PIPE CROSSING TABLE
CROSSING #
PIPE ABOVE
BOTTOM ELEVATION
PIPE SIZE
PIPE BELOW
TOP ELEVATION
PIPE SIZE
VERTICAL CLEARANCE
10
EX STORM
14.79
12.00"
STORM
14.24
18.00"
0.55'
20
STORM
14.64
18.00"
STORM
14.13
18.00"
0.51'
30
FIRE
17.34
6.00"
STORM
14.90
30.00"
2.44'
40
STORM
15.16
8.00"
STORM
14.57
30.00"
0.59'
50
EX SEWER
14.73
6.00"
STORM
14.07
12.00"
0.66'
60
FIRE
14.29
10.00"
STORM
13.93
12.00"
0.73'
70
STORM
15.25
12.00"
STORM
13.91
12.00"
1.34'
80
STORM
14.96
12.00"
STORM
13.77
12.00"
1.19'
90
HDPE
15.59
8.00"
FIRE
14.26
10.00"
1.33'
10
EX SS
16.55
8.00"
STORM
15.50
12.00"
1.05'
11
EX AIR
15.30
8.00"
EX STORM
14.71
12.00"
0.59'
12
EX AIR
16.38
8.00"
EX STORM
14.29
13.00"
0.59'
13
EX FW
14.88
12.00"
STORM
14.27
12.00"
2.09'
14
EX WATER
15.88
8.00"
STORM
14.26
8.00"
1.62'
15
WATER
17.09
8.00"
STORM
16.11
14.00"
0.98'
16
WATER
16.70
8.00"
EX FW
16.02
8.00"
0.68'
* CROSSING PIPES HAVE LESS THAN 6" CLEARANCE BETWEEN
THEM SEE NOTE 5 ON C501-6D.
#4 EPDXY COATED REBAR
@ 12" O.C. EA. WAY, TOP &
BOTTOM, UNLESS OTHERWISE NOTED
(3) #4 EPDXY COATED REBAR @ 3.5" EA. WAY
SLAB INTERFACE SEE NOTE 5
4-83 BUILDING SLAB FF EL 19.35
24" NYLOPLAST BASE PLATE AND
24" x 20" FRAME CAST INTO
CONCRETE COLLAR
(3) #4 EPDXY COATED REBAR @ 3.5" EA. WAY
SLOT DRAIN IF
PRESENT
3" CLEAR MIN (TYP)
(3) #4 EPDXY COATED REBAR @ 3.5" EA. WAY
24" x 20" FRAME W/BASE PLATE PLAN VIEW
PROVIDE DOWELED
CONSTRUCTION JOINT (TYP)
#4 @ 12" O.C., EA.
CEMENT
WAY, EPDXY COATED
CONCRETE
PAVEMENT
2_1/2»
MIN CLR (TYP)
°
/11
2-1/2"
MIN CLR (TYP)
12" CSBC
DIAGONAL #4 @3.5" O.C. -
24" NYLOPLAST BASE PLATE AND
24" x 20" FRAME CAST INTO
CONCRETE COLLAR
-SLAB INTERFACE SEE NOTE 5
r-- BUILDING SLAB
°
o J
24" PVC DRAIN
CONCRETE COLLAR NOTES:
1. CRUSHED SURFACING BASE COURSE (CSBC)
SHALL BE COMPACTED TO AT LEAST 95% OF
MAX. DRY DENSITY PER ASTM D-1557.
2. CONCRETE PAVEMENT SHALL MATCH PAVEMENT
REQUIREMENTS SHOWN ON THE PAVING PLANS.
3. SEE STRUCTURE AND PIPE BEDDING DETAILS FOR
ADDITIONAL INFORMATION.
4. FOR ADDITIONAL REQUIREMENTS SEE THE
GENERAL NOTES ON SHEET C501-113.
5. SEE STRUCTURAL PLANS FOR SLAB
INTERFACE, CONCRETE CORBEL, CONCRETE GRADE
BEAM, AND BUILDING SLAB DETAILS.
ADS DURASLOT DRAIN
8" HDPE DUAL WALL PIPE
WITH 15" SLOT. INSTALL PER
MANUFACTURERS RECOMMENDATIONS.
1
TOP OF SLOT SHALL BE DEPRESSED 1 /2"
BELOW SURROUNDING PAVEMENT
1. SLOTTED DRAIN ASSEMBLY SHALL BE HANCOR DURASLOT, OR
APPROVED EQUAL. SLOTTED DRAIN AND TRENCH SHALL MEET AIRPORT
LOAD RATING REQUIREMENTS. MANUFACTURER SHALL PROVIDE
STAMPED SUBMITTAL DRAWINGS PRIOR TO MATERIAL ACCEPTANCE.
INSTALLATION SHALL BE PER MANUFACTURER'S RECOMMENDATIONS.
2. HIGH SLUMP CONCRETE SHALL HAVE MINIMUM 1000 PSI 28-DAY
COMPRESSIVE STRENGTH.
3. CONCRETE PAVEMENT ABOVE SLOTTED DRAIN TRENCH SHALL MATCH
PAVEMENT REQUIREMENTS SHOWN ON THE PAVING PLANS. IF
REINFORCEMENT IS SHOWN ON THE PAVEMENT PLANS, IT SHALL BE
CONTINUED ACROSS SLOTTED DRAIN TRENCH.
4. SLOTTED DRAIN PIPE SHALL BE HIGH DENSITY POLYETHYLENE OR
ALUMINIZED STEEL TYPE 2. PIPE WALL THICKNESS AND GAUGE SHALL
BE AS REQUIRED TO MEET AIRPORT LOADING REQUIREMENTS. PIPE
MATERIAL SHALL HAVE A MAXIMUM MANNING COEFFICIENT OF 0.024.
FINAL CONFIGURATION OF SLOTTED DRAIN ASSEMBLY AND TRENCH
SHALL MEET THE DIMENSIONS SHOWN BASED ON SELECTED PIPE
MATERIAL AND SLOT DIMENSIONS.
5. ALL METAL PARTS USED IN SLOT DRAIN ASSEMBLY INCLUDING PIPE,
SLOT, COUPLING BANDS, AND FITTINGS SHALL BE NON GALVANIZED
ALUMINIUM, STAINLESS STEEL, ALUMINIZED STEEL, OR PLASTIC.
6. SEE STRUCTURAL PLANS FOR SLAB INTERFACE, CONCRETE CORBEL,
CONCRETE GRADE BEAM, AND BUILDING SLAB DETAILS.
CONCRETE PAVING
AS SHOWN ON PAVING
PLANS (TYP) SEE NOTES
14.5" PCCP PAVEMENT ----x
30" #5 EPDXY COATED
REBAR, 18" O.C. TYP -
oQ
±2%
J
J-
3" MIN CI�RT-
�Tv�
±12"
CSBC
PIPE INVERT ELEVATION
AS SHOWN ON PLANS -
CONCRETE TRANSITION
SLAB. SEE NOTE 6 -
±2% ` 7
o°
18� I�
SLAB INTERFACE SEE NOTE 6
EXISTING BUILDING SLAB. SEE NOTE 6
15" ACTUAL
SLOT HEIGHT
±2%
0
J
°
J
°
-2'-0 °
�J
0
o T
0
°
N
CD
w�
m
z
o
�o
SLOT DRAIN AT HANGAR DOOR
C501-5A SCALE: NTS
C501-5B
C11E
C12E
FF EL 19.35
#4 EPDXY COATED
REBAR, 12" O.C. (TYP)
TOP OF SLAB EL 17.06
T_
o
CD
I
°
J
J
2
HIGH SLUMP CONCRETE
SEE NOTE 2
(M CONCRETE COLLAR AT HANGAR DOOR
C50�1 -5A SCALE: NTS R-401452
C501-5B
C11 E IN COMPLIANCE WITH CITY OF RENTON STANDARDS
iBergerABAMV3 C12E CIVIL PERMIT SET
DEVELOPMENT ENGINEERING
��
Ann Fowler 12/14/2018
CALL 48 HOURS
BEFORE YOU DIG 33301 9th Avenue South, Suite 300
1- 800- 424- 5555 Federal Way, Washington 98003-2600 DESIGN BY: BERGERABAM DATE 10/22/2018 SURFACE WATER UTILITY
(206) 431-2300 Fax: (206) 431-2250 rstraka 12/14/2018
SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
ACCEPTABILITY HL 10/09/18 STORM DETAILS C180242 0 R G 10/09/18
ORIG MITIGATION HANGAR C180242 ABAM SPT 10/09/18 ��N P. T THIS DESIGN AND/OR CHECKED
of WA3A, �i' SPT 10/09/18 SHEET
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE BEE
10/09/18 TITLE MITIGATION HANGAR
CHECKED C501-6D C44
RENTON SITE
�o R 31271 o ww JOB N0. COMP NO.
���SIDNAPPROVED C 180242
AL
APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. RTN-YD-0501-6D