HomeMy WebLinkAboutD_Admin Decision_NW_Gourmet_Freezer_190108.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Project Location Map
D_NW_Gourmet_Freezer_190108
A. ADMINISTRATIVE REPORT & DECISION
Decision: APPROVED APPROVED SUBJECT TO CONDITIONS DENIED
Report Date: January 8, 2019
Project File Number: PR18-000574
Project Name: NW Gourmet Freezer Addition
Land Use File Number: LUA18-000667, SA-A
Project Manager: Jeffrey Taylor, Assistant Planner
Owner: Mike Gilroy, 600 SW 7th Street, Renton, WA 98057
Applicant: Mike Gilroy, 600 SW 7th Street, Renton, WA 98057
Contact: James Carlton, Tahoma Design Group, 2215 N. 30th Street, Tacoma, WA 98402
Project Location: 600 SW 7th Street, Renton, WA 98057
Project Summary: The applicant is requesting Administrative Site Plan Review, a SEPA Addendum, and
one Modification to the street standards to construct a new 6,386 square foot freezer
for the storage of soup and other food products, located at 600 SW 7th Street. The
subject property totals 218,300 square feet (5.01) acres and is located in the
Employment Area Comprehensive Plan land use designation and Medium Industrial
(IM) zoning classification. The property is developed with a 66,786 square foot
warehouse for the storage of food products. Vehicle access to the subject property
would be maintained on SW 7th Street, utilizing the existing curb cuts. The applicant
has requested a modification to street standards to keep the existing improvements
and not increase their required frontage dedication. The applicant does not propose
to remove any existing trees, and would plant new street trees throughout the
landscape strip along SW 7th Street. The City’s mapping system indicates the site is
within a High Seismic Hazard Area. Studies and reports submitted with the master
application include a geotechnical report and a traffic report.
Site Area: 5 Acres (218,300 Sq. Ft.)
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 2 of 19
D_NW_Gourmet_Freezer_190108
B. EXHIBITS:
Exhibits 1-7: As shown in the SEPA Addendum prepared by City of Renton, dated December 10, 2018
Exhibit 8: Administrative Report and Decision
Exhibit 9: Landscape Plan
Exhibit 10: Architectural Elevations
Exhibit 11: Technical Information Report (TIR), prepared by AHBL, dated September 4, 2018
Exhibit 12: Applicant’s SEPA Addendum Request and Justification
Exhibit 13: Advisory Notes to the Applicant
C. GENERAL INFORMATION:
1. Owner(s) of Record: Gilroy Real Estate Investments, LLC
2. Zoning Classification: Medium Industrial (IM)
3. Comprehensive Plan Land Use Designation: Employment Area (EA)
4. Existing Site Use: Food Warehousing
5. Critical Areas: High Seismic Hazard
6. Neighborhood Characteristics:
a. North: Apartments, Residential Multi-Family (RM-F)
b. East: Warehousing, Medium Industrial (IM)
c. South: Warehousing, Medium Industrial (IM)
d. West: Warehousing, Medium Industrial (IM)
7. Site Area: 5 Acres (218,300 Sq. Ft.)
D. HISTORICAL/BACKGROUND:
Action Land Use File No. Ordinance No. Date
Comprehensive Plan N/A 5758 06/22/2015
Zoning N/A 5758 06/22/2015
Annexation N/A 1745 04/19/1959
Environmental Review LUA13-000562 N/A 06/10/2013
E. PUBLIC SERVICES:
1. Existing Utilities
a. Water: Water service will be provided by the City of Renton. There is an existing water main in SW
7th Street.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 3 of 19
D_NW_Gourmet_Freezer_190108
b. Sewer: Sewer service is provided by the City of Renton. There is an existing sewer main in SW 7th
Street.
c. Surface/Storm Water: The proposal will continue to use the existing storm drain system on site
which collects all water and conveys to the City’s regional stormwater system located in SW 7th
Street.
2. Streets: SW 7th Street is a minor arterial street with an available right-of-way (ROW) width of 80 feet.
3. Fire Protection: Renton Regional Fire Authority (RRFA)
F. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE:
1. Chapter 2 Land Use Districts
a. Section 4-2-020: Purpose and Intent of Zoning Districts
b. Section 4-2-060: Zoning Use Table – Uses Allowed in Zoning Designations
c. Section 4-2-130: Industrial Development Standards
2. Chapter 3 Environmental Regulations and Overlay Districts
a. Section 4-3-050: Critical Area Regulations
3. Chapter 4 City-Wide Property Development Standards
4. Chapter 6 Streets and Utility Standards
a. Section 4-6-060: Street Standards
5. Chapter 9 Permits – Specific
a. Section 4-9-200: Master Plan and Site Plan Review
b. Section 4-9-250: Variance, Waiver, Modification, and Alternatives
6. Chapter 11 Definitions
G. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN:
1. Land Use Element
H. FINDINGS OF FACT (FOF):
1. The Planning Division of the City of Renton accepted the above master application for review on
November 14, 2018 and determined the application complete on November 20, 2018. The project
complies with the 120-day review period.
2. The project site is located at 600 SW 7th Street, Renton, WA 98057.
3. The project site is currently developed with an industrial food warehousing facility.
4. Access to the site would be provided via three existing curb cuts along SW 7th Street.
5. The property is located within the Employment Area (EA) Comprehensive Plan land use designation.
6. The site is located within the Medium Industrial (IM) zoning classification.
7. All 10 trees located on-site are proposed to be retained.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 4 of 19
D_NW_Gourmet_Freezer_190108
8. The site is mapped with High Seismic Hazard.
9. No grading is proposed to construct the project.
10. The applicant is proposing to begin construction in January, 2019 and end in May, 2019.
11. Staff received no public or agency comment letters.
12. Representatives from various city departments have reviewed the application materials to identify and
address issues raised by the proposed development. These comments are contained in the official file,
and the essence of the comments has been incorporated into the appropriate sections of this report
and the Departmental Recommendation at the end of this report.
13. Comprehensive Plan Compliance: The site is designated Employment Area (EA) on the City’s
Comprehensive Plan Map. The purpose of the EA designation is to create areas primarily used for
industrial development or a mix of commercial and industrial uses such as office, industrial,
warehousing, and manufacturing, with access to transportation networks and transit. The proposal is
compliant with the following Comprehensive Plan Goals and Policies if all conditions of approval are
met:
Compliance Comprehensive Plan Analysis
Goal L-P: Minimize adverse impacts to natural systems, and address impacts of past
practice where feasible, through leadership, policy, regulation, and regional
coordination.
Goal L-T: Create a functioning and exemplary urban forest that is managed at optimum
levels for canopy, health, and diversity.
Goal L-U: Preserve, protect, and enhance the quality and functions of the City’s
sensitive areas including: lakes, rivers, major and minor creeks, intermittent stream
courses and their floodplains, wetlands, ground water resources, wildlife habitats, and
areas of seismic and geological hazards.
Policy L-28: Minimize erosion and sedimentation in and near sensitive areas by
requiring appropriate construction techniques and resource practices, such as low
impact development.
Policy L-36: Land uses in areas subject to flooding, seismic, geologic, and coal mine
hazards should be designed to prevent property damage and environmental
degradation before, during, and after construction.
14. Zoning Development Standard Compliance: The purpose of the Medium Industrial Zone (IM) is to
provide areas for medium-intensity industrial activities involving manufacturing, processing, assembly,
and warehousing. Uses in this zone may require some outdoor storage and may create some external
emissions of noise, odor, glare, vibration, etc., but these are largely contained on-site. Compatible uses
that directly serve the needs of other uses permitted within the district are also allowed zone-wide.
Additionally, within the Employment Area designation, an even wider variety of commercial and service
uses may be permitted. The proposal is compliant with the following development standards, as
outlined in RMC 4-2-130.A, if all conditions of approval are met:
Compliance IM Zone Develop Standards and Analysis
Use: Food Warehousing
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 5 of 19
D_NW_Gourmet_Freezer_190108
Staff Comment: Warehousing is permitted in the IM zone.
N/A
Lot Dimensions: The minimum lot size required in the IM zone is 35,000 sq. ft. There
are no minimum lot width or depth requirements.
Staff Comment: The subject property is 218,000 sq. ft. No change to the lot size is
proposed as part of this project.
Setbacks: The minimum front yard setbacks are 20 feet along principal arterial streets
and 15 feet along other streets, provided for lots adjacent to residentially zoned
properties this setback increases to 50 feet. The minimum secondary front yard
setbacks are 20 feet along principal arterial streets and 15 feet along other streets,
provided for lots adjacent to residentially zoned properties this setback increases to 50
feet. There are no side or rear yard setback requirements, except 50 feet if abutting a
lot zoned residential.
Staff Comment: The proposed addition is approximately 151 feet from the front lot line
complying with the required front yard setback. There are no side or rear yard setback
requirements since the subject property is not abutting a residential lot. Therefore, the
project complies with all setback requirements for the zone.
Building Standards: There are no maximum lot coverage requirements for buildings in
the IM zone. There are no maximum building height requirements in the IM zone.
Compliant if
condition of
approval is
met
Landscaping: The City’s landscape regulations (RMC 4-4-070) require a 10-foot
landscape strip along all public street frontages. Additional minimum planting strip
widths between the curb and sidewalk are established according to the street
development standards of RMC 4-6-060. Street trees and, at a minimum, groundcover,
are to be located in this area when present. Spacing standards shall be as stipulated by
the Department of Community and Economic Development, provided there shall be a
minimum of one street tree planted per address. Any additional undeveloped right-of-
way areas shall be landscaped unless otherwise determined by the Administrator.
All parking lots shall have perimeter landscaping as follows:
Such landscaping shall be at least ten feet (10') in width as measured from the street
right-of-way. Standards for planting shall be as follows:
a. Trees shall be two inches (2") in diameter at breast height (dbh) for multi-
family, commercial, and industrial uses at an average minimum rate of one
tree per thirty (30) lineal feet of street frontage.
b. Shrubs at the minimum rate of one per twenty (20) square feet of landscaped
area. Up to fifty percent (50%) of shrubs may be deciduous.
c. Ground cover in sufficient quantities to provide at least ninety percent (90%)
coverage of the landscaped area within three (3) years of installation.
Surface parking lots with more than fourteen (14) stalls shall be landscaped as
follows:
Surface parking lots with between 15 and 50 spaces shall provide 15 sf of landscaping
per parking space, 51 and 99 spaces shall provide 25 sf of landscaping per parking
space, and 100 or more spaces shall provide 35 sf of landscaping per parking space.
Perimeter parking lot landscaping shall be at least 10 feet in width, interior parking lot
landscaped areas shall have a minimum width of 5 feet.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 6 of 19
D_NW_Gourmet_Freezer_190108
Staff Comment: The proposal does not meet any landscaping applicability criteria.
Therefore, parking lot landscaping is not required as part of this project. However,
street trees shall be required along SW 7th Street in the existing planter strip. The
applicant proposes to plant three (3) blaze maple street trees. Staff recommends that
a different tree species be selected. The proposed blaze maple tree is classified as a
large tree on the City of Renton approved tree list. Large trees planted in equivalently
sized landscape strips on adjacent properties have caused recurring damage to
sidewalks due to uprooting. Staff recommends planting Ginkgo trees, a medium tree on
the City’s street tree list, instead of the blaze maples or a different medium species
approved by the Current Planning Project Manager.
Tree Retention: The City’s adopted Tree Retention and Land Clearing Regulations (4-4-
130) require the retention of 10 percent of trees in a commercial development.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy;
significant trees on slopes greater than twenty percent (20%); significant trees adjacent
to critical areas and their associated buffers; and significant trees over sixty feet (60')
in height or greater than eighteen inches ( 18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved;
other significant native evergreen or deciduous trees; and other significant non-native
trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have
been evaluated for retention and are not able to be retained, unless the alders and/ or
cottonwoods are used as part of an approved enhancement project within a critical
area or its buffer.
Staff Comment: No trees are proposed to be removed.
Compliant if
condition of
approval is
met
Screening: All on-site surface mounted utility equipment shall be screened from public
view. Screening shall consist of equipment cabinets enclosing the utility equipment,
solid fencing or a wall of a height at least as high as the equipment it screens, or a
landscaped visual barrier allowing for reasonable access to equipment. Equipment
cabinets, fencing, and walls shall be made of materials and/or colors compatible with
building materials. All operating equipment located on the roof of any building shall be
enclosed so as to be screened from public view.
Staff Comment: The applicant proposes an 8-foot tall chain link fence with slats to
screen all surface mounted utility equipment from public view. The City of Renton
municipal code requires that all surface mounted equipment be screened from view and
requires that the fence be compatible in terms of material and color with the proposed
and existing structures. A chain link fence would not constitute a solid fence. In addition
to slats, the fence would require additional design elements to ensure it has a pleasing
aesthetic, is compatible with existing structures and landscaping, and creates a solid
barrier between the public realm and the proposed HVAC equipment. Staff recommends
that landscaping, such as an evergreen hedge or evergreen bushes, be provided in front
of the proposed fence to create a solid, aesthetically pleasing barrier. Alternatively, the
applicant may propose a solid fence, such as painted cedar, to match the proposed
structure. Sufficient information shall be provided with the building permit submittal,
as determined by the Current Planning Project Manager, to ensure all equipment is fully
screened and the fence is materially compatible with the existing structure.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 7 of 19
D_NW_Gourmet_Freezer_190108
Compliant if
condition of
approval is
met
Refuse and Recycling: In manufacturing and other nonresidential developments, a
minimum of three (3) square feet per every one thousand (1,000) square feet of
building gross floor area shall be provided for recyclables deposit areas and a minimum
of six (6) square feet per one thousand (1,000) square feet of building gross floor area
shall be provided for refuse deposit areas. A total minimum area of one hundred (100)
square feet shall be provided for recycling and refuse deposit areas.
Staff Comment: Including the proposed addition, the total gross floor area of the
warehouse would be 73,172 sq. ft., requiring 220 square feet of recyclables deposit
areas, and 440 square feet of refuse deposit areas, for a total area of 660 sq. ft. The
submitted site plan identifies a new 525 sq. ft. trash enclosure at the NW corner of the
existing warehouse, 135 sq. ft. less than required. Staff recommends as a conditions of
approval that an update site plan is provided with the building permit application that
identifies an additional 135 sq. ft. of area to meet minimum refuse and recycling
requirements, unless a modification to these standards is applied for and approved. The
site plan does not differentiate between refuse and recycling space. This differentiation
would need to be included as part of the building permit submittal to ensure compliance
with refuse and recycling standards.
The trash enclosure will be screened by an 8-foot tall chain link fence with slats to screen
the enclosure from public view. The enclosure is positioned at the back of the site
screened from the north by dense vegetation, from the east by the existing warehouse,
and from the south by the large storage tanks and four foot security wall. The existing
landscaping and buildings provided sufficient screening for the refuse and recycling
facility.
Parking: Parking regulations for Warehouses and indoor storage buildings require that
a minimum and maximum of 1 parking space per 1,500 square feet of net floor area be
provided. The number of bicycle parking spaces shall be equal to ten percent (10%) of
the number of required off-street vehicle parking spaces.
Standard parking stall dimensions are 9 feet by 20 feet, compact stall dimensions are 8
½ feet by 16 feet. Compact spaces are not to exceed thirty percent (30%) of required
parking spaces.
Staff Comment: The proposed addition does not meet the applicability criteria for
parking, loading and driveway regulations and therefore no change is required.
15. Critical Areas: Project sites which contain critical areas are required to comply with the Critical Areas
Regulations (RMC 4-3-050). The proposal is consistent with the Critical Areas Regulations, if all
conditions of approval are complied with:
Compliance Critical Areas Analysis
Compliant if
condition of
approval is
met
High Seismic Hazard Areas: Based upon the results of a geotechnical report and/or
independent review, conditions of approval for developments may include buffers
and/or setbacks from buffers.
Staff Comment: A Geotechnical Report, prepared by Migizi Group, Inc. was submitted
with the proposal, dated July 27th, 2018 (Exhibit 7). Subsurface exploration was
conducted which included drilling three (3) hollow stem auger borings from a truck
mounted rig, labeled B-1 (30.1 feet in depth), B-2 (30.2 feet in depth), and B-3 (31.0 feet
in depth). An engineering geologist from Migizi Group continuously observed the
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 8 of 19
D_NW_Gourmet_Freezer_190108
borings, logged the subsurface conditions, and collected soil samples. All sampled were
stored in watertight containers and later transported to a laboratory for further visual
examination. After the borings were completed they were backfilled with bentonite
chips.
Throughout the drilled operation, soil samples were obtained at 2.5 or 5.0-foot depth
intervals by means of the Standard Penetration Test (SPT) per ASTM:D-1586. This
testing and sampling procedure consists of driving a standard 2-inch-diamter steel spill-
spoon samples 18 inches into the soil with a 140-pound hammer free-falling 30 inches.
The number of blows required to drive the sampler through each 6-inch interval is
counted and the total number of blows struck during the final 12 inches is recorded as
the Standard Penetration Resistance. If a total of 50 blows are struck within any 6-inch
interval, the driving is stopped and the blow count is recorded as 50 blows for the actual
penetration distance. The resulting Standard Penetration Resistance values indicate the
relative density of granular soils and the relative consistency of cohesive soil.
All three auger borings were conducted east of the southern part of the existing
warehouse in the footprint of the proposed freezer addition. In each of these borings
the geologists encountered roughly 8 inches of asphalt overlaying 6 to 18 inches of fill
comprised of medium dense crushed rock base, course and gravelly sand with varying
amounts of silt. Underlining the fill layer they encountered native soils comprised of
either soft silt and silty sand, or coarser sands containing varying amounts of gravel.
Soil mottling was observed at 5 feet in boring B-3. In borings B-2 and B-3, grain size and
gravel content tended to increase with depth until reaching glacial till at depths of 28
feet and 30.5 feet, respectively. In boring B-1, a layer of loose silty sand bearing
abundant organics was encountered from 20.5 feet to 23 feet beneath an 8.5 foot thick
unit of medium-dense sand with gravel.
The site is relatively flat with only a slight variation in grade. Vegetation is limited to
ornamental trees and landscaped grassy areas on the south half of the site. No surface
water or hydrologic features were observed on the site such as seeps, springs, ponds,
or streams, nor were surface expressions of groundwater observed. Groundwater was
identified at a depth of 8 to 9 feet in each boring. However, drilling through silt-rich soil
can often mask the actual depth of groundwater and it is likely that the actual depth is
somewhat shallower. It is the opinion of Migizi Group Inc. that seasonally high
groundwater could raise as high as 5 feet below the subsurface. Soil conditions are
slowly permeable to relatively impermeable glacial till soils at shallow depths. Due to
these soil conditions, ground water should be diverted to the existing on-site storm
system since infiltration will not be feasible for this project.
Based on the analysis done by Migizi Group Inc., the on-site soil conditions generally
correspond to a Class E site, as defined by the international building code. Liquefaction
is a sudden increase in pore water pressure and a sudden loss of soil shear strength
caused by shear strains, as could be a result of an earthquake. Saturated loose sands
with fine (silt and clay) content less than approximately 20% are more susceptible to
liquefaction, but very loose silt can liquefy under severe seismic conditions. Based on
the previous report issued by E3RA on May 22, 2013 loose saturated soil samples were
collected at a depth of 10 to 11.5 feet below the footprint of the oil storage tanks. These
samples contained 21% silt, 76% fine sand, and a small amount of coarser sand and
gravel. Based on these finding soils underlying the site could liquefy during a severe
seismic event, especially when groundwater is seasonally high. In order to address soil
and liquefaction conditions within the proposed expansion area, and limit settlement
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 9 of 19
D_NW_Gourmet_Freezer_190108
of the addition and new settlement of the existing structure, Migizi Group, Inc.
recommends that all foundation elements and the floor slabs be supported by auger
cast piles. Project construction shall comply with all recommendations outlined in the
geotechnical report prepared by Migizi Group, Inc., dated July 27th, 2018.
16. Site Plan Review: Pursuant to RMC 4-9-200.B, Site Plan Review is required for development in the IM
zoning classification when it is not exempt from Environmental (SEPA) Review. For Master Plan
applications compliance with the review criteria for Site Plans are analyzed at a general level of detail to
ensure nothing would preclude the development of the Site Plan. Given Site Plan applications are
evaluated for compliance with the specific requirements of the RMC 4-9-200.E.3 the following table
contains project elements intended to comply with level of detail needed for Site Plan requests. The
proposal is consistent with the Site Plan Review criteria, if all conditions of approval are complied with:
Compliance Site Plan Criteria and Analysis
a. Comprehensive Plan Compliance and Consistency.
Staff Comment: See previous discussion under FOF 13, Comprehensive Plan Analysis.
Compliant if
conditions of
approval are
met
b. Zoning Compliance and Consistency.
Staff Comment: See discussion under FOF 14, Zoning Development Standard
Compliance.
N/A c. Design Regulation Compliance and Consistency.
N/A d. Planned action ordinance and Development agreement Compliance and
Consistency.
Compliant if
conditions of
approval are
met
e. Off-site Impacts.
Structures: Restricting overscale structures and overconcentration of development
on a particular portion of the site.
Staff Comment: The IM zone has no maximum height, and no side or rear setback.
Despite this, development should not be overscale or be over concentrated on one
portion of the site. Expansion of the warehouse originally constructed in 1971 has been
incremental and balanced across this 5 acre site. The first expansion, an office, is
located on the south side of the structure. The second expansion, six (6) tanks for the
storage of vegetable oil, is located on the west side of the building. The current project
proposes to construct a freezer on the east side of the building. The proposed addition
does not exceed the height of the existing structure and occupies less than 50% of
eastern façade of the existing structure. The 6,386 square foot addition would only
increase the existing 66,786 square foot structure by 9.6%. As designed, the freezer
addition does not over-concentrate development on any particular portion of the site,
nor is it overscale when considering the size of the existing development.
Circulation: Providing desirable transitions and linkages between uses, streets,
walkways and adjacent properties.
Staff Comment: No change is proposed to international circulation as part of this
project. The current circulation route appears to be safe and efficient for all users.
Utilities, Loading and Storage Areas: Locating, designing and screening storage
areas, utilities, rooftop equipment, loading areas, and refuse and recyclables to
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 10 of 19
D_NW_Gourmet_Freezer_190108
minimize views from surrounding properties. Locate utilities underground
consistent with RMC 4-6-090.
Staff Comment: All storage will be placed inside of the proposed freezer addition. No
outdoor storage is anticipated as part of the project. All equipment will be screened as
detailed in FOF 14, Zoning Development Standard: Screening and Refuse and Recycling.
Existing loading bays in the northeastern corner of the site will be screened by the
proposed addition from public view. The new structure will be sited south of the existing
loading bays entirely blocking the bays from pedestrian view from the street. Property
to the east and west are industrialized and not conducive to pedestrian foot traffic along
their respective western and eastern lot lines. From the north, dense vegetation and the
rail corridor screen the bays.
Views: Recognizing the public benefit and desirability of maintaining visual
accessibility to attractive natural features.
Staff Comment: The site itself, and the surrounding area, have been industrialized for
decades and have few natural features. The only remaining vegetation is ornamental
trees, manicured grass, and dense trees to the north of the structure adjacent to the rail
corridor (See FOF 16, Structure Scale).
Landscaping: Using landscaping to provide transitions between development and
surrounding properties to reduce noise and glare, maintain privacy, and generally
enhance the appearance of the project.
Staff Comment: The project site currently houses 10 mature trees, and dense vegetation
behind the existing warehouse along the railroad tracks. The retention of these mature
trees, as well as the addition of three street trees will serve as a visual barrier between
the public right-of-way (ROW) and the industrial use of the property. The expansive
yard, and existing planter strips within the parking lot serve to further screen the site,
and block noise and reduce glare caused by vehicle traffic on the site.
Lighting: Designing and/or placing exterior lighting and glazing in order to avoid
excessive brightness or glare to adjacent properties and streets.
Staff Comment: A lighting plan was not provided with the application; therefore staff
recommended that a lighting plan be provided at the time of building permit review, if
new lights are proposed as a part of the freezer addition.
Compliant if
condition of
approval is
met
f. On-site Impacts.
Structure Placement: Provisions for privacy and noise reduction by building
placement, spacing and orientation.
Staff Comment: The proposed freezer would eliminate the necessity for fork lifts to exit
the warehouse and load/unload refrigerated trucks in the existing loading dock. All
noise previously created by the process of hauling food materials to and from the
loading dock would be entirely self-contained within the proposed freezer. The
orientation of the freezer would create a 30-foot setback from the property line and
screen the loading bay behind the addition. This would leave ample travel space for
trucks to access the rear loading bays. It would also serve as a physical barrier to reduce
noise caused by the three (3) remaining exterior loading bays. Since the site is bordered
by industrial uses and railroad tracks, the group most effected by such noise would be
pedestrians and cyclists traveling down SW 7th Street. The positioning of the building
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 11 of 19
D_NW_Gourmet_Freezer_190108
would block substantially more noise from reaching the pedestrian space than the
current open air configuration.
Structure Scale: Consideration of the scale of proposed structures in relation to
natural characteristics, views and vistas, site amenities, sunlight, prevailing winds,
and pedestrian and vehicle needs.
Staff Comment: The scale is appropriate for the intended purpose of the freezer and
previous development on the site, but is anticipated have impacts on views and vistas.
The freezer is proposed on the eastern side of the existing structure, sited on top of an
existing loading dock, but is otherwise undeveloped above ground level. This creates a
vista along the eastern side of the property which extends across the rail corridor
bordering the northern property line, and terminates at a tree line screening the rail
corridor from the single family homes built further north. The freezer is proposed to
terminate this vista at the midpoint of the property, restricting the pedestrian/cyclist
viewshed to the southern wall of the freezer addition. The City of Renton plans to
construct a shared pedestrian/bicycle path along SW 7th Street, which is likely to
increase traffic along the route and further exacerbate the visual impact. Staff
recommends that the addition be architecturally compatible with the existing
warehouse, in terms of material and color, to create a cohesive aesthetic that will draw
less attention from pedestrians on and adjacent to the site, mitigating the impact of the
proposed development.
The addition is not anticipated to affect sunlight, prevailing winds or site amenities. The
addition constitutes less than a 10% increase in size to the existing warehouse and
reserves a 30-foot setback along the eastern side of the lot for vehicular travel.
Pedestrians would access the addition internally from the south eastern portion of the
site, through the office. The scale of the addition is not anticipated to impede this
movement.
Natural Features: Protection of the natural landscape by retaining existing
vegetation and soils, using topography to reduce undue cutting and filling, and
limiting impervious surfaces.
Staff Comment: No cut and fill is proposed as part of this project. Existing impervious
surface will be replaced to construct the proposed addition. No new impervious surface
will be added as part of this project.
Reducing Parking Impervious Areas: Design parking areas to minimize impervious
surfaces, including but not limited to: (1) breaking up parking areas and directing
stormwater flows to multiple low impact development features such as bio-
retention areas; (2) locating parking near trees to provide storm water uptake; (3)
retaining or adding vegetation to parking areas; (4) placing existing parking that
exceeds maximum parking ratios in permeable pavement designed consistent with
the Surface Water Design Manual in RMC 4-6-030; and (5) using other low impact
development techniques consistent with RMC 4-6-030
Staff Comment: The existing parking area contains a landscape strip, and two
landscaped islands to break up impervious surface coverage. No changes are proposed
to the parking area as part of this project.
Landscaping: Use of landscaping to soften the appearance of parking areas, to
provide shade and privacy where needed, to define and enhance open spaces, and
generally to enhance the appearance of the project. Landscaping also includes the
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 12 of 19
D_NW_Gourmet_Freezer_190108
design and protection of planting areas so that they are less susceptible to damage
from vehicles or pedestrian movements.
Staff Comment: See FOF 14, Zoning Development Standard: Landscaping.
g. Access and Circulation.
Location and Consolidation: Providing access points on side streets or frontage
streets rather than directly onto arterial streets and consolidation of ingress and
egress points on the site and, when feasible, with adjacent properties.
Staff Comment: Access is currenlty provided off of SW 7th Street with three curb cuts to
the site. SW 7th street is considered a minor arterial street. Two cuts are located on the
west portion of the site used to access the surface parking lot and the main building
entrance, the third is located on the east edge of the site providing access to the loading
docks. Based on the existing site layout and the parking lot design removal of any one
curb cut is not feasible or pratical at this time as no changes are proposed to the surface
parking lot. However, the consolidation of the most eastelry curb cut would be feasable
with the property to the east (Harper Engineering. Consolidation of these two driveways
should be considered when updated frontage improvments are installed along SW 7th
Street. The site does not front any other roads, and abuts railroad ROWs to the north
and east.
Internal Circulation: Promoting safety and efficiency of the internal circulation
system, including the location, design and dimensions of vehicular and pedestrian
access points, drives, parking, turnarounds, walkways, bikeways, and emergency
access ways.
Staff Comment: No change is proposed to internal circulation as part of this project. The
current circulation route appears to be safe and efficient for all users.
Loading and Delivery: Separating loading and delivery areas from parking and
pedestrian areas.
Staff Comment: Loading and delivery would continue on the northeast corner of the
structure behind the proposed addition. Three (3) loading bays will remain on the
exterior of the structure. Two (2) loading bays will be converted to internal connections
between the freezer and the warehouse. All parking and pedestrian areas are to remain
at the SW corner of the site, separated from the loading bays by landscaping, the office,
warehouse, and freezer.
Transit and Bicycles: Providing transit, carpools and bicycle facilities and access.
Staff Comment: The proposed addition does not meet the applicability criteria for
parking, loading and driveway regulations and therefore no change is required.
Pedestrians: Providing safe and attractive pedestrian connections between parking
areas, buildings, public sidewalks and adjacent properties.
Staff Comment: The property is developed with sidewalks to and from the
administrative office on the site that connect pedestrians to the parking lot on the
western portion of the site. The sidewalks and landscaping surrounding these
pedestrian connections are well maintained and include flowers, shrubs and trees. The
parking lot contains two (2) landscaped islands containing well maintained grass and
trees. No clear pedestrian path exists to the sidewalk from the office, but the office
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 13 of 19
D_NW_Gourmet_Freezer_190108
employs very few employees and the site and surrounding are industrial in nature and
do not attract significant foot traffic.
h. Open Space: Incorporating open spaces to serve as distinctive project focal points
and to provide adequate areas for passive and active recreation by the
occupants/users of the site.
Staff Comment: The entire SE portion of the site contains an expansive lawn. This area
could be utilized by employees as recreation space if desired. This space is broken up by
island of trees, shrubs, flowers, and bushes that serve as focal points and draw attention
away from the industrial nature of the site.
i. Views and Public Access: When possible, providing view corridors to shorelines and
Mt. Rainier, and incorporating public access to shorelines
Staff Comment: The proposed structure would not block view corridors to shorelines or
Mt. Rainier. The public access requirement is not applicable to the proposal.
j. Natural Systems: Arranging project elements to protect existing natural systems
where applicable.
Staff Comment: The site itself, and the surrounding area, have been industrialized
for decades and have few natural features. The only remaining vegetation is
ornamental trees, manicured grass, and dense trees to the north of the structure
adjacent to the rail corridor (See FOF 16, Structure Scale).
Compliant if
conditions of
approval are
met
k. Services and Infrastructure: Making available public services and facilities to
accommodate the proposed use:
Police and Fire.
Staff Comment: Police and Fire Prevention staff indicated that sufficient resources exist
to furnish services to the proposed development; if the applicant provides Code required
improvements and fees.
Water and Sewer.
Staff Comment: The proposed development is within the City’s water service area and
in the Valley 196 Pressure Zone. There is an existing 12-inch water main located on SW
7th Street. The water main can deliver a maximum flow rate of 1,800 gpm. The static
water pressure is about 74 psi at elevation 24 feet. There is an existing 4-inch domestic
water meter and an 8-inch fire sprinkler supply line with an approved DDCVA located in
the building. The domestic water meter has a 4-inch RPBA located inside the building.
The site is located outside of an Aquifer Protection Area.
A grease Interceptor is required for the project and is shown on the Utility Plan
submitted with the project application. The grease interceptor shall be sized based on
drainage fixture units in accordance with standards found in the latest edition of the
Uniform Plumbing Code (UPC). The grease interceptor shall drain by gravity to the sewer
main. The grease interceptor shall be located on-site so that is accessible for routine
maintenance and be a minimum of 1500 gallons. The applicant shall have King County
Industrial Waste review and approve the addition to ensure they are in compliance with
their existing industrial waste permit with King County. If there are any modifications
or additions to the grease interceptor, the applicant will need to obtain a permit
through the City of Renton.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 14 of 19
D_NW_Gourmet_Freezer_190108
Drainage.
Staff Comment: The proposal will continue to use the existing storm drain system on
site, which collects all water and conveys to the City’s regional stormwater system
located in SW 7th Street. The site falls within the City’s Flow Control Standard (Exist
Peak), and is within the Black River drainage basin. An existing Filterra unit located
offsite is used to provide treatment before discharging into the Black River,
approximately 0.50 miles downstream from the site. The proposed building addition will
be located entirely on what is currently an impervious loading dock. Stormwater runoff
from the building roof will discharge onto splash blocks and will be collected by the
existing private storm drainage system. The proposed 300 square foot compressor pad
to the south of the building addition will utilize basic dispersion, using sheet flow or
splash blocks to discharge into the existing lawn area to the south.
Transportation.
Staff Comment: Access to the site is provided via SW 7th Street, a minor arterial street
with an available ROW width of 80 feet. The applicant did not provide a transportation
study because the proposal is not anticipated to generate any new peak hour trips. The
proposal reduces the total number of loading bays, and lowers capacity for trip
generation. Further, the addition does not provide any new service that is not already
offered on site, creating no net demand increase. It is anticipated that there may be
temporary impacts to traffic as a result of construction.
The applicant is proposing to conform to a modified minor arterial street standard along
SW 7th Street through a requested street modification from RMC 4-6-060. The applicant
proposes to maintain existing frontage improvements, contending that neighboring
properties were built with compatible improvements and new improvements would be
out of character for the area. See FOF 17, Street Modification Analysis.
N/A l. Phasing: The applicant is not requesting any additional phasing.
m. Stormwater: Providing optimal locations of stormwater infiltrating low impact
development facilities. Avoiding placement of buildings or impervious areas on
soils with infiltration capability to the maximum extent practicable.
Staff Comment: A preliminary Drainage Plan and Technical Information Report (TIR),
dated September 4, 2018, was submitted by AHBL with the Land Use Application. Based
on the City of Renton’s flow control map, the site falls under Flow Control Duration
Standards (Existing Peak Conditions) and is located within the Black River drainage
basin. The development is subject to a Full Drainage Review in accordance with the 2017
Renton Surface Water Design Manual (RSWDM). All nine core requirements and the six
special requirements have been discussed in the Technical Information Report. The
detention, water quality and conveyance shall be designed in accordance with the
RSWDM that is current at the time of the civil construction permit application. The
applicant has proposed to use basic dispersion for the new roof runoff area. See
Advisory Notes to Applicant (Exhibit 13) for more detailed storm water comments.
17. Street Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4-9-250D, the applicant is
requesting an Administrative Modification from RMC 4-6-060F.2 to maintain existing frontage
improvements along SW 7th Street and not install new frontage improvements. The proposal is
compliant with the following modification criteria, pursuant to 4-9-250D, if all conditions of approval
are met:
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 15 of 19
D_NW_Gourmet_Freezer_190108
Compliance Street Modification Criteria and Analysis
a. Substantially implements the policy direction of the policies and objectives of the
Comprehensive Plan Land Use Element and the Community Design Element and the
proposed modification is the minimum adjustment necessary to implement these
policies and objectives.
Staff Comment: The Community Design Element has applicable policies listed under
“Promoting a Safe, Healthy, and Attractive Community”. These policies address
walkable neighborhoods, safety, and shared uses. The intent of the policies are to
promote new development with walkable places that support grid and flexible grid
street and pathway patterns, and are visually attractive, safe, and healthy
environments. The requested street modification is consistent with these policy
guidelines.
b. Will meet the objectives and safety, function, appearance, environmental
protection, and maintainability intended by the Code requirements, based upon
sound engineering judgment.
Staff Comment: The City’s Public Works Transportation section and Economic
Development section have reviewed SW 7th St and the surrounding area and are
recommending that a modified minor arterial street section is more suitable for the
portion of SW 7th Street adjacent to the site. This recommendation is based on the fact
that the existing roadway width will meet the transportation needs of the surrounding
area while providing the required separation between the vehicular and pedestrian
travel ways, noting that this roadway has been identified on the trails and bicycle
master plan as a shared use path.
The modified minor arterial street standard has a ROW width of 91 feet. The existing
paved roadway width is 48 feet, consisting of four (4) 12-foot wide travel lanes with a
0.5-foot wide curb on both sides. Beyond the existing curb line the street section shall
include, an 8-foot wide planter and a 12-foot wide shared use path with a 1.5-feet clear
zone at back of sidewalk, along north side of the pavement. Therefore, a dedication
behind the curb is necessary to help ensure future bicycle path improvements can be
achieved. The ROW dedication shall be measured 21.5 feet from the existing back of
curb. Staff recommends that the applicant maintain a pavement width of 48-feet, add
three (3) street trees in front of the existing landscape strip and maintain the existing
sidewalk in order to provide safe and expedited traffic movements from the SW 7th St
onto the site.
c. Will not be injurious to other property(ies) in the vicinity.
Staff Comment: See comments under criterion ‘b’.
d. Conforms to the intent and purpose of the Code.
Staff Comment: See comments under criterion ‘b’.
e. Can be shown to be justified and required for the use and situation intended; and
Staff Comment: See comments under criterion ‘b’.
f. Will not create adverse impacts to other property(ies) in the vicinity.
Staff Comment: See comments under criterion ‘b’.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 16 of 19
D_NW_Gourmet_Freezer_190108
18. Waiver Modification Analysis: Pursuant to Renton Municipal Code (RMC) 4-9-250C, the applicant is
requesting a waiver of the installation of street improvements along SW 7th Street. Waiver applications
may be granted subject to the determination that there is reasonable justification for such a waiver. In
order to grant a waiver request the applicant shall show reasonable justification that the following
criteria are satisfied or are not applicable to the subject property. In no case shall a waiver be granted
that is detrimental to public health, safety, or welfare. The proposal is compliant with the following
waiver criteria, pursuant to 4-9-250C, if all conditions of approval are met:
Compliance Street Modification Criteria and Analysis
N/A
a. Required street improvements will alter an existing wetlands or stream, or have a
negative impact on a shoreline’s area.
Staff Analysis: There are no wetlands or streams along SW 7th St.
N/A
b. Existing steep topography would make required street improvements infeasible.
Staff Analysis: There are no identified steep slopes along the property frontage.
c. Required street improvements would have a negative impact on other properties,
such as restricting available access.
Staff Analysis: Installation of frontage improvements along SW 7th Street would require
the applicant to remove existing sidewalks and install new sidewalks along the
frontage. At this time, the City of Renton has not finalized the final design for the shared
use trail. If the applicant were to construct the improvements without the final design
in place there is a high possibility that they will need to be replaced, which would have
a significant impact to the pedestrian and vehicle traffic in the area.
d. There are no similar improvements in the vicinity and there is little likelihood that
the improvements will be needed or required in the next ten (10) years.
Staff Analysis: There is an existing 8-foot planter and a 5-foot wide sidewalk along both
sides of SW 7th Street behind the existing 0.5-foot curb. SW 7th Street is not included in
the City’s current TIP plan for roadway widening or improvements. Therefore, it is
unlikely that improvements will be needed in the next ten years.
e. In no case shall a waiver be granted unless it is shown that there will be no
detrimental effect on the public health, safety or welfare if the improvements are
not installed, and that the improvements are not needed for current or future
development.
Staff Analysis: Existing pavement width and existing pedestrian sidewalks and
pathways provide for safe vehicular and pedestrian travel. The waiver will therefore
maintain a safe and healthy public environment and will not be detrimental to the
public.
f. Will not create adverse impacts to other property(ies) in the vicinity.
Staff Comment: See comments under criterion ‘c’.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 17 of 19
D_NW_Gourmet_Freezer_190108
I. CONCLUSIONS:
1. The subject site is located in the Employment Area (EA) Comprehensive Plan designation and complies
with the goals and policies established with this designation, see FOF 13.
2. The subject site is located in the Medium Industrial (IM) zoning designation and complies with the zoning
and development standards established with this designation provided the applicant complies with City
Code and conditions of approval, see FOF 14.
3. The proposed addition complies with the Critical Areas Regulations provided the applicant complies with
City Code and conditions of approval, see FOF 15.
4. The proposed addition complies with the Site Plan Review Criteria provided the applicant complies with
City Code and conditions of approval, see FOF 16.
5. There are adequate public services and facilities to accommodate the proposed addition, see FOF 16.
6. The proposed site plan complies with the Street Modification criteria as established by City Code and
state law provided all advisory notes and conditions are complied with, see FOF 17.
7. The proposed site plan complies with the Waiver Modification criteria as established by City Code and
provided all advisory notes and conditions are complied with, see FOF 18.
J. DECISION:
The NW Gourmet Freezer Addition Site Plan Review, File No. LUA18-000667, SA-A, as depicted in Exhibit 3, is
approved and is subject to the following conditions:
1. The applicant shall submit, with the building permit application, a revised landscape plan showing three
(3) Gingko trees, or a species approved by the Current Planning Project Manager, or included in the City
of Renton approved tree list under small or medium trees. The revised plan shall be reviewed and
approved by the Current Planning Project Manager prior to building permit issuance.
2. The applicant shall submit, with the building permit application, a revised site plan, landscaping plan
and revised elevation drawings showing proposed revisions screening for all mechanical equipment.
The revised plans shall be reviewed and approved by the Current Planning Project Manager prior to
building permit issuance.
3. Project construction shall comply with all recommendations outlined in the geotechnical report
prepared by Migizi Group, Inc., dated July 27th, 2018.
4. The applicant shall submit, with the building permit application, a Lighting Plan with the building permit
application, if any new lighting is proposed as part of the building permit application. The plan shall be
reviewed and approved by the Current Planning Project Manager prior to building permit issuance.
5. The applicant shall submit, with the building permit application, a revised site plan demonstrating
compliance with refuse and recycling standards. The plan shall differentiate between area reserved for
refuse, and area reserved for recycling and show an increase of 135 sq. feet to meet refuse and
recycling standards, unless a modification to these standards is applied for and approved. The revised
plan shall be reviewed and approved by the Current Planning Project Manager prior to building permit
issuance.
6. The applicant shall submit, with the building permit application, revised elevation drawings showing
that the proposed freezer addition is architecturally compatible with the existing warehouse in terms of
material, and color. The revised drawings shall be reviewed and approved by the Current Planning
Project Manager prior to building permit issuance.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 18 of 19
D_NW_Gourmet_Freezer_190108
7. The applicant shall submit, with the building permit application, evidence of project approval by King
County Industrial Waste to ensure they are in compliance with their existing industrial waste permit. If
there are any modifications or additions to the grease interceptor, the applicant will need to obtain a
permit through the City of Renton. King County Industrial Waste approval shall be verified, and any
revised plans shall be reviewed and approved by the Project Plan Reviewer prior to building permit
issuance.
DATE OF DECISION ON LAND USE ACTION:
SIGNATURE:
Jennifer Henning, Planning Director Date
TRANSMITTED on January 8, 2019 to the Owner/Applicant/Contact:
Owner: Mike Gilroy Applicant: Mike Gilroy Contact: James Carlton
600 SW 7th Street,
Renton, WA 98057
600 SW 7th Street,
Renton, WA 98057
Tahoma Design Group2215 N.
30th Street, Tacoma, WA 98402
TRANSMITTED on January 8, 2019 to the Parties of Record:
None
TRANSMITTED on January 8, 2019 to the following:
Chip Vincent, CED Administrator
Brianne Bannwarth, Development Engineering Manager
Amanda Askren, Property Services
Vanessa Dolbee, Current Planning Manager
Rick Marshall, Fire Marshal
K. LAND USE ACTION APPEALS, REQUEST FOR RECONSIDERATION, & EXPIRATION:
The administrative land use decision will become final if the decision is not appealed within 14 days of the
decision date.
APPEAL: This administrative land use decision will become final if not appealed in writing to the Hearing
Examiner on or before 5:00 PM on January 22, 2019. An appeal of the decision must be filed within the 14-
day appeal period (RCW 43.21.C.075(3); WAC 197-11-680), together with the required fee to the Hearing
Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057. RMC 4-8-110.B governs appeals to the
Hearing Examiner and additional information regarding the appeal process may be obtained from the City
Clerk’s Office, (425) 430-6510.
EXPIRATION: The Administrative Site Development Plan Review decision will expire two (2) years from the date
of decision. A single two (2) year extension may be requested pursuant to RMC 4-9-200.
EXPIRATION: The Modification decision will expire two (2) years from the date of decision. A single one (1) year
extension may be requested pursuant to RMC 4-9-250.
City of Renton Department of Community & Economic Development
NW Gourmet Freezer Addition
Administrative Report & Decision
LUA18-000667, SA-A
Report of January 8, 2019 Page 19 of 19
D_NW_Gourmet_Freezer_190108
RECONSIDERATION: Within 14 days of the decision date, any party may request that the decision be reopened
by the approval body. The approval body may modify his decision if material evidence not readily discoverable
prior to the original decision is found or if he finds there was misrepresentation of fact. After review of the
reconsideration request, if the approval body finds sufficient evidence to amend the original decision, there will
be no further extension of the appeal period. Any person wishing to take further action must file a formal
appeal within the 14-day appeal time frame.
THE APPEARANCE OF FAIRNESS DOCTRINE: provides that no ex parte (private one-on-one) communications
may occur concerning the land use decision. The Doctrine applies not only to the initial decision, but to Appeals
to the Hearing Examiner as well. All communications after the decision/approval date must be made in writing
through the Hearing Examiner. All communications are public record and this permits all interested parties to
know the contents of the communication and would allow them to openly rebut the evidence in writing. Any
violation of this doctrine could result in the invalidation of the appeal by the Court.
CITY OF RENTON
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT
ADMINISTRATIVE REPORT & DECISION
EXHIBITS
Project Name:
NW Gourmet Freezer Addition
Land Use File Number:
LUA18-000667, SA-A
Date of Report
January 8, 2019
Staff Contact
Jeffrey Taylor
Assistant Planner
Project Contact/Applicant
James Carlton
Tahoma Design Group
2215 N. 30th Street, Tacoma,
WA 98402
Project Location
600 SW 7th Street,
Renton, WA 98057
The following exhibits are included:
Exhibits 1-7: As shown in the SEPA Addendum prepared by City of Renton, dated December 10, 2018
Exhibit 8: Administrative Report and Decision
Exhibit 9: Landscape Plan
Exhibit 10: Architectural Elevations
Exhibit 11: Technical Information Report (TIR), prepared by AHBL, dated September 4, 2018
Exhibit 12: Applicant’s SEPA Addendum Request and Justification
Exhibit 13: Advisory Notes to the Applicant
IN COMPLIANCE WITH CITY OF RENTON STANDARDSCivil EngineersStructural EngineersLandscape ArchitectsCommunity PlannersNatural Resource EcologistsLand SurveyorsNeighborsT A C O M A2215 North 30th Street, Suite 300 Tacoma, WA 98403253.383.2422TEL253.383.2572FAXwww.ahbl.comWEBS E A T T L ES P O K A N E T R I - C I T I E S NORTHWEST GOURMET FREEZER ADDITIONAHBL JOB #2180100.10PLANTING PLANKnow what'sbelow.before you dig.CallRTED-40-4018
C:-LUA:-PR:-R-40180L A NDSCAPEA
R C
H ITECT11/1/2018CRAIGD
. ANDERSE N
NO.1005EXP.0
3 /1 4 /2020GRAPHIC SCALE030601" = 30 FEET15CONTRACTOR SHALL ADJUST EXISTING IRRIGATION SYSTEM IN PLANTING STRIP TOACCOMMODATE STREET TREE PLANTING.IRRIGATION NOTESW 7TH STREETEXISTING BUILDINGPROPOSED ADDITIONEXISTING PARKINGEXISTING TREE (TYP)EXISTING TURFUTILITIES AND LIGHT POLEPRECLUDE ADDITIONAL STREETTREESUTILITIES AND LIGHT POLEPRECLUDE ADDITIONAL STREETTREESTREESBOTANICAL NAMECOMMON NAMECONTQTYACER X FREEMANII `JEFFSRED` AUTUMN BLAZE MAPLE 1.5" CAL 3PLANT SCHEDULENOTES:1. ALIGN STAKES PERPENDICULAR OR PARALLEL TO CURB & SIDEWALK,WHICHEVER IS CLOSER TO WIND DIRECTION.2. SEE PLANTING NOTES & SPECIFICATIONS (IF PROVIDED) FOR MOREINFORMATIONWIND DIRECTIONPLAN5' MIN.2' MIN."CHAIN-LOCK" RUBBER GUYTIES OR APPROVED EQUAL.2X2 HARDWOOD STAKES. DRIVESTAKE OUTSIDE OF ROOTBALL.(2) STAKES PER TREE.TREE TRUNKGUYLINESTAKEMULCH. DO NOT PLACE MULCHAGAINST TRUNK.ROOT BALLDECIDUOUS TREE PLANTINGNTS3"-4" HIGH WATERING RINGDIG PIT SHALLOW AND WIDE3X ROOTBALL DIA.1P-216-0966-11FINISH GRADE AT LAWN AREAOR PLANTING BED.REMOVE EXCESS SOIL THAT MAYHAVE ACCUMULATED ABOVE THETRUNK FLARE PRIOR TO DIGGINGAT NURSERY.TRUNK FLARE (SET AT 1" ABOVEFINISHED GRADE)PRUNE ANY GIRDLING ORADVENTITIOUS ROOTS PRIOR TOBACKFILLING.REMOVE WIRE BASKET (NOEXCEPTIONS) AND ANY OTHERSYNTHETIC MATERIAL FROMROOTBALL. CUT BACK AND REMOVEBURLAP FROM TOP AND SIDE OFROOTBALL.SET BALL ON COMPACTED SOILMOUND TO PREVENT SETTLING.NOTES:1. TREES PLANTED TOO DEEP WITHOUT EXPOSING ROOT FLARE WILL BE REJECTED ANDSHALL BE REMOVED AND REPLANTED AT PROPER DEPTH.2. REPLACEMENT OF REJECTED TREES WILL BE DONE AT THE CONTRACTOR'S EXPENSE.ROOTBALLNTS2P-216-0966-42L1.11 1Q:\2016\2160966\40_LAN\CAD\2160966-L.dwg, 22X34, 11/1/2018 9:10:32 AM, JCARLETON, DWG To PDF.pc3, ANSI full bleed D (22.00 x 34.00 Inches), 1:1RECEIVED11/14/2018 jtaylorPLANNING DIVISION
Building ElevationsA2.01Sheet No.Designed by:Drawn by:Checked by:Sheet Title:Revisions:Issue Set & Date:Client:Job No.of Sheets123Project Title:535 DOCK ST, SUITE 211, TACOMA, WA 98402TEL: 253.284.9680 FAX:253.284.9681WWW.TAHOMADESIGNGROUP.COMTAHOMADESIGN GROUPNorthwest Gourmet FoodsFreezer AdditionNorthwest Gourmet Foods600 SW 7th St, Renton, WA 98057Mike Gilroy (425) 793-5001Issue For ClientReview9/24/20182160966.00.10.20JKCJKCPDCREGISTEREDARCHITECTSTATE OF WASHINGTONPHILIPDALE COUTURE11762Q:\2016\2160966\00_PRM\CAD\2160966-A2.01.dwg, A2.01, 9/26/2018 10:08:09 AM, JCARLETON, DWG To PDF.pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:1
RECEIVED
11/14/2018 jtaylor
PLANNING DIVISION
Civil Engineers ● Structural Engineers ● Landscape Architects ● Community Planners ● Land Surveyors
Technical Information Report
PREPARED FOR:
Northwest Gourmet Food Products, Inc.
600 SW 7th Street
Renton, WA 98057-2916
Contact: Mike Gilroy
PROJECT:
Northwest Gourmet Freezer Addition
600 SW 7th Street
Renton, WA 98057-2916
AHBL No. 2160966.10
PREPARED BY:
Tyler D. Watkins, EIT
Project Engineer
REVIEWED BY:
Scott T. Kaul, PE, LEED AP
Project Manager
J. Matthew Weber, PE
Principal
DATE:
June 2018
Revised September 2018
RECEIVED
11/14/2018 jtaylor
PLANNING DIVISION
535 DOCK STREET P: 253-284-9680 tahomadesigngroup.com
SUITE 211 F: 253-284-9681
TACOMA, WA 98402
JUSTIFICATION FOR SEPA ADDENDUM
TO: Mr. Jeffrey Taylor
FROM: James K. Carleton, AIA
DATE: November 2, 2018
PROJECT: Northwest Gourmet Freezer Addition
OUR FILE NO.: 2160966.00, .30
SUBJECT: Justification for SEAP Addendum
Northwest Gourmet operates a food processing company at 600 W 7th Street in Renton. This letter
provides justification for the City of Renton to issue a SEPA Addendum for the proposed building addition
at the Northwest Gourmet site. The proposal is located in the Industrial Medium (IM) zone and is within
the Employment Area Valley (EAV) district.
On June 12, 2013 the City of Renton issued a SEPA Determination of Nonsignificance for the installation
of five tanks (and one future tank for a total of six tanks) with a maximum capacity of 30,881 gallons
each for the storage of products similar to vegetable oil. The tanks would be installed on the west side of
the existing 66,786 SF industrial building. A four-foot wall would be installed around the tanks as a
safety precaution. Other exterior improvements included accessible ramps, a new forklift access at the
loading dock and larger loading dock and forklift doors. No mitigation measures were imposed.
Northwest Gourmet is currently seeking to add a 6,386 square foot freezer addition to the existing
building in place of the existing paved loading dock area on the eastside of the building. Environmental
details include:
· The impervious coverage on the site will remain unchanged.
· The proposal will convert a pollution generating surface to one that discharges clean roof
stormwater. Storm drainage will continue to discharge to the storm drain system on site, which
collects all water and conveys to the City’s regional stormwater system located in SW 7th
Street. Stormwater runoff from the building addition roof will discharge onto splash blocks and
will be collected by the existing private storm drainage system. The proposed 300 square-foot
compressor pad to the south of the building addition will utilize basic dispersion, using sheet flor
or a splash block to discharge to the existing lawn area to the south.
· Three autumn blaze maple trees will be added to the existing planter strip along the frontage.
· There will be no storage, use, or production of any toxic or hazardous chemicals.
· Following construction, there will not be an increase in noise generated at the site.
· No structures will be demolished.
· There are no critical areas on-site.
· There is not an anticipated increase to the existing employee count of 41.
· The building height will be the same as the existing structure, approximately 33 feet.
· No additional parking is required or proposed.
· No new vehicular trips are anticipated and no changes to the existing access are proposed.
WAC 197-11-706 defines a SEPA Addendum as “an environmental document used to provide additional
information or analysis that does not substantially change the analysis of significant impacts and
alternatives in the existing environmental document. The term does not include supplemental EISs. An
RECEIVED
11/14/2018 jtaylor
PLANNING DIVISION
Justification for SEPA Addendum Page 2 of 2
Northwest Gourmet Freezer Addition
2160966.00, .30
addendum may be used at any time during the SEPA process.” The Northwest Gourmet building addition
proposal does not substantially change the analysis of significant impacts and alternatives in the SEPA
DNS issued June 12, 2013. Therefore, we believe a SEPA Addendum is appropriate.
Please feel free to contact me with any questions or concerns.
Thank You,
James K. Carleton, AIA
Vice President
Tahoma Design Group
JKC
c: Lisa Klein, Associate Principal Planning, AHBL
Philip Dale Couture, AIA, Tahoma Design Group
Document1
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 5 LUA18-000667
ADVISORY NOTES TO APPLICANT
The following notes are supplemental information provided in conjunction with the administrative land use
action. Because these notes are provided as information only, they are not subject to the appeal process for
the land use action.
Planning:
(Contact: Jeffrey Taylor, 425-430-7246, JTaylor@rentonwa.gov)
1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless
otherwise approved by the Development Services Division.
2. Commercial, multi-family, new single family and other nonresidential construction activities shall be
restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through
Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight
o’clock (8:00) p.m. No work shall be permitted on Sundays.
3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an
appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where
no further construction work will occur within ninety (90) days. Alternative measures such as mulch,
sodding, or plastic covering as specified in the current King County Surface Water Management Design
Manual as adopted by the City of Renton may be proposed between the dates of November 1st and
March 31st of each year. The Development Services Division’s approval of this work is required prior to
final inspection and approval of the permit.
4. The applicant may not fill, excavate, stack or store any equipment, dispose of any materials, supplies or
fluids, operate any equipment, install impervious surfaces, or compact the earth in any way within the
area defined by the drip line of any tree to be retained.
5. The applicant shall erect and maintain six foot (6') high chain link temporary construction fencing around
the drip lines of all retained trees, or along the perimeter of a stand of retained trees. Placards shall be
placed on fencing every fifty feet (50') indicating the words, “NO TRESPASSING – Protected Trees” or on
each side of the fencing if less than fifty feet (50'). Site access to individually protected trees or groups
of trees shall be fenced and signed. Individual trees shall be fenced on four (4) sides. In addition, the
applicant shall provide supervision whenever equipment or trucks are moving near trees.
6. This permit is shall comply with the Bald and Golden Eagle Protection Act. The permitted is responsible
for adhering to the U.S. Fish and Wildlife Service National Bald Eagle Management Guidelines (2007) and
/or your U.S. Fish and Wildlife Service permit.
Development Engineering:
(Contact: Justin Johnson, 425-430-7291, JTJohnson@rentonwa.gov)
1. See Attached Development Engineering Memo dated December 7, 2018
Fire Authority:
(Contact: Corey Thomas, 425-430-7024, CThomas@rentonwa.gov)
1. Fire impact fees are applicable at the rates of $0.15 per square foot of additional area.
2. Approved fire sprinkler and fire alarm systems are required throughout the building. Separate
plans and permits are required by the fire department.
3. Locate existing underground fire sprinkler supply line and ensure that the proposed new addition
is not being built over the top of the existing line as this is prohibited by code.
ADVISORY NOTES TO APPLICANT
Page 2 of 5 LUA18-000667
Technical Services:
(Contact: Amanda Askren, 425-430-7369, AAskren@rentonwa.gov)
1. No Comments Provided
Community Services:
(Contact: Leslie Betlach, 425-430-6619, LBetlach@rentonwa.gov)
1. Parks Impact fee per Ordinance 5670 applies.
Police:
(Contact: Cyndie Parks, 425-430-7521, CParks@rentonwa.gov)
1. No Comments Provided
Building:
(Contact: Craig Burnell, 425-430-7290, CBurnell@rentonwa.gov)
1. Recommendations of the geotechnical report must be followed as a condition of building permits.
ADVISORY NOTES TO APPLICANT
Page 3 of 5 LUA18-000667
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: December 7, 2018
TO: Jeffery Taylor, Planner
FROM: Justin Johnson, Civil Plan Reviewer
SUBJECT: Freezer Expansion
LUA 18-000667
I have reviewed the application for the Gourmet Food Processing plant at 600 SW 7th St APN(‘s) 1823059254) and have
the following comments:
EXISTING CONDITIONS
The site is approximately 5.01 acres in size and is rectangular in shape. The existing site consists of an existing gourmet
food processing plant. The site consists of a large warehouse building as well as a large paved parking lot on the east side
of the facility.
Water The proposed development is within the City’s water service area and in the Valley 196 Pressure Zone. There is
an existing 12 inch water main (city plan no. W-02390E) located on SW 7th St. The water main can deliver a
maximum flow rate of 1,800 gpm. The static water pressure is about 74 psi at elevation 24 feet. There is an
existing 4– inch domestic water meter and an 8 – inch fire sprinkler supply line with an approved DDCVA located
in the building. The domestic water meter has a 4 inch RPBA located inside the building. The site is located
outside of an Aquifer Protection Area.
Sewer There is an existing 8-inch wastewater main located on SW 7th St (Record Drawing: S-009103).
Storm There is an existing storm drainage system in SW 7th St (see City plan no. R-D-295913). There is also an existing
on-site conveyance system. The site falls within the City’s Flow Control Standard (Exist Peak). The site falls
within the Black River drainage basin.
Streets SW 7th St is a minor arterial street with an available right of way (ROW) width of 80 feet. As per RMC 4-6-060
the minimum ROW width required on a minor arterial is 91 feet with four lanes totaling 54 feet, and street
improvements. Street improvements include an 8 foot sidewalk, 0.5 foot curb, and an 8 foot planter strip.
WATER COMMENTS
1. Based on the current proposal the applicant does not propose any changes to the water service.
SEWER COMMENTS
ADVISORY NOTES TO APPLICANT
Page 4 of 5 LUA18-000667
1. Grease Interceptor is required for the project and is shown on the Utility Plan submitted with the project
application. The grease interceptor shall be sized based on drainage fixture units in accordance with standards
found in the latest edition of the Uniform Plumbing Code (UPC). The grease interceptor shall drain by gravity to
the sewer main. The grease interceptor shall be located on site so that is accessible for routine maintenance.
Grease interceptor shall be a minimum of 1500 gallons.
2. The applicant will need to have King County Industrial Waste review and approve the addition to ensure they
are in compliance with their existing industrial waste permit with King County.
3. If there are modifications or additions to the grease interceptor, then the applicant will need to obtain a permit
through the City of Renton.
STORM DRAINAGE COMMENTS
1. The development is subject to a system development charge (SDC) for stormwater. The 2019 SDC for
stormwater is $0.687 per square foot of new impervious surface area, but not less than $1,718.00. The fee that
is current will be charged at the time of construction permit issuance.
2. A preliminary Drainage Plan and Technical Information Report (TIR), dated September 4, 2018, was submitted by
AHBL with the Land Use Application. Based on the City of Renton’s flow control map, the site falls under Flow
Control Duration Standards (Existing Peak Conditions) and is located within the Black River drainage basin. The
development is subject to a Full Drainage Review in accordance with the 2017 Renton Surface Water Design
Manual (RSWDM). All nine core requirements and the six special requirements have been discussed in the
Technical Information Report. The detention, water quality and conveyance shall be designed in accordance
with the RSWDM that is current at the time of the civil construction permit application. The applicant has
proposed to use basic dispersion for the new roof runoff area.
a. The development currently is showing that there is less than 0.15 CFS increase due to the proposed
development and is exempt from flow control. During the review of the final TIR the applicant will need
to ensure that flow control standards are being met as outlined in the 2017 RSWDM.
b. On-site BMPs satisfying Core Requirement #9 will be required for the site. On-site BMPs shall be
evaluated in order of preference by feasibility as described in Section C.1.3 of the 2017 RSWDM. All
targeted impervious area, to the maximum extent feasible, shall be conveyed to an on-site BMP.
Applicant proposes to use basic dispersion to mitigate the gravel pad area for the concrete compressor
pad.
c. The following stormwater improvements are required and shall be discussed or revised within the TIR:
i. Feasibility of On-site BMPs must be based on the feasibility criteria established for the specific
On-site BMPs noted in Appendix C of the 2017 RSWDM. A feasibility analysis of the On-site
BMPs was provided with the TIR.
1. Perforated pipe connection is feasible and should be connected into existing
conveyance system.
3. A Geotechnical Report, dated May 22, 2013, completed by E3RA, Inc for the site has been provided. The
submitted report describes multiple layers of soil characteristics. Approximately the first 1 to 2 feet contain
imported fill. Below the surface there is approximately 10 feet of soft silt. The report did not provide any
recommendation for stormwater management.
TRANSPORTATION/STREET COMMENTS
1. The 2018 transportation impact fee is $1.29 per square foot for mini-warehouse. Fees are payable at the time of
building permit issuance. Transportation Impact Fees for additional uses can be found on the City’s website.
Transportation impact fees are due at the time of building permit issuance.
ADVISORY NOTES TO APPLICANT
Page 5 of 5 LUA18-000667
2. SW 7th St is a minor arterial street with an available right of way (ROW) width of 80 feet. As per RMC 4-6-060
the minimum ROW width required on a minor arterial is 91 feet with four lanes totaling 54 feet, and street
improvements. Street improvements include a 12 foot sidewalk, 0.5 foot curb, and an 8 foot planter strip. The
developer is required to provide the ROW dedication and construct the frontage improvements.
a. The City has reviewed the submitted street modification and has attached the determination.
3. Paving and trench restoration within the City of Renton right of way shall comply with the City’s Street
Restoration and Overlay requirements.
GENERAL COMMENTS
1. Retaining walls that are 4’ or taller from bottom of footing and stormwater detention vaults will require a
separate building permit. Structural calculations and plans prepared by a licensed engineer will be required as
part of the building permit review.
2. All civil plans shall conform to the current City of Renton survey and drafting standards. Current drafting
standards can be found on the City of Renton website.
3. A separate plan submittal will be required for a construction permit for utility work and street improvements. All
plans shall be prepared by a licensed Civil Engineer in the State of Washington.
4. Please see the City of Renton website for the Construction Permit Application and Construction Permit Process
and Submittal Requirements. Please contact the City to schedule a construction permit intake meeting.
5. Beginning April 3, 2017, the City will transition to electronic plan review. See http://rentonwa.gov/paperless for