HomeMy WebLinkAboutS-401406I �
I �O
I 4
I
S _3 S .� t
v
i
,
do oil
� .� A. � ice" vvvA•_jY�AAAAA �����A--'
�p ���\;� \� �-. _ _ : ',mac_' \\\\\\\\\`��\\\\\\\\`` �������\�" T � : 1 • � � � � � �
RPM
•� 1 1 T "10
I L _ '� 11 • LV.JV
P _ p p p 4. SEE PAVING AND GRADING DETAIL PLAN SHEETS C501-5A
INV N�W 19.38 T� Box C UI ° o ° " INV 20. 78 -12" S N THROUGH C501-5D FOR PAVING DETAILS, HORIZONTAL CONTROL
N 19.41 1812A-A VAULT D2 ` °
C���•� ®Q. % AND GRADING INFORMATION.
8.56
CO TOP 22.26 � �P 22.60 �� cw 5. SEE STORM DRAINAGE DETAIL PLAN SHEETS C501-6A THROUGH
W o < C501-6P FOR STORM SYSTEM IMPROVEMENT DETAIL.
z ° ° - 0 1 6. SEE UTILITY DETAIL PLAN SHEETS M501-1A THROUGH M501-1 D
I MH II 0o , CBI .. , I
1
6 TOP 20.8 1 FOR FIRE WATER SYSTEM IMPROVEMENT DETAILS.
I RIM 21.88 � d . .. 1 I
1
FL 15.30 + ;:::.. n a
CW W O IN 18.7 N 7. SEE CHANNELIZATION PLANS FOR PAVEMENT MARKINGS, TRANSIT - �I FEATURES AND SIGN IMPROVEMENT DETAIL.
�p C •
6 CW� v INV-19.71
8. ALUMINUM DRAINAGE FLAP GATE SHALL BE WATERMAN
Q
3gVN 0 TPA o 2*
UP INDUSTRIES AF-41 TYPE 6 SPIGOT FOR HDPE AND SHALL BE
o f 4"CW 13.8KyUGT o CB 694 C I INSTALLED PER MANUFACTURER'S RECOMMENDATION.
EMGS 0Gj oo 6 1 LF 6" PVC SDR 35 ® 1.0% I
^� INV= 0? x 9. NEW TYPE 1 CB'S IN BIORETENTION CELLS SHALL BE PER CITY
ASP " 2 675A-18 INV N 20.4 62PVC OF RENTON STANDARD PLAN 200. AIRCRAFT RATED STRUCTURES
GA 2' W CB TYPE 1 1 S 20.4 SD ARE NOT REQUIRED.
CO „w F� E No. 687 MH 6" GATE VALVE W/BEEHIVE GRATE BOT 1
P 2 CBI 216 Q AV- -04) : �? 22.4 RIM: 22.80 10. FRAME AND BEEHIVE GRATE SHALL BE OLYMPIC FOUNDRY TYPE
.
CS TOP 21.21 N: 183559.37 SD CLEANour I SM60 AND SM60BH OR APPROVED EQUAL.
U F, E STING ELEPH C N 18.8 ■ RIM=23.34
CO DUIT CS -� 6 A 675. E: 1300505.26 I 11. SEE SHEET C501-6Q FOR EXISTING PAVEMENT GRADE DETAILS
BL W-OF INV S 18.7 1,. _ IE (E) = 20.15 (8" HDPE)
3• BOT 18.3 1 /4 UP LTG ' EX CB TYPE 1 L 4 PVC %� IE (W) - 20.15 (8" HDPE)
AT BIORETENTION CELLS.
C : �... RIM: 22.48375
w :B N: 183557.77 INV=19 21 IE (N) = 20.15 (6" UNDERDRAIN) IM 22.4 1
CB c° .E: 1300442.63 691 N .1' X 1. NER DIME SION -
TOP 1.67 TL;, _� BIORETENTION CELL PER DETAIL 1 ON SHEET C501 6E
B-I N 18.6 CIE (N) = 19.84 (12' EX CMP) YPE - 768 - 1
°' I 18 5 N , ARE UP IE (S) = 19.82 (18" EX CMP) x CO r - I U 2� BIORETENTION CELL PER DETAIL 2 ON SHEET C501-6E
OP 21.85 CO .IE (E) = 19.84 (8 HDPE) PV (E) I.E. = 0 I, it
NC ASPHALT INV W . CB-61 N, `�/'' 2Q LF 3 12" C P (N I.E. 4 I' I U 3� BIORETENTION CELL PER DETAIL 3 ON SHEET C501-6E
.91 LLJ
No. 696 INV W CAP 20.0 BOT 7. OP 21.3 � 11. 22.35 674E-18 C SDR 3 0.4� " P V (W) I . E. 1 .5 I =
2 I, I 4 BIORETENTION CELL PER DETAIL 2 ON SHEET C501-6F
CB -I BOT 19. 8 M 0 CB TYPE 1 6*FC I cn
TOP 21.8 6'• S'1� /
I� URIMBE22174 GRATE I 63 LF 8" HDPE LwL_I
INVN S 18.
1 21.79 =N:183495.42 I� CONSTRUCTION NOTES
E: 1300512.48 z
674 IE (E) = 19.93 (8" HDPE) CDG LTG 1 _ CD 1 CORE DRILL AND CONNECT NEW STORM PIPE TO EXISTING
S INV S 18. EX CB TYPE 1 L IE (W) = 19.93 (12 HDPE) STRUCTURE AND PROVIDE ALUMINUM FLAP GATE AT NEW
BOT RIM: 22.62 73 PV(IE (N) 19.99 (6 UNDERDRAIN) 10 LF 12 HDPE INV=19.78 PIPE CONNECTION
z
1 .0 0 6" CO 2 CO 6" N: 183501.04 CJ COXCo
Co0 o E: 1300442.51 3 CO 6° VC I z 2� PROVIDE STORM DRAINAGE CATCH BASIN TYPE 1 WITH
1 2 IE (N) = 19.79 (18 EX CMP) 1 I U BEEHIVE GRATE
HH IE (S) = 19.79 (18" EX CMP) 4 U
ASPHALT IE (SE) = 19.79 (12" HDPE) Q::� 3� PROVIDE 4" WIDE WHITE LINE FOR PARKING STALL FOR NEW
N 18.5 CW U - - U
INV 18 9'x2O' PARKING STALL
rn �0 685 rl - r - 1
Z INV SW 1 %CB -I 674A-18 22.7 li it I I B� PROVIDE WHEEL STOP
a 60T OP 21.31 2 1 I I
6" A CB TYPE 1 3 li i I I I I I W
No. 693 „M G -W/BEEHIVE GRATE ,� ;I I I z
CB -I 6 S �' 2" UG 4-66 RIM: 22.08 / CB-695 Isis, ^� -
TOP 21.20 ®� -�---- „ W-401406
2 UG SPARE N: 183495.08 TYPE 650 ` 62 LF 12 HDPE _
6 E: 1300450.03 673 TOP=22.72
IE (N) = 19.83 (6" ELEVATED 1 INV=20.72 2 ~
UNDERDRAIN) RI CB TYPE 1 L 73 S-401406
� RIM: 22.67
NV W /� 19•5 \ N: 183443.19 RIM B 67 64
IE (NW) = 19.81 (12 HDPE) RIM = 22.66
OT 19. IE (E) = 19.81 (12 HDPE) E: 1300442.50 : ;:1�,';': 2.1 X1 7 INNER DIMENSION 2 - KEY PLAN
#77533
IE (N) = 19.77 (18" EX CMPK-*-. # UN BLE TO OPEN SCALE : NONE
55 LF 4" PV ®0.0 18„ CMP (N) I.E. 3 7
IE (S) = 19.77 (18 EX CMP)
IE (SE) = 19.77 (12 HDPE) (S) I.E. = 19.77 A B C D E F G H J K L
S 4 28 LF 12 HDPE
VAU ` N, 22.75 - I C 11
673A-18 P STL UP U r U C12 o
ASPHALT n � 2 I it i
No. 692 CB TYPE 1 CB-6 6 3 I l C 13 °
p 121.73 INV W/CAP 20.4 0 W/BEEHIVE GRATE
RIM: 22.31 TOP=2 .75 I C 14
BOT 19.6
N: 183431.05 IM672B-18 ' S1S C15 1PH OYE
6 p E: 1300467.93 2 ` 80 LF 12 HDPE -
6 GN 1 IE (NW) = 19.83 (12" HDPE) / CB TYPE 1 C16 W �®
IE (E) = 19.83 (12" HDPE) W/BEEHIVE GRATE
C17
3
IE (N) = 19.91 (6" ELEVATED RIM: 22.80 SDCB 672
.C18
N: 18338389 °
UNDERDRAIN) RIM 22.63 '
MF D3 E: 1300495.93 2.1' X 1.7' INNER DIMENSION C19 0
IE (E) = 19.81 (8" HDPE) 1 - - TYPE 1
IE (W) _ 19.81 (8;' HDPE) 8" C P 1 19. 3 I C20 0
PH IE (S) = 19.81 (6 UNDERDRAIN) 8" C P (S) I.E. 19. 9
CON C I C21
15 LF 12" HDPE
4-75
C23 0
No. 683 C22
_ 672 -
No. x 1 EX CB TYPE 1 L : �: -
-11-48TOP
RIM 21.21 BOT 16 76 RIM: 22.65 : •� ::_ C24
INV W 18.20 N: 183385.19 :. _ 1 1 I C25
CO 1931 E: 1300442.32 CB-6 9 672A-18 (/ I I 1
No. 691 INV S 18.20
CB -I IE (N) = 19.63 (18" EX CMP) TYPE 2 I \'� I I� I I I C26
TOP 21.8 32 IE (S) = 19.59 (18" EX CMP) TOP= 16 CB TYPE 1 I I 11 I
INV N 18.3 ? _ °° I 2 6 W/BEEHIVE GRATE / I C27
SEC84 N 684 (,tl IE (E) 19.59 (12 HDPE) RIM: 22.30 ( � J
41
INV E 18.3 CB -I A ` C28
BOT 17.3 �S TOP 1.46 N: 183384.31 3 �n - - - SDC r-6rr -
�* GQ� 1905 " E: 1300457.78 / - C29
82 r, 22.02 INV 18.1 59 LF 4 �ii RIM - 2 2.71
FH45 2 INV N 18.2 IE (W) = 19.62 (12" HDPE) 38 LF 8 HDPE 2.1' X 1.7' INNER DIMENSION I C30
No_689A96 !s S� BOT 1 .0 Q 6 A IE (E) = 19.62 (8" HDPE) 4 TYPE 1 - # 1 -
CO 293 CB II-48 �,A NZ �Gl� x IE (S) 19.85 (6" ELEVATED 18" CMP (N) - 1 .56 R-401441.38 TOP 20.30
E`,o "° 1 ,c'�S UNDERDRAIN) --18�CMP (S�E. = 1 53
INV S INV S 14ASPHALT
BOT 15.30 30 51 _.80 _ _ _ _ _ _ _ 4 IN COMPLIANCE WITH CITY OF RENTON STANDARDS
i BergerABAM MATCH LINE - FOR C 0 N T I N U AT I 0 N SEE SHEET C 18 E CIVIL PERMIT SET DEVELOPMENT ENGINEERING +
20 0 20 40
CALL 48 HOURS "�
V3 n Ann Fowler 12/14/2018
BEFORE YOU DIG 33301 9th Avenue South, Suite 300 I v
1-800-424-5555 Federal Way, Washington 98003-2600 DESIGN BY: BERGERABAM DATE 10/22/2018 scale feet Frstraka
URFACE 12/14WATER 2018UTILITY0
(206) 431-2300 Fax: (206) 431-2250 12/14/2018
SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
�N P. THIS ACCEPTABILITY
CHECKED HL 10 09 18 PARTIAL SITE UTILITIES PLAN C180242 N 10/19/18
M MITIGATION HANGAR C180242 ABAM SPT 10/09/18 F D-35 ENTRANCE J#140882 REI DED 12/12/07 T� CPT 10 09 18 SHEET
w of WAsx�� G SPECIFICATION IS APPROVED
N MITIGATION HANGAR -CITY OF RENTON COMMENTS C180242 ABAM SPT 10/19/18 G DRAWING OF RECORD J#140882 REI DED 12/12/07 ® ���`� c°>� APPROVED BY DEPT. DATE BEENEER 10 09 18
ff"A,��CHECKED C 17 E C32
TITLE MITIGATION HANGAR
B PARKING LOT 15 REI DED 03/12/04 H UPGRADE 20 SCALE SITE PLANS (DHA 09-1637) 9488981 AAC DAH 04/30/10 "1() w� RENTON
' TO A ' SITE
T�
,�� 31z71 �° �q, APPROVED K Iv I Iv J I JOB NO. COMP NO.
E LOT RECONFIGURATION J#031098 REI DED 10/11/06 J GATE D-35 AND BADGE OFFICE -RECORD W1855850 ABAM 11/30/14 SSI�sTCR�G C180242
ONAL 6
D DRAWING OF RECORD J#031098 REI DED 11/04/04 K PED PATHS & PARKING - RECORD W2651523 ABAM 05/01/15 APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. RTN-YD-17E