Loading...
HomeMy WebLinkAboutP_CAD_N.259330_170620_v1CONSTRUCTION NOTES, 1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO PERMITS TRENCHING OR DIGGING, VICINITY MAP N 2, THE EXISTENCE AND LOCATION OF ANY UNDERGROUND YESINO UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF SERVICES: ❑ THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THE POF MH523DESIGNED MH19 --iL— ACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT f HELD ORDERS: ❑ SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TOMH553 Re: EXCAVATION, cu i 3. FOR UNDERGROUND ACTIVITY, TEST AND VENTILATE CO HH ROW REQUIRED: ❑ MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND m 6th S*. K 6th 'it F. USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, ® ❑ STATE, AND LOCAL REGULATIONS. G y 0 CITY: 4. ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE o service m The Boeing Company, TO THE CODE OF FEDERAL REGULATIONS (CFR) 1926,650 MH18 z 10-16DOlding ❑ SUBPART P. COUNTY: a. PROVIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF ° z EXCAVATION FOR TECHNICIAN INGRESS/EGRESS. {_7 - ❑ b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24' EDGE OF STATE: PIT OR TRENCH. WORK LOCATION c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY, ALL BARRICADES MUST BE EQUIPPED WITH FLASHING 540 GARDEN AVEN Kenworth Truck OCompany- Renton.. RAILROAD: ❑ LIGHTS FOR NIGHT VISIBILITY, d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE Prang Thai 0 v 5, SHORING FOR WALL STABILITY, TRENCH COVER IS TO BE 36' MINIMUM AND FREE OF ROCKS, a E� LOOP QUAL.: ❑ DEBRIS, AND CLODS. THE TRENCH IS TO BE A MINIMUM OF A c 36' COVER IN DEVELOPED AREAS AND A MINIMUM OF 48' OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESE " Z PREMIS FORM: ❑ STANDARDS WILL BE SPECIFIED ON THE PLANS.) 6 ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION ® ❑ CONFORMANCE TEST: SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. 0All About Auto Collision 7. NORMAL/ GUIDED-B❑RING METHOD RECOMMENDED WHEN BORING. SEE NDS B. ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED. 9. BOND BURIED/AERIAL FACILITIES AS REQUIRED BY 0Jeffs Auto Repair J & R Metal JURISDICTIONAL AGENCY(S), ERFS DATE: 10. AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING WORK PER STATE AND LOCAL REGULATIONS, TRENCH OPEN DATE: 11. ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO BE WITH APPROVED WARNING DEVICES AND PLACED PER N hth S: SI r... APPROVED MNEMONICS: STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC ASSOCIATED PROJECTS: WORKS ENGINEERING DEPARTMENT STANDARDS AND17, SPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTED TO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK, PERMITTING AGENCIES SCOPE OF WORKPLACE FDP AND ClENA ON EAST WALL MPOP B.B. ON THE 2ND FLOOR LCON NAME AND NUMBER: MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTION FIBER: MH 523 LGO06, 31-32 / PLACE NEW 24CT FROM MH 523 THRU MH 19, THRU MH 18, THRU MH DAN SPRAGUE 262-564-7205 12, ACTIVITIES, EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS 553. WE WILL BE USING EXISTING 4" DUCT FOR THIS PORTION OF THE JOB. SHALL BE MAINTAINED AT ALL TIMES. AS NECESSARY, AFTER 553 WE WILL BE BORING EAST ON N. 6TH ST. MH 553 IS RIGHT ON THE EDGE OF A EXISTING TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS S/W RAMP AND THIS RAMP WILL NEED TO BE REMOVER TO TRENCH OUTTO A BORE PIT. AFTER BORE FIBER ENGINEER: SHALL BE PROVIDED AND MAINTAINED PER STATE MICHAEL GILLIAM DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS AND TRENCH IS COMPLETE REPLACE RAMP PER CITY OF RENTONS SPECS. ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS. PLACE A RECEIVING/BORE PITJUST BEFORE AVE IN THE S/W, 15X4' S/W TILE WILL NEED TO BE 13, THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIOR TO CONSTRUCTION, REMOVED AND THEN RESTORED AFTER THE BORE IS COMPLETE. CUSTOMER NAME: PLACE A BORE PIT ON THE EAST SIDE OF GARDEN AVE JUST ACROSS THE STREET FROM THE PREVIOUS ATC LEASING COMPANY, LLC CUSTOMER: N/A j TW CenturyLink- All Underground Utility Locations Shown Hereon Are Approximate. Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities PIT TO SHOOT UNDER GARDEN AVE. AT THIS BORE PIT A NEW 1248PED WILL NEED TO BE PLACED AFTER BORE IS COMPLETE TO BE ABLE TO BORE SOUTH ON GARDEN. PLACE THE FINAL RECEIVING PIT NEAR EXISTING UP1248 PED TO ACCESS WHERE I BELIEVE THE CBO STARTS. AFTER BORE IS COMPLETE PLACE A NEW BIG SHOT PED TO INSURE CAPTURE ALL CONDUITS IN THIS PED. CURRANTLY THERE ARE 6-4" FROM HERE USE EXISTING 4" CBO TO PULL FIBER THRU TO MPOP. PLACE 1-1.25" I.D. IN THE EXISTING 4" DUCTS AND PLACE 3-1.25" LD IN ALL NEW 4" DUCT. ***RECORDS DOSE NOT SHOW ANY CBO FEEDING ANY BUILDINGS ON THIS PARCEL. HOWEVER I FIND 2-4" IN THE MPOP AND AGAIN IN THE PARKINGLOT C.O. HH. CABLES APPEAR TO BE THE SAME IN BOTH PLACES. HOW EVER I BELIEVE ONLY 1 OF THESE 4" MAKES IT TO OUR UP1248 PED. CALL TWO WORKING DAYS BEFORE YOU DIG 81 1 PLOTTED: 06/08/2017 BY: SARAH THATCHER 540 GARDEN AVE N RENTON, WA 98057 DRAFTED BY: KILLION COMM. CUSTOMER ADDRESS: 540 GARDEN AVE N RENTON, WA 98057 FIELD ENGINEER: PATRICK MARKS (503)-347-1137 TOWN: RANGE: SECT: 23N I 5E 1 8 JOB: N. 259330 GEO CODE: WC CLLI: RNTNWA01 SH 1 OF 3 AERIAL LEGEND ANC ANCHOR CA ARM CABLE ARM CATV CABLE TV DG DOWN GUY DGA DOUBLE GUARD ARM FGA FIBER GLASS ARM F/S FIELD SIDE GA GUARD ARM HOA HEIGHT OF ATTACHMENT M/R MAKE READY ❑HG OVERHEAD GUY R/S ROAD SIDE SLAN LIGHT OR POWER COMPANY INVENTORY NUMBER SWA SIDEWALK ANCHOR AND GUY T TELEPHONE TERM TERMINAL TRANS TRANSFORMER TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP SECONDARY POWER CABLES AND/OR TOP OF RISER CABLES S❑ PROPOSED CABLE CAN BE ATTACHED WITH❑UT VIOLATING THE 40' RULE. CABLE ARM ATTACHMENT L OCATION TF TOP FIELD SIDE TS TOP STREET SIDE TIP TOP INSIDE POSITION TIS TOP INSIDE STREET SIDE TMP TDP MIDDLE POSITION TOP TOP OUTSIDE POSITION TOS TOP OUTSIDE STREET SIDE BF BOTTOM FIELD SIDE BS BOTTOM STREET SIDE BIP BOTTOM INSIDE POSITION BIS BOTTOM INSIDE STREET SIDE BMP BOTTOM MIDDLE POSITION BOP BOTTOM OUTSIDE POSITION B❑S BOTTOM OUTSIDE STREET SIDE CenturyLink­ I EXISTING EQUIPMENT LEGEND EDGE ❑F PAVEMENT (0 TELEPHONE BULLET PEDESTAL =) ELECTRIC PEDESTAL/CABINET C/L CENTERLINE (D TELEPHONE REPEATER FP R] ELECTRIC TRANSFORMER -R/W- -R/W- RIGHT OF WAY ® TELEPHONE PEDESTAL CD ELECTRIC METER P/L PROPERTY LINE F HH TELEPHONE VAULT/HANDHOLE BORE FOOTAGE ELECTRIC VAULT/HANDHOLE - — — — — -- - - — -- — EASEMENT AERIAL FOOTAGE TELEPHONE CABINET Q ELECTRIC MANHOLE - = = CURB & GUTTER ® TELEPHONE MANHOLE B ELECTRIC J-BOX RAILROAD M -N TELEPHONE COOL PED OS SEWER MANHOLE -x x x X X FENCE F1 X71 TELEPHONE SAI STORM DRAIN CATCH BASIN — - - -TEL - - - - TEL- - - - TEL-- TELCO sA TELEPHONE USAM ® STORM DRAIN INLET ELEC ELECTRIC O TELEPHONE OWNED POLE ® SEWER DRAIN MANHOLE CATV CATV ® JOINT USE POLE OO C/L MONUMENT GAS ® CATV BULLET PEDESTAL ® POLE ITEM NO. - - TRAFFIC -- -- - TRAFFIC SIGNAL FT vj CATV PED - -- WATER WATER WATER Tv CATV VAULT/HANDH❑LE SEWER SEWER SEWER STORM STORM STORM IRRIG IRRIG IRRIGATI❑N PROPOSED EQUIPMENT LEGEND - - - - - - - - - - - - - - - - PARKWAY TRENCH .......................... All Underground Utility Locations Shown Hereon Are Approximate.Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities AERIAL BUILD AERIAL BUILD SLACK SPAN AERIAL STRAND CALL TWO WORKING DAYS BEFORE YOU DIG 811 GAS METER GAS VALVE Q WATER METER ® WATER VALVE FIRE HYDRANT ® WATER MANHOLE Q IRRIGATION METER ® IRRIGATION VALVE �< CULVERT rs TRAFFIC SIGNAL VAULT/HANDH❑LE Q TRAFFIC SIGNAL POLE ® STREETLIGHT ® 2'x2' RECEIVING PIT > ANCHOR & DOWN GUY ® 4'x4' RECEIVING PIT do DOWN GUY Fix -11 SAI xxx• ASPHALT TRENCH FOOTAGE ® COOL PEDESTAL xxx' DIRT ❑R S/W TRENCH FOOTAGE 0 ELECTRIC PEDESTAL Fx-x-)-cl BORE FOOTAGE F -H -H-1 TELCO HANDH❑LE xxx' AERIAL FOOTAGE ® TELCO PEDESTAL U TELCO CABINET TELCO MANHOLE PLOTTED: 08/08/2017 BY: SARAH THATCHER 040 GARDEN AVE N RENTON, WA 98057 DRAFTED BY: KILLION COMM. JOB: N. 259330 GEO CODE: WC CLLI: RNTNWA01 SH 2 OF 3 I MH523 41 STA. 0+00 PLACE 24X FIBER E/W 1-1.25 4' 1 I I.D. IN EXISTING 4" DUCT 803' t ' 31Dk j D!W MH 19 STA. 0+80 24' U .r �1 10, MH553 IS RIGHT ON THE o EDGE OF EXISTING RAMP I I Y 3 REMOVE AND REPLACE-� SIW RAMP PER CITY OF I i RENTONS SPEC'S Ln N 662' 0 TRENCH 10' FROM MH553 TO RECEIVING PIT AND L) M PLACE 4" DUCT E/W 24X W �� FIBER AND 1-1.25 I.D. oc Lo Co: I REMOVE 1 S/W U)i TILE 5'X4' RES_TO E I —B/W WHEN COM ME 32' T BORE PIT -- RA 35' 12 TN'. 8+12 STA. 11+72 ST4. 7+27 � 13' MH18 25 MPH -04C/L Cf�L - C/L - �' N 6TH BORE PIT ,ST * R/W- - R/W- BORE AND PLACE 600' OF o 4" DUCT ENV 3-1.25 I.D. AND 24X FIBER 90 � I � 5 T-1 PARCEL #7564600055 535 GARDEN AVE N I � I I *RECORDS AND GOOGLE BOTH SHOW OUR CUSTOMER \ u @ THIS ADDRESS. BUT THIS IS I 500 PARK AVE N "BOEING" I 3 a. I Ld CenturyLink- ***RECORDS ARE NO HELP FOR THIS PROPERTY*** **2240' TOTAL FIBER** PARCEL#7223000010 BORE PIT PLACE UP1248 WHEN BORE COMPLETE JR/W- -R/W- —R/W— -R/W- STA. 12+48 EDP - PRIVATE DRIVE 70' C/L C/L C/L - L STA. 14+18 STA. 14+13 LO © UP1248 REPLACE cn WI BIGSHOT 8 BORE PIT Y Y Ld 70' All Underground Utility Locations Shown Hereon Are Approximate. Construction Contractor Is Responsible For The Location Of Municipal And Private Utilities 45' -------EDP -�`,P -- CO CO HH C� U) STA. 16+71 —R/W— PARKIN(-' CUSTOMER/CTL TO ROD AND PROVE FROM CO HH TO UP 1248 APPROX 253' CALL TWO WORKING DAYS BEFORE YOU DIG 811 PLOTTED: 0610812017 BY: SARAH THATCHER PLACE 24X FIBER E/W 1-1.25 ID. IN EXISTING 4" CBO 782' -R/W- -R/W- - EDP .... C/L -R/W- - EDP - - - EDP - STA. 21+07 -R/W- -R/W- -]RW- PARKING R W- — PARKING 540 GARDEN AVE N RENTON, WA 98057 DRAFTED BY: KILLION COMM MPOP STA. 22+00 540 GARDEN AVE N ATC LEASING FIELD ENGINEER: PATRICK MARKS (503)-347-1137 TOWN: RANGE: SECT: 23N I 5E 1 8 JOB: N. 259330 GEO CODE: WC CLLI: RNTNWA01 SH 3 OF 3