HomeMy WebLinkAboutP_CAD_N.207384_v1CONSTRUCTION NOTES,
1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO
TRENCHING OR DIGGING.
2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS
WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF
THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THE
ACTUAL LOCATION AND NATURE OF THE UNDERGROUND
FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT
SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TO
EXCAVATION.
3. FOR UNDERGROUND ACTIVITY, TEST AND VENTILATE
MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING
DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND
USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL,
STATE, AND LOCAL REGULATIONS.
4. ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE
TO THE CODE OF FEDERAL REGULATIONS (CFR) 1926.650
SUBPART P.
a. PROVIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF
EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.
b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24' EDGE OF
PIT OR TRENCH.
c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC
SAFETY, ALL BARRICADES MUST BE EQUIPPED WITH FLASHING
LIGHTS FOR NIGHT VISIBILITY.
d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE
SHORING FOR WALL STABILITY.
5. TRENCH COVER IS TO BE 36' MINIMUM AND FREE OF ROCKS,
DEBRIS, AND CLODS, THE TRENCH IS TO BE A MINIMUM OF
36' COVER IN DEVELOPED AREAS AND A MINIMUM OF 48' OF
COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESE
STANDARDS WILL BE SPECIFIED ON THE PLANS.)
6. ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED,
DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION
SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER.
7. NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING.
8. ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.
9, BOND BURIED/AERIAL FACILITIES AS REQUIRED BY
JURISDICTIONAL AGENCY(S).
10, AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING
WORK PER STATE AND LOCAL REGULATIONS.
11, ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO
BE WITH APPROVED WARNING DEVICES AND PLACED PER
STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC
WORKS ENGINEERING DEPARTMENT STANDARDS AND
SPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN
SHALL BE SUBMITTED TO THE REQUESTING PERMITTING
AGENCY, PRIOR TO BEGINNING WORK, PERMITTING AGENCIES
MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTION
ACTIVITIES.
12. EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS
SHALL BE MAINTAINED AT ALL TIMES. AS NECESSARY,
TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS
SHALL BE PROVIDED AND MAINTAINED PER STATE
DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS
ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS.
13. THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE
VERIFIED PRIOR TO CONSTRUCTION.
THIS JOB WILL PLACE NEW EQUIPMENT AT 620 S 7TH ST, RENTON.
NOTE, THIS JOB IS AN IPC, PLEASE CONTACT FIELD ENGINEER WITH ANY QUESTIONS OR CONCERNS - CORY COATE 503-961-5023
FIBER:
CTL WILL PLACE APPROX. 1363 TOTAL FIBER AND INNERDUCT.
CTL WILL ACCESS VAULTS MH3-207.1, MH3C-293, HH UN -166, AND CUST SERVING HH UN -165 TO PLACE AND SPLICE FIBER. CTL
WILL PLACE 1X16 SPLITTER IN MH293.
CTL WILL ATTEMPT TO PLACE APPROX. 350 FEET OF FIBER AND INNERDUCT FROM CUSTOMER SERVING HH UN -165 TO THE CUST
MPOP IN A 2INCH CONDUIT ALONGSIDE WHAT LOOKS TO BE LIKE A 100 PAIR CABLE. IF CTL IS NOT SUCCESSFUL CUSTOMER WILL
WANT TO WORK WITH CTL ENGINEER TO LOOK AT OPTIONS TO CREATE A NEW PATH INTO THEIR BLDG.
ALSO NOTE CTL WILL ATTEMPT TO PLACE CAT5E CABLE FROM IST FLOOR TELCO ROOM TO THE CUSTOMERS 2ND FLOOR
SERVER ROOM APPROX. 125 FEET. NOTE, THIS PATH HAS TWO HOLES 1 -HOLE IN THE WALL AND THE OTHER IN THE CEILING AS A
RISER TO THE 2ND FLOOR, THESE HOLES ARE PACK WITH EXISTING CATS CABLE.
CenturyLinkr-
All Underground Utility Locations Shown Hereon Are
Approximate.Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
NEW IPC JOB USE FW# N.207384
POF MH 207 LRE 14,15 / PLACE NEW 24CT FROM MH 207, TO MH 293, PLACE 1X16 SPLITTER IN MH 293,
PLACE NEW 24CT FROM MH 293 THRU HH UN -166, THRU HH UN -165 TO CUST MPOP
CUSTOMER:
WILL WANT TO PROVIDE A NEW 4'X4' 3/41NCH BACK BOARD ON THE NORTH WALL OF 1ST FLOOR
TELCO ROOM.
CALL TWO WORKING DAYS
BEFORE YOU DIG
Q 811
PLOTTED: 03/23/2017 BY: PHILLIP PRICE
NOTICE - NOT FOR DISCLOSURE OF
620 S. 7TH STREET
RENTON, WA 98057
DRAFTED BY: KILLION COMM.
FIELD ENGINEER: CORY COATE
(503)-961-5023
23N I 5E 1 18
AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
GEO CODE:
WC CLLI: RNTNWA01
SH 1 OF 3
PERMITS
YES/NO
VICINITY MAP
DESIGNED SERVICES:
❑
HELD ORDERS:
❑
ROW REQUIRED:
❑
®
❑
CITY:
;.
8
©
COUNTY:
❑
❑
I�
STATE:
Dojo3Q
Renton City j
8 Municipal COurt®
RAILROAD:
❑
I
LOOP QUAL.:
❑
11127111
WORK LOCATION
620 S 7TH ST.
620 South 7th Str«t
PREMIS FORM:
❑
I
CONFORMANCE TEST:
®
❑
CarWashSEEJDS
(Briownar
vron
ERFS DATE:
lOSam's Club
TRENCH OPEN DATE:
ARCMH-207
APPROVED MNEMONICS:
f
of
ASSOCIATED PROJECTS:
!y �1
Triton Tower One
NOTE, THIS JOB IS AN IPC, PLEASE CONTACT FIELD ENGINEER WITH ANY QUESTIONS OR CONCERNS - CORY COATE 503-961-5023
FIBER:
CTL WILL PLACE APPROX. 1363 TOTAL FIBER AND INNERDUCT.
CTL WILL ACCESS VAULTS MH3-207.1, MH3C-293, HH UN -166, AND CUST SERVING HH UN -165 TO PLACE AND SPLICE FIBER. CTL
WILL PLACE 1X16 SPLITTER IN MH293.
CTL WILL ATTEMPT TO PLACE APPROX. 350 FEET OF FIBER AND INNERDUCT FROM CUSTOMER SERVING HH UN -165 TO THE CUST
MPOP IN A 2INCH CONDUIT ALONGSIDE WHAT LOOKS TO BE LIKE A 100 PAIR CABLE. IF CTL IS NOT SUCCESSFUL CUSTOMER WILL
WANT TO WORK WITH CTL ENGINEER TO LOOK AT OPTIONS TO CREATE A NEW PATH INTO THEIR BLDG.
ALSO NOTE CTL WILL ATTEMPT TO PLACE CAT5E CABLE FROM IST FLOOR TELCO ROOM TO THE CUSTOMERS 2ND FLOOR
SERVER ROOM APPROX. 125 FEET. NOTE, THIS PATH HAS TWO HOLES 1 -HOLE IN THE WALL AND THE OTHER IN THE CEILING AS A
RISER TO THE 2ND FLOOR, THESE HOLES ARE PACK WITH EXISTING CATS CABLE.
CenturyLinkr-
All Underground Utility Locations Shown Hereon Are
Approximate.Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
NEW IPC JOB USE FW# N.207384
POF MH 207 LRE 14,15 / PLACE NEW 24CT FROM MH 207, TO MH 293, PLACE 1X16 SPLITTER IN MH 293,
PLACE NEW 24CT FROM MH 293 THRU HH UN -166, THRU HH UN -165 TO CUST MPOP
CUSTOMER:
WILL WANT TO PROVIDE A NEW 4'X4' 3/41NCH BACK BOARD ON THE NORTH WALL OF 1ST FLOOR
TELCO ROOM.
CALL TWO WORKING DAYS
BEFORE YOU DIG
Q 811
PLOTTED: 03/23/2017 BY: PHILLIP PRICE
NOTICE - NOT FOR DISCLOSURE OF
620 S. 7TH STREET
RENTON, WA 98057
DRAFTED BY: KILLION COMM.
FIELD ENGINEER: CORY COATE
(503)-961-5023
23N I 5E 1 18
AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
GEO CODE:
WC CLLI: RNTNWA01
SH 1 OF 3
AERIAL LEGEND
EXISTING EQUIPMENT LEGEND
AMC
ANCHOR
--- -=------- --- _ ----- --- EDGE OF PAVEMENT
;o, TELEPHONE BULLET PEDESTAL O
ELECTRIC PEDESTAL/CABINET
A GAS METER
CA ARM
CABLE ARM
— C/L — CENTERLINE
® TELEPHONE REPEATER
ava
ELECTRIC TRANSFORMER
2 GAS VALVE
CATV
CABLE TV
- R/W- - R/W- RIGHT OF WAY
® TELEPHONE PEDESTAL
CID
ELECTRIC METER
G1 WATER METER
P/L PROPERTY LINE
TO TELEPHONE VAULT/HANDHOLE �
ELECTRIC VAULT/HANDHOLE
® WATER VALVE
DG
DOWN GUY
— — — — — — — — — — EASEMENT
TELEPHONE CABINET
QT
ELECTRIC MANHOLE
-5 FIRE HYDRANT
DGA
DOUBLE GUARD ARM
- __-_.- ,---_ -•------_---_---- CURB & GUTTER
®T TELEPHONE MANHOLE
e
ELECTRIC J-BOX
® WATER MANHOLE
----- ,--- "- -- - RAILROAD
® TELEPHONE COOL PED
Q
SEWER MANHOLE
[A IRRIGATION METER
FGA
FIBER GLASS ARM
------ -< -- - - -- - - FENCE
EI TELEPHONE SAI
®
STORM DRAIN CATCH BASIN
® IRRIGATION VALVE
F/S
FIELD SIDE
— - - -TEL- - - -TEL- - - -TEL— TELCO
MR TELEPHONE USAM
® STORM DRAIN INLET
CULVERT
GA
GUARD ARM
ELEC ELECTRIC
O TELEPHONE OWNED POLE
®
SEWER DRAIN MANHOLE
-- TRAFFIC SIGNAL VAULT/HANDHOLE
CATV CATV
® JOINT USE POLE
C/L MONUMENT
�_�; TRAFFIC SIGNAL POLE
HOA
HEIGHT OF ATTACHMENT
-------- - - GAS
Q CATV BULLET PEDESTAL
®
POLE ITEM NO.
STREETLIGHT
M/R
MAKE READY
TRAFFIC SIGNAL
Evj CATV PED
OHG
OVERHEAD GUY
WATER WATER — WATER
F-TV-1 CATV VAULT/HANDHOLE
— SEWER SEWER — SEWER
R/S
ROAD SIDE
STORM STORM STORM
SLAN
LIGHT OR POWER COMPANY INVENTORY NUMBER
IRRIG IRRIG IRRIGATION
SWA
SIDEWALK ANCHOR AND GUY
T
TELEPHONE
TERM
TERMINAL
TRANS
TRANSFORMER
PROPOSED
EQUIPMENT
LEGEND
TAPE &
SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP
SECONDARY POWER CABLES AND/OR
TOP OF RISER
CABLES SO PROPOSED CABLE CAN BE ATTACHED
- - - - - - - - - - - - - - - - PARKWAY TRENCH
® 2'x2' RECEIVING PIT
>- ANCHOR & DOWN GUY
WITHOUT VIOLATING THE 40' RULE.
® 4'x4' RECEIVING PIT
DOWN GUY
BORE
CABLE
ARM ATTACHMENT LOCATIONS
X7, SAI
xxx• ASPHALT TRENCH FOOTAGE
TF
TOP FIELD SIDE
ASPHALT TRENCH
® COOL PEDESTAL
xxx' I DIRT OR S/W TRENCH FOOTAGE
TS
TOP STREET SIDE
BORE FOOTAGE
F-E-1 ELECTRIC PEDESTAL
x x-)-rj
TIP
TOP INSIDE POSITION
AERIAL BUILD
OT TELCO HANDHOLE
xxx• AERIAL FOOTAGE
TIS
TOP INSIDE STREET SIDE
AERIAL
® TELCO PEDESTAL
TMP
TOP MIDDLE POSITION
SLACK PAND
OT TELCO CABINET
TOP
TOP OUTSIDE POSITION
Al A ERIAL STRAND
TELCO MANHOLE
TOS
TOP OUTSIDE STREET SIDE
BF
BOTTOM FIELD SIDE
BS
BOTTOM STREET SIDE
BIP
BOTTOM INSIDE POSITION
BIS
BOTTOM INSIDE STREET SIDE
BMP
BOTTOM MIDDLE POSITION
BOP
BOTTOM OUTSIDE POSITION
Bos
BOTTOM OUTSIDE STREET SIDE
FIELD ENGINEER: CORY COATE
(503}961-5023
TOWN: RANGE: SECT:
23N 5E 18
All Underground Utility Locations Shown Hereon Are
NOTICE - NOT FOR DISCLOSURE OF CENTURYLINK AND AFFILIATES
EXCEPT UNDER WRITTEN AGREEMENT
JOB: N.207384
�� Approximate.Construction Contractor Is Responsible CALL TWO WORKING DAYS
For The Location Of Municipal And Private Utilities BEFORE YOU DIG
44
e n t U ry L 1 n R n
620 S. 7TH STREET
RENTON, WA 98057
CODE:
GEO CODE:
811
WC RNTNWA01
WC
PLOTTED: 03/23/2017 BY: PHILLIP PRICE
SH 2 OF 3
DRAFTED BY: KILLION COMM.
I
----/L3 -- c/L --- —
MH3T61E r STA.0+00
r STA. +07
- -.--- STA. +11
V
o I
0 161' CTL DUCT
N
M
N
7STA1+30
I
J
u
STA. [1 +46
10'
HH UN -2 o -T7 STA. 1+59 0 0
N N N
M M th
n n �
128' CTL �~ 5'
DUCT -
STA. 2+73 T.
STA. 2+77
10'
112' CTL DUCT
C/L -- C/L --- —
115' CTL DUCT
STA. 2+98
o rn
0
0 0
Q
I�
r�
v1
CenturyLink
C/L
3
HH514
60'
C/
/W_
#1rj6Z14AfS A PE S
-HH528 LID NOT ABLE TO
OPEN ALL WAY
C/L
-TRENCH 2'1-2" DUCT TO
BORE PIT
-CTL TO REMO 16'X10' SIDEWALK
PANEL AT DRIVE WAY OF 538 ALSO
REPLACE
C/L ---
C/L
W
-NOTE THIS PROPOSED BORE WILL
HAVE TO BE LOOKED AT BY ROW DEPARTMENT
LOOKS LIKE HH UN -165 IS ON CITY OF RENTON
PROPERTY KING COUNTY GIS
O
p
N
O
N
N N !n
\
FQ-
tn
-PL 1233' OF I.D. AND
FIBER TOTAL
BORE 1-2" DUCT 346'
p
to
N
N
h
N
O
N
O
N
O
O
N
r
r
r
N
N
N
n
r
N
a
HH540-1 , BORE PIT
8' 9' r
HH UN -165
1 r 111 O
_-- -I HH520 I HH528
8 ADA RAMP
108' CTL DUCT 153' CTL DUC 110' CTL DUCT + rn
— C/L C/L + N
BURYVETT APES `� �' CO
All Underground Utility Locations Shown Hereon Are
Approximate.Constructlon Contractor Is Responsible
For The Location Of Municipal And Private Utilities
CALL TWO WORKING DAYS
BEFORE YOU DIG
Q 811
NOTICE - NOT FOR DISCLOSURE OF
620 S. 7TH STREET
RENTON, WA 98057
FIELD ENGINEER: CORY COATE
(503)-961-5023
23N I 5E 1 18
AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
GEO CODE:
WC CLLI: RNTNWA01
11 1 PLOTTED: 03/23/2017 BY: PHILLIP PRICE I DRAFTED BY: KILLION COMM. I - SH 3 OF 3 11
N
N N !n
\
FQ-
tn
-PL 1233' OF I.D. AND
FIBER TOTAL
All Underground Utility Locations Shown Hereon Are
Approximate.Constructlon Contractor Is Responsible
For The Location Of Municipal And Private Utilities
CALL TWO WORKING DAYS
BEFORE YOU DIG
Q 811
NOTICE - NOT FOR DISCLOSURE OF
620 S. 7TH STREET
RENTON, WA 98057
FIELD ENGINEER: CORY COATE
(503)-961-5023
23N I 5E 1 18
AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
GEO CODE:
WC CLLI: RNTNWA01
11 1 PLOTTED: 03/23/2017 BY: PHILLIP PRICE I DRAFTED BY: KILLION COMM. I - SH 3 OF 3 11