December 21, 2018
Silvija Jakovljevic
Medici Architects
11711 SE 8th St, Suite 100
Bellevue, WA 98005
SUBJECT: "On Hold" Notice
38th Street Short Plat / LUA18-000683 SHPL-A, ECF
Dear Ms. Jakovljevic:
The Planning Division of the City of Renton accepted the above master application for review on November 19,
2018. During our review, staff has determined that additional information is necessary in order to proceed further.
The following will need to be corrected and submitted before March 21, 2019 so that we may continue the review
of the above subject application:
1. According to the submitted grading plans, is appears that Lots 1-3 would have finished floor elevations
below the grade of Lincoln Ave NE. In order the utilize the private access as an alley for these lots, the
finished floor elevations of these lots must be revised to be level with the elevation of Lincoln Ave NE,
otherwise the private access functions as a shared driveway and the proposal exceeds the maximum
number of lots (4), which are permitted to access off of a shared driveway.
2. In accordance with RMC 4-4-040, the maximum permissible retaining wall height within residential zones
is 6 feet. Please revise the plans as necessary to ensure none of the proposed retaining walls exceeds the
maximum permitted height of 6 feet.
3. Extend the required NE 38th Street frontage improvements to the northwest corner of Lot 5.
The following additional comments were provided by Jonathan Chavez, 425-430-7288:
1. Each lot must have a direct connection to the storm system.
2. Move CB #3 north and connect to CB #1.
3. Move CB #4 to end of roadway and install through curb inlet.
4. Install additional anaerobic grate for ease of maintenance.
5. Provide capacity calculations for existing ditch. The discharge point must designed to eliminate
any erosion potential downstream.
6. Applicant must apply for an easement with the City to be able to construct and maintain private
facilities in public right-of-way.
7. Show shoulder treatment, retaining wall, and guard rails in profile views. Guardrails shall be per
WSDOT standard specifications. Retaining walls within public right of way shall be designed per
AASHTO standards.
8. Curb ramps must meet ADA requirements to the maximum extent feasible.
9. Provide rim and invert elevations on all drainage and sewer structures.
10. Revise utility plan to show minimum horizontal distance of 10 feet between storm and water
mains.
11. Revise utility plan to show minimum horizontal distance of 7 feet between storm and sewer
mains.
12. Revise utility plan to show minimum horizontal distance of 5 feet between storm pipe and
retaining walls, structures, etc.
Once the applicant has reviewed the above comments and amended necessary plan sets and studies to bring the
project closer to compliance with Renton Municipal Code, the applicant shall submit electronic copies of the any
modified plan sheets and studies in compliance with the City’s electronic plan review standards, which may be
found on the City’s website at the following link:
https://edocs.rentonwa.gov/Documents/1/doc/940235/Page1.aspx.
At this time, the review of your project has been placed “on hold” pending receipt of the requested information
and the Environmental Review Committee meeting scheduled for January 7, 2019 has been cancelled. Please
contact me at (425) 430-6598 or jding@rentonwa.gov if you have any questions.
Sincerely,
Jill Ding
Senior Planner
cc: Saphire, LLC/ Owner(s)
Emily Buchwalter, Medici Architects / Applicant
Parties of Record