAiif RECORDQRAWING �C 4' WIDE LANDING-
WAS
co
.. �wog �I� _
zG INFORMATION -ADD D BY TERRANE, INC.
7STA 10+12.99, 37.99' RTlv� -
P f t� 5 SENTS THE RESU TSO
F�A—SURVEY CONDUCTED I JULY, 201
AAL L A-S"
1 W
LLI
495
475
470
455
CD
6
CD
+
EX TOP OF CURB ELEVATION Ii
rn o n o �u'� a
PROPOSED TOP OF CURB ELEVATION
0
cc
+
u
SLOPE AT 2.0% MAX
STA 1;1+30,3:1, -24,,00',.RT
END #)EWALIt
8
i 1
N W T � U] W
I 1 07%
+ m�
� cn � cn u� c� � w
1-79%
SEE SHEET C8 FOR 5D PROFILE SEE SHEET SS1 FOR SODS
CREEL( SEWER EXTENSION PLANS
���
co
CD CD
mom
10+50
174 LF 12" SD 1,5%
EX GRADE AT ROADWAY CENTERLINE
�ECL�
�
re) �
��L
�cn�
�
�
O
00
¢
�
�
�
U
C3� -
UU�
(..i
L7�
UU�
m
—m
mI—
m
mom
mI—
m
11+00
11+50
SE
162ND ST
PROFILE
SCALE;
HORZ. 1" = 10' VERT. 1" =
5'
CURB RETURN TABLE
NO.
❑
R
STA PC LOCATION
TOP OF CURB ELEVATION
STA PT LOCATION
PC
1 4
1 2
3 4
PT
89'58'41.7"
25'
10+12.99, 37.99' RT
479.55
480.14
480.09
480,57
480.74
10+37,99, 13,00' RT
Know what's befog.
Call before you dig.
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 99104
ph 206.596.7115
cote rra en g i neeri n g. c o m
`u �-' 15 TF� 9 '
�C-,,lo
Q000ao
NOTES
1.
SEE SHEET C2
& C12 FOR GENERAL NOTES AND ROADWAY DETAILS.
2.
TYPICAL TRENCH
SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C 13.
3.
SEE SHEET C7
FOR ROADWAY SECTIONS.
4.
ALL LOCATIONS
OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE PLANS HAVE BEEN
DERIVED FROM
FIELD SURVEY PREPARED BY OTHERS AND SHOULD THEREFORE
BE CONSIDERED
APPROXIMATE ONLY AND NOT COMPLETE. ADDITIONAL SURFACE FEATURES AND
IMPROVEMENTS
BEYOND THOSE
INDICATED ARE PRESENT AND IT 15 THE SOLE RESPONSIBILITY
OF THE
CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL EXISTING INFORMATION
AND TO
FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES AND SURFACE FEATURES
NOT SHOWN
HEREIN WHICH
MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE PLANS.
SURVEYED;
7
SHARED DRIVEWAYS
MB
3 29 11
PA
DESIGNED:
me6
CITY COMMENTS
149
9 09 15
PA
5
CITY COMMENTS
M9
8 1 f 15
PAA:
MB
4
CITY COMMENTS
MB
7 Ol 16
PA
CHECKED:
PA
NC .
REVISION
H:Y
DATE
APPR
I APPROVED:
F
�0coro
mU�c� m
om
12+00
L.J
EL'
a
LEI
T
"`'
W
+
¢
�
of
LLJ
m � u'
1 71 LF 12" SD
GO oO LO
QLn
IE 480.65
5_ CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND ASSUMED CONFIGURATION.
THE CONTRACTOR SHALL UNCOVER ALL PIPING WHERE CROSSING, INTERFERENCES, OR
CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO
DETERMINE ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE THE
APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL ADJUST WATER LINE
ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED CLEARANCES.
6 COORDINATE ALL WORK WITH CITY OF REN70N TO ENSURE FACILITY ACCESS IS MAINTAINED AS
LEGEND
MER 1
CB TYPE-1 1
CB TYPE-2 48"
C14
- - - - - - - STORM DRAIN MAIN
SANITARY SEWER MAIN
SANITARY SERVICE LINE
— — — WATER SERVICE LANE
WATER/FIRE MAIN
CURB & GUTTER 4
C1
ASPHALT CONC
PAVEMENT 1
495
CEM. CONIC.
PAVEMENT1
490
PERVIOUS 3
CONCRETE1
SIDEWALK
485
SAWCUT LINE
175 - PRCP_ F.G. CONTOUR
480
►1 WATER VALVE
PIPE OUTLET
475
465
12+50
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY
rstraka 06120/201
DEVELOPMENT ENGINEERING
Brianne Bannwarih M2212017
CURRENT PLANNING
mdavis 06/20/2017 0
REQUIRED-
7, PROTECT UTILITIES TO REMAIN,
S. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO CURRENT CITY OF
RENTON STANDARDS_ IONS I flU +`-nON PERM T SUBMITTAL
SCALE: DATE
VERIKAL: KRVD 1988 2 /+]11 1
10=10, NORI;QHi+y Nap ,91��,4g, CITY O F LI ELITE SHORT PLAT +3f G.7
FIELD600K.
RENTON 16204 114TH AVE SE, RENTON, WA 98055 WE
DRAWING N0:
ONE INCH �ATUn�
AT FULL P onning Building/PuUlic Works Dept,FRONTAGE IMPROVEMENTS
IF NOT ONEE iNC INCH
SCALE ACCORDINGO M 162ND ST r.FgT- pF;
R-398021
iL . -
REFER TO SHEETS 08
FOR FRONTAI E DRAINAGE IMFRO�EMENTS SE 162ND ST
-ar. R
i
1
1
1
1 I
UJI I —
1 � �
1 r ,
1
NAVD-88
�IJ5, 5 E E S
CREIK_- ,NITARY SEW;" R
-PLANS
DOMESTIC SERVICE CONNECTION PER SOCS
• CREED{ STANDARD PLANS. CONFIRM METER AND
SERVICE SIZING WITH PLUMBING DESIGNER I~TYP
r�
1
1
I
ECORD DRAWING
FORMATION ADD, DI By TERRANE, INC.
EFIRESENTS€ RESUL S F `A SURVEY CONDUCTED
U . 2018 Lu p LOT 1
P
1ILAgLDG. CONNECTION
IE 477.69
1 13448 � I
4$O.1F 5" SEI 1
1 C9 TYPE 'I
1 = RIM 4BE.4'RIM=480,19 - - FOR FUTURE STUB FOR FUTURE
IE 477.57 E,Li cONNECTION BLDG. CONNECTION
1 " IE=477,54 _ I IF - - IE 478,45
1 I
16 LET 8„ SE)
74 g
PROPERTY LIME 4
cot -
r I I
1 `—Co TYPE 1 01
RIM 480.36 RIM=480,47 - c_:iI I
IF 477-25 RIM=477,32 I tr'I
� I � SHARED UTILITY - J
1 I EASEMENT (TYP)
CB TYPE 1 T f
r f RIM 479.64 RIM,6 1- r��: + I I
1 - ' IE 476.45 I E= 4 7 6, 4 5 -- —� -��- I ATEH-BASIN TYPE I
I J; — CATCH BASIN TYPE 1
STUB FAR FUTk1RE� RIM=479,983 RIM e RIM=481,04
_ IE- - IE S 476,8 I
1 II I _BLDG,-CGIN ECTIOhI _ - - - - IF �- IE=477,84
I: IE 476.91
51 LF 8SD -
1 - - -- — - - --` - - - ED MANHOLE 54' W/
_
FLOWCOP;7CjL 'ZrPUCT,IPF PRIVATE
I 4�I
1 rf yg RIM=479,55 r f' UNDERGROUND,_DETENTI$ FACILITY uII + I
' r f 4 =J f fi.5-E-LQiAM1ETEiR _ MAN I OLD SYSTEM I �•
f IE 78" 469,32 ' (6 DEAD STOPAGE) i - '
1 - �'-S _1 i4• _L__(12'-S, Du.T� 18„ - 469.9 7 - - - - - - - -
i
REFER 1-0 SOUS
CREEK SANITARY
SEWER PLANS
FOR SIDE SEWER
AND SEWER
MAIN EXTENSION
PLANS
PROTECT
EX UTILITY
PGLEI TO
RE ,AIN
Know what's below.
Call before you dia.
- - ---- _ - _ _- IF 469.81 �36" E, IN) 36" E=469,9T
- —
1� I
1�
'a I
14 ��
- I
SHARED UTIOTY
1 EASEMENT (TYP). LOT 1
L — I
DETENTION ACCESS WATER SERVICE f
RISER (TYP) (TYP) ,
20 L F 8" SD STUB FOR
FUTURE BLOC,
CONNECTION � I
IE 476-39
AMk CATCH BASIN TYPE 1
C9 TYPE 1 SWALE
RIM 479,25 I y'' - ' — — RIM a> a RIIM=480,94- '
IE 476 I� IE=477,84
I I.:_L.-: - -
►I
-- F, %
\\\
,X \
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraenglneeri rig.Com
'�k Ap
7
SHARED DRIVEWAYS
6
CITY COMMENTS
5
CITY COMMENTS
35163
4
C" COMMENTS
IONAL
REVISION,
SURVDED,
MB
3 29 17
PA
Me
M8
9 09 16
PA
MB
8 15 16
PA
me
M8
7 07 16
PA
c►caeo-
PA
h)
DATF
i APPR
ARPRO44L.
5CALE
1p=1D1
ONE iNC^H
tT FULL SCALE
1F NOT ONE INCH
SOLE 1CCOMNGLT
VERTICAL "A o 19H8
HOWZONTAL- NAD IQ$7r1991
I
TLJ M
IN COMPLIANCE WITH CITY DP RENTON STANDARDS
DEVELOPMENT ENGINEERING
arianne Bannwarth 06122i2017 '
SURFACE SKATER UTILITY
R
rstraka 0612012017
CURRENT PLANNING
mdavis 06/20/2017 01,
Wms
I. SEE SHEET CI AND C2 FOR GENERAL NOTES, GENERAL STORMWATER
NOTES, AND GENERAL SANITARY SEWED NOTES,
2. ALL ROOF DOWNSPOUT CONNECTIONS TO THE FUTURE BUILDING STUB
OATS SHALL BE PERFORATED PIPE, MAINTAIN 5' MIN, SEPARATION FROM
BUILDING-
3. ALL WORT{ SHALL BE IN ACCORDANCE WITH CITY OF RENTON AND SODS
CREEP{ SEWER AND WATER STANDARDS AND REQUIREMENTS.
4. SEE S005 CREEK SEWER PLANS FOR SANITARY SEWER MAIN WORK AND
SIDE 5EWER STUBS WITHIN THE RIGHT-OF-WAY.
5- VERIFY SIZE OF NEW WATER METER AND SERVICES WITH PLUMBING
DESIGNER AT TIME OF BUILDING PERMIT.
B- COORDINATE METER INSTALLATION WITH BUILDING PFRMIT. PROVIDE 18"
MIN. COVER OVER DOMESTIC WATER SERVICE. (DOMESTIC WATER SERVICES
SHOWN FOR INFORMATION ONLY.)
LEGEND
4
CB TYPE-1 �_ 1 �
DETENTION TANK MAINTENANCE ACCESS
CB TYPE-? 48"
STORM DRAIN MAIN
-' — — • — — ' — - STORM DRAIN SERVICE
SANITARY SEWER MAIN
• not mo 0 SANITARY SERVICE LINE
0 CLEANOUT
-- — — WATER SERVICE LINE
WATER/FIRE MAIN
— — — — — SWALE
i
WATER MI`TEF?
ASPHALT CONC PAVEMENT �
�15
TABLE OF DRAINAGE AREAS
TOTAL LOT
AREA
MAX IMPERVI
BY ZONING
REDUCED
MAX IMPERV
REDUCTION
IN IMPERV
LOT 1
5,039
3,779
2,728
1,052
LOT 2
5,032
3,774
2,724
1,050
LOT 3
5,940
4.455
3,215
1,240
LOT 4
1 8,834
6.625
1 4,782
1 1,843
LC�T 5
5,On5
3.799
2,742
1,C157
(ALL AREAS IN SF) TOTAL
FLOW CONTROL BMP
IMPERVIOUS
AREA CREDIT
1,052
1,050
785
0
1,D57
3,343
CONSTRUCTION PERM T SUBM TTAL
DATE:
D TY OF LIMELITE SHORT PLAT/e/17
F iEILH1�K.
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAYE:
4PAWING NO:
Planning/Building/Pijbllc Works Dept. DIMINAGE AND UTILITY PLAN C5
R-398020
Section 9 Township' - E W10
T
0
n
O
T
Q)
E
I
4_j
N
Q)
C�
GRAPHIC SCALE
30 0 15 30
SCALE: 1" = 30'
—I _
4' ASPHALT SAFE
ASPHALT WALKING PATH
DRI VEWA Y I
EXISI TING -
CROSS WALK
r=(1
GRAVE � 2 O
D,
PARK/NG� .y.
F PA TCH 6 6
43 I GRAVEL FOGLINE 1 ' NORTH I ;C(3NC
DRI VEWA Y 0 OF EXISTING EDGE
NEW EDGE OF '
, I OF PAVEMENT I
PA VEMENT. 3 OFF I
EXISTING EDGE OF
yw LZiT z LOT 1 PAVEMENT
I
I I I I
I I
I
ROUTE TO NELSON MIDDLE
SCHOOL VIA A COMBINATION I y ` LIMELITE SHORT
Y�= I
OF SIDEWALK AND PAVED LOT4 PLAT BY OTHERS
SHOULDER ALONG 144TH AVE t
AAln Anei 1-.1ru CT \ I I I I
n1vL1 1Vrr iv-riii -)I.
I s
:ss
I LOT 5 I
CONSTRUCTION NOTES:
I � EXISTING ASPHAL T ORIVEWA Y TO REMAIN. PROVIDE SMOOTH TRANSITION BETWEEN NEW AND OLD
ASPHAL T.
O EXISTING GRA W-L. 3' WIDE SAFE WALKING PA TH TO BE CONSTRUCTED ACROSS EXISTING GRA VEL.
ADDITIONAL 3/4" CRUSHED ROCK MA Y BE REQUIRED TO PROVIDE SMOOTH TRANSITION BETWEEN NEW
EDGE OF ASPHAL T AND EXISTING GRA VEL.
4" WHITE FOG LINE STRIPE TO SE CONSTRUCTED AFTER PLACEMENT OF ASPHALT TO DELINEATE EDGE
R/W R/W OF SAFE WALKING PATH.
60' R/W
® CONTRACTOR TO TRIM BACK EXISTING VEGETATION WITHIN THE ROW TO PROVIDE CLEAR SPACE FOR
WALKING PA TH. TRIMMING SHALL BE I' SOUTH OF WALKING PA TH EDGE AND 8' HIGH.
4' SAFE
�—W LKI G� 5� CONSTRUCT AN ADDITIONAL 3' ASPHALT SHOULDER TO PRO VVE THE REOUIRED 4' SAFE WALKING PATH
ASPHALT PAVEMENT PER SECTION THIS SHEET
VARIES 21-23' © MOVE EXISTING MAILBOXES BEHIND NEW ASPHAL T WALKWA Y WHERE NECESSARY SO THA T FACE OF
MAILBOXES ARE CLEAR OF NEW WALKING PATH.
3' NEW
ASPHALT 0 PROVIDE SMOOTH TRANSITION BETWEEN ASPHALT RAMP OF SHORT PLAT AND SAFE WALKING PATH.
f 4" WHITE PAINTED FOGLINE
CALL 3 WORKING DAYS BEFORE YOU DIG
811
UTILITIES UNDERGROUND LOCATION CENTER
(ID,MT,ND,OR,WA)
ELECTRIC -RED SEWER - GREEN GASIOIL-YELLOW SURVEY -PINK
SAFETY PRECAUTION SHALL BE IMPLEMENTED BY TECATV- ORANGE PROPOSED - WHITE WATER -BLUE
CONTRACTOR(S) AT ALL TRENCHING IN ACCORDANCE
WITH CURRENT OSHA STANDARDS
AS I� t
x d
29476 �
�GI STERN i
SIGNAL
STAMP NOT VALID
UNLESS SIGNED AND DATED
ROADWAY PAVEMENT SHALL BE IN CONFORMANCE WITH C.O.R. ROAD STANDARD
SE 162ND STREET SECTION
(LOOKING WEST)
NOT TO SCALE
LITCHFIELD ENGINEERING
12840 81ST AVENUE NE
Kirkland, WA 98034
Tel (425) 821-5038 Fax (425) 821-5739
Copyright c� 2000 Litchfield Engineering, Inc. All rights reserved.
4
2
1 1 PRELIMINARY ISSUE
Ile],
THIS SAFE WALK TO SCHOOL PLAN /S A GRAPHICAL DEPICTION OF THE ANTICIPA TED WORK TO
CONSTRUCT A 4' WIDE ASPHALT PATH TO CASCADE ELEMENTARY SCHOOL. THE INFORMATION
DEPICTED AND SHOWN IS BASED ON FIELD CONDITIONS OBSERVED ON MAY 24, 2017 BASIC
FIELD MEASUREMENTS, ON-LINE RECORDS AND DA TA PROVIDED BY OTHERS (l. E. LIMELITE
SHORT PLAT). AN ACTUAL FIELD SURVEY WAS NOT PERFORMED BUT /S RECOMMENDED AT
THE TIME OF CONSTRUCTION.
SURVEYED: SCALE:
VERTICAL: NAVD 1988
DESIGNED:
HORIZONTAL: NAD 1983/1991
KAL
DRAWN:
KAL
ONE INCH DATU M
KAL 5-31-17 KAL CHECKED: AT FULL SCALE
KAL IF NOT ONE INCH
REVISION BY DATE AP P R APPROVED: KAL SCALE ACCORDINGLY
CITY OF
RENTON
Planning/Building/Public Works Dept.
SITE
VICINITY MAP
NOT TO SCALE
CASCADE
ELEMENTARY
PROJECT CONTACTS
APPLICANT." LIMELITE DEVELOPMENT, LLC
14508 NE 20TH ST #200
BELLEVUE, WA 98004
(206) 778-3222
CONTACT. TODD KARAM
CIVIL ENGINEER (SHORT PLAT):
COTERRA ENGINEERING, PLLC
(FORMERLY SPRINGLINE DESIGN, LLC)
321 3RD AVENUE SOUTH, SUITE 307
SEA TTLE, WA 98104
(206) 596- 7115
CONTACT PETER APOSTOL
CIVIL ENGINEER (SAFE WALKING PATH):
LITCHFIELD ENGINEERING
12840 81 ST AVE NE
KIRKLAND, WA 98034
(425) 821-5038
CONTACT. KEITH LITCHFIELD, PE
SURVEYOR: TERRANE (FORMERLY GEODIMENSIONS)
10801 MAIN STREET, SUITE 102
BELLEVUE, WA 98004
(425) 458-4488
IN COMPLIANCE WITH CITY OF RENTCN STANDARDS
CURRENT PLANNING AlIM
mdavis 06/20/2017
DEVELOPMENT ENGINEERING,
jtjohnson 05/17/2017
Limelite Short Plat
16204 114th Ave se
Renton, WA 98055
DATE: ZZ
FlELD OOK:J 1 — 17
PAGE:
DRAWING NO:
SAFE WALK TO SCHOOL PLAN SHEET: 1 OF:1
R-398019
2
FINISH
GRADE
z
M
N
TREE STAKE
PREVAILING ROOTBALL
WIND TRUNK
TREE STAKE
PLASTIC TREE TIES
WOOD STAKE, STAKES SHOULD
ROOT FLARE SHALL BE LOCATED
ABOVE GROUND LINE
3" MULCH LAYER, KEEP AWAY
z
EH 3" WATER BASIN
SCARIFY SIDE & BOTTOM OF
PLANTING PIT TO ALLOW FOR
ROOT PENETRATION
I I
I 1=1 I
s�opFl Irr. I'�• �oQ I CONCRETE SIDEWALK
3x MINIMUM ROOTBALL DIAMETER
RECOMPACT SUBGRADE
NOTES:
n TREE PIT SHALL NOT BE LESS [-4.] TREE STAKES PERPENDICULAR
THAN 3 TIMES ROOT BALL DIA.1 ITO THE PREVAILING WIND
2❑ CUT ALL TIES AND FOLD RACK RLAP 5❑ PLANT TREES 2" HIGHER THAN
FROM UPPER 1 3 OF ROOT BALL DEPTH GROWN IN NURSERY
3❑ REMOVE ALL PLASTIC AND TWINE
TYPICAL DECIDUOUS TREE PLANTING DETAIL
NTS
REMOVE BURAP
TWINE OFF TOP 1 3
3-4" MULCH
FINISH GRADE
ROOT PENETRATIONI
RECOMPACT SUBGRADE
ENSURE THAT ROOT
FLARE WILL NOT SETTLE
BELOW GROUND LINE
TYPICAL SHRUB PLANTING DETAIL
NTS
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Print Form Reset Form Save Form
CITY OF
-----Renton
TREE RETENTION WORKSHEET
Planning Division
1055 South Grady Way -Renton, WA 98057
Phone:425-430-7200 1 www.rentonwa.gov
1.
Total number of trees over 6" diameter', or alder or cottonwood
trees at least 8" in diameter on project site
11
trees
2.
Deductions: Certain trees are excluded from the retention calculation:
Trees that are dangerouS2
trees
Trees in proposed public streets
trees
Trees in proposed private access easements/tracts
trees
Trees in critical areas' and buffers
trees
Total number of excluded trees:
o
trees
3.
Subtract line 2 from line 1:
11
trees
4.
Next, to determine the number of trees that must be retained 4, multiply
line 3 by:
0.3 in zones RC, R-1, R-4, R-6 or R-8
0.2 in all other residential zones
0.1 in all commercial and industrial zones
3
trees
5.
List the number of 6" in diameter, or alder or cottonwood trees
over 8" in diameter that you are proposing5 to retain 4:
8
trees
6.
Subtract line S from line 4 for trees to be replaced:
(if line 6 is zero or less, stop here. No replacement trees are required)
(5)
trees
7.
Multiply line 6 by 12" for number of required replacement inches:
(56)
inches
8.
Proposed size of trees to meet additional planting requirement:
(Minimum 2" caliper trees required for replacement, otherwise enter 0)
0
inches per tree
9.
Divide line 7 by line 8 for number of replacement trees6:
(If remainder is .5 or greater, round up to the next whole number)
o
trees
Measured at 4.5' above grade.
Z A tree certified, in a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed
landscape architect, or certified arborist, and approved by the City.
3 Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050.
"Count only those trees to be retained outside of critical areas and buffers.
s The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-1301-17a.
6 When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2") caliper or an evergreen at least
six feet (6') tall, shall be planted. See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees.
1
H:\CED\Data\Forms-Templates\Self-Help Handouts\Planning\Tree Retention Worksheet.docx 08/201E
CANOPY DRIP LINE
NO TRESPASSING
'ROTECTED TREE'
iIGN POSTED EVERY 50
"EET (MINIMUM OF 2).
VEGETATION AND TREE
FENCING SHALL BE A
MINIMUM OF 6' HIGH
TEMPORARY CHAIN LINK
FENCING WITH 10' LACING
BETWEEN POSTS.
PROTECTION MEASURES DURING CONSTRUCTION:
1. CONSTRUCTION STORAGE PROHIBITED: DO NOT FILL, EXCAVATE, STACK OR
STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS,
OPERATE ANY EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE
EARTH IN ANY WAY WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY TREE TO
\ BE RETAINED.
J 2. FENCED PROTECTION AREA REQUIRED:PRIOR TO DEVELOPMENT ACTIVITIES, A 6'
HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES
OF ALL RETAINED TREES OR AT A DISTANCE SURROUNDING THE TREE EQUAL TO
ONE AND ONE -QUARTER FEET FOR EVERY ONE INCH OF TRUNK CALIPER,
WHICHEVER IS GREATER, OR ALONG THE PERIMETER OF A TREE PROTECTION
j TRACT. PLACECARDS SHALL BE PLACED ON FENCING IF LESS THAN 50' INDICATING
THE WORDS, 'NO TRESPASSING -PROTECTED TREES' OR ON EACH SIDE OF THE
FENCING IS LESS THAN 50'. SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR
GROUPS OF TREES SHALL BE FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE
FENCED ON 4 SIDES.
3. PROTECTION FROM GRADE CHANGES: IF THE GRADE LEVEL ADJOINING TO A TREE
TO BE RETAINED IS TO BE RAISED, A DRY ROCK WALL OR ROCK WELL SHALL BE
CONSTRUCTED AROUND THE TREE. THE DIAMETER FO THIS WALL OR WELL MUST
BE EQUAL TO THE TREE'S DRIP LINE.
4. MULCH LAYER REQUIRED; ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE
COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF 3" OF BARK MULCH
PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING.
PROTECTED ROOT ZONE WITHIN THE CANOPY DRIP LINE -
ACTUAL FEEDER ROOTS EXTEND WELL BEYOND DRIP LINE
RENTON TREE PRESERVATION DETAIL
NTS
n
INSTALL GROUNDCOVERS
DEPTH
PLAN VIEW OF SPACING
NC�I�I]:]�.Y.yh[e»ii111�Ii:�
JMULCH. VERIFY SAUCERI
L
TYPICAL GROUNDCOVER PLANTING DETAIL
NTS
Tr" #
Species
(federal code)
Size
inches
Current health rating
(good, fair, had)
Drip line
radius
- North
Duip
line
Son t1h
Drip
line
East
Drip
fine
Wes,
1
AEHI
2 3.5
good
17
20
20
1S
AEHI
19-51
arood
1.1
13
15
18
3
P ME
26-5
good
18
25
15
1S
4
PE
'0
Lyood
18
Is
15
15
5
P ME
22-8
good
18
15
15
6
PE
29
flood
18
24.6
15
15
7
P I E
24.5
good
18
25
15
15
8
PS M E
1.8
good
18
15
15
15
9
P ME
21-8
i2ood
t S
=0
15
15
10
P ME
30-5
good
18
'S
15
15
11
PhE
I4-9
goad
1s
= 1
35
15
trees on sites
Douglas fir, Pseudc suga menzi+esii. P ME
horse chestnut. Aesculus hippocastanum, AEHI
NOTES:
MULCH TREE PIT MIN 5-0" LENGTH X
FULL PLANTING STRIP WIDTH BETWEEN
CURB AND SIDEWALK (FOR PLANTING
STRIPS LESS THAN 6'-0" WIDE) OR
PROVIDE 5-0"DIA MULCH RING FOR
PLANTING STRIPS WIDER THAN 6'-0".
STAKE TREE WITH (2) TREATED
2" LODGEPOLE PINE DOWLED
TREE STAKES (8'-0" LENGTH)
LOOP EACH TIE AROUND HALF
TREE LOOSELY TO PROVIDE 1"
SLACK FOR TRUNK GROWTH.
"CHAINLOCK" OR EQUAL TREE TIE
MATERIAL (1" SIZED) NAIL OR
STAPLE TREE TIE MATERIAL TO
STAKE TO HOLD VERTICALLY.
LOOP EACH TIE AROUND HALF -
TREE LOOSELY TO PROVIDE 1"
SLACK FOR TRUNK GROWTH.
2"-3" MULCH DEPTH
(TAPERED AT TRUNK)
SIDEWALK
18" ROOT BARRIER
AT SIDEWALK
ROUGHEN SIDES OF PLANTING
HOLE TO MAXIMIZE EXCAVATED
AREA WITHOUT UNDERMINING
ADJACENT PAVING/CURB
ROOT BARRIER; PLACE AT EDGE
OF PAVEMENT/SIDEWALK/ETC.;
PLACE PRIOR TO PLACEMENT OF
NEW SIDEWALK OR CURB TO
PREVENT UNDERMINING.
TOP SOIL TYPE B, OR AS '
APPROVED BY ENGINEER.
REMOVE ALL WIRE, STRINGS,
AND OTHER NON -BURLAP
MATERIAL; AND REMOVE
BURLAP FROM TOP 2/3 OF
ROOTBALL.
CL
�I
2'-0" MIN2"
S-6" MIN
MIN WIDTH OF TREE PIT = 2 TIMES ROOTBALL DIAMETER _
OR 5-0", WHICHEVER IS GREATER
MULCH AREA TO BE CLEAR OF GRASS, WEEDS, ETC. TO
REDUCE COMPETITION WITH TREE ROOTS
NOTES:
1. PLANTING INCLUDES REMOVAL OF
STAKES ONE YEAR AFTER INSTALLATION.
2. SHAPE SOIL SURFACE TO PROVIDE 3"
DIAM WATERING RING.
3. TREE CLEARANCE SHALL BE PER STD
PLAN NO 030.
4. SEE STD PLAN NO 424 FOR TREE PIT
DETAIL.
5. ADJUST TREE TIES DURING
ESTABLISHMENT TO ALLOW ROOM FOR
GROWTH (@ 1" SLACK).
6. ROOT BARRIER REQUIRED ALONG EDGE
OF ROADWAY, CURB, DRIVEWAY, TRAIL,
SIDEWALK, OR OTHER STRUCTURES
WHERE ROOTBALL IS WITHIN TWO FEET;
PLACE VERTICAL ROOT BARRIER AS
SHOWN IN STANDARD PLANS 424A OR
424B UNLESS OTHERWISE INDICATED IN
THE CONTRACT OR DIRECTED BY THE
ENGINEER.
SET TOP OF ROOT CROWN
2" ABOVE ADJACENT CURB
& SIDEWALK GRADE.
3" TO 4" HIGH
WATERING RING
(SEE NOTE 2)
24" ROOT BARRIER
AT CURB.
DECIDUOUS TREE PLANTING IN PLANTING STRIP
NTS
TREE PIT DEPTH =
ROOTBALL DEPTH
(MEASURE BEFORE
DIGGING TO AVOID
OVEREXCAVATION).
DRIVE STAKES 6" TO
1'-0" INTO UNDISTURBED
SOIL BELOW ROOTBALL.
DRIVE STAKE AT ROOTBALL
EDGE (TYP) (SEE NOTE 1)
UNDISTURBED SUBGRADE
(PROVIDES FIRM BASE SO THAT
ROOTBALL WILL NOT SINK.
STANDARD PLAN NO 100a, CITY OF SEATTLE
1. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL OTHER SITE I MPROYEMENTS AND CONDITIONS PRI O
TO 5TARTING LANDSCAPE WORK.
2. CONTRACTOR SHALL USE CAUTION WHILE EXGAVAT I N6 TO AVOID DISTURBING ANY UTILITIES ENCOUNTERED. CONTRACTOR 15 TO
PROMPTLY ADV 1 SE OWNER OF ANY DISTURBED UTILITIES. LOCATION 5ERV I GE PHONE I -aOO-424-5555.
5. CONTRACTOR SHALL MAINTAIN AND WATER ALL PLANT MATERIAL FOR I YEAR OR UNTIL FINAL INSPECTION AND ACCEPTANCE BY
OWNER.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING allANT I T I ES OF PLANTS THAT ARE REPRESENTED BY 5YMBOL5 ON THE
DRAW I N&.
5. 5UBGRADE 15 TO BE WITHIN 10
-L INCH OF I FOOT AS PRO\/I DED BY OTHERS. ALL PLANTING AREAS TO BE CLEARED OF ALL
CONSTRUCTION MATERIAL AND ROCKS $ STICKS LARGER THAN 2 INCH DIAMETER.
6. 4 INCH DEPTH TOPSOIL IN LANDSCAPE AREA.
7. 2 INCH DEPTH, 2 FOOT DIAMETER BARK RING AROUND BASE OF STREET TREES AND OTHER TREES LOCATED IN LAWN.
5. GROUND COVERS SHALL BE PLANTED IN AN EGU I LATERAL TR I ANGULAR SPACING PATTERN AT THE ON -CENTER DISTANCES SHOWN ON
THE PLAN OR IN THE PLANT SCHEDULE. WHERE GROUND COVER ABUTS CURBING, 511DEWAL<S, SIGNS OR POLES, MINIMUM PLANTING
DISTANCES SHALL BE 12" FROM CENTER OF PLANT TO CURB, S 1 DEWALK, ETC. MINIMUM PLANT I N6 DISTANCE SHALL BE 24" FROM CENTER
OF TREES AND SHRUBS.
q. ALL PLANT MATERIAL SHALL BE FERTILIZED WITH AGRO TRANSPLANT FERTILIZER 4-2-2 PER MANUFACTURERS SPECIFICATIONS.
10. ALL PLANT MATERIAL SHALL CONFORM TO AAN STANDARDS FOR NURSERY STOCK LATEST EDITION. ALL PLANT MATERIAL FURNISHED
SHALL BE HEALTHY REPRESENTATI \/ES, TYPICAL OF THEIR SPECIES OF VARIETY AND SHALL HAVE A NORMAL GROWTH HABIT. THEY SHALL
BE FULL, WELL BRANGHEID, WELL PROPORTIONED, AND HAVE A VIGOROUS WELL DEVELOPED ROOT SYSTEM. ALL PLANTS SHALL BE HARDY
UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN THE LOCALITY OF THE PROJECT. TREES, SHRUBS AND GROUNDCOVER aUANT I TI ES,
SPECIES, VARIETIES, SIZES AND CONDITIONS TO BE AS SHOWN ON THE PLANTING PLAN. PLANTS TO BE FREE OF DISEASE, INJURY, INSECTS,
DEGAY, HARMFUL DEFECTS AND ALL WEEDS. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM LANDSCAPE
ARCHITECT O OWNER.
11. NO PERMANENT IRRIGATION 5YSTEM 15 PROPOSED. TEMPORARY IRRIGATION SHALL BE REOU I RED FOR THE FIRST 5 YEARS OR UNTIL
PROPOSED PLANT MATERIAL 15 ESTABL I SHED. PLANT MATERIAL SPECIFIED TO BE NATIVE OR DROUGHT TOLERANT AS DETERMINED BY
LANDSCAPE ARCHITECT.
12. THE AVERAGE SPAG I N6 FOR STREET TREES SHOULD BE 40 FEET ON CENTER AND ADJUSTED TO ALLOW FOR SIGHT LINES, UTILITIES,
TRAFFIC 51 GNS, LIGHT STANDARDS, DRIVEWAYS AND OTHER STREET APPURTENANCES.
15. TREES IN THE RIGHT OF WAY MUST BE PLANTED TO THE FOLLOWING STANDARDS: PLANT TREES IN THE CENTER OF THE PLANTING STRIP
WIDTH. 6 FEET FROM FIRE HYDRANTS AND UNDERGROUND UTILITIES 00> WATER, SEWER, ELECTRIC, GAS). 10 FEET FROM UTILITY POLES,
DRIVEWAYS, AND ALLEY MARGIN, 25 FEET FROM STREET LIGHTS, 40 FEET FROM THE CORNER OF INTERSECTIONS, STOP 5I GNS, AND YIELD
SI GNS. AT LEAST 72 HOURS BEFORE YOU PLAN TO DIG, YOU MUST GALL 811 TO REQUEST THAT THE LAST LOCATION OF ANY UNDERGROUND
OR OVERHEAD UTILITIES (GAS, WATER, ELEGTRI G, ETC.) BE MARKED ON YOUR PLANTING AREA. <NOWI NG THESE LOCATIONS IN ADVANCE
MAY SAVE YOU TIME AND MONEY BY PREVENTING AN ACCIDENT.
d)
# U-
p
�
•� 4z
C:
Z 1-
M
��
0)1It
�
ri
U- A) -6
O
4-1
�
10
O
Nr0)
PROJECT TITLE
State of
Washington
registered
Landscape Architect
Pevin Peterson
certificate no. 1222
Z
a a
J �
a Z
O
W W
a
LU
Q N
N a
H
Z
a 0
N
J
N
NG I.II.117
NG E D 03.16. J 1
REVISED DATE
REVISED DATE
L2
R-398018
z
M
o
-
r
0
0
_j
-0
rf)
cl:
0
re)
Ci
fn
cV
co
Uj
V)
V)
_j
0)
__j
0
V)
Ld
II-_
Uj
(D
rr
O
0
E-4
C)
n
001,
M
1-,
n
Z R
OF
WN
wo
>-.
W
Z ZO
Z
Z
3�
D
0
UZI
S2
Y)
w
0
C3
y
0
0
a-
0-
<
a_
a_
<
REFER TO WSDOI LOCKING LID STANDARD
DUTY JUNCTION BOX TYPES I & 2
,NtANDARD PLAN J-40.10-03
SPLICE KITS CLEAR EPDXY
S W, E Kip ON ALL THRU
SPLICE
4' CONCRETE PAD
l gget,5p
IM
2' MIN, #J5 BARE COPPER
GROUND "RE
:I rll
1 -#a EQUIPMEN 'U 'j WIREW/MCN INSULATION
FROM SERVICE CABINET
2 - LIGHTING SYSrEV-
WIRES TO CONTACTOR
(SIZED AS REOV.)
5/W'x8' COPPER CLAD
GROUND ROD
LUMINAIRE WIRES WILL BE A CONTINUOUS RUN
FROM FUSE HOLDER TO FIXTURE WITH
NO SPLICES.
GROUND ROD
FUSE KITS QUICK DISCONNECT
TO LUMINAIRE
3 AMP W USE FUSE KITS
LUMINAIRE WIRES WILLBE.#42
S.E.C. OR EQUAL
AW IN A JACKETED CABUEi
#0 GREEN INSULATED WIRE
�1
TO FIXTURE GROUND LUG
GROUND LUG
WM
IMUM
tXR0�10
HOtE
2' MIN. GROUT
TOP Of CONCRETE 1`000AnoN To
_
Sr_
UNDER POLE BASE—,
BCE LEOAM! VV_ WTH TOP OF SIDEWALK
I
i
PL
GROUND
CLAMP
II------------
2"YPVCSTEM CONDUIT I II II
S
CONCRETE ---------------- J_L
FOUNDATION
5' SO. OR DIA.
U—OTES.
1. EQUIPMENT GROUND WIRE do BARE "RE SHALL BE
SECURELY FASTENED TO 1HE: GROUND LUG INSIDE THE
POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS
SHALL REMAIN ACCESSIBLE FOR INSPECTION AND
MAINTENANCE.
2. IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR
THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED
WRE OF FHE SAME SIZE SHALL BE RUN FROM THE FIXTURE
TO THE GROUND LUG INSIDE THE. POLE HANDHOLE. IF THE
FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN
INSULATED %RE SHALL BE RUN FROM THE FIXTURE
GROUND LUG TO THE POLE GROUND LUG.
in. FILM - Ito
PUBLIC WORKS TYPICAL LIGHT11ING
DEPARTMENT UNDERGROUND SYSTEM
A :
I APPRO�,.ED:.
......................... .......................
..........
-------
....... ------
....... ....
0 0
C)
3'
STREET LIGHT POLE\
�JUNCTION BOX
PLAN VIEW
4" DEEP
SIDE VIEW
LIGHTING STANDARD & JUNCTION BOX
PLAN VIEW
INDIVIDUAL JUNCTION BOX
NOTE:
CLASS V CONCRETE TO BE
USED IN CONSTRUCTION OF PAD
PUBLIC WORKS CONCRETE PAD DETAILS SM. PLAN - 120
DEPARTMENT
WYE SPLICE
SPLICE KIT
FUSE KIT
FUSE KIT & SPLICE KIT DETAILS
y
0 7 *,ON-s
ADOPTED
CITY OF RENTON
+ +
MR
1R, Standard plans
6) LST DATE: 11/5/96
DATE I REVISION IBY DWG. NAME: JR-12 SP PAGE:JO13
:4-j-
A
---------------
1 1 1 �_,
_Lj I
U a: is I
ow
u z
< gi:i
0-1
Of
z
C-4 L0
R < Z
5 0 Q of. 2
Z11 5 g DOW_ H is
M 0
& ME
011 . :5 Ls
ro
0
Of_ z
>
JX!: UiI -2- -
0
>
0 z
C a
50
---- C ct LUtR
1
wo?l - L- �3 ;z. .1
0 i
ot _w 2
w
Z<
S
*E
a , 4wi� j of
m<
N r z
Le;
E
z
C)
-------------
L
z
.4
01
PUBLIC WORD SERVICE CABINET SM. PLAN 122.1
DEPARTUM WITHOUT IIIIIIIIIIIIIS
STREET LIGHTING CONTACTOR CABINET
WIRING SCHEMATIC
TYPE III SERVICE 120Z240 VOLT
100 A MAIN BREAKER (MIN.)
2 POLE 240 VOLT II
BRANCH BREAKERS
120/240 VOLT
TEST
16 POLE
SWTCH
TERMINAL
BLOCK —
CIRCUIT WIRES TO LIGHTING RUNS
PHOTO -CELL
MOUNTED ON
NEAREST
LUMINAIRE
<
fh
F
z
1
UTILITY
PLUG (GFI)
STREET LIGHTING
CONTACTORS
TO GROUND
ROD
WIRING COLOR CODE
A. WHITE JACKET (NEUTRAL)
B. BLACK JACKET (LINE)
C. GREEN JACKET (GROUND)
D. RED JACKET (LOAD)
E. GREEN OR BARE WIRE (GROUND)
. 3
PUBLIC WORKS STREET LIGHTING CONTACTOR. PROVESMFLAN — 12
,
DEPARTMENT CABINET SCHEMATIC 4111111-
Taff
NORTHWEST �X
TRA F-F-1c EXERTS
11410 NE 124th St., #590, Kirkland, WA 98034
Phone: 425.522.4118 Fax: 425.522.4311
w
4-17-17
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TRANSPORTATION
ATION OPERATION 1
06/22/2017
Cbarn:s +
CONDUIT ENTR. AREA
k
PLAN VIE
SIZE To FIT SIZE TO FIT
CABINET CABINET
0'
*r4
�_611 --Grade Level
jr
L-
4 F
FRONT VIEW
STREET LIGHT CONTACTOR FOUNDATION
Shim to plumb Shim to plumb
La -IV —See Note 3See Note 3
#4 hoops
+1 1 #4 hoops
#4 bar each corner
10 1 r-Y4 bar each canner
If
45, MIN to 2"
3/8" diameter piastic or -In Q\_3/a" diameter plastic drain
SIR
f-a" cabinet depth
Cabinet depth 1.
+ 2-
#4 bar each corner �
#4 bar each
corner
PLAN VI W PLAN ME
PAD MOUNT PADMOUNTCONTROLLER CABINET FOUNDATION BAIERY 162= (11115) FOUNDATION
For NOTES see Std. Plan 126.2
PUBLIC WORKS CABINET FOUNDATION DETAILS ROVESTD. PLAN 126.1
DEPARTMENT o 1111,2-
1-Ii!
K-JUbU I I
FACTORY FABRICATED WELDED
MANIFOLD END SECTIONS (TYP).
PROVIDE LAYOUT PLAN
SHOWING JOINT LOCATIONS AS
PART OF SUBMITTALS FOR
ENGINEER APPROVAL.
6" PERFORATED UNDERDRAIN,
C16
PROVIDE CLEANOUTS AT ALL 90°
BENDS AND EVERY 75 FT
2
C16 54 DIA. CONTROL
STRUCTURE
36" DIA. STORM PIPE
CONNECTING WELDED STUB
IE 469.81
CONNECT TO CB WITH WATER
TIGHT CONNECTION
8" SD INLET
I E 475.00
SEE PLAN FOR TIGHTLINE
DISCHARGE OF SUBSURFACE
DRAIN PIPE
475
PFR �FS��N
MATCH
CURVATURE
OF PIPE
Ln
0
HOLE DRILLED
AT TIME OF
ASSEMBLE
LADDER BASE PLATE
NTS
iLt vlh. 1
CONTROL C16
STRUCTURE
ELEVATION
36" ACCESS 4
RISER C16
0 0 0 0 0 o BACKFILL PER
ooc DETAIL 5
. . . . o . SHEET C13
BEDDING PER
0.5' DEAD STORAG o DETAIL 5
SHEET C13
0
0
--- -°o
NOTE:
CONTRACTOR SHALL PROVIDE LAYOUT PLAN,
BOUYANCY CALCULATIONS AND FOUNDATION
PLAN TO COUNTERACT BOUYANCY AS
REQUIRED. PROVIDE A MINIMUM 236 LF OF
DETENTION PIPE, 7554 CF. DETENTION PIPE
AND ALL STRUCTURES SHALL MEET CITY OF
RENTON STANDARDS AND SPECIFICATIONS.
. .
If 0.5'
0 0:
o. 0. 0 0
°0°O°
000
.0
000
O
O°°
0°
0°0°
o00
°o°°
o°
.00
o.°o
°0
.
.00
00
0°°
.000
.
00
00
°o
. .
.
000
°
.
o°
o°
°o
o°
o°°
0°
°o
°o°°
0
0
0
0
00
o°o
o°
°o°0
0°cC-°
B
3
0.5'
Q
\-6" PERFORATED TRENCH 78 DIA. ALUMINIZED CMP I
BOTTOM STORM PIPE OR APPROVED 5 6" PERFORATED
A UNDERDRAIN EQUAL (TYP) C16 UNDERDRAIN
C16 468.52
. . . . . . . . . . . . . . . . . . . . . SECTION A . . . .
DETENTION TANK
1 "=5' VERT 1 "=10' HORIZ
7"
TOP PLA X�
7"
SUPPORTS V
r-
R29.75"
BOTTOM PLATE
if)
0
0.25"
4.5"
SUPPORTS TO
HAVE A Y" X
Y" CURVE FOR
TOP PLATE
TO REST ON.
36" RISER PIPE
24" ROUND LOCKING FRAME
AND COVER MARKED
"DRAIN" MOUNTED OVER
24" DIA. ECCENTRIC
OPENING
PRECAST 60" DIA. MANHOLE
TOP SLAB WITH 24" DIA.
ECCENTRIC OPENING
78" DETENTION PIPE
ALUMINIZED CMP
NOTES:
1. HDPE OR PP SHEET STOCK, Y" THICK CNC.
2. WELD TO BOTTOM OF PIPE, BOLT HOLE TO BE MINIMUM 3/8"
HAND DRILLED AT FAB PLANT. SS/GALV BOLT
3. TRIM BASE PLATE AS NEEDED.
LADDER BRACKET
(GALV, SS, PP)
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
PLAN
36" CMP ACCESS RISER
NTS
475
U�i
BOLTS,
4SHERS
NL
R PIPE
iXy�►�GRiII:i
PLACE BOLT ON
CROWN OF RISER
CORRUGATION
SS NUT
REMOVABLE WATERTIGHT
COUPLING OR FLANGE z
cV
- z
MAX.
PLATE WELDED TO ELBOW -
WITH ORIFICE AS SPECIFIED
ELBOW- RESTRICTOR
1. PIPE SIZES AND SLOPES: PER PLANS.
2. EXCEPT AS SHOWN OR NOTED, UNITS SHALL BE CONSTI
ACCORDANCE WITH THE REQUIREMENTS FOR CATCH BAS
54" MIN. DIAMETER.
3. PIPE SUPPORTS AND RESTRICTOR/SEPARATOR SHALL BE
MATERIAL, AND BE ANCHORED AT 3' MAX. SPACING BY
DIAMETER STAINLESS STEEL EXPANSION BOLTS OR EMBE
IN WALL.
4. THE RESTRICTOR/SEPARATOR SHALL BE FABRICATED FR(
ALUMINUM OR .064" ALUMINIZED STEEL.
5. OUTLET SHALL BE CONNECTED TO CULVERT OR STORM
WITH STANDAD COUOPLING BAND FOR CORRUGATED MET
OR GROUTED INTO THE BELL OF CONCRETE PIPE.
6. FRAME AND LADDER OR STEPS OFFSET SO THAT: A. C
GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS
OF RISER AND CLEANOUT GATE. C. FRAME IS CLE
CURB.
7. IF METAL PIPE CONNECTS WITH CEMENT CONCRETE PIPE
PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE
1 /4".
FLOW CONTROL STRUCTURE
NTS
CEM. CONC. GRADE
RINGS AS REQ.
COMPACTED
BACKFILL
78" DETENTION PIPE
ALUMINIZED CMP
ROUND LOCKING FRAME AND
=R MARKED "DRAIN" MOUNTED
Z 24" DIA. ECCENTRIC OPENING
FAIN 1" GAP BETWEEN BOTTOM OF
AND TOP OF RISER. PROVIDE
3LE GASKET TO EXCLUDE DIRT
RISER PIPE
ED ATTACHMENTS,
4 PER LADDER.
VERTICAL SPACING, 36"
=R BASE PLATE, PLACE AS LOW 3
_ . OSSIBLE AND TRIM AS NEEDED, C16
SEE DETAIL
NOTES: SECTION
1. RISER SHALL BE WELDED OR FUSED TO TANK.
2. ALL MATERIALS SHALL MEET CITY OF RENTON STANDARDS AND SPECIFICATIOINS.
3. MAINTAIN 1" GAP BETWEEN BOTTOM OF SLAB & TOP OF RISER. PROVIDE PLIABLE GASKET TO
EXCLUDE DIRT
4. LADDER SHALL BE PLACED SO THAT TOP RUNG IS LESS THAN 8-INCHES FROM TOP OF RISER
AND BOTTOM RUNG IS AS LOW AS POSSIBLE AND LESS THAN 12-INCHES TO BOTTOM INVERT
OF PIPE
5. TOP OF LADDER SHALL BE AT LEAST 2-INCHES BELOW TOP OF RISER.
6. BOTTOM OF LADDER SHALL BE ATTACHED TO BASE PLATE WITH SS/GALV HARDWARE
7. WEIGHT OF LADDER TO REST ON BASE PLATE
SURVEYED: SCALE:
VERTICAL: NAD D 983/1991
1988
7 SHARED DRIVEWAYS MB 3 29 17 PA 1 a_ =10f HORIZONTAL: DESIGNED: MB
6 CITY COMMENTS MB 9 09 16 PA
5 CITY COMMENTS MB 8 15 16 PA DRAWN: MB
4 CITY COMMENTS MB 7/07/16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE A P P R I APPROVED: SCALE ACCORDINGLY
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY }
rStraka 06/20/201 7
DEVELOPMENT ENGINEERING
Brianne Bannwarth 06/22/2017
T
GRAVEL BACKF" '
(WSDOT/AP1
DETENTION TANK PER
DETAIL 1/C16
GEOTEXTILE FABRIC- MIRAFI
140N OR APPRV'D EQUIV.
4" PERF. PVC SCH. 40 W/
SOLVENT WELD JOINTS. EMBED
IN CLEAN WASHED GRAVEL
BACKFILL FOR DRAINS 6" ON
EACH SIDE AND WRAP WITH
MIRAFI 140N WITH 12" OVERLAP.
EXTERIOR FOOTING DRAIN
C16 NTS
F- CONSTRUCTION PERMIT SUBMITTAL
DATE: n
CITY OF LIMELITE SHORT PLAT FlELD3/29/17
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DRAWING N0:
Planning/Building/Public Works Dept. CML DETAILS C16
R-398016
PT
TC
480.74
TC
480.50 BC
480.24
BC
480.00
TC 479.50
BC 479.50
TC
479.80
. 480.18
BC
479.30
480.10
480.26 481.01
480.18 -
480.27
PC
TC
479.55
479 $2
BC
479.05
RAMP GRADING DETAIL
1 "=5'
EXISTING ASPHE
PAVEMENT
SAWCUT
(SEE NOTE 2)
7" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
RESIDENTIAL STREET MINIMUM I
4" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
NOTES:
1. MUST MATCH EXISTING THICKNESS IF GREATER,
2. SAWCUT SHALL BE POSITIONED 1' - 0" BEYOND EDGE OF
DAMAGED PAVEMENT.
3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT
PLACEMENT AT THE GUTTER FACE. SEE STANDARD PLAN
FOR CEMENT CONCRETE CURBS.
4
STD. PLAN - 103
* PUBLIC WORKS CURB AND GUTTER PPRO D:
DEPARTMENT REPLACEMENT DETAIL y
ATE
ASPHALT PATCH
NTS
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
COMPACTED SUBGRADE
NOTE: ALL DEPTHS SHOWN ARE COMPACTED DEPTHS.
PER PLANS PER PLANS
-5" MIN DEPTH PERVIOUS CONCRETE
SIDEWALK (PC)ETE
6" AGGREGATE DISCHARGE SUBBBASE,
WSDOT/APWA GSP 4-04.2 GRAVEL BASE,
SEE SPEC
CROSS SLOPE PER PLAN
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY
rstraka 06/20/2017
DEVELOPMENT ENGINEERINGDO
Brianne Ban nwarth 06/22/2017
EE NOTE 5
6 THICKENED EDGE AT PC SIDEWALK GEOTEXTILE BOTTOM
LIMITS OF VEHICULAR AND SIDES
PAVING (NOT REQ. WHERE COMPACTED SUBGRADE TO 90-92% SCARIFY TOP SURFACE
PVMT ABUTS CURB) NOTES: PRIOR TO PLACEMENT OF GEOTEXTILE PER APWA GSP
1, WHERE PERVIOUS CONCRETE SIDEWALK IS WITHIN THE CRITICAL ROOT ZONE OF TREES TO SAVE
REDUCE AGGREGATE DISCHARGE SUBBBASE TO 2".
2. DEPTHS SHOWN FOR PAVEMENT SECTION ARE COMPACTED DEPTHS.
3. AT DRIVEWAYS THICKENED EDGE OF SIDEWALK ON EACH SIDE OF DRIVEWAY PER TRANSITION
ABOVE.
4. OWNERS GEOTECHNICAL ENGINEER TO REVIEW SUBGRADE PREPARATION PRIOR TO PLACEMTN OF
PC GEOTEXTILE.
5. EXTEND PC SIDEWALK GEOTEXTILE ABOVE PAVEMENT. AFTER PAVEMENT IS CURED AND
ADJACENT FINISHED GRADE IS STABLIZED, CUT GEOTEXTILE AT FINISHED GRADE. (TYP.)
6. SEE SHEET C2 FOR PERVIOUS CONCRETE SPECIFICATIONS.
APPHALT CONCRETE PAVEMENT - PRIVATE ONLY
NTS
Q�VSPNTS DRgI/(.�, r
d`
RENTON
AHEAD OF THE CURVE
n '
DRAIN
PLAN VIEW
1;7 [13mm] LETTERING
SOLTHOLES-3 PLCS EQUALLY SPACED 12a'
APART ON 23 1,
!16" (586mm) DIA B.C.
DIA PICKHOLE
1 V4" 132mm1 LETTERING
25" DIA.
[636-1 t'
17
1
374'
I 119mm]
I 8 3/'r 21?
TYP
COVER SECTION VIEW
26 V2" DIA
[673mm]
25 1/4"DIA
[641mm] t tn8•
va" (6mm) DIA lml
NEOPRENE GASKET
-� B
]162nn]
618. 23 3/8" DIA CL OPEN
[16mm] [594mm]
27 5/16' DIA
[694mm]
3418" DIA
[867mm]
FRAME SECTION VIEW
COVER BOTTOM VIEW
(3) BLT SOC. (ALLEN HEAD)
BIB"-11 X I.5 SS
RUBBER WASHER
EON BOLTING DETAIL
[6mm]
127mm]
1!8"
[3mmi
1/8•
[R3mm]
GASKET GROOVE DETAIL
NOTES
ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRONWORKS INC. Na 3717C1
OR APPROVED EQUAL.
PUBLIC WORKS STORM ROUND FRAME AND COVER' PLAN - 204'50
•' DEPARTMENT
FNZ MARCH 2O08
SOLID ROUND FRAME AND COVER
SHARED DRIVEWAYS
CITY COMMENTS
CITY COMMENTS
CITY COMMENTS
REVISION
PERVIOUS CONCRETE SIDEWALK
NTS
O 4 D
SLOT - SEE DETAIL
Of AND NOTE 1
U .
1"OPENING TYP.)
UU
m
H
O O
TFALL TO STREA DU P ND POLLUTANT
.SDP 3/8' (9mm) RECESSED
LETTERING
NOTES
1 Provide two slots in the grate that are vertically aligned with the holes in the frame.
Location of bolt -down slots varies among different manufacturers.
2. Refer to Standard Specification 9-05.15(2) for additional requirements.
3. The thickness of the grate shall not exceed 1 5/B".
4. Unless otherwise specified, vaned grates shall be used with standard frame
in the travel way, gutter or shoulder. vaned grates shall not be located
within crossroads. Use vaned grates along rolled curbs.
o
0
0
O
O
a
0
BOLT -DOWN SLOT DETAIL
ISOMETRIC SEE NOTE 1
PUBLIC
vvSTD. PLAN t/�L��� PUBLIC WORKS RECTANGULAR - .40
��- $ DEPARTMENT HERRINGBONE GRATE
FNTo MARCH 2O08
HERRINGBONE GRATE - PRIVATE ONLY
SURVEYED:
MB
3 29 17
PA
DESIGNED: MB
MB
9 09 16
PA
MB
81516
PA
°R°W"` MB
MB
7/07/16
PA
CHECKED:
PA
BY
DATE
APPR
APPROVED:
SCALE:
1 u_ 1 Of HOR ZONTAL NAD D 983/1991
ONE INCH DATU M
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
4
4-04.2 GRAVEL BASE (APWA GSP)
PERMEABLE BALLAST
PERMEABLE BALLAST SHALL MEET THE REQUIREMENTS OF SECTION 9-03.9(1) FOR
BALLAST EXCEPT FOR THE FOLLOWING SPECIAL REQUIREMENTS.
THE GRADING AND QUALITY REQUIREMENTS ARE:
GRADING NO. 1 GRADING NO. 2 (AASHTO NO. 3)
SIEVE SIZE PERCENT PASSING SIEVE SIZE PERCENT PASSING
2-1/2" 99-100 2-1/2" 100
2" 65-100 2" 90-100
i" 40-80 1-1/2" 35-70
NO. 4 0-5 1" 0-15
NO. 100 0-2 0-5
%FRACTURE 95 NO. 100 0-3
ALL PERCENTAGES ARE BY WEIGHT. % FRACTURE 95
THE SAND EQUIVALENT VALUE AND DUST RATIO REQUIREMENTS DO NOT APPLY.
LOS ANGELES WEAR, 500 REV. 30% MAXIMUM
DEGRADATION FACTOR 30 MINIMUM
THE FRACTURE REQUIREMENT SHALL BE AT LEAST TWO (2) FRACTURED FACES AND
WILL APPLY TO THE COMBINED AGGREGATE RETAINED ON THE NO. 4 SIEVE IN
ACCORDANCE WITH WSDOT FOP FOR AASHTO T 335.
THE MINIMUM VOID RATIO OF THE AGGREGATE SHALL BE 30 PERCENT AS
DETERMINED BY AASHTO T 19.
PERMEABLE BALLAST MATERIAL MAY BE CONDITIONALLY APPROVED BASED ON
CONTRACTOR SUBMITTED SAMPLED MATERIALS PRIOR TO DELIVERY TO THE SITE.
FINAL ACCEPTANCE WILL BE BASED ON CONFORMANCE TESTING COMPLETED ON
MATERIAL THAT HAS BEEN DELIVERED, INSTALLED, AND COMPACTED ON SITE. THE
EXACT POINT OF ACCEPTANCE WILL BE DETERMINED BY THE ENGINEER. MATERIAL
OUT OF CONFORMANCE WITH THE PROJECT SPECIFICATIONS WILL BE REMOVED AND
REPLACED AT THE CONTRACTOR'S EXPENSE.
TOP
O
E DETAIL AND NO I a,
AND NOTE
J N Ib
h
SECTION a0
NOTES
c
ya•
t tµ•
BOLT -DOWN SLOT DETAIL
SEE NOTE 1
Provide two slots in the grate that are vertically aligned
1. with the holes In the frame. Location of bolt -down slots varies
among different manufacturers.
IsomLr IC
2. Refer to Standard Specifcaton9-05.15(2)for additional requirements.
3. Use only on sags and vertical curbs locations.
4. Unless otherwise specified, vaned grates shall be used with standard frame
in the travel way, gutter or shoulder. vaned grates shall not be located
within crossroads. Use vaned grates along rolled curbs.
- PUBLIC WORKS RECTANGULAR BI-DIRECTIONAL STD. PLAN 204.30
DEPARTMENT VANED GRATE
eMARCH 2O08
VANED GRATE DETAIL
CONSTRUCTION PERMIT SUBMITTAL
DATE:
CITY OF LIMELITE SHORT PLAT FlELD3/29/17
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DRAWING NO:
Planning/Building/Public Works Dept. CML DETAILS C15
R-398015
O
FRAME AND VANlD ®RAT!
A
�P Gt 1T
ONE #3 BAR HOOP P FORW HEIGHT
TWO #3 BAR HOOPS FOR 1T HEIGHT
RECTANGULAR ADJUSTMENT SECTION
03 BAR EACH
03 BAR EA,
196... ..... .....
PRECAST BASE SECTION
#3 BAR EACH CORNEF
18-MIN
#3 BAR HOOP
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCEDOR
IT
PLAIN CONCRETE
ALL MEFAL PIPE
15"
Hx'BSPw
(SIO. SPEC. 905.H1)
tT
soLlDwAUPjrc
76.
(STD. SPEC.9-03.12(1))
PROFILE WALLPVC
IF
(STD. SPEC. fi-05.1Z(2))
#'txxaiUliATED IV LYI:THYLENE
STORM SEWER PIPE
NOTES
1. As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (Placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shell
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
Alter the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-D4.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shell be 5'.
4. The frame and grate must be Installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 124 or steeper.
6. The opening shall be measured at the top of the precast base section.
T All pickup holes shall be grouted full after the basin has been placed.
8. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
*ri'Aawy.
P-PUBLIC WORKS CATCH BASIN TYPE 1 200.00
STD. LANDEPARTMENTMARCH 2O08
CB TYPE 1
NTS
29 114"
TOP
24 1/4"
B
SECTION O
NOTES
1. This frame is designed to accommodate 20" x 24" grates or
covers
2. Provide two holes in the frame that are vertically aligned with t
he grate or cover slots. Tap each hole to accept
a 5/8" - 11 INC x 2" allen head cap screw.
Location of bolt down holes varies among different
manufacturers.
3. Refer to Standard Specification 9-05.15(2) for additional
requirements.
RECESSED ALLEN
HEAD CAP SCREW
71_ l8"_I 1/8" 5/8"-11 NC x 2"
314" GRATE
ISOMETRIC VIEW
C
1 51W FRAME
a
2 11T
SECTION
BOLT -DOWN DETAIL
DETAIL O SFENOTE z
Y� PUBLIC WORKS RECTANGULAR FRAME STD. PLAN - 204.00
DEPARTMENT
�FA,To$ MARCH 2O08
RECTANGULAR FRAME
coterria
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
CATCH BASIN FRA MD VANED GRATE (DETAIL2D6.00)
�
"R
I4ANOIIOLD
RECTANGULARADJU.STMENTSECTI
QR mfXXIIARAD.lU3IMFNT SECDON
GROIR. TYPICAL (SEE NOTE 5)
'J j� �MDRrARITYP_i
SEPARATE BASE INTEGRAL BASE
CAST -IN -PLACE PRECAST wnH RISER
,= 1 PiPFzarE elsm#aG
SEPARATE BASE
PRECAST
aDrrG -srricITYRI
CATCH BASIN DIMENSIONS
CATCH
DIABM IE ER
W�
Mktg E�
BASE
THICIm�
MAXIMUM
"BI��
MINIMUM
DISTANCE
BETWEEN
IWOCKOUTS
BASEREINFORCINGSTEEL
'nr/ft. IN EACH DIRECTION
SEPARATE BASE
INTEGRAL BASE
4T
P
0•
air
0•
023
0.1,
Sr
4S
0'
42'
0"
0.19
am
51
r
40•
0•
025
7T
6'
a'
m•
IT
0.35
M.�4
IT'
1T
7T
1T
0.399F
W
1T
M'
1T
039
NOTES
1. No steps are required when height is V or less.
2. The bottom of the precast catch basin may be sloped to facilitate cleaning.
3. The rectangular frame and grate must be installed with the flange down.
The frame may be Cast into the adjustment section.
4. Knockouts shall have a wall thickness of 2" minimum to 2.5' maximum. Provide
a 1.5" minimum gap between the knockout wall and the outside of the pipe. After
the pipe is installed, fill the gap with joint mortar in accordance with Standard
Specification 9-04.3.
5 All rode Tin s risers and Castro s shall be set in mortar in accordance with
PIPE ALLOWANCES
CATCH
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
BASIN
DIM.ETE72
CGHCRET
ALL
METAL
CPSSP
SOLID
WALL
PVC(D
PROFILE
WALL
Pvc
MIT
W
30'
24'
2T
30"
Sr
30'
SIT
30"
27'
36"
sw
air
4T
30'
36'
42'
7T
4T
51
4T
36'
48"
or
54•
6P
59•
36'
48"
Sir
OP
77
.1
36
48"
9 9 g
Standard Specification 9-04.3. CMRM+� Polyethylene,1S- Sewer Pipe IBre. SPA. 9-11,20)
(9Mec . Sp
(SW Spec 9,0512(2))
Al•{Y O �� DEPAR
PUBLIC WORKS CATCH BASIN TYPE 2 STD. PLAN - 201.00
TMENT
N� MARCH 2O08
CB TYPE 2
NTS
wi BARS tili T SPACING
20'z,
24'DIAM., 4B"DIAM,
OR B4" DIAM. HOLE
1
1' MIN.
HIT MAX
SC or SS" FLAT SLAB TOP
Rf BARS O W SPLICING
2111' x 2C,
24" DIAM., 4W DIAM.
OR SI' DIAM. HOLE
r(TYP. TYPICAL ORIENTATION
FOR ACCESS AND STEPS
EoU U I- MIN.
21L2" MAX.
72' FLAT SLAB TOP
04 BARS 41S' SPACING
tv
20' x 24' OR
24' DIAM. HOLE I�
r)
2IMMAX. ECCENTRIC CONE SECTION
4V', 54", or SO"' FLAT SLAB TOP
12- UYP.)
a
0"
m
12"
PREFABRICATED LADDER
_bye {IIIII. I{I �1�Y�M I N�IIgIIIII
IJ IJ � i
STEP
SC
6 �S OR 12'
y <tONE #3 BAR HOOP
WONEMBARHOOPFOIli4"TWO 93 BAR HOOPS FOR 12
RECTANGULAR ADJUSTMENT SECTION CIRCULAR ADJUSTMENT SECTION
1 0 As an acceptable alternative to rebar, wire mesh having a
minimum areal 12 square inches per foot maybe used
for adjustment sections.
Y -
PUBLIC WORKS MISCELLANEOUS DETAILS FOR STD. PLAN 204.60
DEPARTMENT DRAINAGE STRUCTURES MARCH 2O08
NL
MISC. DRAINAGE STRUC. DETAILS
SHARED DRIVEWAYS
CITY COMMENTS
CITY COMMENTS
CITY COMMENTS
REVISION
O
FRAME AND VANED ORATE
SEE NOTE 4
CLEAN SURFACE AND BOTTOM AREA
PROVIDE UNIFORM CONTACT.
THE SURFACE AREA OF THE BASE SECTION MUST
BE GROUTED TO THE BOTTOM AREA OF THE
ADJUSTMENT SECTION.
BASE SECTION
NOTES
1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT
BE GROUTED TO FINAL GRATE UNTIL THE FINAL
ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR
SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN
ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS
GIVEN BY THE ENGINEER TO GROUT OR GRATING IN
PLACE IN ACCORDANCE WITH STANDARD SPECIFICATION
7-05.3.
2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE.
THE USE OF SHIMS IS PROHIBITED.
3. MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT
RINGS AND BRICKS PRIOR TO PLACEMENT.
4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS
ARE STAGGERED TO CREATE A RUNNING BOND OR Y2
BOND.
< STD. PLAN - 202.00
PUBLIC WORKS CATCH BASIN INSTALLATION
DEPARTMENT
FNTO MARCH 2O08
CATCH BASIN INSTALLATION
NTS
57SEE NliIE2 /B"R X 5/8"D DUMMY JOINT SEE NOTE
2'- 0" 2'- D" b
r
I I
1 I
I
3/8- PP.EMOLDED JOINT FILLER (TYP)EME
CURB AND GUTTER
PLAN VIEW
FACEOF CENTERL14LOF
L� OURS �..5 FR111AE 0 GRATE
IF'
6 1 2' 13'
1/2' R. MATCH
" ROADWAY
SLOPE
FRAME AND GRATE - NOT INCLUDED
/.. IN CURB AND GUTT6tB0 ITEM
TOP OF
VC
ROADWAYROADWAY1A
go
.D
E
• o
•
ADJUSTMENT SECTION - NOT INCLUDED
W CURB AND GUTTER BID IIFM
A'
CATCH BASIN - NOT INCLUDED
IN CURB AND Gull BD REM
k••
SECTION 0
/
GENERAL NOTES:
The intent of this design is to facilitate the removal
of a catch basin with minimal disturbance
of the curb.
?. The expansion Joints of the
adjacent sidewalk shall
/ I
be adjusted to be In
line with these curb
/
expansion Joints.
1C VIEW
IIS
V4
STD. PLAN - 101.1
CEMENT
CONCRETE CURB
PRO D:
PUBLIC WORKS
INSTALLATION AT
DEPARTMENT
CATCH BASINS
C a ow
AU
-
OAT(S //,- -
MISC. DRAINAGE STRUC. DETAILS
SURVEYED:
MB
3 29 17
PA
DESIGNED: MB
MB
9 09 16
PA
MB
81516
PA
°R°W"` MB
MB
7/07/16
PA
CHECKED:
PA
BY
DATE
APPR
APPROVED:
SCALE:
#3 BAR
#
FRAME AND VANED ORATE
5
V TWH1,llUOOPFORSHEIGHT
TWO#3 BAR HOOPS FOR 12' HEIGHT
RECTANGULAR ADJUSTMENT SECTION
.w,,xas IXA TOM
PRECAST BASE SECTION
#3 BAR EACH CORNER
16 MIN.
#3 BAR HOOP
SEE NOTE 1
ALTFRNATIVE PRECAST BASE SECrION
PIPE ALLOWANCES
MAXIMUM
PIPE YAlEA11LL INSIDE
DIAMETER
1✓EINPgiCED OR 12..
PINN CONOETE
AIL METAL RPE 15'
�• 1T
(STD. 6PEC.80520)
SDLID WALL PVC tY
(STD SPEC.9-05.12(1))
PR(Eap WALL PVC
EC. -12'fi Hill(STD. S
STORM SE
NOTES
1. As acceptable allernefives to the rebar shown In the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area Of 0.12 square inches per fool shall
be used with the minimum required rebar shown In the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 18". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grde to the lowest pipe Invert
shall be 5'.
4- The frame and grate maybe installed with the flange up or down. The
frame may be cast into the adjustment section.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the Inlet has been placed.
o STD. PLAN - 200.30
�A A PUBLIC WORKS CONCRETE INLET
♦. DEPARTMENT
fgAtpZ MARCH 2O08
1 N= Or HOR ZONTAALL 1D 983/1991
ONE INCH DATU M
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CONCRETE INLET
NTS
SEAL WITH AR 4000 OR APPROVED
EQUAL AND DRY SAND AFTER
PATCHING
MORTAR JOINT(S) (3/8" MIN.) SEE
NOTE 3 AND SPECIAL PROVISON
PLAN
NTS
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY DEVELOPMENT ENGINEERING
rstraka 06/20/2017 Brianne Bannwarth 06/22/2017
A
DEPTH OF CLASS "B"
ASPHALT TO BE 2" BELOW
BOTTOM OF THE UPPER
ADJUSTMENT RING OR A
MINIMUM DF 8" WHICHEVER
IS GREATER,
ADJUSTMENT RING (1" MIN.) OR
BRICKS. SEE NOTE 4.
SECTION A -A
NOTES
1. REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE 3
WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS FOUR
FEET. ADJUST CASTING FRAME TO PAVEMENT SURFACE
USING RISER RINGS OR CONCRETE BLOCKS PER STD PLAN 4
400.1.
2. REPLACE EXCAVATED MATERIAL WITH A MINIMUM OF 8' OF
CLASS'B" ASPHALT OR TO A DEPTH THAT IS 2"BELOW THE
BOTTOM OF THE UPPERADJUSTMENT RING WHICHEVER IS
GREATER OR AS APPROVED BY THE ENGINEER.
ALL JOINTS BETWEEN THE CONE, ADJUSTMENT RINGS,
BRICKS AND FRAME SHALL BE GROUTED
ADJUSTMENT OF THE FRAME TO GRADE SHALL BE
ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT
RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE
STAGGERED TO CREATE A RUNNING BOND OR 112 BOND. THE
USE OF SHIMS IS PROHIBITED.
STD. PLAN -
PUBLIC WORKS TYPICAL UTILITY COVER
DEPARTMENT WORKS
ADJUSTMENT FOR
PAVEMENT OR OVERLAY
TYPICAL UTILITY COVER ADJUSTMENT
CONSTRUCTION PERMIT SUBMITTAL
DATE:
CITY OF L I M E L I T E SHORT PLAT FIELDBOOK: �
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DRAWING NO:
Planning/Building/Public Works Dept. CML DETAILS C14
R-398014
1'-01 1'-0'-- SEE CONTRACTI
ROU PING 20"° 1) 1?pM R. (TYP.I
CURB NOT INCLUDED IN BID ITEM -
IN)
SEE RAISED EDGE " 3'S' IIW PREMOLORJ.EREG .. J•�
r-0' SIDEWALK DETAIL - THIS SHEET J.,NTF
SLLCUT :QN,
(SEECONTRACTI
SL`PES
1rz• DN) R. (rvP.l WITH RAISED EDGE
1 1sXURSNOTINNGTrN
auDEDmeIomEM-
NOR�� _
bH�.Ft6TL .. ..
F
3.e (INI PREMOLOEO ,,> FINISHED GRADE 1- IN) BELOW
JOINT FILLER - TOP OFCONCRETE SURFACE
7-C' SIDEWALK
ADJACENT TO CURB 1' D' 1' 0' MR. (SEE CONTRACT)
RnU nING Irz"t"R(IYP.)
_2.0'n 1 5%__� % CURB NOT INCLUDED IN BID rtEM -
1,
` are ItN '�
BRIDGE OR PEDESTRIAN PRNT FILLER
- WALL OR BARRIER
RAILING JOINT FILLER
ADJACENT TO CURB
BARNIER-BEE SIDEWALK (STEEP FI.L SLOPESI
COWRACT PLANS (BEE CO WRACTI WALL OR BARRIEf
J I H2- QN1 R. (TYP.I
FLUSH J I 15% CURB NOT INCLUDED IN BID ITEM- SIDEWALK
rr,ir. v. s T-t' Irr
VERTICAL WALL- 1'e'tlM) PREMOLDED
SEE DETAIL JOINT FLLLER(TYP.I •'�
ADJACENT TO CURB AND RAILING OR WALL 3T (IN) PREMOLOE0
JOINT FILLER
SIDEWALK BUFFERSTRIP
(SEE CONTRACT) fSEE NOTE1101
1a- IINI R. SIDEWALK ADJACENT TO WALL DETAIL
V (TYPA CURBNOTINCLUDEDeIBIDrTEM-
' �S.u-:i'w�5r•�:i LEVEL
112-IINI R. �7I
FINISHED GRADE 1- pN) BELOW TOP OF CONCRETE
SURFACE FOR PLATING - FLUSH IF PAVED e
ADJACENT TO BUFFER STRIP 0"� 1-RM R. ,!►•rr•'.e
BROONIC-0FINISH ' , �' •
4'WIDE SMOOTH
aA A'•u TROWELED PEFOMETER ABED EDGE DETAIL
t` • E%TEND SIDEWALK TRANSVERSE
0" JONTS TO INCLUDE RAISED EDGE
CEMENT CONCRETE CURB
,�- ICURS AND GUTTER SHOWN]
NOT INCLUDED IN BID ITEM
For NOTES see STD PLAN 104.2.
j Paved surfaces must comply with
STD PLAN 102.1 as applicable.
3IS' � 11B'T01N'
CO W RACTION JOINT
IN SIDE WALK ONLY
ee '
_ EXPANSION JOINT IN BOTH .•B �'e ?, TO'�' .•� �Br0'e
CURB AND SIDEWALK (SEE STD PIAN 101U
JOINT AND FINISH PREMOI E
JOINT FILLLERR
DETAIL
-:X) EXPANSION JOINT ©CONTRACTION JOINT
Y
PUBLIC WORKS CEMENT CONCRETE M. PLAN - 102
DEPARTMENT SIDEWALK PPRO rED:
TE
OEM. CONC. SIDEWALK
NTS
Gregg Zimmerman, Public Works Administrator
LANE LINE
MARKING 7,
8„
STANDARD VEHICLE WHEEL PATH
-
MIN.
1'-
MIN.
2" CLASS 'B'
2" SAWCUT AND REMOVE
OR GRIND, SEAL WITH
AR4000W
- 4.5'
3'
MIN.
MIN.
1' ACP CLASS*
MIN.
6" CRUSHED
SURFACING TOP
COURSE
EDGE OF PAVEMENT, -
EDGE OF CURB & GUTTER,
OR CENTER OF LANE LINE
J\
2.5'
MIN.
CRUSHED ROCK, FLOWABLE FILL
OR AS REQUIRED BY ENGINEER
*MINIMUM ACP CLASS 'E' or 'B' SHALL BE:
PRINCIPAL/MINOR/COLLECTOR ARTERIAL STREETS & INDUSTRIAL
ACCESS STREETS - 6" ACP CLASS 'E' or 'B'.
RESIDENTIAL ACCESS STREETS - 2" ACP CLASS 'E' or 'B'.
NOTE:
UPON REQUEST OF ENGINEER, NEW ROADWAY PAVEMENT
SECTION MAY BE DESIGNED USING AN APPROVED METHOD FOR TYPICAL LONGITUDINAL PATCH AND OVERLAY
DETERMINING PAVEMENT THICKNESS. FOR FLEXIBLE PAVEMENT
Gt�Y o� ADOPTED
CITY OF RENTON
..
STANDARD PLANS
LIT DATE: 02/05
02 ZOOS MODIFlED NOTES My DC
07 2004 1 MODIFlED NOTES Dcv Gz
DATE REVISION BY PPR D DWG. NAME: H032 SP PAGE: H032
PAVEMENT RESTORATION (LONGITUDINAL)
NTS
cotc,"ra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
p A CURB RAMP WIDTH 4' - 0" MIN. LANDING TO MATCH
o CURB RAMP WIDTH -• SEE CONTRACT PLANS
of w i I
LL LANDING GRADE BREAK LANDING
to GRADE BREAK SEE CONTRACT PLANS - CURB RAMP
I 4' - 0" MIN. CEMENT CONCRETE SIDEWALK -
SEE CONTRACT PLANS - I SEE NOTE 5
4'- 0" MIN. PROVIDE SMOOTH
CEMENT CONCRETE TRANSITION TO
SIDEWALK
SIDEWALK-' SEE NOTE 5 I WIDTH (TYP.) SEE CONTRACT PLANS-
2.0 I MAX. 4, _ 0"� IN.
FLARE (TYP.) 3/8" EXPANSION
JOINT (TYP.) - SEE ,
3/8" EXPANSION I CURB RAMP STANDARD PLAN F-30.10
JOINT (TYP.) - SEE
STANDARD PLAN F-30.10 GRADE V11
BREAK I TRANSITION TO SIDEWALK BUFFER, IF
GRADE BREAK PRESENT, OR TO BACK OF CURB (TYP.) -•
- _ 10.046 °'0°'E'pppp°0°° SEE CONTRACT PLANS , ,
- MAX. iiiiiiiiiiEii' •iiii 10.oMo MAX.MAX v„
CURB, OR CURB
AND GUTTER - CURB, OR CURB
SEE NOTE 4 AND GUTTER -
DETECTABLE WARNING SURFACE - SEE NOTE 4 D
SEE STANDARD PLAN F-46.10
FACE OF CURB FACE OF CURB
MEASURED PARALLEL DEPRESSED CURB AND GUTTER •-
TO CURB (TYP.) CROSSWALK SEE NOTE 4
PLAN VIEW
TYPE PERPENDICULAR A
DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F-45.10
4'- 0" MIN. 15 - 0" MAX.
SEE CONTRACT PLANS SEE NOTE 7
GRADE BREAK
2.0% MAX.
8.3% MAX.
LANDING CURB RAMP 'v
SLOPE TREATMENT -
SEE STANDARD PLAN F-30.10
SECTION O
CURB RAMP W/ WINGS
NTS
NOTES
��^ J CURB RAMP WIDTH 4'- 0" MIN.
1. Provide a Separate Curb Ramp for each marked Or unmarked crosswalk.
LANDING TO MATCH CURB RAMP
WIDTH -SEE CONTRACT PLANS
Curb Ramp location shall be placed within the width of the associated
crosswalk or as shown in the Contract Plans.
GRADE BREAK
2. Where "GRADE BREAK" is Called out, the entire length of the grade
break between the two adjacent surface planes shall be flush.
3. Do not place Gratings, Junction Boxes, Access Covers, or other appurte-
nances in front of the Curb Ramp or on any part of the Curb Ramp or
SEE CONTRACT PLANS -
Landing.
MIN. 4 - 0" MIN.
2.01d MAX.
4. See the Contract Plans for the curb design specified. See Standard Plan
BUFFER WIDTH - MATCH TO
F-10.12 for Curb. Curb and Gutter, Depressed Curb and Gutter, and
V., CURB RAMP DEPTH (TYP.)
Pedestrian Curb details.
1 ar,
5. See Standard Plan F-30.10 for Cement Concrete Sidewalk details.
\i
See Contract Plans for width and placement of sidewalk.
6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include
the adjacent Curb. Curb and Gutter, Depressed Curb and Gutter,
/
Pedestrian Curb, or Sidewalk.
CEMENT CONCRETE
PEDESTRIAN cuRe -
7. The Curb Ramp maximum running slope shall not require the ramp length
I SEE NOTE 4
to exceed 15-feet to avoid chasing the slope indefinitely when connecting
DETECTABLE WARNING SURFACE -
to steep grades. When applying the 15-foot maximum length, the running
SEE STANDARD PLAN F-45.10
slope of the Curb Ramp shall as flat as feasible.
DEPRESSED CURB AND GUTTER
8. Curb Ramp, Landing, and Flares shall receive broom finish. See
CROSSWALK
Standard Specifications 8-14.
PLAN VIEW
TYPE PERPENDICULAR B
(SHOWN WITH BUFFER) CEMENT CONCRETE
PEDESTRIAN CURB --
GRADE BREAK SEE NOTE 4
COUNTER SLOPE -
5.0% MAX.
TOP OF ROADWAY
DEPRESSED CURB AND GUTTER -
SEE STANDARD PLAN F-10.12
CEMENT CONCRETE CURB RAMP "TYPE
MIT -
ISOMETRIC VIEW
TYPE PERPENDICULAR A PAY LIMIT
IN AREAS OF NEW PAVING, INSTALL
PAVEMENT PER PAVING PLAN
EX PAVING
SUITABLE NATIVE OR
GRAVEL BORROW
COMPACTED IN 8" MAX
LIFTS TO 95% DENSITY
ON PRIVATE PROPERTY
CRUSHED SURFACING
PER WSDOT 9-03.9(3)
OR BANK RUN GRAVEL
PER WSDOT 9-03.19,
IN ROADWAYS AND
PUBLIC ROW
GRAVEL BACKFILL FOR PIPE
ZONE BEDDING PER SECTION
9-03.12 (3), OF THE WSDOT
STANDARD SPECIFICATIONS,
COMPACTED TO 95% DENSITY
6" MIN.
4" MIN.
WIDTH=1.5 x PIPE DIA +
18"MIN FOR 6" W=27"MIN 8"
W=30"MIN 12"W=36"MIN
FLEXIBLE PIPE
LEGEND
SLOPE IN EITHER DIRECTION
DETECTABLE WARNING SURFACE -
SEE STANDARD PLAN F45.10
3" R TYP. DEPRESSED CURB AND GUTTER -
SEE NOTE 4
8
CEMENT CONCRETE CURB Q P.'T RICE
AND GUTTER - SEE NOTE 4 4Q OT pASc. 8s.
n n
CURB RADIUS DETAIL O rat
ko PB
ISOMETRIC VIEW
TYPE PERPENDICULAR B PAY LIMIT
'o C'
00 ,Q 34363 �U�
s� �0ISTV,
�"ONAL ECG
$k$.
OHIZ
€m��8
PERPENDICULAR
CURB RAMP
STANDARD PLAN F-40.15-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
Pasco Bakodch M 6/20113
STATE DESIGN ENGINEER GATE
wasbin9ron Sole Department of Transportation
IN AREAS OF NEW PAVING, INSTALL
PAVEMENT PER PAVING PLAN
RESTORE
LANDSCAPE EX PAVING
%" MINUS CRUSHED ROCK -
COMPACTED TO 95% DENSITY
MINUS CRUSHED ROCK
COMPACTED TO 95% DENSITY
PAVEMENT RESTORATION (TRANSVERSE)
/I 1
NTS
6" MIN.
4" MIN.
WIDTH =1.5 x PIPE DIA +
18"MIN FOR 6" W=27"MIN 8"
W=30"MIN 12"W=36"MIN
RIGID PIPE
RESTORE
LANDSCAPE
\\
Cimils of pipe
/ ompaction
-I II
O.IS O.D. min.
]anus of pima
ompacuon Q 0.65 O.0. min.
gravel backfill Dravdetl-fllfar
for pipe bedding fountla0ons when specifietl
A. Metal and Concrete Pipe
T max
0.15 rise min.
climils of pipe
ompadlon �65 rise min.
gravel backfill9ravel backfill for
forpipebedding fountlelions when specified
B. Pipe - Arch Installation
Rigid Pipe NOTES:
1. Pipe compaction limits shown on this plan are for pipe
construction In an embankment. For pipe construction
in a trench, the horizontal limits of the pipe compaction
zone shall be the walls of the trench.
2. All steel and aluminum pipe and pipe -arches shall be
installed In accordance with design A.
3. Concrete pipe with elliptical reinforcement shall be
Installed In accordance with design A.
4. Concrete pipe, plain or with circular reinforcement, shall
be installed with design A.
5. O.D. is equal to the outside diameter of a pipe or the
outside span of pipe -arch. The dimensions shown as
O.D. with 3' maximum shall be O.D. until O.D. equals
3', at which point 3' shall be used.
" T-0" for diameters 12" through 42" and spans through
50". T-O" for diameters greater than 42" and spans
greater than 50".
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILIT
rstraka 06/20/2017Y }
DEVELOPMENT ENGINEERING
Brianne Bannwarth 06/22/2017 '
W (see note 6)
limit of pipe zone
bedding
material
for flexible
pipe I.
note 6)
m O.D.
foundation
level $
A = W min. 27" I.D. and under
6' min., over 27' I.D.
Bedding for Flexible Pipe
Flexible Pipe NOTES:
1. Provide uniform support under barrels.
2. an tamp under haunches.
3. Compact bedding material to 95% max. density; directly
over pipe, hand tamp only.
4. See "Excavation and Preparation of Trench" in sanitary
sewers section of the standard WSDOTIAPWA
specifications for trench width "W" and trenching
options. The pipe zone will he the actual trench width.
The minimum concrete width shall be 1 I.D. = 18".
5. Trench backfill shall conform to "Backfilling Sewer
Trenches" in the sanitary sewers section of the
WSDOT/APWA standard specifications, except that
rocks or lumps larger than 1" per fool of pipe diameter
shall not be used in the backfill material.
6. See "Bedding Material for Flexible Pipe" In aggregates
section of the WSDOTIAPWA standard specifications
for the material specifications.
ILLLLd Backfill material placed in 0.5' loose layers and
compacted to 95% maximum density.
EMMethod B or C compaction (WSDOT/APWA)
standard specifications.)
Pipe
Size
Min. dist.
between
barrels
circular pipe
cone., LCPE, CMP
(diameter)
12" to 24"
12"
30" to 96"
diam. / 2
102" to 180"
48"
pipe - arch
metal only
(span)
18" to 36"
1 12"
43" to 142"
span / 3
148" to 199"
48"
Y
STD. PLAN - 220.00
A� PUBLIC WORKS PIPE COMPACTION
p�R$ DEPARTMENT DESIGN AND BACKFILL
�'NTO MARCH 2O08
5 TYPICAL TRENCH SECTION /6-N PIPE COMPACTION AND BACKFILL
C13 NTS C13 NTS
CONSTRUCTION PERMIT SUBMITTAL
SURVEYED: SCALE. VERTDATE:
a_ f HORIZONTAL NAD 1983/1991 q 3/29/ 17
DESIGNED:
7 SHARED DRIVEWAYS Me 3 29 17 PA MB _ 1 O •• CITY OF L I M E L I T E SHORT PLAT
FlELDBOOK:
6 CITY COMMENTS MB 9 os 16 PA RENTON 16204 114TH AVE SE, RENTON, WA 98055 ML PAGE:
5 CITY COMMENTS MB 8 15 16 PA °�W"' Me DRAWING NO:
4 CITY COMMENTS MB 7 07 16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE Planning/Building/Public Works Dept. CML DETAILS C13
IF NOT ONE INCH
NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY SHEET: OF:
R-398013
E
a
LCJ
N
TO
r`
`o
CT)
N
CI
0
E
CE
cy
(n
J
0
J
U
o_
U
I
q-
In
0
N
kD
o
cn
N
CD
O
i
c
0
0
U
N
O
o_
w
C)
0
U
17
DRIVEWAYS SHALL BE PAVED TO THE EDGE
OF R-C-W PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO AVOID
EX1SA"AGPOPO
/
DAMAGING OF THE ROADWAY
IT IS RECOMMENDED THAT THE
R = 25' MIN.
ENTRANCE BE CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
moo.
y2
INSTALL DRIVEWAY CULVERT IF THERE
IS A ROADSIDE DITCH PRESENT, AS
PER CITY ROAD STANDARDS
4"-8- QUARRY SPALLS
GEOTEXTILE
sy
12' MIN. THICKNESS PROVIDE FULL WIDTH OF
NOTES INGRESS/EGRESS AREA
1. CONDITION OF USE
1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON
PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE.
GRAB TENSILE STREBNGTH(ASTM D4751)
1200 PSI MIN.
GRABTENSILEELONGATION(ASTM D4632)
30%MAX.
MULLEN BURST STRENGTH (ASTM D3786-80A
400 PSI MIN.
AOS (ASTM D4751)
20-45 (U.S. STANDARD SIEVE SIZE)
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED
FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY
AT ANYTIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO
PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY
INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE
STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE
ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH
CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY
SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET,
EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A
SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND
DISCHARGED APPROPRIATELY.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE
INSTALLED TO CONTROL TRAFFIC.
e
PUBLIC WORKS STABILIZED STD• PLAN - 215.10
DEPARTMENT CONSTRUCTION ENTRANCE
MARCH 2O08
STABILIZED CONSTRUCTION ENTRANCE
5' MAX.
DRAINAGE GRATE
GRATE FRAME
3
4 d
� D
SEDIMENT AND DEBRIS -�
OVERFLOW BYPASS
• b "„7;:'•` o P BELOW INLET GRATE DEVICE
FILTERED
WATER
° p d
p p
SECTION V IE W
DRAINAGE GRATE
- REC'
ISOMETRIC VIEW
NOTES
1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service.
2. The BIGD shall have a built -In high -Flow relief system (overflow bypass).
3. The retrieval system must allow removal of the BIGD without spilling the collected material.
4. Perform maintenance In accordance with Standard Specification 8-01.3(15).
EM (TYP.)
Y
*� + PUBLIC WORKS CATCH BASIN FILTER STD. PLAN - 216.30
`8 DEPARTMENT
�d'AiTO� MARCH 2O08
CATCH BASIN PROTECTION
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
EQUIVALENT TO ATTACH FABRIC TO POSTS.
POST SPACING MAY BE INCREASED
TO 8' IF WIRE BACKING IS USED
2"I2" BY 14 Ga. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC
BACKFILL TRENCH WITH
NATIVE SOIL
2"X4• WOOD POSTS, STEEL FENCE
POSTS, REBAR, OR EQUIVALENT
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
30-100 SIEVE SIZE IDrAD.15MM) FOR SILT FILM
ADS (ASTM D4]51)
'0 RXIS1EVE SIZE 10.30O.15MM) FOR OTHER FABRICS
WATER PERMITTIVITY ASTM D4911
0.025EC^-1 MINIMUM
GRAB TENSILE STRENCHT(ASTM D4632)
180 LBS. MIN. FOR EXTRA 5TRENGH FABRIC
300 LBS. MIN. FOR STANDARD STRENGHT FABRIC
GRAB TENSILE ELONGATION(ASTM D4632)130%MAX.
ULTRAVIOIATE RESISTANCE (ASTMD4355)170%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNEL17ATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
Y
pt� O n
+ + PUBLIC WORKS SILT FENCE STD. PLAN - 214.00
DEPARTMENT
�FN.fO� MARCH 2O08
FILTER FABRIC FENCE
NTS C12 NTS C12 NTS
-� FACE OF CURB 6" CEMENTCONCRETE
11T R. 1"R. - SIDEWALK RAMP
6t/2 VARIES _ I OR LANDING
51/2" 1" FROM T
6- TO D
TOP OF
i(' ° • n
° Fcl� ROADWAY - JOINT FILLER
D
12' R. / JOINT FILLER
CEMENT CONCRETE
PEDESTRIAN CURB
° AT SIDEWALK RAMPS AND LANDINGS
1,-6"
FACE OF ADJACENT CURB
CEMENT CONCRETE 6112" -'
TRAFFIC CURB AND GUTTER SEE DEPRESSED CURB DETAIL THIS SHEET
' _r FACE OF ADJACENT CURB 1:24
TOP OF
6 112_ .'
- FLUSH WITH GUTTER �- �1" 12"R. ROADWAY
�- PAN AT SIDEWALK 2"
RAMP ENTRANCE D
1:12 / - 1:24 °
TOP OF ° D
112• R./ ROADWAY
DEPRESSED CURB SECTION
• ° DP "I AT RESIDENTIAL DRIVEWAYS ONLY.
ICI \\!l FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 1042
DEPRESSED CURB SECTION FACE OF CURB
AT SIDEWALK RAMPS
611T
5 112' L 1"
112"R. 1"R.
FACE OF ADJACENT CURB T TOP OF
o ROADWAY
GUTTER SURFACE
_L- •
D B 114" I
1" R. D , CEMENT CONCRETE
° ' '• TRAFFIC CURB
• D
DEPRESSED CURB DETAIL
AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS
GENERAL NOTES:
1. See standard plans 102 and 101.1 for curb expansion and Contraction joint spacing.
2. Not used.
3. For Depressed Monolithic Driveway Curb 8 Gutter Section, see Standard Plan 104.2
PUBLIC WORKS STD. PLAN 101 -
DEPARTMENT CEMENT CONCRETE CURBS PR 'ED
F1VT0 It
',A*
CURB AND GUTTER DETAILS
NTS
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
7 n' AAINI .._... _..__
EXIS IING ASPHP
PAVEMENT
SAWCUT
(SEE NOTE 2)
R
7" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
RESIDENTIAL STREET MINIMUM
4" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
NOTES:
1. MUST MATCH EXISTING THICKNESS IF GREATER,
2. SAWCUT SHALL BE POSITIONED 1' - 0" BEYOND EDGE OF
DAMAGED PAVEMENT.
3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT
PLACEMENT AT THE GUTTER FACE. SEE STANDARD PLAN
FOR CEMENT CONCRETE CURBS.
STD. PLAN - 103
* PUBLIC WORKS CURB AND GUTTER PPRO D:
DEPARTMENT REPLACEMENT DETAIL y
ATE
CURB AND GUTTER DETAIL
KITC
7 SHARED DRIVEWAYS
6 CITY COMMENTS
5 CITY COMMENTS
4 CITY COMMENTS
NO. REVISION
STREET/CONTROL
L
30,
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY DEVELOPMENT ENGINEERING
PROP. rstraka 06/20/2017 0 Brianne Bannwarth 06/22/2017 0
ROW
13' 8.5' 5' 3.5'
STREET PLANTER SIDEWALK
TOP OF CURB
(PROFILE POINT)
EXISTING GRADE (TYP)
2.0%
4 3
ASPHALT PATCH 5" PERVIOUS CONCRETE SIDEWALK
C15 C15
4 CURB AND GUTTER PER 8" TOPSOIL, HYDROSEED OR SOD
C 1 COR STDS
BE 162ND ST TYPICAL ROADWAY SECTION
J NTS
STREET/CONTROL PROP.
CL ROW
1 30' 1
13' 8.5' 5' 3.5'
STREET PLANTER SIDEWALK
TOP OF CURB
(PROFILE POINT)
EXISTING GRADE (TYP) 2 0%
111III111 lllii
4 ASPHALT PATCH 5" PERVIOUS CONCRETE SIDEWALK 3
C15 C15
4 CURB AND GUTTER PER 8" TOPSOIL, HYDROSEED OR SOD
C 1 COR STDS
114TH AVE SE TYPICAL ROADWAY SECTION
NTS
BIDITEIA RAxUDESSIDEWADIRA!
e wN
-FRE.ISEE NOTE TI 6 I,
MEN
V
CO DCTK`I` ff ,
SEE NOTE CENENTCONcgETE
R1r.1P WIiN laity
SLOPE (IYP.)
B CUF GU F
ISEE NOTE 11
YB' CONTRACTION 10w (M.)
(SEE STD. PL ui
uul PLAN VIEW
VAME9
'-ISEE NO'F TDI el%MAX.
SEENOTESIT ,
.I
craw c• MN
fi' M11N
CENENi CONCRETE MESToP IIWI RYPI
smEwaaK 6ECTION O ISEE Sio. vtAN t@i
\ a.amP.l
'
REPRESSED LURE d GUliER
Id!l NDR ]I
eoEWax mDw
. DIFFERENCE IN SLOPE
r.Nx -
DNVEWAY WI rNE SLOPE (SLOPE SHOWN EXAOCFMTE01
1]%
',�
-
t ia,
• DIIIVEV AY
/
Y Hw
DRIVEWAY W. RELATIVE r
° sE ON O
NE TNESLOPE fSL
SHOWNEXIGG Met
i
- CEMENT CONCRETE
CURS d GUTTER
(SEE NOTE 3)
rl
CEMEM
CONCi
.1ae uc
_ OMTN'C
ETAa Si0 PLAN tw]I
TYPE R1B -ISOMETRIC VIEW
(RESIDENTIAL WITH BUFFER)
For NOTES STD. PLAN 104.2
STD. PLAN - 104.3
a `
PUBLIC WORKS
CEMENT CONCRETE DRIVEWAY
PPP. \'FD:
DEPARTMENT
ENTRANCE -TYPE RIB
�, m � Z
NT
A-;
{SEE NOTE al
ISEE NOTE e)
ID U Of PAVED
oalvswer gEouweo
Ld'EXPANSIONIAMj!]'P4
cE
(SEE SiD. PLAN 1@I
COMCREIE
snEwux
iBEE
NCtE s
e
m
=
Gregg Zimmerman, Public Works Administrator
y..¢„�\ \ ~•�' \�`�� CEMENT CONCRETE
`- CURB 8 GUTTER
J / (SEE NOTE 3)
CEMENT / % DEPRESSED MONOLITHIC
CONCRETE -,
SIDEWALK
CURB AGUTTER
(BEE DETAIL THIS SHEET)
�`
• w4%�
TYPE C2B - ISOMETRIC VIEW
(COMMERCAAt, WITH BUFFER)
NOTES
1. When a driveway width exceeds 15 feet, construct a full dep'J)
expansion Joint with 3/8' Joint filler along the driveway lane lines
FACEGFICURB
(see aid, plan 102). Construct expansion joints parallel with Lite
�© a1¢ own DEPRESSEDHIS HCURB DETAIL
centedlne as required at 15' maximum spacing when driveway
COKTRACTtON JOINT
STO PUN 102
widths exceed 30',
a� r ,
b 1lrR TaPaF
/ ROADWAY
2. See std. plan 102 for sidewalk details,
-� a
jL
3. Curb and gutter shown, other curb designs may be specified.
,j�
%" '• '
See std. plan 101 for curb details.
4. Not used.
�-
1'-Ir
5. The engineer will design all driveways to Include elevations at all
NOTE: DRIVEWAY LONcrruDINAL!!oANSION
points marked with symbol "X". All elevations Bra at the back of
JDINTB stvu BE FUC=RB H
DEPRESSED MONOLITHIC CUI� &GUTTER DETAIL
curb top on uphill side
6. Not used.
7. For Driveway Widths sea DRIVEWAY STANDARDS
(See NOTE 10). The expansion joints (see std. plan 102) shall be
spaced as shown In the corresponding Isamelrlc view.
8. Slopes shall Comply with seCSlons R303.2.1 Or R303.2.2 Or
- FACE OF ADJACENT CURB
R303.2.3 of the Revised Draft Guidelines for Accessible Public
Rights November 23, 2005
\ 1"
-of -Way of (PROWAO).
9. Curb reWme for any Type C-MAX Driveway may be approved on
a case -by -case basis.
', yo fit. R ACE
10. STREET STANDARDS = Renton Municipal Code (RMC)
Title IV Development Regulations
CHAPTER 5 STREET AND UTILITY STANDARDS
Section 4-6-060 STREET STAN DARDS
DEPRESSED CURB DETAIL
AT RESIDENTIAL ORCOMhERCULL DRIVEWAYS, AND ALLEYS
DRIVEWAY STANDARDS = Renton Municipal Code (RMC)
Title IV Development Regulations
_
Driveway Example: TYPE C1B
CHAPTER 4
R=Resldensd, C--Gomm cw
CITY-WIDE PROPERTY DEVELOPMENT STANDARDS
1}
Number of Laren,
Section 4-4-080 PARKING, LOADING AND DRIVEWAY
(MAx=4 Lane Commerrtaq
REGULATIONS
B-Bufter(Renting Strip), Blank-NoSuffw
PUBLIC WORKS
CEMENT CONCRETE DRIVEWAY
D - 104az
R 'V
DEPARTMENT
ENTRANCES - NOTES AND DETAILS
Arr
s DRIVEWAY DETAILS
C12 NTS
SURVEYED: SCALE: CONSTRUCTION PERMIT SUBMITTAL ��
w� f HORIZONTAL-TICAINAD 1983/1991 4► 3/29/17
MB 3 29 17 PA DESIGNED: 10•� CITY OF L I M E L I T E SHORT PLAT FIELDBOOK:
MB 9 09 16 PA MB RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
MB 8 15 16 PA DRAWN:
MB DRAWING N0:
MB 7 07 16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE Planning/Building/Public Works Dept. CML DETAILS C1
If NOT ONE INCH
BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: OR
R-398012
R-39801 1
CONTRACTOR SHALL COMPLY WITH THE CITY OF
RENTON'S TRENCH RESTORATION AND STREET
N
N
N
OVERLAY REQUIREMENTS. ROW LINE (TYP) - n W W W
II_ FILL AREA GRADE
' O TO DRAIN CB 3 CB #2
1 FILL AREA GRADE
TO DRAIN
12" SID
— �•— — —�` 12" SD
' M /`1
- REMOVE EX 12" CULVERT
SAWCUT LINE
I
1550 — 25+00 RESTORE EX SURFACES (TYP)
25+50
1 — — 26+00
SS SS SS SS SS
WI
WI
=1 �
(A 1
W0
'W^^ d
�CIS�Q�Z� S
1 U
z �
1 cD
Iw 0
1 N ��cnCD
n
W
7
Psi
CB #1
REMOVE EX INLET
RIM 472.59
-- IE 12" CPEP N 470.26
- IE 12" CPEP E 470.24
-i
IE 12" CPEP W 469.84
I I
I q
I
I
_ I 26+50 26+56
I
I 1
I
I 1
I of
Ic
I Ni I
- RESTORE PAVEMENT
MARKINGS (TYP)
I 1
I 1 �
I 1
1
I 1
I I
� 1 I
1 CONNECT TO EX CB
I
L !J
24+50 25+00 25+50 26+00 SE 164TH ST STORM PROFILE 26+50
Know what's below.
Call before you dig.
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraeng i neeri ng.com
114TH AVE SE PROFILE
SCALE: HORZ. 1 " = 10' VERT. 1 " = 5'
SURVEYED:
SCALE:
7
SHARED DRIVEWAYS
MB
3 29 17
PA
DESIGNED: MB
6
CITY COMMENTS
MB
9 09 16
PA
5
CITY COMMENTS
MB
8 15 16
PA
DRAWN: MB
4
CIIY COMMENTS
MB
7/07/16
PA
CHECKED:
PA
I
NO.
REVISION
BY
DATE
APPR
APPROVED:
U
b
U�
_z
0 O
J r___
� II
W
C;E
ErV
470
475
470
LEGEND
1
CB TYPE-1 C14
CB TYPE-2 48"
STORM DRAIN MAIN
SANITARY SEWER MAIN
SANITARY SERVICE LINE
— WATER SERVICE LINE
WATER/FIRE MAIN
FIRE HYDRANT
Q CONIC THRUST
BLOCKING HORIZ
WATER TEE
Im WATER METER 1
SS3
NOTES
1. SEE SHEET C1, C2 & C12 FOR GENERAL NOTES AND ROADWAY DETAILS.
2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C13.
3. SEE SHEET C11 FOR ROADWAY SECTIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE
PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS
AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT
COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BEYOND
THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF
THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL
EXISTING INFORMATION AND TO FURTHER DISCOVER AND AVOID ANY OTHER
UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE
AFFECTED BY THE IMPLEMENTATION OF THESE PLANS.
5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND
ASSUMED CONFIGURATION. THE CONTRACTOR SHALL UNCOVER ALL PIPING
WHERE CROSSING, INTERFERENCES, OR CONNECTIONS OCCUR PRIOR TO
TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE
ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE THE
APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL
ADJUST WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED
CLEARANCES.
6. COORDINATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACCESS
IS MAINTAINED AS REQUIRED.
7. PROTECT UTILITIES TO REMAIN.
8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO
CURRENT CITY OF RENTON STANDARDS.
9. THE DITCH AREA WILL BE RE -GRADED TO ALLOW THE CATCH BASINS TO
COLLECT FROM FROM THE ROADWAY AND THE ADJACENT PRIVATE
PROPERTY AND WILL BE PLANTED WITH GRASS. EDGE OF PAVEMENT TO THE
EXISTING DITCH LINE SHALL BE AT A SLOPE OF 6:1. MAX.
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY } DEVELOPMENT ENGINEERING 0,44
rstraka 06/20/2017 ir Brianne Bannwarth 06/22/2017
CONSTRUCTION PERMIT SUBMITTAL
DATE:
1988
1 "_ 10, HOR ZONTAL: NAD D1983/1991 CITY OF L I M E L I T E SHORT PLAT 3/29/ 17
FIELDBOOK:
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
ONE INCH DATU M DRAWING NO:
AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH FRONTAGE IMPROVEMENTS 114TH AVE SE C10
SCALE ACCORDINGLY
SHEET: OF:
R-39801 0
Hills]
475
swe
W
E.1
1 CONTRACTOR SHALL COMPLY WITH THE CITY OF
RENTON'S TRENCH RESTORATION AND STREET
1 OVERLAY REQUIREMENTS.
1
PROTECT EX WATER--
1
REMOVE EX 12 CB4
CULVERT
1p'��.;:..�iai .���u��'°��.[..��:. 12" SD
O RESTORE EX
1 SURFACES U �fRESTORE EX
1 FILL AND GRADE TO - M M SURFACES (TYP) -M -
W 1 DRAIN 3 SAWCUT LINE
Wi
_ - 22+50 i 23+00 I FILL AND GRADE TO
�- - 23+50 DRAIN
1 -
W 24+00
iJ S
W i SS SS SS —ISS �
3
1 3 Ln
i— QSO �
CIS (IS CIS QS QS
1 CIS —
-u —u3 lip
1
1 =�(J� �Ln 3 i=
(J�
1 B OO q 06 (J \
i II II
00 >< z N L N N
ftt Q7=
SS
W
ROW LINE (TYP)
1
i
SS —
1
1
'-►F -- -- -- --
1
1
-1
i
PROTECT EX WATER
1
1
FILL AND GRADE TO
m
DRAIN
- m
REMOVE EX 12"
CULVERT
2244��I
_
U
F-
U
OO
w
n-
U
N
z
cn
W
U
n,
n
n
n
coterra
ENGINEERING PLLC
Know what's below. 321 3rd Ave South, Suite 307
Call before you dig. Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
114TH AVE SE PROFILE
SCALE: HORZ. 1 " = 10' VERT. 1 " = 5'
7 SHARED DRIVEWAYS
6 CITY COMMENTS
5 CITY COMMENTS
4 CITY COMMENTS
NO. REVISION
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY0=.BriannLeoBannwarth
rstraka 06/20/2017
MENT ENGINEERING
06/22/2017
I
I SURVEYED:
MB
3 29 17
PA
DESIGNED: MB
MB
9 09 16
PA
MB
8 15 16
PA
DRAWN: MB
MB
7/07/16
PA
CHECKED:
PA
BY
DATE
APPR
I APPROVED:
I
im
- A
1-6
10
1
1
1
1
1
1
1
1
1
-i
1
1
NOTES
1. SEE SHEET C1, C2 & C12 FOR GENERAL NOTES AND ROADWAY DETAILS.
2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C13.
3. SEE SHEET C11 FOR ROADWAY SECTIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE
PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS
AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT
COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BEYOND
THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF
THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL
EXISTING INFORMATION AND TO FURTHER DISCOVER AND AVOID ANY OTHER
UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE
AFFECTED BY THE IMPLEMENTATION OF THESE PLANS.
5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND
ASSUMED CONFIGURATION. THE CONTRACTOR SHALL UNCOVER ALL PIPING
WHERE CROSSING, INTERFERENCES, OR CONNECTIONS OCCUR PRIOR TO
TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE
ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE TH
APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL
ADJUST WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED
CLEARANCES.
6. COORDINATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACCESS
IS MAINTAINED AS REQUIRED.
7. PROTECT UTILITIES TO REMAIN.
8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO
CURRENT CITY OF RENTON STANDARDS.
9. THE DITCH AREA WILL BE RE -GRADED TO ALLOW THE CATCH BASINS TO
COLLECT FROM FROM THE ROADWAY AND THE ADJACENT PRIVATE
PROPERTY AND WILL BE PLANTED WITH GRASS. EDGE OF PAVEMENT TO THI
EXISTING DITCH LINE SHALL BE AT A SLOPE OF 6:1. MAX.
U-1141
475
LEGEND
1
CB TYPE-1 C 14
CB TYPE-2 48" 2
STORM DRAIN MAIN
SANITARY SEWER MAIN
SANITARY SERVICE LINE
— — WATER SERVICE LINE
WATER/FIRE MAIN
470 )111111, FIRE HYDRANT
a CONIC THRUST
BLOCKING HORIZ
465 WATER TEE
WATER METER 1
SS3
460
ASPHALT CONIC
PAVEMENT
CEM. CONC.
PAVEMENT
PERVIOUS 3
CONCRETE C 15
SIDEWALK
CONSTRUCTION PERMIT SUBMITTAL
SCALE:
VERTICL: 1988
1 �_ 10, HOR ZONTAL: NAD NAVD1983/1991 CITY OF L I M E L I T E SHORT PLAT 3/29/ 17
FIELDBOOK:
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DRAWING NO:
ONE INCH DATU M
AT FULL SCALE Planning/Building/Public Works Dept. FRONTAGE IMPROVEMENTS 114TH AVE SE C9
IF NOT ONE INCH
SCALE ACCORDINGLY
SHEEP: OF:
R-398009
Z
N
(0
T
W
co
M -
S1° 31 39.44„W!I
114TH AVE SE
STA +00 = SE 162ND STA 10+00
CONIC MONUMENT W/ BRASS -
N 170084.65 9 -
E 1305087.02 °
a
a a
°
J Jj
�r-9z�0)
Cn Oj O
ZNN �I�
° O o O
=1
c�i�CDC-O �z00z
° Q
ill
Q STA 21 +51.68, 13.00' LT
m L 16 IDE DRIVEWAY
z0-) SEE SHEET C5 FOR
O ( ONSITE UTILITY PLANS
W O I� O
U� N �0 1 LINE (TYP)
J 1
RIQIECT EX UTILITY POLE �
4' WIDE ACP LANDING 1
SLOPE AT 2.0% MAX
ACP RAMP, SLOPE AT 12• -T
MAX, MATCH EX GRADE
\ CB #5 1
3 1
„ D
0 00
E- Ir2�-e�m ! m
_ !m
j FILL AND GRADE TO DRAIN !
ELEC CABINET, !
I SEE LIGHTING PLANS
1
�2+00#6 i rn
m
STA 21 +79.12, 13.00' LT
END CURB AND GUTTER AND PROJECT SIDEWALK
STArr'k1f77.12. 42.24' LT
1
1
1
1
1
1
J
m
'
.......... _
N
......
Lin
1
. . . . . . . . . . CV
cV
W
CV
�_
485
..........,.
.......... ; p w
.......
c w ...... a'
w
w
o
. . . . . .
..EX CENTERLINE
i
�� L
+ p�
o��___ _r
+ C68+
rnp a;
060-) r-
�p
rn
cflr7
GRADE
!
p. 00 00 �
a
EX GRADE AT ROADWAY
N co s N
¢ Q
� 4 � +
w N
�
+ m
N c�
� �
CO�
REMOVE EX 12"1
1
c~i� U iY !�'
CENTERLINE
PROPOSED
TOP
OF CURB ELEVATION
cn m i� LEI 00
z E w
�
CULVERT
Ln
w
1.
480
............
...............
1
FILL AND GRADE
-
1
-
.
-030%
��
TO DRAIN
45 LF 12" DI SD 1.0%
Q
EX
- - ...........
- ....
-
�q�
.:
- -
- -
i m
O
.............................................................
6"SS, FIELD VERIFY ELEVATION
......�.
.....
... .....
.. ........'
rn
......
. .................
PRIOR TO CONSTRUCTION
� .. �:..-.- ._
—
14 LF �,
— ------
1(A
475
...
.-
• %
L12
FIELD VERIFY ELEVATION OF EX 8"
I ..........
1 ITI
WATER MAIN PRIOR TO CONSTRUCTION
I
m
TO ENSURE 6" CLEARANCE FROM
470
PROPOSED 12" SD, NOTIFY ENGINEER
OF POTENTIAL CONFLICTS
EX 6" SS, FIELD VERIFY ELEVATION ...
..
1
-
o
PRIOR TO CONSTRUCTION
0
-
U
o
p
W
SAME STRUCTURE CB
6
1
cn
z
�-'
SAME STRUCTURE CB #5
1
465
�
�,
p
,�
O
475
1
�w
a_
1
g1
-
+mo,�
N C.�
1.
460
00
470
15 LF 12''
L" � �
w
SD 2.00% O
i
STA 21 +93.00, 17.5' LT
1
48" CB #6 TYPE 2 W/ SOLID LID
!
455
RIM 479.15
1
IE 473.73(N), 469.93(SE), 476.55(8" NE)
1
M0)
C�o
OOr?CR
co
1`-�N!n
C�o co
CO
Lnpr
00
LgpcV
00
m
00
m
00 m
00 m
06 O
00 ai
450
���
mF-m
���
mom
c)��
mom
���
mom
���
mom
���
mom
20+00
20+50
21+00
21+50
22+00
Know what's below.
Call before you dig.
co.:,erra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
114TH AVE SE PROFILE
SCALE: HORZ. 1 " = 10' VERT. 1 " = 5'
7 SHARED DRIVEWAYS
6 CITY COMMENTS
5 CITY COMMENTS
4 CITY COMMENTS
NO. REVISION
SURVEYED:
MB
3 29 17
PA
DESIGNED:
MB
MB
9 09 16
PA
MB
8 15 16
PA
DRAWN: MB
MB
7 07 16
PA
CHECKED:
PA
BY
I DATE
I AP P R
APPROVED:
SCALE:
1 a_ 10,
HORIZONTAL: N D 11983/1991
ONE INCH DATUM
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
Egm
2N
475
NOTES
1. SEE SHEET C1, C2 & C12 FOR GENERAL NOTES AND ROADWAY DETAILS.
2. TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C13.
3. SEE SHEET C11 FOR ROADWAY SECTIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE
PLANS HAVE BEEN DERIVED FROM FIELD SURVEY PREPARED BY OTHERS
AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT
COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS BEYOND
THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF
THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL
EXISTING INFORMATION AND TO FURTHER DISCOVER AND AVOID ANY OTHER
UTILITIES AND SURFACE FEATURES NOT SHOWN HEREIN WHICH MAY BE
AFFECTED BY THE IMPLEMENTATION OF THESE PLANS.
5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND
ASSUMED CONFIGURATION. THE CONTRACTOR SHALL UNCOVER ALL PIPING
WHERE CROSSING, INTERFERENCES, OR CONNECTIONS OCCUR PRIOR TO
TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE
ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE THE
APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL
ADJUST WATER LINE ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED
CLEARANCES.
6. COORDINATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACCESS
IS MAINTAINED AS REQUIRED.
7. PROTECT UTILITIES TO REMAIN.
8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO
CURRENT CITY OF RENTON STANDARDS.
9. THE DITCH AREA WILL BE RE -GRADED TO ALLOW THE CATCH BASINS TO
COLLECT FROM FROM THE ROADWAY AND THE ADJACENT PRIVATE
PROPERTY AND WILL BE PLANTED WITH GRASS. EDGE OF PAVEMENT TO THE
EXISTING DITCH LINE SHALL BE AT A SLOPE OF 6: 1. MAX.
LEGEND
-- 1
CB TYPE-1 C14
\� CB TYPE-2 48" C 14
- - - - - - - STORM DRAIN MAIN
SANITARY SEWER MAIN
SANITARY SERVICE LINE
— WATER SERVICE LINE
WATER/FIRE MAIN
ASPHALT CONIC
PAVEMENT
470
CEM. CONC.
PAVEMENT
465
PERVIOUS 3
CONCRETE C 15
460 SIDEWALK
455
- - - - - - - - SAWCUT LINE
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY
DEVELOPMENT ENGINEERINGn,77
rstraka 06/20/2017 'rianne
B Bannwarth 06/22/2017
CONSTRUCTION PERMIT SUBMITTAL
DATE: n
�% CITY OF L I M E L I T E SHORT PLAT FlELD3/29/17
IMU
REN TON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
Planning/Building/Public Works Dept. DRAWING NO:
FRONTAGE IMPROVEMENTS 114TH AVE SE
R-398008
R-398007
CL
Ln
0
L
0
N
N
0
E
0
3
Z
n
d
0
z
N
(L
(o
U
(L
(n
0
z
N
C
0
c,
N
co
Lj
E
o
o
0
U
.o
a
0
N
o
0
T
o
E
o
U
/
w
w
o-
w
O
U
ai
i�
CONTRACTOR SHALL COMPLY WITH THE CITY OF
RENTON'S TRENCH RESTORATION AND STREET
P K NAIL OVERLAY REQUIREMENTS.
O
O
SE 162ND ST STA 10+00 - W W—--
W
i
CONC MONUMENT W/ BRASS DISC
A
N 170084.65 � c"
E 1305087.02 (C12 SE 162ND ST SEE SOOS CREEK SEWER MAIN _ _ - +
o
8 _ _
» m PLANS FOR SANITARY SEWE,R4 ) c�
S88° 29 38 90 E 10+50 �
11 +00 IMPROVEMENTS- (TO) w
- 1 i i Cn r,
cl,
m
0
.i
CT
Cl)
N
O
480
S
EIFA
L LJ
a
c�
0
LJ
z
. .
N O
N \ O
cN0 + 00
CD CD
EX TOP OF CURB ELEVATION II
Cfl a PROPOSED TOP OF CURB ELEVATION
II + o I�ail
O �00� Q -1��.� w
U-1
vFrw F 1 1.46%
SEE SHEET C8 FOR SD PROFILE
470
ED&
1.79%
174 LF 12" SD 1.5%
EX GRADE AT ROADWAY CENTERLINE
O
CD
Cp
co r)
r'
cq 7:
r-C-4
Ln
N�0
LC)
. Cy)
�r`
00-
O�-
N
njN
njN
00
00
00
0000
Do 00
00
0000
00
00 00
U
U3:
U
C U
U
U 3::
U
C. U
U
U
mF-
m
mF-
m
mF-
m
mF-
m
mF-
m
10+50
CURB RETURN TABLE
NO.
A
R
STA PC LOCATION
TOP OF CURB ELEVATION
STA PT LOCATION
PC
1 4
1 2
3 4
PT
O
89°58'41.7"
25'
10+12.99, 37.99' RT
479.55
480.14
480.09
480.57
480.74
10+37.99, 13.00' RT
Know what's below.
Call before you dig.
co. :)rra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
11+00 11+50
SE 162ND ST PROFILE
SCALE: HORZ. 1 " = 10' VERT. 1 " = 5'
NOTES
U X
�- Lil
(n ck�
o Uj
o �Q
ow LEI-�^
U_
Z 0_
-J LLJ Uij
�w
Qw
U U) Uj Z
1-
of
W of Q p U U
IY
ZIw-'�CD
00
o¢� CD N
O
a
U � •� U N
+
Lil 2
�oo
� U
10w
1-5
`n - a- 12+00
O
O
CD
00
I I
cn
' 482.97
482.90f(E)�
O
m
N
00
I I
LLJ
LLI
Q
. .
.
(D
0
LJ
�L
z
Un
L
o
r7.
�.
LLJ
+
+
0_ -
.N c,
N
�.
II
. . N
O .00 CD
m .�
F
w.
(n
Uor_ W
483.43t(E)
SS
&
SS
t? ,I0' RT
E/ C.AND GU7ER
RA E 21 MAX —
M X PITCH
-GRADES I
1
74'X5'X12" THICK RIP RAP
ACP P, SLOPE AT 12:1
MARL, M TCH EX GRADE
4' WIPE ACP LANDING
LOPEI AT 2.0% MAX
� S 1 +30.31, 24M RT H E R
J E TE EWALVK�
�I
�I
J
&A!k-1
m
HI:11
Ekk
470
.
N
N CY)
— 00 Co
. .
0o Ln
I'(i
0p O CD
r'i 00
r) �
c00 00
0c) 00 00
00
00
d00
- �
�
dc-
AA-X;
mI-
m mI-
m mI-
m
1.
SEE SHEET C2 & C12 FOR GENERAL NOTES AND ROADWAY DETAILS.
2.
TYPICAL TRENCH SHALL BE PER COR STD. PLAN 220.00, DETAIL 5/C13.
3.
SEE SHEET C7 FOR ROADWAY SECTIONS.
4.
ALL LOCATIONS OF EXISTING UTILITIES AND FEATURES SHOWN ON THESE PLANS HAVE BEEN
DERIVED FROM FIELD SURVEY PREPARED BY OTHERS AND SHOULD THEREFORE BE CONSIDERED
APPROXIMATE ONLY AND NOT COMPLETE. ADDITIONAL SURFACE FEATURES AND IMPROVEMENTS
BEYOND THOSE INDICATED ARE PRESENT AND IT IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL EXISTING INFORMATION AND TO
FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES AND SURFACE FEATURES NOT SHOWN
HEREIN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THESE PLANS.
SURVEYED:
7
SHARED DRIVEWAYS
MB
3 29 17
PA
DESIGNED:
MB
6
CITY COMMENTS
MB
9 09 16
PA
5
CITY COMMENTS
M13
8 15 16
PA
DRAWN: MB
4
CITY COMMENTS
MB
7 07 16
PA
CHECKED:
PA
NO.
REVISION
BY
I DATE
APPR
APPROVED:
12+00 12+50
.----- --- --- 1
CB TYPE-1 C14
' 2
CB TYPE-2 48" C 14
- - - - - - - STORM DRAIN MAIN
SANITARY SEWER MAIN
SANITARY SERVICE LINE
— — WATER SERVICE LINE
WATER/FIRE MAIN
CURB & GUTTER 4
C1
ASPHALT CONIC 2
PAVEMENT C 15
CEM. CONC. 6
PAVEMENT C1
PERVIOUS 3
CONCRETE C 15
SIDEWALK
- - SAWCUT LINE
175 PROP. F.G. CONTOUR
N WATER VALVE
-cam PIPE OUTLET
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
5. CROSSING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATION AND ASSUMED CONFIGURATION. SURFACE WATER UTILITY DEVELOPMENT ENGINEERING
THE CONTRACTOR SHALL UNCOVER ALL PIPING WHERE CROSSING, INTERFERENCES, OR rstraka 06/20/2017
CONNECTIONS OCCUR PRIOR TO TRENCHING OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO Brianne Bannwarth 06/22/2017
DETERMINE ACTUAL LOCATIONS, SIZE, AND MATERIAL. THE CONTRACTOR SHALL MAKE THE
APPROPRIATE PROVISION FOR PROTECTION OF SAID FACILITIES AND SHALL ADJUST WATER LINE CURRENT PLANNING
ALIGNMENT AS NECESSARY TO ACHIEVE REQUIRED CLEARANCES. mdavis 06/20/2017 '
6. COORDINATE ALL WORK WITH CITY OF RENTON TO ENSURE FACILITY ACCESS IS MAINTAINED AS
REQUIRED.
7. PROTECT UTILITIES TO REMAIN.
8. ANY STREET SIGN REMOVED OR RELOCATED MUST BE BROUGHT UP TO CURRENT CITY OF
RENTON STANDARDS. CONSTRUCTION PERMIT SUBMITTAL
SCALE: DATE:
1 >a_ 10, HORIZONTAL: N D 11983/1991 CITY OF L I M E L I T E SHORT PLAT 3/29/17
FlELDBOOK:
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
A
ONE IN DATUM FRONTAGE IMPROVEMENTS DRAWING NO:
AT FULL SCALE Planning/Building/Public Works Dept. C6
IF NOT ONE INCH
SCALE ACCORDINGLY SE 162ND ST
SHEET: OF:
R-398006
REFER TO
► 1 1F4FA P
FRONTAGE
/ DOMESTIC SERVICE CONNECTION PER SOOS
CREEK STANDARD PLANS. CONFIRM METER AND
SERVICE SIZING WITH PLUMBING DESIGNER (TYP)
001 I I --! CH IYPE 1 I -- T - - FUTURE I /
1 I RIM 480.45
0 ,� _IE 477.57 _ _ — — I C NECTION I
0T)1 I�
16 LF 8" SD \ \
cnl
1 1i
I I l i7777 00 I
i I� 16"DEC CB TYPE 1 FF 83.13 NI
5' / RIM 480.36 I ✓ M
I a IE 477.25 I I
1 I I_n ,c
1 I / Q,� i SHARED UTILITYLf I
I EASEMENT (TYP)
FF= 483.07
I
RIM 479.64 rLQ f
P
E 1 i �9/ IE 476.45 _ _
— ASIN TYPE 1
CD
��VN C P STUB FOR FUTURE -- - 7 476.757
=.47�7.3 5 BLDG -CONNECTION a. — — —
1 % _(L� IE 476.81 I� a — —•—--- ——•— ---
--- -- - 51 LF 8" SD •--•--
_
N
106 1 I; — —� SD MANHOLE54"W/ Q--------------- -----
479.64 I iLOV1i CONTROL STRUCTURE UNDVATE
ERGROUND DETENTIO FACILI �I 1
PK NAIL / I 4 9.
I SYS EM C6-6 -0
-
IE 78" 469.32 (6" DEAD STORAGE _j — —
1 _._—•—"-SD _ JE_469�12"STD-- -- -- -- -- -- —
REFER TO SOOS '- IE 469.81 (36" E, IN)� �� E �E 14914.6 7
CREEK SANITARY �
1
Z SEWER PLANS 1 I \
FOR SIDE SEWER
AND SEWER 1
MAIN EXTENSION 1
Ln
PLANS -
N
Z
cn
Lf
N 1
c
o -
c -
N 1
Ld
VCD
I
1 J.
'I
c /
E 1
U
O
� I
PRO CT 1 c �"
EX UT�TY J
1_ 9�
CD —1 POLI
R M ION 0. 10CN
~j
0
JE
Know what's b@IOW.
Cal before you dig.
i.�
Q0 I \ I SHARED UTILITY
! ) o I I EASEMENT (TYP)
♦ e
k
,e
--------------
L CB TYPE 1
RIM 479.25
IE 47ffT REBAR/CAP "15025"
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
DETENTION ACCESS
i RISER (TYP)
I I 20 LF 8" SD
— — — — — — — — — — — — — — — — --
\� `1 '
1� MAT SERVICE
SWALE S88023 09"E 200.30'
35163
,�,I STER�'�
ZJSIONAL�
7 SHARED DRIVEWAYS
6 CITY COMMENTS
5 CITY COMMENTS
4 CITY COMMENTS
NO. REVISION
i'
I�
I�
I I
co
cI
0011 L"
.J
II CATCH BASIN TYPE 1
RIM 480.80
—1 7 - IE 477.77
I<
LOT 5
WATER SERVICE
(TYP)
STUB FOR
FUTURE BLDG.
CONNECTION
IE 476.39
A_.—.—<_.—.—<_.—.—<_.—.—<_
—CATCH BASIN TYPE 1 _ — —
�RIM 480.80------ \
IE 47. 7 \
LOT 5
WATER SERVICE
(TYP)
STUB FOR
FUTURE BLDG.
CONNECTION
IE 476.39
A_.—.—<_.—.—<_.—.—<_.—.—<_
—CATCH BASIN TYPE 1 _ — —
�RIM 480.80------ \
IE 47. 7 \
SURVEYED:
MB
3 29 17
PA
DESIGNED:
MB
MB
9 09 16
PA
MB
8 15 16
PA
DRAWN: MB
MB
7/07/161
PA
CHECKED:
PA
BY
DATE
I AP P R
APPROVED:
SCALE:
1 "=10,
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
FF= 481.55
PROPERTY LINE
\
I
Ln
7t
L-L 1
z
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY DEVELOPMENT ENGINEERING
rstraka 06/20/2017 ' Brianne Bannwarth 06/22/2017
CURRENT PLANNING
mdavis 06/20/2017
NOTES
1. SEE SHEET C1 AND C2 FOR GENERAL NOTES, GENERAL STORMWATER
NOTES, AND GENERAL SANITARY SEWER NOTES.
2. ALL ROOF DOWNSPOUT CONNECTIONS TO THE FUTURE BUILDING STUB
OUTS SHALL BE PERFORATED PIPE. MAINTAIN 5' MIN. SEPARATION FROM
BUILDING.
3. ALL WORK SHALL BE IN ACCORDANCE WITH CITY OF RENTON AND SOOS
CREEK SEWER AND WATER STANDARDS AND REQUIREMENTS.
4. SEE SOOS CREEK SEWER PLANS FOR SANITARY SEWER MAIN WORK AND
SIDE SEWER STUBS WITHIN THE RIGHT-OF-WAY.
5. VERIFY SIZE OF NEW WATER METER AND SERVICES WITH PLUMBING
DESIGNER AT TIME OF BUILDING PERMIT.
6. COORDINATE METER INSTALLATION WITH BUILDING PERMIT. PROVIDE 18"
MIN. COVER OVER DOMESTIC WATER SERVICE. (DOMESTIC WATER SERVICES
SHOWN FOR INFORMATION ONLY.)
LEGEND
1
CB TYPE-1 C14
DETENTION TANK MAINTENANCE ACCESS
2
CB TYPE-2 48" C 14
STORM DRAIN MAIN
STORM DRAIN SERVICE
SANITARY SEWER MAIN
SANITARY SERVICE LINE
CLEANOUT
WATER SERVICE LINE
WATER/FIRE MAIN
SWALE
1
WATER METER SS3
ASPHALT CONIC PAVEMENT 2
C15
TABLE OF DRAINAGE AREAS
TOTAL LOT
AREA
MAX IMPERV
BY ZONING
REDUCED
MAX IMPERV
REDUCTION
IN IMPERV
LOT 1
5,039
3,779
2,728
1,052
LOT 2
5,032
3,774
2,724
1,050
LOT 3
5,940
4,455
3,215
1,240
LOT 4
8,834
6,625
4,782
1,843
LOT 5
5,065
3,799
2,742
1,057
(ALL AREAS IN SF) TOTAL
FLOW CONTROL BMP
IMPERVIOUS
AREA CREDIT
1,052
1,050
785
0
1,057
3,943
SET REBAR/CAP "15025"
F_ CONSTRUCTION PERMIT SUBMITTAL
--]
DATE:
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991 CITY OF L I M E L I T E SHORT PLAT 3/29/17
FlELDBOOK:
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DATUM DRAWING N0:
Planning/Building/Public Works Dept. DRAINAGE AND UTILITY PLAN C5
SHEET: OF:
R-398005
W
co
W
Q
d'
f
r
00
0
0-)
06
-79.64
'K NAIL
rn
N
0I
0
—w _
�w wow
Q �
11 �A
M■ m
M■ 1
1___ I "-d
Om
I I 479.0E C 8 It
° 0
0
Know what's below.
N
Call before you dig.
APPLICANT SHALL COMPLY WITH CITY OF
■ / RESTORATION 1 STREET
OVERLAY REQUIREMENTS.
WE
9
I
Q
=47 = —
/ 480.30
0 (8)6,� IC
Q / /
.80
J�
=LOT
FF— 481. 55
�e
479.25
Iz
47:\7
S88°23'
09"E
200. 30' ����----------�'
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
SURVEYED:
I
7
SHARED DRIVEWAYS
MB
3 29 17
PA
DESIGNED:
MB
6
CITY COMMENTS
MB
9 09 16
PA
5
CITY COMMENTS
MB
8 15 16
PA
DRAWN: MB
4
CITY COMMENTS
MB
.7/07/161
PA
CHECKED:
PA
NO.
REVISION
BY
DATE
APPR
APPROVED:
PROPERTY LINE
483.43t(E)
482.97 483.05t(E) I/
482.90t(E) :� �l
Ln
LJ1
N
0
00
I
I
I
I
I
I
JI
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
:01
Brianne Bannwarth 06/22/2017
LEGEND
175
PROP. F.G. CONTOUR
CURB & GUTTER 4
C1
6
CEM. CONC. PAVEMENT C 1
PERVIOUS CONCRETE SIDEWALK 3
C15
rw--] ASPHALT CONC PAVEMENT 2
C15
*--- xx.xx PROPOSED F.G. ELEVATION
NOTES
1. PROPERTY AND AREA OF WORK ARE 29,912 SF.
2. FIELD VERIFY ELEVATIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES
PRIOR TO CONSTRUCTION.
3. REMOVE EXISTING FEATURES AS REQUIRED FOR CONSTRUCTION OF NEW
IMPROVEMENTS.
4. SEE SHEET C1 FOR GENERAL NOTES.
5. SEE OFF -SITE FRONTAGE IMPROVEMENT PLANS FOR STREET WORK IN
RIGHT-OF-WAY.
6. FINAL SITE PAVING & GRADES TO BE PROVIDED WITH INDIVIDUAL BUILDING
PERMIT DRAWINGS
1. ALL EARTHWORK AND SUBGRADE PREPARATION SHALL BE PERFORMED IN
ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OF THE
GEOTECHNICAL REPORT PREPARED FOR THIS PROJECT.
2. FINISH GRADE INDICATED IS FINAL SURFACE ELEVATION FOLLLOWING
PLACEMENT OF ALL SURFACING MATERIALS
3. GRADE ALL AREAS TO PROVIDE BASIC DRAINAGE AWAY FROM THE BUILDING.
FINE GRADE AREAS TO DIRECT DRAINAGE TO DRAINAGE STRUCTURES.
4. IMPORTED FILL MATERIAL SHALL BE OBTAINED FROM A WASHINGTON
DEPARTMENT OF TRANSPORTATION APPROVED SOURCE. SUBMIT CERTIFICATE
14 DAYS PRIOR TO CONSTRUCTION.
CONSTRUCTION PERMIT SUBMITTAL
Ste; DATE:
1"=10, HOR ZONTIAAL: NAD 1983/11991 CITY OF L I M E L I T E SHORT PLAT 3/29/17
FIELDBOOK:
'RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
ONE INCH DATUM DRAWING NO:
AT FULL SCALE Planning/Building/Public Works Dept. PAVING AND GRADING C4
IF NOT ONE INCH
SCALE ACCORDINGLY
SHEET: OF:
R-398004
a
I
I
I
I
w
<
� I
3
I
I
I
I
I
I
I
I
- I
I
I
3
SE 162ND ST
rI-I-I-I-I-I-I-I-I-I-II
O
i
—W
Know what's below.
Cal before you dig.
FL=OT=3
EMOVE EX TREE
CATCH BASIN 2
PROTECTION C 1
(TYP)
FILTER FABRIC FENCE �Cl
- REMOVE EX
TREE/SHRUB
- STABILIZED CONSTRUCTION
ENTRANCE
coterra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraengineering.com
O
I
I,
I
I
I
I'
I I I I I I I I � I I I I I I J
FF= 483.13
480.14
= 483.07
O
PRUNE TREES 4-10
L----------I-I
I
/.j
_ O
........ . I
I
10 11 IL II
-I
� / I I
L
=LOT
--- ----;� �� v
POOF EE=494.67
I
-I
=LOT I I
I
I I
-I
I
I
-I
I II
I
I I
I PROPERTY LINE
I -I
I
�I
I II
-I
� I I
F -zt
I'
-I
I
I
-I
I I
SURVEYED: SCALE:
VERTICAL: NAD D983/1991
1988
7 SHARED DRIVEWAYS MB 3 29 17 PA 1 a_ —10f HORIZONTAL: DESIGNED: MB
6 CITY COMMENTS MB 9 09 16 PA
5 CITY COMMENTS MB 8 15 16 PA CHECK Me
4 CITY COMMENTS MB 7/07/16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY DEVELOPMENT ENGINEERING
07
rstraka 06/20/2017 Brianne Bannwarth 06/22/2017
REGIONAL FIRE AUTHORITY
06/27/2017
^APPROVEDcthomas
(a.,
.>
LEGEND
20 0 20
SCALE: 1 = 20
SLOPE LINE
SAND CONE
O 2
CATCH BASIN PROTECTION C 1
xREMOVE TREE/STRUCTURE
FILTER FABRIC FENCE 3
C1
- - - - - - - - TREE PROTECTION
CURB DEMO LINE
SAWCUT LINE
CONSTRUCTION LIMIT
----�--�— INTERCEPTOR SWALE
NOTES
1. SEE SHEET Cl AND C2 FOR NOTES.
2. REMOVE EXISTING FEATURES AS REQUIRED FOR CONSTRUCTION OF NEW
IMPROVEMENTS.
3. COORDINATE REMOVAL OF ELECTRICAL AND FRANCHISE SERVICES WITH
PURVEYOR.
TREE CHART
TREE #
SPECIES
(FEDERAL
CODE)
SIZE
(IN)
CURRENT
HEALTH
RATING
DRIP LINE RADIUS (FT)
NORTH
SOUTH
EAST
WEST
1
AEHI
23.5
GOOD
17
20
20
18
2
AEHI
18.5
GOOD
16
13
15
18
3
PSME
26.5
GOOD
18
25
15
18
4
PSME
20
GOOD
18
18
15
15
5
PSME
22.8
GOOD
18
23
15
15
6
PSME
29
GOOD
18
24.6
15
15
7
PSME
24.5
GOOD
18
1 25
15
15
8
PSME
18
GOOD
18
15
15
15
9
PSME
21.8
GOOD
18
20
15
15
10
PSME
30.5
GOOD
18
25
15
15
11
PSME
24.9
GOOD
18
31
25
25
CONSTRUCTION PERMIT SUBMITTAL
DATE: n
CITY OF LIMELITE SHORT PLAT FlELD3/29/17
RENTON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DRAWING NO:
Planning/Building/Public Works Dept. TESC PLAN C3
R-398003
CITY OF RENTON PERVIOUS CONCRETE PAVEMENT SPECIFICATIONS (APWA GSP 5-06.SA)
5-06 PERVIOUS CONCRETE PAVEMENT
E
00
n
L
a
N
a
0
E
0
w
0
U
N
U
0
cn
-0
i
C
N
1-0
U;
CD
i
z
E
0
0
a
CD
N
a
0
T
C
a
E
0
U
/
w
Li
w
Ld
w
0
0
U
17
5-06.1 DESCRIPTION
THIS WORK SHALL CONSIST OF CONSTRUCTING A PERVIOUS CEMENTITIOUS PAVEMENT COMPOSED OF PORTLAND CEMENT
CONCRETE ON A PREPARED SUBGRADE OR SUBBASE IN ACCORDANCE WITH THESE SPECIFICATIONS AND IN CONFORMITY
WITH THE LINES GRADES, THICKNESSES, AND TYPICAL CROSS -SECTIONS SHOWN IN THE PLANS OR ESTABLISHED BY
THE ENGINEER.
5-06.2 MATERIALS
MATERIALS SHALL MEET THE REQUIREMENTS OF THE FOLLOWING SECTIONS:
PORTLAND CEMENT 9-01
AGGREGATES FOR PORTLAND CEMENT CONCRETE 9-03.1
PREMOLDED JOINT FILLER FOR EXPANSION JOINTS 9-04.1(2)
CURING MATERIALS AND ADMIXTURES 9-23
WATER 9-25
HYDRATION STABILIZING ADMIXTURES SHALL CONFORM TO THE REQUIREMENTS OF SECTION 9-23.6(3) OR 9-23.6(5).
SYNTHETIC FIBERS FOR CONCRETE
WHEN SPECIFIED SYNTHETIC FIBERS TO BE INCLUDED IN THE MIX FOR PORTLAND CEMENT CONCRETE SHALL CONFORM
TO THE REQUIREMENTS OF ASTM D 7508/7508M.
5-06.3 CONSTRUCTION REQUIREMENTS
5-06.3(1) PERVIOUS CONCRETE PRECONSTRUCTION MEETING
PRIOR TO THE START OF CONSTRUCTION OF THE PERVIOUS CONCRETE PAVEMENT SECTION, INCLUDING EXCAVATION OF
THE PAVEMENT SECTION, THE CONTRACTOR SHALL COORDINATE, SCHEDULE AND ATTEND A PRECONSTRUCTION MEETING
FOR THE PERVIOUS CONCRETE PAVEMENT. THE FOLLOWING ARE REQUIRED TO ATTEND THE MEETING:
1. CONTRACTING AGENCY REPRESENTATIVE.
2. GENERAL CONTRACTOR'S REPRESENTATIVE(S).
3. ENGINEER OF RECORD FOR THE PERVIOUS CONCRETE PAVEMENT.
4. CONCRETE PLACEMENT LEAD PERSON(S).
5. ASSOCIATED SUBCONTRACTOR'S REPRESENTATIVE.
6. PERVIOUS CONCRETE SUPPLIER'S REPRESENTATIVE.
7. MATERIAL TESTING LABORATORY'S REPRESENTATIVE.
THE MEETING SHALL COVER ALL ASPECTS OF THE WORK INCLUDING, BUT NOT LIMITED TO:
1. SUBMITTALS.
2. SHORT AND LONG TERM SCHEDULE.
3. INSPECTION OF THE WORK.
4. PROTECTION OF THE WORK.
5. PERVIOUS CONCRETE PLACEMENT.
6. CURING.
7. MATERIALS.
8. SPECIFICATIONS.
9. TESTING.
10. TEST PANEL AND JMF.
11. ACCEPTANCE CRITERIA.
5-06.3(2) PERVIOUS CONCRETE MIX DESIGN
THE CONTRACTOR SHALL PROVIDE A MIX DESIGN FOR PERVIOUS CONCRETE AND SHALL SUBMIT THE MIX DESIGN TO
THE ENGINEER IN WRITING. PERVIOUS CONCRETE SHALL NOT BE PLACED IN THE TEST PANELS WITHOUT A MIX DESIGN
THAT HAS BEEN REVIEWED AND ACCEPTED BY THE ENGINEER.
5-06.3(2)A MIX DESIGN CRITERIA
THE CONTRACTOR SHALL INCLUDE THE FOLLOWING ELEMENTS AND RESULTS OF THE DESCRIBED PROCEDURES IN THE
PROPOSED MIX DESIGN:
1. A UNIQUE IDENTIFICATION NUMBER FOR THE MIX DESIGN THAT IS APPROVED FOR THE JOB MIX FORMULA (JMF).
2. PORTLAND CEMENT SHALL BE TYPE I, TYPE 11, TYPE 1-11 TYPE IP, OR TYPE IS.
3. THE CEMENTITIOUS CONTENT, INCLUDING POZZOLANS IF USED, SHALL BE A MINIMUM OF 480 POUNDS PER CUBIC
YARD.
4. THE MIX SHALL INCORPORATE A HYDRATION STABILIZING ADMIXTURE.
5. SYNTHETIC MICROFIBERS MAY BE UTILIZED AT THE MANUFACTURER'S RECOMMENDED DOSAGE RATE.
6. THE WATER / CEMENT RATIO SHALL NOT EXCEED 0.35.
7. NO MORE THAN 25 PERCENT OF PORTLAND CEMENT IN THE MIX, BY WEIGHT, MAY BE REPLACED BY FLY ASH,
GROUND GRANULATED BLAST FURNACE SLAG, OR A COMBINATION OF BOTH.
8. COARSE AGGREGATE SHALL CONFORM TO SECTION 9-03.1(4), AASHTO GRADING NO.8.
5-06.3(2)B JOB MIX FORMULA (JMF)
THE APPROVED MIX DESIGN ESTABLISHED THROUGH THE APPROVED TEST PANEL BECOMES THE JMF.
5-06.3(3) SUBMITTALS
IN ACCORDANCE TO SECTION 1-05.3, THE CONTRACTOR SHALL SUBMIT THE FOLLOWING ITEMS TO THE ENGINEER FOR
ACCEPTANCE PRIOR TO PLACING ANY PERVIOUS CONCRETE PAVEMENT:
5-06.3(4) EQUIPMENT
EQUIPMENT NECESSARY FOR HANDLING MATERIALS, MIXING, DELIVERING, AND PERFORMING ALL PARTS OF THE WORK,
SHALL BE IN GOOD REPAIR, DESIGNED FOR THE TASK, AND OPERATED BY TRAINED AND QUALIFIED PERSONNEL.
5-06.3(4)A BATCHING PLANT AND EQUIPMENT
PERVIOUS CONCRETE SHALL BE CENTRALLY MIXED IN A PLANT WITH A CURRENT NRMCA CERTIFICATION.
5-06.3(4)B MIXER TRUCKS
PERVIOUS CONCRETE SHALL BE TRANSPORTED TO THE LOCATION BY TRUCK MIXERS, NON -AGITATING TRUCKS SHALL
NOT BE USED FOR THE TRANSPORT OF PERVIOUS CONCRETE. THE DRUMS ON MIXER TRUCKS USED TO TRANSPORT
PERVIOUS CONCRETE SHALL HAVE FINS THAT ARE NOT EXCESSIVELY WORN, DAMAGED OR HAVE EXCESSIVE CONCRETE
BUILDUP. MIXER TRUCKS SHALL HAVE A CURRENT NRMCA CERTIFICATION.
5-06.3(4)C SIDE FORMS
PERVIOUS CONCRETE SHALL BE PLACED IN STATIONARY FORMS. IF PERVIOUS CONCRETE IS TO BE PLACED AGAINST A
CURB, PREVIOUSLY PLACED CONCRETE, OR OTHER EXISTING STRUCTURE, THEY MAY BE USED AS A SIDE FORM FOR
THE PERVIOUS CONCRETE PAVING. FORMS FOR PERVIOUS CONCRETE SHALL BE MADE OF STEEL OR WOOD AND SHALL
BE IN GOOD CONDITION, AND SHALL BE CAPABLE OF BEING ANCHORED IN PLACE SO THAT THEY WILL BE TRUE TO
GRADE, LINE AND SLOPE. FORMS SHALL BE SUFFICIENTLY RIGID TO MAINTAIN SPECIFIED TOLERANCES AND CAPABLE
OF SUPPORTING CONCRETE AND MECHANICAL CONCRETE PLACING EQUIPMENT. FORMS SHALL BE IN GOOD CONDITION,
STRAIGHT, CLEAN, FREE OF DEBRIS, NON -ADHERENT RUST AND HARDENED CONCRETE.
SET, ALIGN, AND BRACE FORMS SO THAT THEY HARDENED PAVEMENT MEETS THE LINES, GRADES AND SLOPES AS
SHOWN IN THE DRAWINGS. APPLY FORM -RELEASE AGENT TO THE FORM FACE, WHICH WILL BE IN CONTACT WITH
CONCRETE, IMMEDIATELY BEFORE PLACING CONCRETE. FORM RELEASE AGENT SHALL NOT BE APPLIED TO PREVIOUSLY
PLACED CONCRETE. PREVIOUSLY PLACED PAVEMENT SHALL BE PROTECTED FROM DAMAGE.
THE CONTRACTOR SHALL INSPECT ALL FORMS FOR LINE, GRADE AND SLOPE. NO PERVIOUS CONCRETE SHALL BE
PLACED UNTIL THE FORMS HAVE BEEN INSPECTED BY THE ENGINEER.
5-06.3(4)D FINISHING EQUIPMENT
FINISHING EQUIPMENT FOR PERVIOUS CONCRETE PAVING SHALL BE DESIGNED FOR THE INTENDED WORK, SHALL BE
CLEAN AND IN GOOD OPERATING CONDITION.
PERVIOUS CONCRETE THAT IS IMPROPERLY CURED OR IS ALLOWED TO FREEZE DURING THE INITIAL SEVEN (7) DAY
CURING PERIOD WILL BE REJECTED.
PERVIOUS CONCRETE PAVEMENT THAT DOES NOT MEET THE ACCEPTANCE CRITERIA PUT FORTH IN SECTION 5-06.3(6)
WILL BE REJECTED BY THE ENGINEER ON A LOT BY LOT BASIS.
DURING THE REMOVAL PROCESS OF THE REJECTED PAVEMENT, THE CONTRACTOR SHALL IMPLEMENT MEASURES TO
PROTECT THE ADJACENT PERVIOUS CONCRETE PAVEMENT TO REMAIN. IF PERVIOUS CONCRETE PAVEMENT BECOMES
DAMAGED BY THE CONTRACTOR DURING REMOVAL OF THE REJECTED PAVEMENT THEN ADDITIONAL PAVEMENT AREAS MAY
BE REJECTED BY THE ENGINEER TO THE NEXT PLANNED JOINT.
FRESH PERVIOUS CONCRETE THAT HAS BEEN REJECTED BY THE ENGINEER, OR THE CONTRACTOR, SHALL NOT BE
PLACED, OR SHALL BE REMOVED AND REPLACED, AT NO ADDITIONAL COST.
5-06.3(8) MIXING PERVIOUS CONCRETE
BATCH, MIX AND DELIVER PERVIOUS CONCRETE IN COMPLIANCE WITH ASTM C94/C94M EXCEPT THAT PERVIOUS
CONCRETE SHALL NOT BE TRANSIT MIXED OR SHRINK MIXED. IF WATER IS ADDED TO THE MIX AFTER IT IS DELIVERED
ON SITE, THE FRESH DENSITY FOR THE PERVIOUS CONCRETE SHALL MEET THE REQUIREMENTS OF THE APPROVED JMF
REFERENCED IN THIS SECTION.
5-06.3(8)A LIMITATIONS OF MIXING PERVIOUS CONCRETE
MIXING AND PLACING CONCRETE SHALL BE DISCONTINUED WHEN A DESCENDING AIR TEMPERATURE IN THE SHADE AWAY
FROM ARTIFICIAL HEAT REACHES 40' F AND SHALL NOT BE RESUMED UNTIL AN ASCENDING AIR TEMPERATURE IN THE
SHADE AND AWAY FROM ARTIFICIAL HEAT REACHES 40° F.
THE TEMPERATURE OF FRESH PERVIOUS CONCRETE SHALL NOT BE LESS THAN 55° F, NOR MORE THAN 90° F WHEN
PLACED.
PERVIOUS CONCRETE SHALL NOT BE MIXED WITH AGGREGATES AT LESS THAN 32° F.
5-06.3(9) SUBGRADE PREPARATION AND SUBBASE
PREPARE AND PROTECT SUBGRADE IN ACCORDANCE WITH SECTION 2-06.
EQUIPMENT USED FOR STRIKING OFF THE PERVIOUS CONCRETE SHALL LEAVE A SMOOTH SURFACE AT THE PLANNED PREPARE AND PROTECT SUBBASE IN ACCORDANCE WITH SECTION 4-04.
GRADES AND SHALL NOT CAUSE EXCESS PASTE TO BE LEFT ON, OR DRAWN TO, THE SURFACE. IF ROLLERS OR
SPINNING SCREEDS ARE USED TO COMPACT, THEY SHALL BE OF SUFFICIENT WEIGHT AND WIDTH TO COMPACT THE
PERVIOUS CONCRETE UNIFORMLY THROUGH ITS DEPTH AND TO GRADE WITHOUT MARRING THE SURFACE. EQUIPMENT 5-06.3(10) PLACING, SPREADING, FINISHING, EDGING, TOLERANCES AND CURING
USED FOR COMPACTING PERVIOUS CONCRETE SHALL NOT CAUSE THE SURFACE TO CLOSE OR OTHERWISE CLOG AND PERVIOUS CONCRETE SHALL NOT BE PLACED, COMPACTED OR FINISHED WHEN THE NATURAL LIGHT IS INADEQUATE,
SHALL PRODUCE A SURFACE THAT IS FREE OF RIDGES OR OTHER IMPERFECTIONS. TOOLS USED FOR PRODUCING UNLESS AN ADEQUATE LIGHTING SYSTEM IS IN OPERATION. THE ADEQUACY OF LIGHT WILL BE DETERMINED BY THE
JOINTS SHALL BE DESIGNED AND MANUFACTURED FOR THE PURPOSE AND SHALL NOT OTHERWISE DAMAGE OR MAR THE ENGINEER.
SURFACE.
WET THE SURFACE OF THE SUBBASE WITH WATER IMMEDIATELY BEFORE PLACING PERVIOUS CONCRETE. DEPOSIT
VIBRATING EQUIPMENT SHALL NOT BE USED FOR PLACEMENT OR COMPACTION OF PERVIOUS CONCRETE. CONCRETE EITHER DIRECTLY FROM THE TRANSPORTING EQUIPMENT OR BY CONVEYOR ON THE SUBBASE, UNLESS
OTHERWISE SPECIFIED. PERVIOUS CONCRETE SHALL NOT BE PLACED ON FROZEN SUBBASE. DEPOSIT CONCRETE
5-06.3(5) MEASURING AND BATCHING MATERIALS BETWEEN THE FORMS TO AN APPROXIMATELY UNIFORM HEIGHT. SPREAD THE CONCRETE USING MECHANIZED EQUIPMENT
MEASURING AND BATCHING MATERIALS FOR PERVIOUS CONCRETE PAVEMENT SHALL CONFORM TO THE REQUIREMENTS OF OR HAND TOOLS. VIBRATING EQUIPMENT SHALL NOT BE USED FOR SPREADING PERVIOUS CONCRETE.
SECTION 5-05.3(4).
5-06.3(6) ACCEPTANCE
FOR ACCEPTANCE, PERVIOUS CONCRETE PAVEMENT WILL BE DIVIDED INTO LOTS AS FOLLOWS: A SINGLE LOT (LOT) IS
REPRESENTED BY THE LESSER OF: ONE (1) DAY'S PRODUCTION OR 360 SQUARE YARDS OF PERVIOUS CONCRETE IN
PLACE. WHERE THE CONTRACTOR HAS MORE THAN ONE CREW PLACING PERVIOUS CONCRETE, LOTS WILL BE
ASSOCIATED WITH EACH CREW. REPRESENTATIVE LOT SIZE WILL BE DETERMINED TO THE NEAREST SQUARE YARD. IF
NO SAMPLE IS TAKEN ON A DAY, THAT DAY'S QUANTITIES MAY BE INCLUDED IN THE NEXT OR PREVIOUS DAY'S LOT(S).
THE ENGINEER MAY ISOLATE AN AREA OF PERVIOUS CONCRETE WITHIN A LOT THAT IS DEEMED TO BE DEFECTIVE IN
ANY WAY AND SUCH AN AREA WILL BE CONSIDERED TO BE A NEW LOT FOR PURPOSES OF ACCEPTANCE. NEW LOTS
DETERMINED IN THIS MANNER SHALL BE EXTENDED AS NECESSARY SUCH THAT THEY ARE BOUNDED BY PLANNED
JOINTS. ACCEPTANCE OF A LOT OF PERVIOUS CONCRETE PAVEMENT WILL BE BASED ON THE FOLLOWING CRITERIA:
STRIKE OFF CONCRETE BETWEEN FORMS USING A FORM -RIDING PAVING MACHINE, ROLLER SCREED, OR SPINNING
SCREED.
COMPACT CONCRETE TO A UNIFORMLY DENSE STRUCTURE WITHOUT CLOGGING THE SURFACE WITH PASTE.
FINISH THE PERVIOUS CONCRETE TO A UNIFORM, OPEN -TEXTURED SURFACE TO MATCH THE APPEARANCE OF THE
APPROVED JMF TEST PANEL.
EDGES SHALL BE HAND TOOLED TO A RADIUS OF % INCH.
CI IRIN(; kAATFRIAI C FnP PFR\/Inl IC r r1Nr RFTF CNAI I RF IN PI Ar F Mr) kAnRF THAN M KAINI ITFC r)F nlgr HAR(;F r)NTn
THE SUBBASE. THE PAVEMENT SURFACE AND ALL EXPOSED EDGES SHALL BE COMPLETELY COVERED WITH SHEET
FAILURE TO INSTALL ACCEPTABLE TEST PANEL(S) OF PERVIOUS CONCRETE WILL INDICATE AN UNAPPROVED TEST
PANEL(S) AND REQUIRE NEW TEST PANEL(S) FOR REVIEW.
THE COMPLETED AND APPROVED TEST PANEL(S) SHALL ESTABLISH THE JMF.
THE APPROVED TEST PANEL SHALL MEET THE REQUIREMENTS OF SECTION 5-03.3(6).
UPON SUCCESSFUL COMPLETION OF THE INFILTRATION TEST, UNLESS OTHERWISE DETERMINED BY THE ENGINEER, THREE
(3), CORES WILL BE CUT IN ACCORDANCE WITH ASTM C42 AND WILL BE USED TO VALIDATE THE MIX DESIGN UNDER
THE ACCEPTANCE CRITERIA OF SECTION 5-06.3(6). CORES SHALL BE TAKEN AT THE SAME LOCATION WHERE THE
INFILTRATION TEST WAS CONDUCTED. THE AVERAGE HARDENED DENSITY OF THE CORES SHALL BE THE HARDENED
DENSITY USED FOR THE JMF. THE HARDENED DENSITY OF EACH CORE USED FOR DETERMINING THE JMF SHALL BE
WITHIN FIVE (5) PERCENT OF THE MEAN VALUE OF THE THREE CORES. CORE HOLES SHALL BE FILLED BY THE
CONTRACTOR WITH PERVIOUS CONCRETE MEETING THE PROPOSED JMF AND SHALL MATCH ADJACENT PAVEMENT COLOR,
TEXTURE AND GRADE.
THE COMPLETED AND ACCEPTED TEST PANELS SHALL BE MAINTAINED AND PROTECTED THROUGHOUT THE DURATION OF
THE WORK AND MAY NOT BE DEMOLISHED AND DISPOSED OF WITHOUT WRITTEN PERMISSION FROM THE ENGINEER. IF
THE TEST PANEL(S) IS INCORPORATED INTO THE WORK, IT SHALL REMAIN IN PLACE ACCEPTED AS A SINGLE LOT.
5-06.3(11) JOINTS
CONSTRUCT JOINTS AT THE LOCATIONS, DEPTHS AND WITH HORIZONTAL DIMENSIONS INDICATED ON PLANS UNLESS
NOTED OTHERWISE IN THIS SECTION. JOINTS SHALL BE OF THREE (3) TYPES: CONSTRUCTION, CONTRACTION, ISOLATION.
CONSTRUCTION JOINTS SHALL BE FORMED AT THE END OF A DAY'S WORK OR WHEN NECESSARY TO STOP PRODUCTION
FOR ANY REASON. CONTRACTION JOINTS SHALL BE USED TO CONTROL RANDOM CRACKING. ISOLATION JOINTS SHALL
BE USED WHERE THE PERVIOUS CONCRETE ABUTS EXISTING FACILITIES OR WHERE SHOWN ON THE PLANS.
5-06.3(11)A CONSTRUCTION JOINTS
CONSTRUCTION JOINTS SHALL BE LOCATED AT THE LOCATION OF A PLANNED CONTRACTION OR ISOLATION JOINT.
CONSTRUCTION JOINTS ARE TO BE FORMED BY PLACING A HEADER BETWEEN THE FORMS, AT RIGHT ANGLES, TO THE
FULL DEPTH OF THE FINISHED PERVIOUS CONCRETE, AND SET TO THE HEIGHT OF THE FORMS. PERVIOUS CONCRETE
SHALL BE PLACED AGAINST THE HEADER AND COMPACTED AND FINISHED AS NORMAL, INCLUDING EDGING. THE HEADER
SHALL REMAIN IN PLACE UNTIL PAVING RESUMES.
5-06.3(11)B CONTRACTION JOINTS
CONTRACTION JOINTS (TRANSVERSE AND LONGITUDINAL) SHALL BE CONSTRUCTED AT THE LOCATIONS AND INTERVALS
SHOWN IN THE CONTRACT. CONTRACTION JOINTS SHALL BE A DEPTH OF 1/3 THE THICKNESS OF THE PERVIOUS
CONCRETE PAVEMENT SECTION AND HAVE A WIDTH OF NO MORE THAN 1/4 INCH. CONTRACTION JOINTS SHALL NOT
BE SAW CUT UNLESS SPECIFICALLY NOTED ON THE PLANS. SAW CUT JOINTS SHALL HAVE A MINIMUM WIDTH OF 1/8
INCH. PLASTIC FORMED CONTRACTION JOINTS SHALL BE TOOLED ON BOTH SIDES OF THE JOINT WITH A RADIUS OF
INCH. TOOL JOINT TO THE DEPTH AND WIDTH IN FRESH CONCRETE IMMEDIATELY AFTER THE CONCRETE IS COMPACTED.
5-06.3(11)C ISOLATION JOINTS
ISOLATION JOINTS SHALL BE PLACED WHERE THE PERVIOUS CONCRETE ABUTS EXISTING STRUCTURES OR WHERE SHOWN
ON THE PLANS. ISOLATION JOINTS SHALL CONTINUE THROUGH THE DEPTH OF THE PERVIOUS CONCRETE USING A 3/8
INCH PREMOLDED JOINT FILLER MEETING THE REQUIREMENTS OF SECTION 9-04.1(2). ISOLATION JOINTS MAY BE
FORMED BY FORMING A CONSTRUCTION JOINT AND AFFIXING THE PREMOLDED JOINT FILLER AGAINST ONE SIDE OF THE
JOINT AND PLACING FRESH PERVIOUS CONCRETE AGAINST IT. ISOLATION JOINTS AND FILLER SHALL BE FLUSH WITH
THE SURROUNDING PERVIOUS CONCRETE AND SHALL NOT DEVIATE FROM THE ACCEPTANCE CRITERIA FOR SMOOTHNESS
AS SHOWN IN SECTION 5-06.3(6). THE EDGE OF THE PERVIOUS CONCRETE ADJACENT THE PREMOLDED JOINT FILLER
SHALL BE HAND TOOLED WITH A i% INCH RADIUS.
5-06.3(12) COLD WEATHER WORK
WHEN CONCRETE IS BEING PLACED AND THE AMBIENT AIR TEMPERATURE IS EXPECTED TO DROP BELOW 35° F DURING
THE DAY OR NIGHT, THE CONTRACTOR SHALL PROTECT THE CONCRETE FROM FREEZING. THE CONTRACTOR SHALL
SUBMIT FOR APPROVAL A COLD WEATHER PLAN PRIOR TO PLACING CONCRETE WHEN AMBIENT AIR TEMPERATURE BELOW
35° F IS ANTICIPATED, OR WHEN REQUESTED BY THE ENGINEER. WHEN A COLD WEATHER PLAN IS REQUIRED,
PERVIOUS CONCRETE SHALL NOT BE PLACED WITHOUT AN APPROVED COLD WEATHER PLAN.
1. GRADE: CONFORM TO THE DIMENSIONS, LINES, SLOPES AND GRADES SPECIFIED ON THE PLANS. PERVIOUS CURING MATERIALS CONFORMING TO SECTION 9-23.1. THE CURING MATERIAL SHALL SECURED AT ALL EXTERIOR EDGES UNDER THE COLD WEATHER PLAN, THE CONTRACTOR SHALL, PROVIDE A SUFFICIENT SUPPLY OF STRAW, HAY, BLANKETS,
CONCRETE PAVEMENT SHALL BE TRUE TO PLANNED GRADES AND SHALL NOT DEVIATE FROM GRADE MORE THAN Y4 INCH AND INTERIOR LAPS WITHOUT DAMAGING THE PERVIOUS CONCRETE. THE METHOD OF SECURING THE CURING MATERIAL OR OTHER SUITABLE BLANKETING MATERIAL AND SPREAD IT OVER THE PAVEMENT TO A SUFFICIENT DEPTH TO PREVENT
IN TEN (10) FEET. WHERE ABUTTING EXISTING FACILITIES SUCH AS SIDEWALKS, WALKWAYS, CURBS, DRIVEWAYS OR SHALL PREVENT WIND FROM REMOVING THE SHEET AND FROM BLOWING UNDER THE SHEET ACROSS THE SURFACE OF FREEZING OF THE CONCRETE. THE BLANKET MATERIAL SHALL BE PLACED ON TOP OF THE SHEET CURING MATERIALS
OTHER PAVEMENTS, THE PERVIOUS CONCRETE SHALL BE FLUSH. THE CONCRETE. CURE THE PAVEMENT FOR A MINIMUM OF SEVEN (7) UNINTERRUPTED DAYS. AND COVERED WITH A LAYER OF BURLAP OR PLASTIC SHEETING, WEIGHTED OR ANCHORED TO PREVENT THE WIND
2. CONFORMANCE TO JMF: THE PERVIOUS CONCRETE PAVEMENT USED SHALL CONFORM TO THE MIX DESIGN FOR THE FROM DISPLACING THE INSULATION. AT NO TIME DURING THE CURING PERIOD SHALL THE TEMPERATURE OF THE
JMF WITHIN THE LIMITS AS SET FORTH IN SECTION 6-02.3(5)C AND AS DETERMINED FROM THE ACCEPTED TEST PANEL. ALL TRAFFIC (FOOT AND VEHICULAR), STAGING, STOCKPILING OR OTHER WORK SHALL BE KEPT OFF OF THE PERVIOUS PERVIOUS CONCRETE BE ALLOWED TO DROP BELOW 55° F. THE ENGINEER MAY REQUIRE RECORDING THERMOMETERS
3. COMPACTED THICKNESS AND AVERAGE HARDENED DENSITY: AFTER A MINIMUM OF SEVEN (7) CALENDAR DAYS OF CONCRETE PAVEMENT DURING THE CURING PERIOD. ANY TESTING FOR ACCEPTANCE SHALL NOT OCCUR UNTIL THE END IF DAYTIME TEMPERATURE IS BELOW 50°. THE CURING PERIOD MAY BE EXTENDED BY THE ENGINEER IF THE PERVIOUS
CURING, REMOVE AND MEASURE THREE (3) CORES FROM EACH LOT. REMOVE CORES IN ACCORDANCE WITH ASTM OF THE CURING PERIOD. CONCRETE TEMPERATURE HAS BEEN ALLOWED TO DROP BELOW 55° F.
C42/C42M. MEASURE THE LENGTH OF EACH CORE IN ACCORDANCE WITH ASTM C1542/1542M. NO SINGLE CORE PROTECT CONCRETE FROM FREEZING AND COLD WEATHER IN ACCORDANCE WITH 5-06.3(12). THE COLD WEATHER PROTECTION SHALL BE MAINTAINED FOR SEVEN (7) DAYS. PERVIOUS CONCRETE THAT HAS FROZEN
SHALL BE LESS THAN 3/4 INCH OF THE DESIGN DEPTH ON THE DRAWINGS. THE AVERAGE OF ALL CORES FROM A LOT DURING THIS PERIOD WILL BE REJECTED.
SHALL BE WITHIN MINUS 3/8 INCH OF THE DESIGN DEPTH ON THE PLANS. AFTER LENGTH IS MEASURED, MEASURE
HARDENED DENSITY OF EACH CORE IN THE LOT IN ACCORDANCE WITH ASTM C1754/C1754M. THE HARDENED DENSITY 5-06.3(10)A CONTRACTOR'S QUALIFICATIONS 5-06.3(13) PROTECTION OF PERVIOUS CONCRETE PAVEMENT
FROM A LOT MUST BE WITHIN +/- 5 PERCENT OF THE AVERAGE HARDENED DENSITY OF THE JMF (APPROVED TEST THE CONTRACTOR SHALL EMPLOY NO LESS THAN ONE (1) NATIONAL READY MIXED CONCRETE ASSOCIATION (NRMCA)
PANEL). CERTIFIED PERVIOUS CONCRETE CRAFTSMAN FOR EACH CREW, WHO MUST BE ON SITE, OVER -SEEING THE WORK AS PART OF THE CONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN (SWPPP), RAIN RUNOFF, SURFACE WATER
4. INFILTRATION RATE: THE INFILTRATION RATE AT ANY SINGLE TEST POINT SHALL NOT BE LESS THAN 100 INCHES PER DURING ALL PERVIOUS CONCRETE PLACEMENT; OR EMPLOY NO LESS THAN THREE (3) NRMCA CERTIFIED PERVIOUS OF ANY KIND AND SEDIMENT SHALL BE PREVENTED FROM ENTERING THE AREA OF PERVIOUS CONCRETE CONSTRUCTION,
HOUR. CONCRETE INSTALLERS PER CREW, WHO MUST BE ON SITE WORKING DURING EACH PERVIOUS CONCRETE PLACEMENT. INCLUDING EXCAVATION, UNTIL THE PERVIOUS CONCRETE APPLICATION HAS CURED, TESTING IS COMPLETED AND
5. FRESH DENSITY: THE FRESH DENSITY OF EACH LOT WILL BE MEASURED BY ASTM C1688 AT THE POINT OF THE MINIMUM NUMBER OF CERTIFIED INDIVIDUALS MUST BE PRESENT ON EACH CREW FOR EVERY PERVIOUS CONCRETE DETERMINED TO MEET SPECIFICATIONS AND THE ADJACENT AREAS THAT SHEET FLOW/DRAIN ONTO THE PERVIOUS
PLACEMENT SHALL BE WITHIN +/- FIVE (5) POUNDS PER CUBIC FOOT OF THE FRESH DENSITY DETERMINED FROM PLACEMENT, INCLUDING THE TEST PANEL PLACEMENTS, AND A CERTIFIED INDIVIDUAL MUST BE IN CHARGE OF THE CONCRETE ARE PERMANENTLY STABILIZED FROM EROSION AND PLANTINGS ARE ESTABLISHED. ONCE PAVEMENT IS
APPROVED TEST PANEL). PLACEMENT CREW AND PROCEDURES. PLACED, FLOW DIVERSION MEASURES AND PROTECTIVE COVERS SHALL CONTINUALLY BE MAINTAINED UNTIL ADJACENT
THE JMF
( ) AREAS ARE PERMANENTLY STABILIZED AND CONCRETE HAS BEEN ACCEPTED. CONSTRUCTION VEHICULAR TRAFFIC SHALL
6. APPEARANCE: THE APPEARANCE OF EACH LOT SHALL BE CONSISTENT WITH THE JMF (APPROVED TEST PANEL). IF, IN THE OPINION OF THE ENGINEER, PERSONNEL USED FOR INSTALLING PERVIOUS CONCRETE ARE UNQUALIFIED, NOT BE ALLOWED ONTO THE PERVIOUS CONCRETE PAVEMENT.
THE PERVIOUS CONCRETE PAVEMENT SHALL HAVE A CONSISTENT SURFACE TEXTURE, SHALL NOT BE RAVELED, SHALL INATTENTIVE TO QUALITY, OR UNSAFE, THEY SHALL BE REMOVED OR REASSIGNED FROM INSTALLATION OF PERVIOUS
1. THE SOURCE OF ALL MATERIALS PROPOSED FOR USE IN CONSTRUCTING PERVIOUS CONCRETE PAVEMENT. BE FREE OF RIDGES OR OTHER SURFACE IMPERFECTIONS, SHALL HAVE JOINTS THAT ARE IN THE SPECIFIED LOCATION CONCRETE AT THE WRITTEN REQUEST OF THE ENGINEER. DO NOT OPEN THE PAVEMENT TO VEHICULAR TRAFFIC UNTIL THE CONCRETE HAS CURED FOR AT LEAST SEVEN (7)
2. BATCH WEIGHTS FOR ALL CONSTITUENTS OF ONE (1) CUBIC YARD OF THE PROPOSED PERVIOUS CONCRETE MIX. AND ARE CONSTRUCTED PER SPECIFICATION, AND SHALL BE FREE OF CRACKS. UNINTERRUPTED DAYS, TESTING HAS BEEN COMPLETED, AND THE PAVEMENT HAS BEEN ACCEPTED BY THE ENGINEER.
3. THE SPECIFIC GRAVITY (SSD) OF ALL AGGREGATES TO BE USED IN THE PROPOSED PERVIOUS CONCRETE MIX.
4. THE PROPOSED GRADATION OF COARSE AGGREGATES USED IN PERVIOUS CONCRETE. TESTING FOR ACCEPTANCE WILL BE PERFORMED BY THE ENGINEER.
5. THE DESIGNED VOLUME IN CUBIC FEET OF ALL PROPOSED COMPONENTS FOR 1(ONE) CUBIC YARD OF THE
PROPOSED PERVIOUS CONCRETE MIX.
6. THE DESIGN WATER / CEMENT RATIO OF THE PROPOSED MIX DESIGN.
7. THE FRESH DENSITY OF THE PROPOSED PERVIOUS CONCRETE MIXTURE AS DETERMINED BY ASTM C1688.
8. CATALOGUE CUTS AND CERTIFICATES OF COMPLIANCE FOR ALL PROPOSED ADMIXTURES.
9. MILL CERTIFICATION OF THE PORTLAND CEMENT AND POZZOLANS, IF USED, FOR THE CURRENT LOT TO BE USED IN
THE PRODUCTION OF THE PROPOSED PERVIOUS CONCRETE MIX. THE CONTRACTOR SHALL MAINTAIN THIS SUBMITTAL
THROUGHOUT THE DURATION OF THE PROJECT AS LOTS CHANGE
5-06.3(6)A INFILTRATION RATE OF THE PLACED PAVEMENT
THE INFILTRATION RATE OF THE PERVIOUS CONCRETE SHALL BE DETERMINED AT FOUR (4) RANDOM LOCATIONS WITHIN
EACH LOT. THE LOCATIONS FOR CONDUCTING INFILTRATION TESTS WILL BE DETERMINED BY THE ENGINEER. THE
CONTRACTOR SHALL COORDINATE AND SCHEDULE TESTING WITH THE ENGINEER A MINIMUM OF FIVE (5) WORKING DAYS
IN ADVANCE. THE INFILTRATION RATE ON THE FINISHED SURFACE WILL BE DETERMINED IN ACCORDANCE WITH ASTM
C1701, EXCEPT THE INFILTRATION RING DIAMETER MAY BE 12-INCHES TO 24-INCHES IN DIAMETER. THE INFILTRATION
TEST WILL BE CONDUCTED AFTER A MINIMUM OF SEVEN (7) CALENDAR DAYS OF CURING HAS OCCURRED.
10. CURRENT CERTIFICATION BY THE NATIONAL READY MIX CONCRETE ASSOCIATION (NRMCA) FOR THE BATCH PLANT(S)
TO BE USED IN THE PRODUCTION OF PERVIOUS CONCRETE. IF THE MEASURED INFILTRATION RATE IS LESS THAN 100 INCHES/HOUR AT ANY TEST LOCATION, THE CONTRACTOR MAY
11. CURRENT CERTIFICATIONS BY THE NRMCA FOR THE TRUCKS TO BE USED IN TRANSPORTING PERVIOUS CONCRETE REQUEST IN WRITING THAT THE ENGINEER PERFORM ADDITIONAL INFILTRATION TESTS FOR THE PURPOSE OF ASSESSING
FROM THE BATCH PLANT TO THE POINT OF PLACEMENT. OVERALL INFILTRATION PERFORMANCE AND/OR DETERMINING A DEFECTIVE LOT IN ACCORDANCE WITH SECTION
12. QUALIFICATION DOCUMENTATION FOR CURRENT CERTIFICATIONS BY THE NRMCA FOR THE CONTRACTOR'S PERSONNEL 5-06.3(6). THE DETERMINATION OF A DEFECTIVE LOT, OR LOTS, AND THE EXTENT(S), WILL BE BY THE ENGINEER.
WHO WILL BE INSTALLING PERVIOUS CONCRETE. SEE SECTION 5-06.3(10)A. VALID ACCEPTABLE DOCUMENTATION IS THE THE COST OF ADDITIONAL TESTING SHALL BORNE BY THE CONTRACTOR AT A RATE OF ($$1$$) PER TEST.
NRMCA ISSUED WALLET CARD OR CERTIFICATION CERTIFICATE.
13. AT THE TIME OF DELIVERY OF THE MATERIAL TO THE SITE, THE CONTRACTOR SHALL PROVIDE AN ORIGINAL 5-06.3(7) REJECTION
CERTIFICATE OF COMPLIANCE FOR EACH TRUCKLOAD OF PERVIOUS CONCRETE. THE CERTIFICATE OF COMPLIANCE SHALL PERVIOUS CONCRETE MAY BE REJECTED BY THE CONTRACTOR FOR ANY REASON.
INCLUDE INFORMATION NOTED IN SECTION 6-02.3(5)B. IF THE CERTIFICATE OF COMPLIANCE FROM THE CONCRETE
Ppnni ICFR IC NnT PRr)\iinFn Tr) THE FNhINFFR I IPnN nFl I\/FRY THE TRI ICIII nAn CNAI I Nr)T RF PI ArI.Fn
Know what's below.
Call before you dig.
COLerra
ENGINEERING PLLC
321 3rd Ave South, Suite 307
Seattle, Washington 98104
ph 206.596.7115
coterraeng i neeri ng.com
A TRUCKLOAD OF PERVIOUS CONCRETE WILL BE REJECTED IF THE CERTIFICATE OF COMPLIANCE IS NOT PROVIDED AT
THE TIME OF DELIVERY OF THE MATERIAL TO THE SITE. SEE SECTION 5-06.3(4)B.
5-06.3(10)B TEST PANEL
PRODUCTION PLACEMENT OF PERVIOUS CONCRETE SHALL NOT OCCUR UNTIL THE CONTRACTOR HAS COMPLETED A TEST
PANEL OF PERVIOUS CONCRETE PAVEMENT THAT MEETS ALL OF THE ACCEPTANCE CRITERIA DESCRIBED HEREIN AND IS
ACCEPTED BY THE ENGINEER.
THE CONTRACTOR SHALL CONSTRUCT A TEST PANEL UTILIZING A MINIMUM OF SEVEN (7) CUBIC YARDS OF PERVIOUS
CONCRETE. IF MULTIPLE PAVEMENT SECTION DEPTHS ARE SHOWN ON THE PLANS, A TEST PANEL SHALL BE
CONSTRUCTED FOR EACH PAVEMENT SECTION DEPTH/THICKNESS. THE WIDTH OF THE TEST PANEL SHALL HAVE A
WIDTH NO SMALLER THAN THE GREATEST WIDTH TO BE USED DURING THE CONSTRUCTION AND INSTALLATION OF THE
PERVIOUS CONCRETE ONSITE. THE TEST PANEL(S) SHALL INCLUDE AT LEAST ONE JOINT AND AT THE SPACING
SPECIFIED ON THE PLANS AND SPECIFICATIONS. TEST PANELS MAY BE PLACED NON -CONTIGUOUSLY. THE TEST
PANEL(S) SHALL BE EQUIVALENT AND REPRESENTATIVE OF THE PRODUCTION PERVIOUS CONCRETE PAVEMENT IN ALL
ASPECTS INCLUDING SUBBASE, DEPTH, JOINTS, METHOD OF PLACEMENT, CURING, AND PREPARATION. CONSTRUCTION
AND EVALUATION OF THE TEST PANEL SHALL OCCUR AS FOLLOWS:
1. NOTIFY THE ENGINEER AT LEAST TEN (10) WORKING DAYS BEFORE INSTALLING PERVIOUS CONCRETE TEST PANELS.
2. COORDINATE THE LOCATION OF THE TEST PANEL WITH THE ENGINEER.
3. INSTALL THE TEST PANEL IN ACCORDANCE WITH THE SPECIFICATIONS AND DRAWINGS.
4. NOTIFY THE ENGINEER WHEN THE TEST PANEL IS READY FOR INSPECTION AND ACCEPTANCE TESTING.
5. ACCEPTANCE TESTING WILL BE CONDUCTED IN ACCORDANCE WITH SECTION 5-03.3(6).
6. REMOVE, REPLACE, AND DISPOSE OF ANY UNSATISFACTORY PORTIONS OF TEST PANELS AS DETERMINED BY THE
ENGINEER, AT NO ADDITIONAL COST TO THE CONTRACTING AGENCY.
SURVEYED: SCALE:
1988
VERTICAa_ HOR ZONTAL: N D
q VD 983/1991
7 SHARED DRIVEWAYS MB 3 29 17 PA DESIGNED: 1 -1Of
6 CITY COMMENTS MB 9 09 16 PA MB
5 CITY COMMENTS MB 8 15 16 PA °`�W" MB
4 CITY COMMENTS MB 7 07 16 PA CHECKED: ONE INCH DATUM
PA AT FULL SCALE
IF NOT ONE INCH
NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY
THE CONTRACTOR SHALL TAKE EVERY PRECAUTION TO PROTECT THE PERVIOUS CONCRETE PAVEMENT FROM DAMAGE,
INCLUDING THE INTRODUCTION OF FOREIGN MATERIALS TO THE SURFACE, THROUGHOUT THE COURSE OF THE WORK.
PERVIOUS CONCRETE PAVEMENT THAT IS DAMAGED OR HAS BEEN ADVERSELY IMPACTED BY THE INTRODUCTION OF
FOREIGN MATERIALS SHALL BE REMEDIATED TO THE SATISFACTION OF THE ENGINEER OR REJECTED AND REPLACED TO
THE NEAREST JOINT.
APWA GSP 2-06.3(3)
2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS
(MARCH 9, 2016 APWA GSP)
FB
EVELOPMENT ENGINEERING
rianne Bannwarth 06/22/2017 7
BEFORE PLACING PERMEABLE BALLAST FOR POROUS HMA/WMA, THE CONTRACTOR SHALL BRING THE SUBGRADE TO THE REQUIRED LINE, GRADE, AND
CROSS-SECTION. THE CONTRACTOR SHALL COMPACT THE SUBGRADE TO A DEPTH OF 6 INCHES TO AT LEAST 90 PERCENT, BUT NOT MORE THAN 92 PERCENT,
OF THE MAXIMUM DENSITY AS DETERMINED BY THE COMPACTION CONTROL TESTS DESCRIBED IN SECTION 2-03.3(14)D. TWO (2) DENSITY TESTS WILL BE
CONDUCTED FOR EVERY 5,000 SQUARE FEET OF PREPARED SUBGRADE; OR FOUR (4) TESTS PER 200 LINEAL FEET OF ROADWAY OR SIDEWALK. ALL SUBGRADE
SHALL BE FIRM AND UNYIELDING AS DETERMINED BY THE ENGINEER.
THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT THE PREPARED AND APPROVED SUBGRADE FROM TRAFFIC, WATER RUN-ON, STANDING WATER, OR OTHER
DAMAGE. SUBGRADE THAT HAS BEEN OVER COMPACTED, SHALL BE SCARIFIED TO A MINIMUM DEPTH OF EIGHT (8) INCHES AND RECOMPACTED.
MATERIAL USED TO PROTECT THE SUBGRADE FROM TRAFFIC OR PROVIDE ACCESS TO ADJACENT FACILITIES SHALL BE REMOVED AND THE SUBGRADE COMPACTED
PRIOR TO PLACING GEOTEXTILE, IF USED AND/OR PERMEABLE BALLAST.
CONSTRUCTION PERMIT SUBMITTAL
DATE: n
CITY OF LIMELITE SHORT PLAT FIELDBOOK: 7
REN TON 16204 114TH AVE SE, RENTON, WA 98055 PAGE:
DRAWING NO:
Planning/Building/Public Works Dept. PERVIOUS CONCRETE SPECIFICATIONS C2
R-398002