Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutP_CAD_N.248374_171011_v1CONSTRUCTION NOTES
x
1.
CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO
DESIGNED SERVICES:
_
TRENCHING OR DIGGING.
-
2.
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
CenturyLink-
UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS
❑
-
WERE OBTAINED BY FIELD INSPECTION AND A SEARCH OF
CITY:
®
THE AVAILABLE CITY OR COUNTY REC❑RDS, SINCE THE
COUNTY:
ACTUAL LOCATI❑N AND NATURE OF THE UNDERGROUND
n
FACILITIES MAY BE SOMEWHAT DIFFERENT FROM THAT
❑
SHOWN, THE CONTRACTOR IS REQUIRED TO VERIFY PRIOR TO
EXCAVATION.
c
3.
FOR UNDERGROUND ACTIVITYi TEST AND VENTILATE
MANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACE WARNING
DEVICES AND WORK AREA PROTECTION AS REQUIRED, AND
USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL,
STATE, AND LOCAL REGULATIONS.
4.
ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE
TO THE CODE OF FEDERAL REGULATIONS (CFR) 1926:650
P.
a.
SUBPART
PR❑VIDE ALL PITS WITH 1'x1' SLOPE AT ONE END OF
EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.
;
b.
EXCAVATED SP❑ILS ARE TO BE NO LESS THAN 24' EDGE OF
'=
PIT OR TRENCH.
c:
BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC
SAFETY. ALL BARRICADES MUST BE EQUIPPED WITH FLASHING
LIGHTS FOR NIGHT VISIBILITY.
onIKEA
d,
FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE
rtsCerner(9
SHORING FOR WALL STABILITY.
5.
TRENCH COVER IS TO BE 36' MINIMUM AND FREE OF ROCKS,
DEBRIS, AND CLODS. THE TRENCH IS TO BE A MINIMUM OF
36' COVER IN DEVELOPED AREAS AND A MINIMUM OF 48' OF
O
COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESE
STANDARDS WILL BE SPECIFIED ON THE PLANS.)
6.
ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED,
DISTURBED, OR DAMAGED AS A RESULT OF CONSTRUCTION
SHALL BE RESTORED TA ORIGINAL CONDITION OR BETTER.
a
7,
NORMAL/GUIDED—B❑RING METHOD RECOMMENDED WHEN B❑RING.
N
8.
ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.
v
9,
BOND BURIED/AERIAL FACILITIES AS REQUIRED BY
2
JURISDICTI❑NAL AGENCY(S),
10,
AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINNING
WORK PER STATE AND LOCAL REGULATIONS.
11.
ALL WORK AREA PROTECTIONS FOR TRAFFIC CONTROL IS TO
BE WITH APPROVED WARNING DEVICES AND PLACED PER
STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC
WORKS ENGINEERING DEPARTMENT STANDARDS AND
SPECIFICATIONS, IF REQUIRED, A TRAFFIC CONTROL PLAN
SHALL BE SUBMITTED TO THE REQUESTING PERMITTING
AGENCY. PRIOR TO BEGINNING WORK, PERMITTING AGENCIES
MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTION
ACTIVITIES,
12.
EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS
SHALL BE MAINTAINED AT ALL TIMES. AS NECESSARY,
TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS
t
SHALL BE PROVIDED AND MAINTAINED PER STATE
DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKS
E
ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS,
R
13.
THE FOLLOWING F❑OTAGES ARE ESTIMATES. FOOTAGES TO BE
VERIFIED PRIOR TO CONSTRUCTION.
a
S 2nd St
Heaven Sent
Fried Chicken
SCOPE OF WORK: THIS JOB WILL PLACE NEW EQUIPMENT AT 150 LOGAN AVE S, RENTON
FIBER: 9/19/17 THIS UPDATE WILL PROPOSES MATERIALS BELOW:
• PLACE APPROX. 100 FEET 11NCH INNERDUCT AND FIBER.
• TRENCH 1-41NCH 4 FEET
• TRENCH 1-21NCH 9 FEET
• PLACE NEW HAND HOLE
• REMOVE AND REPLACE APPROX. 14'X 6' SIDEWALK PANEL
• TIE INTO CUSTOMER NEW 21NCH CBO AT PROPERTY LINE.
PLANNERS NOTES ARE PROVIDED FOR REFERANCE BELOW:
POF MH 194 LRE18, 5-6 / PLACE NEW 24CT FROM MH 194 THRU MH 193, THRU HH 9 TO CUST MPOP
VICINITY MAP
WORK LOCATION
150 LOGAN AVE S
:h
r� a
hase ank c
O Park & Ride
n
cn
Remo n Tc Acrd
o B
QRenion Pavilion
15
S '3rd 5t
3
® QD
a
I
x
All Underground Utility Locations Shown Hereon Are
DESIGNED SERVICES:
_
-
10
r
CenturyLink-
ROW REQUIRED:
❑
-
CITY:
®
❑
COUNTY:
❑
n
v
❑
c
WORK LOCATION
150 LOGAN AVE S
:h
r� a
hase ank c
O Park & Ride
n
cn
Remo n Tc Acrd
o B
QRenion Pavilion
15
S '3rd 5t
3
® QD
a
I
PERMITS
All Underground Utility Locations Shown Hereon Are
DESIGNED SERVICES:
Approximate.Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
c
v�
CenturyLink-
S2nd S1
U.S, Bank Branch
Jones Park
+ S 2nd St
N
PERMITS
YES/NO
DESIGNED SERVICES:
❑
c
v�
ROW REQUIRED:
❑
N
PERMITS
YES/NO
DESIGNED SERVICES:
❑
HELD ORDERS:
❑
ROW REQUIRED:
❑
CITY:
®
❑
COUNTY:
❑
STATE:
❑
RAILROAD: ❑
LOOP QUAL.: ❑
,. PREMIS FORM: ❑
v
CONFORMANCE TEST: ® ❑
i SEE NDS
ERFS DATE:
TRENCH OPEN DATE:
1 aerlirierPublD APPROVED MNEMONICS:
1 ASSOCIATED PROJECTS:
Hot Yoga Renton
8-BIt ArLade
0
ro s 3rd St s
The Local 907
© 4 Naan -d- Curry m v
Bank of America �E a I I a,IS
Finarcial Center = ro
CUSTOMER:9/19/17 CUSTOMER WILL WANTTO PROVIDE THE FOLLOWING:
• 1 - 241NCH X 241NCH PULL BOX
• TRENCH APPROX. 12 FEET OF NEW 1-21NCH CONDUIT
• FROM NEW PULL BOX PLACE APPROX. 25 FEET OF NEW 21NCH UP WALL TO EXISTING WEATHER
HEAD, THIS WEATHER HEAD TO BE REMOVED AND REPLACED WITH A 90 DEG 21NCH BEND THAT
WILL CONNECT NEW 21NCH WITH EXISTING 21NCH GOING INTO THE BLDG'S MPOP.
r CALL TWO WORKING DAYS
BEFORE YOU DIG
811
150 LOGAN AVE S
RENTON, WA 98057
LCON NAME AND NUMBER:
CAROLYNN SNOW 253-3055032
FIBER ENGINEER:
MIKE GILLIAM
CUSTOMER NAME:
JPMORGAN CHASE
ADDRESS:
150 LOGAN AVE S
RENTON, WA 98057
FIELD ENGINEER: CORY COATE
(503)-961-5023
TOWN: RANGE: SECT:
23N I 5E 1 18
JOB: N.248374
CEO CODE:
WC CLLI: RNTNWA01
PLOTTED: 09/20/2017 BY: SARAH THATCHER DRAFTED BY: KILLION COMM. SH 1 OF 3
AERIAL LEGEND
ANC ANCHOR
CA ARM CABLE ARM
CATV CABLE TV
DG DOWN GUY
DGA DOUBLE GUARD ARM
FGA FIBER GLASS ARM
F/S FIELD SIDE
GA GUARD ARM
HOA HEIGHT OF ATTACHMENT
M/R MAKE READY
❑HG OVERHEAD GUY
R/S ROAD SIDE
SLAN LIGHT OR POWER COMPANY INVENTORY NUMBER
SWA SIDEWALK ANCHOR AND GUY
T TELEPHONE
TERM TERMINAL
TRANS TRANSFORMER
TAPE & SHAPE REQUEST FOR POWER COMPANY TO CLEAN UP
SECONDARY POWER CABLES AND/OR TOP OF RISER
CABLES S❑ PROPOSED CABLE CAN BE ATTACHED
WITHOUT VIOLATING THE 40' RULE,
CABLE ARM E T LOCATION
TF TOP FIELD SIDE
TS TOP STREET SIDE
TIP TOP INSIDE POSITION
TIS TOP INSIDE STREET SIDE
TMP TOP MIDDLE POSITION
TOP TOP OUTSIDE POSITION
T❑S TOP OUTSIDE STREET SIDE
BF BOTTOM FIELD SIDE
BS BOTTOM STREET SIDE
BIP BOTTOM INSIDE POSITION
BIS BOTTOM INSIDE STREET SIDE
BMP BOTTOM MIDDLE POSITI❑N
BOP BOTTOM OUTSIDE POSITION
BOS BOTTOM OUTSIDE STREET SIDE
CenturyLink
I
EXISTING EQUIPMENT LEGEND
EDGE OF PAVEMENT ® TELEPHONE BULLET PEDESTAL 0 ELECTRIC PEDESTAL/ CABINET
C/L
CENTERLINE
®
TELEPHONE
REPEATER
PVR
ELECTRIC TRANSFORMER
-R/W- -R/W-
RIGHT OF WAY
®
TELEPHONE
PEDESTAL
Ej�
ELECTRIC METER
P/L
PROPERTY LINE
HN
TELEPHONE
VAULT/HANDHOLE
F -E--)
ELECTRIC VAULT/HANDHOLE
— — — — — — — — —
EASEMENT
TELEPHONE
CABINET
(r
ELECTRIC MANHOLE
— =
CURB & GUTTER
®
TELEPHONE
MANHOLE
8
ELECTRIC J -BOX
the H li -E FH+l111 1 1 j H--�H-FF H-11
RAILROAD
®
TELEPHONE
COOL PED
®
SEWER MANHOLE
FENCE
IXi
TELEPHONE
SAI
®
STORM DRAIN CATCH BASIN
— - - -TEL - - - -TEL- - - -TEL--
TELCO
ka
TELEPHONE
USAM
® STORM DRAIN INLET
ELEC
ELECTRIC
O
TELEPHONE
OWNED POLE
®
SEWER DRAIN MANHOLE
CATV
CATV
®
J❑INT USE
POLE
OO
C/L MONUMENT
GAS
(0
CATV BULLET
PEDESTAL
®
POLE ITEM NO.
-- --- -- T AFFIC
TRAFFIC SIGNAL
ry
CATV PED
- WATER WATER
WATER
ry
CATV VAULT/HANDHOLE
SEWER SEWER
SEWER
TRANSFORMER POLE
— STORM STORM
STORM
IRRIG IRRIG
IRRIGATION
PROPOSED EQUIPMENT LEGEND
- - - - - - PARKWAY TRENCH
All Underground Utility Locations Shown Hereon Are
Approximate.Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
ASPHALT TRENCH
AERIAL BUILD
AERIAL BUILD
SLACK SPAN
AERIAL STRAND
CALL TWO WORKING DAYS
BEFORE YOU DIG
811
PLOTTED: 09/20/2017 BY: SARAH THATCHER
® 2'x2' RECEIVING PIT
® 4'x4' RECEIVING PIT
1X1 SAI
®
COOL PEDESTAL
ELECTRIC PEDESTAL
HH TELCO HANDH❑LE
® TELCO PEDESTAL
0 TELCO CABINET
® TELCO MANHOLE
GAS METER
GAS VALVE
WATER METER
® WATER VALVE
-& FIRE HYDRANT
© WATER MANHOLE
0 IRRIGATI❑N METER
0 IRRIGATION VALVE
>—( CULVERT
rs TRAFFIC SIGNAL VAULT/HANDHOLE
C) TRAFFIC SIGNAL POLE
f� STREETLIGHT
> ANCHOR & DOWN GUY
�-
DOWN GUY
xxx ASPHALT TRENCH FOOTAGE
xxx' DIRT OR S/W TRENCH FOOTAGE
xxx' BORE FOOTAGE
xxx' AERIAL FOOTAGE
150 LOGAN AVE S
RENTON, WA 98057
DRAFTED BY: KILLION COMM.
JOB: N.248374
GEO CODE;
WC CLLI: RNTNWA01
SH 2 OF 3
-PL 11 18'TOTAL FIBER
-PL 1028'1-1/4" I.D.
-PL 40' STRAND
- -R/W-
EDMH1941D—
OP 1
80'
EOP
EDP
-R/W-
0
0
+
0
I
3
a
6'
2'
tl
d �
STA +94
STA. +93
14'
a IT
o
W �
I d
C3
I
u�
rn
ST
I a
R/W- -R/W- w
EDP -
CTL TO REMOVE AND REPLACE 14'X6' SIDEWALK
PANEL LOCATE EXISTING 4"CONDUIT FROM HH9
TO BREAK AND REDIRECT TO A NEW SMALL
kf
HANDHOLE (PULLBOXIHANDHOLE)
"3 a GRASS> GRASS
d a
� w �
I
114' CTL DUCT
I
Lo
TY
co co
- - - -- FOP
-R/W-
+(o
—C/L—
-R/W- -R/W- -
v
N
W
0
EDP ~
N
U)CO
HH9
I
a
I
—R/W
- EDP
COP -
- - - -- FOP
-R/W-
-R/W-
-R/W- -R/W- -
v
N
W
0
643' CTL DUCT
TOWN:
F
0
SECT:
T
a
w
�
�
All Underground Utility Locations Shown Hereon Are
r+� Approximate.Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
EDP —
—C/L-
EXISTING
50'2" CBO
MPOP
CUSTOMER TO REMOVE
WEATHER HEAD AND PLACE
A 900 BEND WITH A NEW
PULLBOX
CHASE BANK j
150 LOGAN AVE S
CUSTOMER TO TRENCH APPROX 12' FROM
PROPERTY LINE TO OUTSIDE. BLDG WALL.
WHERE CUSTOMER WILL PLACE NEW
PULL BOX 24"X24"
- R/W-
EDP
i
EDP
i c�7 4
—C/L— �C/L— --C/L—+--
if)—
.S' �NIJ ,ST
ECP EDP FOP
-R/W- -R/W— -R/W- -R/W- -R/W-
271' CTL DUCT
N
Q �
W W
I
J
V
a
13
W I w
o n
W w
} 5'
MH193 I 4'
Y _ EDP —
I
O M u7
c*7
—C/L—
cD cD co W
(nCDa)U)
COP
W 41
FIELD ENGINEER: CORY COATE
IL
(503)-961-5023
w
W
T
TOWN:
F
RANGE:
SECT:
❑
a
w
�
�
All Underground Utility Locations Shown Hereon Are
r+� Approximate.Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
I
CALL TWO WORKING DAYS
BEFORE YOU DIG
o n
W w
} 5'
MH193 I 4'
Y _ EDP —
I
O M u7
c*7
—C/L—
cD cD co W
(nCDa)U)
COP
W 41
FIELD ENGINEER: CORY COATE
(503)-961-5023
TOWN:
F
RANGE:
SECT:
23N
5E
18
All Underground Utility Locations Shown Hereon Are
r+� Approximate.Construction Contractor Is Responsible
For The Location Of Municipal And Private Utilities
CALL TWO WORKING DAYS
BEFORE YOU DIG
S
JOB: N.248374
150 LOGAN AVE
7CenturyLink7-
811
RENTON, WA 98057
GEO CODE:
WC CLLI: RNTNWA01
PLOTTED: 0 912 012 01 7 BY: SARAH THATCHER
DRAFTED BY: KILLION COMM.
sH 3 OF 3