Loading...
HomeMy WebLinkAboutR-401453i7 N 00 0 N C U O E 0 c 0 ca in cv J I \ J 2' 9.0' NOTE: TYPICAL BIORETENTION CELLS RETENTION CELLS IN NORTH ROW OF PARKING CELLS SHALL BE MIRRORED. BIORETENTION CELL LAYOUT 1 TYPICAL AT 675A, 67513, 67413, 674C, 67213, 672C, 671 B, & 671 C C17E SCALE: 1" = 5' C18E C17F C18F C17E \1-1/ m NOTE: TYPICAL BIORETENTION CELLS RETENTION CELLS IN NORTH ROW OF PARKING CELLS SHALL BE MIRRORED. BORETENTON SCALE: 1 " = 5' LAYOUT AT 6 7 2 A 2 1/2" TYP. I 5" DRILL HOLES THRU PAVEMENT TO MATCH WHEELSTOP HOLE PATTERN. DRIVE 24" LONG REBAR THROUGH WHEELSTOP AND PAVEMENT INTO SUBGRADE. 1" RADIUS TYP. PREFABRICATED WHEEL STOP TOP OF PAVEMENT (3) #4 REBAR 2'-0" LONG PER WHEEL STOP C18E \1-1/ BIORETENTION. SCALE: 1 " = 5' LAYOUT AT 6 71 A GENERAL NOTES 1. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICA DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) _ NGVD29 + 3.60 FEET. 2. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. 3. PERMANENT WATER QUALITY TREATMENT FACILITIES SHALL NOT BE USED TO CONVEY OR CONTAIN CONSTRUCTION STORM WATER. NEW FACILITIES SHALL BE KEPT OFFLINE UNTIL PROJECT IS COMPLETE. THE CONTRACTOR SHALL CLEAN AND FLUSH ALL PARTS OF THE SYSTEM PRIOR. SEE GENERAL NOTES ON SHEET C501-1A AND C501-113. 4. SEE SHEETS C17E, C17F, C18E, AND C18F FOR OVERFLOW STRUCTURE INFORMATION AND CONVEYANCE PIPE INFORMATION. 5. SEE BIORETENTION LANDSCAPING PLANS ON SHEETS L501-7A THROUGH 1_501-713 FOR PLANTING DETAILS. 6. BIORETENTION SOIL MEDIA SHALL BE PER THE BIORETENTION SOIL MEDIA STANDARD SPECIFICATIONS PROVIDED IN REFERENCE SECTION 11—C OF THE 2017 CITY OF RENTON SURFACE WATER DESIGN MANUAL. SEE SHEET C501-6G. 7. STREAMBED COBBLES SHALL BE PER WSDOT STANDARD SPEC SECTION 9-30.11(2) 8. SLOTTED UNDERDRAIN SHALL BE SLOTTED SUBSURFACE DRAIN PVC PER ASTM D1785 SCH 40. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS OF THE PIPE AND BE 0.04 TO 0.069 INCHES BY 1 INCH LONG AND BE SPACED 0.25 INCHES APART (SPACED LONGITUDINALLY). SLOTS SHOULD BE ARRANGED IN FOUR ROWS SPACED ON 45—DEGREE CENTERS AND COVER 1/2 OF THE CIRCUMFERENCE OF THE PIPE. OBSERVATION WELL CONSTRUCTED OF NON —PERFORATED MATERIAL SHALL BE LOCATED AT END OF PIPE. OBSERVATION PORT SHALL HAVE LOCKING CAST—IRON LID. 9. EXTRUDED CURB SHALL BE WSDOT STD PLAN F-10.42-00 TYPE 6 10. INSTALL NEW/SALVAGED CONCRETE WHEELSTOP PER DETAIL 5, SHEET C501-6E. 11. CONTRACTOR SHALL VERIFY DEPTH TO SEASONAL HIGH GROUNDWATER PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER IMMEDIATELY IF DEPTH IS LESS THAN 7.5—FEET FROM EXISTING GRADE. 12. CONTRACTOR'S AS —BUILT RECORD DOCUMENTS SHALL INCLUDE IN —PLACE INFILTRATION RATE FOR EACH COMPLETE BIORETENTION CELL. INFILTRATION RATE TEST SHALL BE PERFORMED USING THE PILOT INFILTRATION TEST (PIT) METHOD AT THE FINISHED SURFACE OF THE BIORETENTION SOIL MIX WITH A MAXIMUM 6—INCH PONDING DEPTH. CONSTRUCTION NOTES EXISTING PARKING STALL STRIPING PROVIDE EXTRUDED CURB, MATCH FACE OF CURB TO EXISTING PARKING STALL STRIPING CONCRETE WHEEL STOP, MATCH FACE OF WHEEL STOP TO EXISTING PARKING STALL STRIPING R� 6" SLOTTED UNDERDRAIN :� OBSERVATION WELL EDGE OF ASPHALT/TOP OF FREE BOARD 7� TOP OF PONDING/BOTTOM OF FREE BOARD :� TOP OF SOIL/BOTTOM OF PONDING OVERFLOW CONVEYANCE PIPE CONNECTIONS PER PLAN 10 PROVIDE 18—INCH MINIMUM WIDTH CURB CUT 11 GRADE TO DRAIN TO BIORETENTION CELL, SEE LANDSCAPING PLANS FOR TOPSOIL REQUIREMENTS. 12 NEW PARKING STALL STRIPING BIORETENTION CELL LAYOUT 2 SAVAGED WHEEL STOP INSTALLATION 2 TYPICAL AT 6 7 4A & 6 7 3 A SCALE: NTS N C17E SCALE: 1" = 5' C18E R-401453 C17F C18F IN COMPLIANCE WITH CITY OF RENTON STANDARDS iBergerABAMV3 CIVIL PERMIT SET DEVELOPMENT ENGINEERING + �� Ann Fowler 12/14/2018 CALL 48 HOURS BEFORE YOU DIG 33301 9th Avenue South, Suite 300 DESIGN BY: BERGERABAM DATE 10/22/2018 SURFACE WATER UTILITY 1- 800- 424- 5555 Federal Way, Washington 98003-2600 (206) 431-2300 Fax: (206) 431-2250 rstraka 12/14/2018 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE ACCEPTABILITY HL 10/09/18 STORM DETAILS C180242 O R G 10/09/18 ORIG MITIGATION HANGAR C180242 ABAM SPT 10/09/18 ��N P. T THIS DESIGN AND/OR CHECKED of WA3A, �i' SPT 10/09/18 SHEET SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE ENGINEER 10/09/18 TITLE MITIGATION HANGAR CHECKED C501-6E C45 RENTON SITE �o R 3'2" o ww JOB NO. COMP N0. APPROVED C 180242 APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. RTN-YD-0501-6E co CD Lf-) co CD O 00 T X, u t0 H