HomeMy WebLinkAboutR-401472GENERAL NOTES 0 6 L1J N 00 0 N C U O E 0 c 0 0 ca (f) C11E BUILDING CONNECTION NORTH SCALE: 1 " = 10' PROTECT EXISTING 8" WATER PROPOSED FIRE HYDRANT ASSEMBLY M501-1 D N-185536.30 E-1300246.80 1 - 12"x6" CUT -IN TEE • • CONNECTION TO EXISTING N-185525.02 E-1300202.22 • \ F PROF FW 45 LF 6" DI FIRE NEW 30" STORM ERE HYDRANT CONNECTION DETAIL C12E SCALE: 1 " = 10' 4), Ber erABAM CALL 48 HOURS � BEFORE YOU DIG 33301 9th Avenue South, Suite 300 1-800-424-5555 Federal way, Washington 98003-2600 (206) 431-2300 Fax:(206) 431-2250 SYM REVISION BY APPROVED DATE ORIG MITIGATION HANGAR C180242 ABAM I SPT 10/09/18 SYM EW BUILDING -87 REVISION JL LI I V UI OVE BLIND FLANGE AND NECT TO 10" FLUSH PIV INSTALL 8" BLIND FLANGE AT TEMPORARY CONNECTION BUILDING CONNECTION SOUTH C12E SCALE: 1" = 10 UA--_D J n 1 - 8"x6" CUT -IN TEE CONNECTION TO EXISTING INSTALL BLIND FLANGE (NORTH) N-185268.67 E-1300356.90 PROTECT EXISTING 12" STORM cn PROTECT EXISTING \ 15" STORM C13E BY I APPROVED 1 PROPOSED FIRE HYDRANT ASSEMBLY M501-1 D N-185281.10 E-1300396.82 EXISTING 8" FIRE MAIN • TO BE ABANDONED • SEE REMOVAL PLANS W� PROPOSED BOLLARD PROTECTION (TYP) PROTECT EXISTING LIGHT POLE AND JUNCTION BOX 42 LF 6" DI FIRE ERE HYDRANT CONNECTION DETAIL_ SCALE: 1 " = 10' DATE P. of WA �f ® D BOE//V� � x 31271 w� ��ssioNaL 200' SHORELINE SET BACK CONNECT TO APRON R FIRE SYSTEM WITH 6" DI PROPOSED BOL PROTECTION (T ERE HYDRANT CONNECTION DETAIL C11 E SCALE: 1 " = 10' CONNECTION TO EXISTING 1 - 6" 45° BEND 6" DI SPOOL AS REQUIRED N-185067.26 E-1300478.22 Ij 33 LF 6" DI FIRE \ b PROPOSED FIRE HYDRANT ASSEMBLY M501-1 D N-185035.96 E-1300497.60 LXIJIIINIi HTUKAINI IU BE REMOVED $ PROPOSED BOLLARD PROTECTION (TYP) / ERE HYDRANT CONNECTION DETAIL C 13E SCALE: 1 " = 10' CIVIL PERMIT SET V3 DESIGN BY: BERGERABAM DATE 10/22/2018 DRA1 ACCEPTABILITY HL THIS DESIGN AND/OR CHE SPECIFICATION IS APPROVED SPT ENG APPROVED BY DEPT. I DATE BEE 1. SEE SHEET C501-1A FOR FIRE AND WATER SERVICE NOTES. 2. ALL FIRE LINE SHALL BE INSTALLED WITH RESTRAINED JOINTS. 3. SEE SHEET M501-1 D DETAIL 3 FOR TYPICAL UTILITY TRENCH BEDDING AND BACKFILL. 4. COORDINATE ALL DOMESTIC WATER AND FIRE WATER SHUT DOWNS REQUIRED FOR CONNECTIONS TO EXISTING WITH BOEING SITE SERVICES AND FIRE DEPARTMENT. 5. FITTINGS SHOWN FOR CONNECTIONS TO EXISTING ARE SUGGESTED. CONTRACTOR SHALL POTHOLE AND FIELD VERIFY PIPE TYPE, LOCATION, CONDITION AND ROUNDNESS PRIOR TO ORDERING MATERIALS. 6. HORIZONTAL CONTROL NOTES SHOWN ON THIS SHEET REPRESENT CENTER OF STRUCTURE, BEND OR CENTERLINE OF PIPE. 7. HORIZONTAL DATUM: WASHINGTON STATE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983(91). VERTICAL DATUM: NATIONAL GEODETIC VERTICAL DATUM 1929 (NGVD29). VERTICAL DATUM CONVERSION: NGVD29 TO THE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD88) = NGVD29 + 3.60 FEET. 8. THERE SHALL BE NO EXPOSED GALVANIZED MATERIALS, COATINGS OR ZINC APPLIED SURFACE TREATMENTS ON ANY EXTERIOR OR UNDERGROUND MATERIALS OR SURFACES. ALL GALVANIZED OR ZINC APPLIED MATERIALS OR COATINGS SHALL BE PERMANENTLY PAINTED OR COATED TO PREVENT EXPOSURE OF THE GALVANIZED/ZINC MATERIALS PRIOR TO INSTALLATION OR COMPLETION OF CONSTRUCTION. 9. UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL DUCTILE IRON PIPING AND FITTINGS SHALL HAVE FLEXIBLE BOLTLESS RESTRAINED JOINTS, WITH A MECHANISM THAT PROVIDES A POSITIVE AXIAL LOCK BETWEEN THE BELL AND THE SPIGOT TO RESTRAIN THE JOINT. TR-FLEX BY U.S. PIPE, OR APPROVED EQUIVALENT. TR-FLEX GRIPPER RING BY U.S. PIPE SHALL BE USED TO RESTRAIN FIELD CUT PIPE, PER MANUFACTURER'S INSTRUCTIONS. 10. BOLLARD PROTECTION FOR ABOVE GRADE UTILITIES SHALL BE PER DETAIL 5 ON SHEET M501-51D WITH SPACING PER DETAILS 1 AND 2 ON SHEET M501-51D. 11. PERMANENT FIRE SYSTEM IMPROVEMENTS TO BE CONSTRUCTED PRIOR TO BEGINNING PRELOAD CONSTRUCTION ACTIVITIES ARE SHOWN ON SHEET M501-1A. SEPARATE FIRE PERMITS REQUIRED FROM RENTON REGIONAL FIRE AUTHORITY 1AI L SUBTITLE 10 09 18 10 09 18 10/09/18 TITLE CIVIL MASTER PERMANENT UTILITY DETAILS MITIGATION HANGAR RENTON SITE SITE S-401412 W-401412 R-401472 1 IN COMPLIANCE WITH CITY OF RENTON STANDARDS I..VLLLIVI IC180242 JIIVIUVLO R G "" 10/09/18 SHEET M501 -1 C M03 JOB NO. COMP NO. C180242 RENTON, WA DWG NO. RTN—YD—M501-1 C