HomeMy WebLinkAboutR-401452co N 00 0 N C U O E 0 c 0 a� c� in m J PIPE CROSSING TABLE CROSSING # PIPE ABOVE BOTTOM ELEVATION PIPE SIZE PIPE BELOW TOP ELEVATION PIPE SIZE VERTICAL CLEARANCE 10 EX STORM 14.79 12.00" STORM 14.24 18.00" 0.55' 20 STORM 14.64 18.00" STORM 14.13 18.00" 0.51' 30 FIRE 17.34 6.00" STORM 14.90 30.00" 2.44' 40 STORM 15.16 8.00" STORM 14.57 30.00" 0.59' 50 EX SEWER 14.73 6.00" STORM 14.07 12.00" 0.66' 60 FIRE 14.29 10.00" STORM 13.93 12.00" 0.73' 70 STORM 15.25 12.00" STORM 13.91 12.00" 1.34' 80 STORM 14.96 12.00" STORM 13.77 12.00" 1.19' 90 HDPE 15.59 8.00" FIRE 14.26 10.00" 1.33' 10 EX SS 16.55 8.00" STORM 15.50 12.00" 1.05' 11 EX AIR 15.30 8.00" EX STORM 14.71 12.00" 0.59' 12 EX AIR 16.38 8.00" EX STORM 14.29 13.00" 0.59' 13 EX FW 14.88 12.00" STORM 14.27 12.00" 2.09' 14 EX WATER 15.88 8.00" STORM 14.26 8.00" 1.62' 15 WATER 17.09 8.00" STORM 16.11 14.00" 0.98' 16 WATER 16.70 8.00" EX FW 16.02 8.00" 0.68' * CROSSING PIPES HAVE LESS THAN 6" CLEARANCE BETWEEN THEM SEE NOTE 5 ON C501-6D. #4 EPDXY COATED REBAR @ 12" O.C. EA. WAY, TOP & BOTTOM, UNLESS OTHERWISE NOTED (3) #4 EPDXY COATED REBAR @ 3.5" EA. WAY SLAB INTERFACE SEE NOTE 5 4-83 BUILDING SLAB FF EL 19.35 24" NYLOPLAST BASE PLATE AND 24" x 20" FRAME CAST INTO CONCRETE COLLAR (3) #4 EPDXY COATED REBAR @ 3.5" EA. WAY SLOT DRAIN IF PRESENT 3" CLEAR MIN (TYP) (3) #4 EPDXY COATED REBAR @ 3.5" EA. WAY 24" x 20" FRAME W/BASE PLATE PLAN VIEW PROVIDE DOWELED CONSTRUCTION JOINT (TYP) #4 @ 12" O.C., EA. CEMENT WAY, EPDXY COATED CONCRETE PAVEMENT 2_1/2» MIN CLR (TYP) ° /11 2-1/2" MIN CLR (TYP) 12" CSBC DIAGONAL #4 @3.5" O.C. - 24" NYLOPLAST BASE PLATE AND 24" x 20" FRAME CAST INTO CONCRETE COLLAR -SLAB INTERFACE SEE NOTE 5 r-- BUILDING SLAB ° o J 24" PVC DRAIN CONCRETE COLLAR NOTES: 1. CRUSHED SURFACING BASE COURSE (CSBC) SHALL BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY PER ASTM D-1557. 2. CONCRETE PAVEMENT SHALL MATCH PAVEMENT REQUIREMENTS SHOWN ON THE PAVING PLANS. 3. SEE STRUCTURE AND PIPE BEDDING DETAILS FOR ADDITIONAL INFORMATION. 4. FOR ADDITIONAL REQUIREMENTS SEE THE GENERAL NOTES ON SHEET C501-113. 5. SEE STRUCTURAL PLANS FOR SLAB INTERFACE, CONCRETE CORBEL, CONCRETE GRADE BEAM, AND BUILDING SLAB DETAILS. ADS DURASLOT DRAIN 8" HDPE DUAL WALL PIPE WITH 15" SLOT. INSTALL PER MANUFACTURERS RECOMMENDATIONS. 1 TOP OF SLOT SHALL BE DEPRESSED 1 /2" BELOW SURROUNDING PAVEMENT 1. SLOTTED DRAIN ASSEMBLY SHALL BE HANCOR DURASLOT, OR APPROVED EQUAL. SLOTTED DRAIN AND TRENCH SHALL MEET AIRPORT LOAD RATING REQUIREMENTS. MANUFACTURER SHALL PROVIDE STAMPED SUBMITTAL DRAWINGS PRIOR TO MATERIAL ACCEPTANCE. INSTALLATION SHALL BE PER MANUFACTURER'S RECOMMENDATIONS. 2. HIGH SLUMP CONCRETE SHALL HAVE MINIMUM 1000 PSI 28-DAY COMPRESSIVE STRENGTH. 3. CONCRETE PAVEMENT ABOVE SLOTTED DRAIN TRENCH SHALL MATCH PAVEMENT REQUIREMENTS SHOWN ON THE PAVING PLANS. IF REINFORCEMENT IS SHOWN ON THE PAVEMENT PLANS, IT SHALL BE CONTINUED ACROSS SLOTTED DRAIN TRENCH. 4. SLOTTED DRAIN PIPE SHALL BE HIGH DENSITY POLYETHYLENE OR ALUMINIZED STEEL TYPE 2. PIPE WALL THICKNESS AND GAUGE SHALL BE AS REQUIRED TO MEET AIRPORT LOADING REQUIREMENTS. PIPE MATERIAL SHALL HAVE A MAXIMUM MANNING COEFFICIENT OF 0.024. FINAL CONFIGURATION OF SLOTTED DRAIN ASSEMBLY AND TRENCH SHALL MEET THE DIMENSIONS SHOWN BASED ON SELECTED PIPE MATERIAL AND SLOT DIMENSIONS. 5. ALL METAL PARTS USED IN SLOT DRAIN ASSEMBLY INCLUDING PIPE, SLOT, COUPLING BANDS, AND FITTINGS SHALL BE NON GALVANIZED ALUMINIUM, STAINLESS STEEL, ALUMINIZED STEEL, OR PLASTIC. 6. SEE STRUCTURAL PLANS FOR SLAB INTERFACE, CONCRETE CORBEL, CONCRETE GRADE BEAM, AND BUILDING SLAB DETAILS. CONCRETE PAVING AS SHOWN ON PAVING PLANS (TYP) SEE NOTES 14.5" PCCP PAVEMENT ----x 30" #5 EPDXY COATED REBAR, 18" O.C. TYP - oQ ±2% J J- 3" MIN CI�RT- �Tv� ±12" CSBC PIPE INVERT ELEVATION AS SHOWN ON PLANS - CONCRETE TRANSITION SLAB. SEE NOTE 6 - ±2% ` 7 o° 18� I� SLAB INTERFACE SEE NOTE 6 EXISTING BUILDING SLAB. SEE NOTE 6 15" ACTUAL SLOT HEIGHT ±2% 0 J ° J ° -2'-0 ° �J 0 o T 0 ° N CD w� m z o �o SLOT DRAIN AT HANGAR DOOR C501-5A SCALE: NTS C501-5B C11E C12E FF EL 19.35 #4 EPDXY COATED REBAR, 12" O.C. (TYP) TOP OF SLAB EL 17.06 T_ o CD I ° J J 2 HIGH SLUMP CONCRETE SEE NOTE 2 (M CONCRETE COLLAR AT HANGAR DOOR C50�1 -5A SCALE: NTS R-401452 C501-5B C11 E IN COMPLIANCE WITH CITY OF RENTON STANDARDS iBergerABAMV3 C12E CIVIL PERMIT SET DEVELOPMENT ENGINEERING �� Ann Fowler 12/14/2018 CALL 48 HOURS BEFORE YOU DIG 33301 9th Avenue South, Suite 300 1- 800- 424- 5555 Federal Way, Washington 98003-2600 DESIGN BY: BERGERABAM DATE 10/22/2018 SURFACE WATER UTILITY (206) 431-2300 Fax: (206) 431-2250 rstraka 12/14/2018 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE ACCEPTABILITY HL 10/09/18 STORM DETAILS C180242 0 R G 10/09/18 ORIG MITIGATION HANGAR C180242 ABAM SPT 10/09/18 ��N P. T THIS DESIGN AND/OR CHECKED of WA3A, �i' SPT 10/09/18 SHEET SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE BEE 10/09/18 TITLE MITIGATION HANGAR CHECKED C501-6D C44 RENTON SITE �o R 31271 o ww JOB N0. COMP NO. ���SIDNAPPROVED C 180242 AL APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. RTN-YD-0501-6D