HomeMy WebLinkAboutP_CAD_N.284237_171006_v1CONSTRUCTION NOTES:
1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.
2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION
AND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THE
ACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BE
SOMEWHAT DIFFERENT FROM THAT SHOWN, THE CONTRACTOR IS REQUIRED TO
VERIFY PRIOR TO EXCAVATION.
3. FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT
PRIOR TO ENTRY, PLACE WARNING DEVICES AND WORK AREA PROTECTION AS
REQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE,
AND LOCAL REGULATIONS.
4. ALL EXCAVATION. TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OF
FEDERAL REGULATIONS (CFR) 1926.650 SUBPART P.
a .PROVIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF EXCAVATION FOR
TECHNICIAN INGRESS/EGRESS.
b .EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT
OR TRENCH.
c BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALL
BARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT
VISIBILTY.
d .FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR
WALL STABILITY.
5. TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND
CLODS. THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS
AND A MINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE
FROM THESE STANDARDS WILL BE SPECIFIED ON THE PLANS).
6. ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR
DAMAGED AS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL
CONDITION OR BETTER.
7. NORMAL/GUIDED—BORING METHOD RECOMMENDED WHEN BORING.
8. ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.
9. BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S).
10. AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING WORK PER STATE
AND LOCAL REGULATIONS.
11. ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO BE WITH
APPROVED WARNING DEVICES AND PLACED PER STATE DEPARTMENT OF
TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT
STANDARDS AND SPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN
SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO
BEGINNING WORK, PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN
ADVANCE OF CONSTRUCTION ACTIVITIES.
12. EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINED
AT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS AND
WALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENT
OF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENT
STANDARDS ANS SPECIFICATIONS.
13. THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIOR TO
CONSTRUCTION.
ESTIMATED TOTALS
TOTAL
EXISTING CONDUIT USED:
0
LF
TOTAL
NEW BORE:
0
LF
TOTAL
NEW DIRT TRENCH
25
LF
TOTAL
NEW S/W TRENCH
0
LF
TOTAL
NEW ASPHALT TRENCH
0
s�y
TOTAL
NEW AERIAL
0
LF
SIDEWALK (PCC) R&R: 0 SF
ASPHALT (AC) R&R 0 SF
CDFS: YESN0:
SCOPE OF WORK
PLACE ONE NEW COOL PED AND ASSOCIATED CONDUITS
Century Link
92
G�
4
S PUgei Dr
m
4uge qr 5 S El
A�9C+r Dr
4�
rr
a
A
cn
m
�o
�
s�y
e
CUSTOMER NAME: SERVICE ORDER:
LCON: XXX
LCON#: XXX
01
CALL TWO WORKING DAYS
BEFORE YOU DIG
81 1
4v
a
uni con
Automotive Seruieea
Q
P� RemeoCerper
L
'n,
a
�o
s�y
WORK AREA
VICINITY MAP
Field Engineer: Jim Christian CTL En ineer: Leslie Ferguson I UvvN-
Phone No:(253)720-9502 Phone 206)733-8862 23N
NOTICE — NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
21,
1500 BEACON WAY SE JOB: N.152423
RENTON, WA 98058 G E O CODE: W26226
Drafted by: Mountain LTD/SC WC CLLI: RNTNWA01 SH 1 OF 3
AERIAL LEGEND
EXISTING
EQUIPMENT LEGEND
ANC
ANCHOR
- CENTERLINE
TELEPHONE BULLET PEDESTAL ELECTRIC PEDESTAL/CABINET
GAS METER o IRRIGATION METER
CA ARM
CABLE ARM
—aw- -aw- -aw- -aw RIGHT OF WAY
TELEPHONE REPEATER
ELECTRIC TRANSFORMER
GAS VALVE 0 IRRIGATION VALVE
CATV
CABLE TV
—P•--P•--P, PROPERTY LINE
TELEPHONE PEDESTAL
Q ELECTRIC METER
TRAFFIC SIGNAL VAULT/HANDHOLE >--< CULVERT
DG
DOWN GUY
— — — — EASEMENT
TELEPHONE VAULT/HANDHOLE O ELECTRIC VAULT/HANDHOLE
TRAFFIC SIGNAL POLE C C/L MONUMENT
DGA
DOUBLE GUARD ARM
0. 0. em 0— EDGE OF PAVEMENT
TELEPHONE CABINET
O ELECTRIC MANHOLE o
WATER METER XO POLE ITEM NO.
FGA
FIBER GLASS ARM
— — — - CURB & GUTTER
F(D-1 TELEPHONE MANHOLE
8 ELECTRIC J-BOX S
WATER VALVE
F/S
FIELD SIDE
RAILROAD
® TELEPHONE COOL PED d STREETLIGHT b
FIRE HYDRANT
GA
GUARD ARM
FENCE
E TELEPHONE SAI
® CATV BULLET PEDESTAL ©
WATER MANHOLE
HOA
HEIGHT OF ATTACHMENT
TELCO
USAM TELEPHONE USAM
0 CATV PED
STORM DRAIN CATCH BASIN
M/R
MAKE READY
ELECTRIC
O TELEPHONE OWNED POLE N CATV VAULT/HANDHOLE
STORM DRAIN INLET
OHG
OVERHEAD GUY
— — ^T —°^rv- CATV
® JOINT USE POLE
D SEWER MANHOLE
STORM DRAIN MANHOLE
R/S
ROAD SIDE
GAS
SLAN
LIGHT OR POWER COMPANY INVENTORY NUMBER
— TRAFFIC SIGNAL
SWA
SIDEWALK ANCHOR AND GUY
w w w WATER
T
TELEPHONE
SEWER
TERM
TERMINAL
STORM DRAIN
TRANS
TRANSFORMER
° a^° a^° as IRRIGATION
TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP
SECONDARY POWER CABLES AND/OR TOP OF RISER
CABLES SO PROPOSED CABLE CAN BE ATTACHED
WITHOUT VIOLATING THE 40" RULE
CABLE ARM ATTACHMENT LOCATION:
TF
TOP FIELD SIDE
PROPOSED EQUIPMENT LEGEND
TS
TOP STREET SIDE
TIP
TOP INSIDE POSITION
PARKWAY TRENCH
❑ 2'x2' RECEIVING PIT
ANCHOR & DOWN GUY
ns
TMP
TOP INSIDE STREET SIDE
TOP MIDDLE POSITION
BORE
Ll4'x4' BORE PIT
iXi SAI XXX'
DOWN GUY
ASPHALT TRENCH FOOTAGE
TOP
TOP OUTSIDE POSITION
ASPHALT TRENCH
® COOL PEDESTAL XXX'
DIRT OR S/W TRENCH FOOTAGE
TOS
TOP OUTSIDE STREET SIDE
I[ ELECTRIC PEDESTAL XXX'
BORE FOOTAGE
BF
BOTTOM FIELD SIDE
AERIAL BUILD
T1 TELCO HANDHOLE XXX'
AERIAL FOOTAGE
BS
BOTTOM STREET SIDE
,�
AERIAL BUILD
SLACK SPAN
® TELCO PEDESTAL
BIP
BOTTOM INSIDE POSITION
L TELCO CABINET
AERIAL STRAND
BIS
BOTTOM INSIDE STREET SIDE
TO TELCO MANHOLE
BMP
BOTTOM MIDDLE POSITION
BOP
BOTTOM OUTSIDE POSITION
BOS
BOTTOM OUTSIDE STREET SIDE
Field Enggineer: Jim Christian CTL En ineer: Leslie Ferguson TOWN: �RNGE: SECT:
Phone No:(253)720-9502 Phone 206)733-8862 23N 5E 21
1 �
enurLiV/A�� nk
CALL TWO WORKING DAYS
BEFORE YOU DIG
g
NOTICE - NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
1500 BEACON WAY SE
RENTON, WA 98058
JOB: N.152423
GEO CODE: W26226
WC CLLI: RNTNWA01 SH 2 OF 3
Drafted by: Mountain LTD/SC
Century Link
i
SPEED /
LIMIT
25
DRIVE E SE
W
U)
I �
J
_J
I
J
LU
}�
N O
of
!/r
(<r(rr•-) hJl r�r � � p�1
GET
0
in
�317297-166583
A0569061
02
NO W
NO WORK
POWER PED
PL CE 6'-1-4"
PVC FOR
FIBER l
y EXISTING CTL HH
J
w
3'
PLACE 5'-1-4" PVC
FOR FIBER
LO
TRAFFlC SPEED
BARRIER LIMIT
�c 25
0
EO`P
0
Z
W
W
0
eeqcoN
W,� Y SE
-PLACE 14'-1-2" PVC
FOR POWER
E� SAI
PLACE 11'-1-4" PVC
FOR COPPER
NOTE:
ACTUAL LOCATIONS OF THE NEW CONDUITS
AND NEW COOL PED MAY VARY ONCE THE
EXISTING UNDERGROUND STRUCTURES ARE LOCATED
Field Engineer: Jim Christian CTL En ineer: Leslie Ferguson TOWN: RNGE: SECT.
Phone No:(253)720-9502 Phone 206)733-8862 23N 5E 21
NOTICE — NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENT
CALL TWO WORKING DAYS
BEFORE YOU DIG 1500 BEACON WAY SE JOB: N.152423
811 RENTON, WA 98058 G E O CODE: W26226
Drafted by: Mountain LTD/SC WC CLLI: RNTNWA01 SH 30F,3