HomeMy WebLinkAboutR-401460It N O co N O c� U O 0 c: m E c m 0 a� c� cv J SITE SPECIFIC DATA PROJECT NUMBER 7606 PROJECT NAME BOEING MITIGATION HANGAR PROJECT LOCATION RENTON, WA STRUCTURE ID RTU-18 TREATMENT REQUIRED VOLUME BASED (CF) FLOW BASED (CFS) *0 409 TREATMENT HGL AVAILABLE (FT) N/A PEAK BYPASS REQUIRED (CFS) — IF APPLICABLE 2.176 PIPE DATA I.E. MATERIAL DIAMETER INLET PIPE 16.67 DI 12" OUTLET PIPE 15.20 HDPE 12" PRETREATMENT BIOFIL TRA TION DISCHARGE RIM ELEVATION 19.00 19.00 19.00 SURFACE LOAD 120 KIPS 120 KIPS 120 KIPS FRAME & COVER 36" X 36'; 36" X 74 (2) 36" X 74'; (2) 36" X 36 (2) 30 �, X 30 INDUSTRIAL MEDIA VOLUME (CY) 4.48 INDUSTRIAL MEDIA DELIVERY METHOD PER CONTRACT ORIFICE SIZE (DIA. INCHES) (2) 01.99" NOTES: *A TOTAL TREATMENT FLOW. OF TWO MWS UNITS WILL PROVIDE THE REQUIRED INSTALLATION NOTES NEENAH FOUNDRY R-3498—P2S SPRING ASSIST HATCH 1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT MATERIALS AND INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE MANUFACTURERS SPECIFICATIONS, UNLESS OTHERWISE STATED IN MANUFACTURERS CONTRACT: 2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE TO VERIFY PROJECT ENGINEERS RECOMMENDED BASE SPECIFICATIONS. J. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF CONCRETE. (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. ALL GAPS AROUND PIPES SHALL BE SEALED WATER TIGHT WITH A NON —SHRINK GROUT PER MANUFACTURERS STANDARD CONNECTION DETAIL AND SHALL MEET OR EXCEED REGIONAL PIPE CONNECTION STANDARDS. 4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING PIPES. 5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL RISERS, MANHOLES, AND HATCHES. CONTRACTOR TO GROUT ALL MANHOLES AND HATCHES TO MATCH FINISHED SURFACE UNLESS SPECIFIED OTHERWISE. 6. DRIP OR SPRAY IRRIGATION REQUIRED ON ALL UNITS WITH VEGETATION. 19.00 FLOW CONTROL RISER PATENTED VERTICAL NEENAH FOUNDRY NEENAH FOUNDRY NEENAH FOUNDRY R—J498—RJS SPRING PERIMETER R-3498—R2S SPRING UNDERORAIN R-3498—R3S SPRING ASSIST HATCH VOID AREA ASSIST HATCHES MANIFOLD ASSIST HATCH 17, 14 OUTFLOW PIPE DRAIN DOWN LINE PRE —FILTER SEE NOTES NEENAH FOUNDRY NEENAH FOUNDRY CARTRIDGE R-3498—R3S SPRING R-3498—R2S SPRING ASSIST HATCHES ASSIST HATCH INFLOW PIPE SEE NOTES PLAN VIEW NEENAH FOUNDRY INDUSTRIAL MEDIA R-3498—P2S BED C L SPRING ASSIST HATCH 16.49 lE IN 16.67 U" I® I I® I I® I I® I I® I lE OUT 16.28 15.20 WATER TABLE 10'-10" 12'-10" 15.20 DISCHARGE PRETREATMENT CHAMBER CHAMBER 6"— 24'-0" _6" 25'-0" ELEVATION VIEW GENERAL NOTES 1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED. 2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS AND ACCESSORIES PLEASE CONTACT MANUFACTURER. INTERNAL BYPASS DISCLOSURE: THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE ASSESSED TO ENSURE NO UPSTREAM FLOODING. PEAK HGL AND BYPASS CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY. THE PRODUCT DESCRIBED MAY BE PROPRIETARY AND CONFIDENTIAL: PROTECTED BY ONE OR MORE OF THE FOLLOWING US PATENTS: THE INFORMATION CONTAINED IN THIS DRAWING IS IHE SOLE No Clnl,,.ari 7, 425,262; 7, 470, J62, 7, 674, J78; PROPERTY OF MODULAR WETLANDS SYSTEMS. ANY 8,JOJ,816,- RELATED FOREIGN REPRODUC77ON IN PART OR AS A WHOLE WITHOUT THE WRITTEN P47ENTS OR OTHER PATENTS PENDING PERMISSION OF MODULAR WETLANDS SYSTEMS IS PROHIBITED. A FOrterra Company E i►i NEW I I IN11 1ell +4" 4'-0"--3'_8"-- LEFT END VIEW NEENAH FOUNDRY NEENAH FOUNDRY R-3498—R2S SPRING R-3498—R3S SPRING o ASSIST HATCH ASSIST HATCH ,I C/L 4 "-- �— A � J'-8",—4'-0"-- —8" 9'-4 " RIGHT END VIEW TREATMENT FLOW (CFS) 0.205 OPERATING HEAD (FT) 1.0 PRETREATMENT LOADING RATE (GPM/SF) 1.7 INDUSTRIAL MEDIA LOADING RATE (GPM/SF) 1.0 MWS-L -8-24- V- UG STORM WATER BIOFIL TRA TION SYSTEM STANDARD DETAIL NEAR MODULAR WETLAND SYSTEM RTU018 01-6A SCALE: NTS AIRCRAFT RATED HATCHES 72" X 36" DOUBLE NEENAH R-3498—R3S 62" X 36" DOUBLE EAST JOURDAN 8196—DOUBLE 36" X 36" SINGLE NEENAH R-3498—R2S 24" DIA ROUND NEENAH R-3492 NOTES: 1. ALL VAULT STRUCTURES AND ASSOCIATED ACCESS LIDS AND HATCHES SHALL MEET THE DESIGN LOADING REQUIREMENTS SHOWN ON SHEET C501-1 C. 2. THE LIFTING FORCE REQUIRED TO OPEN ACCESS LIDS AND HATCHES SHALL BE A MAXIMUM OF 35—POUNDS. HINGED LIDS AND ACCESS HATCHES SHALL BE EQUIPPED WITH A HYDRAULIC LIFT ASSIST SYSTEM AS REQUIRED TO MEET THE MAXIMUM LIFTING FORCE REQUIREMENTS. 3. MODULAR WETLAND FRAMES, HATCHES, AND LIDS SHALL BE AS SHOWN IN THE TABLE ABOVE OR ENGINEER APPROVED EQUAL. 4. SEE 501-5C FOR LID ELEVATIONS. 5. PERMANENT WATER QUALITY TREATMENT FACILITIES SHALL NOT BE USED TO CONVEY OR CONTAIN CONSTRUCTION STORM WATER. NEW FACILITIES SHALL BE KEPT OFFLINE UNTIL PROJECT IS COMPLETE. THE CONTRACTOR SHALL CLEAN AND FLUSH ALL PARTS OF THE SYSTEM PRIOR. SEE GENERAL NOTES ON SHEET C501-1A AND C501-113. 6. SEE STRUCTURAL PLANS FOR STRUCTURAL SUPPORT DETAIL. R-401460 IN COMPLIANCE WITH CITY OF RENTON STANDARDS iBergerABAM CIVIL PERMIT SET DEVELOPMENT ENGINEERING + CALL 48 HOURS V3 Ann Fowler 12/14/2018 BEFORE YOU DIG 33301 9th Avenue South, Suite 300 DESIGN BY: BERGERABAM DATE 10/22/2018 SURFACE WATER UTILITY 1— 800— 424— 5555 Federal Way, Washington 98003-2600 rstra a 12/14/2018 (206) 431-2300 Fax:(206) 431-2250 DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY HL 10/09/18 STORM DETAILS C180242 O R G 10/09/18 ORIG MITIGATION HANGAR C180242 ABAM SPT 10/09/18 ��N P. T THIS DESIGN AND/OR CHECKED of WA3A, �i' SPT 10/09/18 SHEET SPECIFICATION IS APPROVED ""A �ff" APPROVED BY DEPT. DATE BEENEER 10 18 TITLE MITIGATION HANGAR CHECKED C501-6N C53 STf RENTON SITE �o R 31271 o ww JOB NO. COMP NO. L��SIONAL �APPROVED C 180242 APPROVED CIVIL MASTER SITE RENTON, WA DWG NO. RTN—YD—0501-6N C-0 C) LO M O 00 T �u , I 04 00 T Q J w H 1-�