Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutMFP17005860DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17005860
IVR Number: 17005860
Permit Informa!on
Permit Name:Century Link Permits
Address/Loca!on:12/08/2017Applica!on Date:1253810260Parcel Number:1001 SW 34TH ST
Permit Type :12/20/2017Issue Date:Franchise
Permit Work Class:12/20/2018Expira!on Date :Minor U$lity
Job Number:N.317960Franchise Type :Telephone
Descrip!on:Century Link to access MH265, MH387, HH UN 106 and HH454. Restora$on per City of Renton Standards.
Contacts
Name Address PhoneTypeBilling
C/O QWEST CORP 1801 CALIFORNIA ST #4600
Denver, CO 80202
Applicant
Kim Parker
QWest Corpora$on
931 14th St, SUITE 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Heather Binkly
Dycom Industries dba North Sky Communica$ons LLC
11770 Us Hwy 1, SUITE 101
Palm Beach Gardens, FL 33408
B: (360) 254-6920
O: (360) 450-3287
Contractor
Business License Number: BL.036846Construc!on Contractor : NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
X
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 | Published: 3/30/2017
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour.
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Description of Work:
Please check all that apply:
☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street
☐ Open Trench ☐ Bore # of feet:
Contractor Name: Phone:
State Contractors License #: City of Renton Business License #:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
Qwest Corp. d/b/a CTL QC
N.317960
Charlene Greene
253.854.4074
Charlene.Greene@CenturyLink.com
1001 SW 34th St, Renton N.317960
CenturyLink to access MH265, MH387, HH UN-106 and HH454.
No disturbance of surface.
North Sky Communications, LLC 360.254.6920 ext 3641
NORTHSC857Q4 BL.028638
4
Restoration Per City of Renton Standards
Scott Warlick 12/12/2017
MFP17005860
Justin Johnson 12-20-2017
CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: PERMIT#
CONSTRUCTION COMPANY: PHONE#:
CONTACT NAME: PHONE#:
ADDRESS: CELL#:
E-MAIL ADDRESS: FAX#:
PROJECT LOCATION: N/E/S/W OF:
WORK TIME: APPROVED BY:
WORK DATE: APPROVAL DATE:
OFFICE COPY T-
CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER
DEV. SERVICE, PLAN REVIEW B. BANNWARTH
POLICE CHARLES KARLEWICZ
FIRE FIRE MARSHALL FS #13
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney’s fees incurred in defending against same, arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel.
• By my signature herein, I acknowledge all the above requirements.
PRINT NAME: DATE:
SIGNATURE:
N.317960
North Sky Communications, LLC 360.254.6920
Angee Ellis ext. 3641
22517 88th Ave S, Kent, WA 98031
AEllis@NorthskyCom.com
1001 SW 34th St, Renton
Reset FormPrint Form
Charlene Greene 12/08/2017
Charlene Greene
MFP17005860
8:00 am to 3:00 pm
Monday through Friday
Justin Johnson
12-20-2017
SKETCH
I
-- NORTH --
I
NOTES:
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three
working days prior to work.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected
by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded.
• Total road closure lasting more than 24 hours is subject to the approval by the City Council.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop
(3555 NE 2nd Street).
TRAFFIC CONTROL PLAN
JOB # N.295278.C.07
PERMIT #
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
80TH AVE S @ S 180TH ST
MH 265
Date:10/13/2017 Author:Sharon Martos, Traffic Control Supervisor Project:N.295278.C.07
CERT:TCS # 010745 CENTURYLINK:This Plan is the Property of CenturyLink LOC:WC 5411
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF KENT
requirements.
2. Channelizing devices are 28" traffic cones with retroreflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
80TH AVE S
OAKESDALE AVE SWS 180TH STSW 43RD STROADWORKAHEADW20-1ROAD
WORK
AHEAD
W20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2MH 265
WORK AREA
10 X 120
1110N
Comments:
ACCESS MH 265 LOCATED ON THE WEST SIDE OF
80TH AVE S, SOUTH OF S 180TH ST.
THIS IS A RIGHT LANE CLOSURE.
Property of CenturyLink
Project # N.295278.C.07
Sharon Martos
Traffic Control Supervisor
TCS # 010745
Approved 10/13/2017
Phone 253-737-5198
sharon.martos@gmail.com
Sharon Martos ROADWORKAHEADW20-1Legend
Work Area
Cone
truck
Arrowboard (Chevron)
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF KENT TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com
www.invarion.com
--------------
N.317960
MFP17005860
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' max
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
SW 41ST ST @ OAKESDALE AVE SW
MH 387
MH 387ROADWORKAHEADW20-1ROAD
WORK
AHEADOAKESDALE AVE SWSW 41ST ST
Comments:
THIS IS TO ACCESS THE MH 367 LOCATED
IN THE NORTHBOUND LANE OF OAKESDALE RD SW.
THIS WILL BE A RIGHT LANE CLOSURE.
TRAFFIC WILL SHIFT INTO THE LEFT LANE.
PEDESTRIANS ARE NOT IMPACTED.
Legend
Work Area
truck
CONES
Arrowboard (Chevron)
TRAFFIC CONTROL PLAN
JOB # N.295278.C.07
PERMIT #ROADWORKAHEADW20-1RIGHT LANE
CLOSED
AHEAD
W20-5
W4-2
SPEED
LIMIT35
Designed For: CENTURYLINK
Project # N.295278.C.07
Kathy Hubbard
Traffic Control Supervisor
TCS # 008909
Approved 10/13/2017
Phone 253-737-5198
tcpnd@comcast.net
_______________________
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF KENT TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
KATHY HUBBARD, TCS# 008909, tcpnd@comcast.net
Date:10/13/2017 Author:Kathy Hubbard, Traffic Control Supervisor Project:N.295278.C.07
CERT:TCS # 008909 Designed for CenturyLink:By Kathy Hubbard (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF KENT
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48" x 48" B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum of 11' for lane width.
6. Work hours will be ____am to ____pm.
N
WORK AREA
10' X 275'
www.invarion.com
-----------------N.317960
MFP17005860
OAKESDALE AVE SWSW 41ST ST
TRAFFIC CONTROL PLAN
JOB # N.317960
PERMIT #
Designed for: CENTURYLINK
Project # N.317960
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 12/07/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:12/07/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.317960
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
Arrowboard (Chevron)
SPOTTER
HH UN-106
WORK AREA
11' X 385'ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2ROADWORKAHEADW20-1ROAD
WORK
AHEAD
W20-1
350'
350'
350'
350'
350'
Comments:
THIS IS TO ACCESS HH UN-106 LOCATED IN THE WEST SIDE OF
OAKESDALE AVE SW NORTH OF SW 41ST ST.
THIS IS A RIGHT LANE CLOSURE OF SOUTHBOUND OAKESDALE
AVE SW NORTH OF RAILROAD TRACKS.
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.SPEED
LIMIT35
N
OAKESDALE AVE SW @ SW 41ST ST
HH UN-106 ACCESS
www.invarion.com
MFP17005860
OAKESDALE AVE SWSW 34TH ST
TRAFFIC CONTROL PLAN
JOB # N.317960
PERMIT #
Designed for: CENTURYLINK
Project # N.317960
Darlene Durr
Traffic Control Supervisor
TCS # 008900
Approved 12/07/17
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________
Date:12/07/17 Author:Darlene Durr, Traffic Control Supervisor Project:N.317960
CERT:TCS # 008900 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER)LOC:5357
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON
requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.
3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be ____am to ____pm.
Comments:
MERGING TAPER LENGTH
TAPER ("L") LANE WIDTH
L MPH 10' 11' 12'
-----------------------------------
SHIFTING 20 70 75 80
TAPER 25 105 115 165
1/2 L 30 150 165 180
35 205 225 245
SHOULDER 40 270 295 320
TAPER 45 450 495 540
1/3 L
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #008900, darlene.durr@hotmail.com
Comments:
CHANNELIZATION SPACING
MPH TAPER TANGENT
35 / 45 30' 60'
25 / 30 20' 40'
ONE LANE TWO WAY
TAPER 50' TO 100' MAX
Comments:
SIGN SPACING
MPH "X"
45+ 500'
35 350'
30 200'
25 100'
150' Seattle
200' Sea Tac
Legend
WORK TRUCK
WORK AREA
CONES
Arrowboard (Chevron)
SPOTTER
WORK AREA
11' X 275'
HH 454
ROAD
WORK
AHEAD
W20-1 ROADWORKAHEADW20-1ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2350'
350'
350'
350'
350'
Comments:
THIS IS TO ACCESS HH 454 LOCATED IN THE WEST SIDE OF OAKESDALE
AVE SW SOUTH OF SW 34TH ST.
THIS IS A RIGHT LANE CLOSURE OF SOUTHBOUND OAKESDALE AVE SW
SOUTH OF SW 34TH ST.
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.
OAKESDALE AVE SW @ SW 34TH ST
HH 454 ACCESS
SPEED
LIMIT35
N
www.invarion.com
MFP17005860
© 2017 HERE © 2017 Microsoft Corporation MHHHHH HHHH
HHHH
MHEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/2017CONSTRUCTION NOTES:1.CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2.THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES ORSTRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTIONAND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THEACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BESOMEWHAT DIFFERENT FROM THAT SHOWN. THE CONTRACTOR IS REQUIRED TOVERIFY PRIOR TO EXCAVATION.3.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULTPRIOR TO ENTRY. PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE,AND LOCAL REGULATIONS.4.ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OFFEDERAL REGULATIONS (CFR) 1926.650 SUBPART P.a. PROVIDE ALL PITS WITH 1'X1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALLBARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY.d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY5.TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS.THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS AND AMINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESESTANDARDS WILL BE SPECIFIED ON THE PLANS).6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGESAS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITIONOR BETTER.7.NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE ANDLOCAL REGULATIONS.11.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVEDWARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATIONAND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS ANDSPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK,PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OFCONSTRUCTION ACTIVITIES.12.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINEDAT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS ANDWALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENTOF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENTSTANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIORTO CONSTRUCTIONS.PERMITSYES /NODESIGNED SERVICES:HELD ORDERS:ROW REQUIRED:CITY:COUNTY:STATE:RAILROAD:LOOP QUAL.:PREMIS FORM:ADDITIONAL PERMIT INFO:CONFORMANCE TEST:SEE NDSERFS DATETRENCH OPEN DATE:----APPROVED MNEMONICS:ASSOCIATED PROJECTS:LCON NAME:MIKE PAYNELCON NUMBER:(425) 531-2836FIBER ENGINEER:VICTOR NOVELOFIBER ENGINEER CONTACT:(253) 372-5363CUSTOMER NAME:CINTASADDRESS:1001 SW 34TH ST,RENTON, WA 98057EQUIPMENT: (1) CIENA 3916, (1) 24 PORT FDP, (+/- 1361') 72CT MICRO-FIBER, (+/- 1361') 7 WAY FUTUREPATH, (+/- 261') 24CT TRANSITION FIBER, (+/- 261') 1.25" IDNARRATIVE: AT POF MH 265, PUSH COUNT LKO22, 573-574 FROM EXISTING 144CT FIBER [CYQ1] TO EXISTING 48CT CABLE [A0RN9] THAT FLOWS TO MH 387. AT MH 387, PUSH COUNT ONTO 72CT STUB [A31MK], PLACED BY JOB N.295278, THEN PUSH COUNT ONTOEXISTING 24CT FIBER [BD09] WHICH FLOWS THOUGH HH UN TO HH UN-106. AT HH-106, JET NEW FP WITH NEW 72CT MICRO-FIBER THOUGH EXISTING COPPER/FIBER OCCUPIED CONDUIT TO HH 454. AT HH-106, SPLICE COUNT ONTO NEW 72CT MICRO-FIBERCOUNT FLOWS TO HH 454. AT HH 454, PULL NEW 1.25" ID WITH NEW 24CT TRANSITION FIBER TO MPOP. AT HH 454 SPLICE COUNT FROM NEW 72 CT MF TO NEW 24CT TRANSITION FIBER. COUNT FLOWS TO MPOP. AT MPOP PLACE A NEW 24 PORT FDP AND A NEWCIENA 3916 ON EXISTING NORTH WALL CUSTOMER BACKBOARD. SPLICE COUNT TO FDP.CUSTOMER REQUIREMENTS: NONEVICINITY MAP1NTSWHOLESALE - CDFSCUSTOMER1001 SW 34TH STPOFMH 265OAKESDALE AVE SW WORK AREASW 43RD ST / S180TH STSW 34TH STMFP17005860
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/20172C/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEANTSTELEPHONE BULLET PEDESTALTELEPHONE REPEATERTELEPHONE PEDESTALTELEPHONE VAULT/HANDHOLETELEPHONE CABINETTELEPHONE MANHOLETELEPHONE COOL PEDTELEPHONE SAITELEPHONE USAMTELEPHONE OWNED POLEJOINT USE POLEACCESS POINTAERIAL SPLICE CLOSUREELECTRIC PEDESTAL/CABINETELECTRIC TRANSFORMERELECTRIC METERELECTRIC VAULT/HANDHOLEELECTRIC MANHOLEELECTRIC J-BOXSTREETLIGHTCATV BULLET PEDESTALCATV PEDCATV VAULT/HANDHOLESEWER MANHOLEGAS METERGAS VALVETRAFFIC SIGNAL VAULT/HANDHOLETRAFFIC SIGNAL POLEWATER METERWATER VALVEFIRE HYDRANTWATER MANHOLESTORE DRAIN CATCH BASINSTORM DRAIN INLETSTORM DRAIN MANHOLEIRRIGATION METERIRRIGATION VALVECULVERTC/L MONUMENTPOLE ITEM NO.XXX'XXX'XXX'XXX'MHTHH
HHEXAUSAMMHTHH
HHEPWREEETVTVSVTSVWSDVCENTERLINERIGHT OF WAYPROPERTY LINEEASEMENTCURB & GUTTEREDGE OF PAVEMENTRAILROADFENCETELCOELECTRICCATVGASTRAFFIC SIGNALWATERSEWERSTORM DRAINIRRIGATIONANCHOR & DOWN GUYDOWN GUYASPHALT TRENCH FOOTAGEDIRT OR S/W TRENCH FOOTAGEBORE FOOTAGEAERIAL FOOTAGE2'x2' RECEIVING PIT4'x4' BORE PITSAICOOL PEDESTALELECTRIC PEDESTALTELCO HANDHOLETELCO PEDESTALTELCO CABINETTELCO MANHOLETRENCHBOREASPHALT TRENCHAERIAL BUILDAERIAL BUILDSLACK SPANAERIAL STRANDR/WEOPTECATVGASTSWSSDC/LP/LIRRIGMFP17005860
S 180TH ST/ SW 43RD STC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LC/LEOPEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOPEOPEO
P
EOPEOP EOPEOPEOPEOPEOPEO
P
EOP EOP
C/L C/L C/L
C/LC/LC/L R/WR/WR/WR/WR/WR/WR/WR/WR/W P/LP/LR/WR/WR/WR/WR/WR/W
R/WR/W
P/LP/LR/WR/W
R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WD/WD/WD/WD/WD/WP/L P/LParcel #: 362304908679798009100012001250Parcel #: 3623049114Parcel #: 3623049108Parcel #: 3623049112Parcel #: 3623049100Parcel #: 3623049096D/WPOFMH 265(5' from EOP)35SPEEDLIMITMH35SPEEDLIMIT78'11'11'11'11'12'6'SidewalkSidewalkSidewalkSidewalkSidewalk
Sidewalk
Sidewalk 92'5'10'12'11'11'10'104'5'11'11'12'11'11'5'
EOPEOP
EOPEOPEOPEOPEOPEOP6'0+00OAKESDALE AVE SW
TO MH 387
SEE SHEET 4Existing fiberEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201731" = 40'MFP17005860
SW 41ST STC/LC/LC/LC/LC/LC/LC/LEOP
EOPEOPEOPEOPEOPEOPEOPEOPR/W
R/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPEOPEOPEOPEOP
C/L C/L
HHHH
25SPEEDLIMITHH UN(24' from EOP)No AccessEOPEOPEOPEOPEOPEOPEOPEO
P
EOPEOP
OAKESDALE AVE SW
SidewalkSidewalk
Sidewalk
Island D/WD/WD/WParcel #: 3623049001P/LP/L R/WR/WR/WR/WR/WR/WP/L
R/W R/W
R/WR/WR/WR/WR/WR/WR/WP/LP/LP/LP/LP/L35SPEEDLIMITParcel #:3623049104Parcel #: 36230490324001Parcel #: 3623049033Parcel #: 362304UNKNParcel #: 3623049109Parcel #: 36230491121001MATCH TO SHEET 5MATCH TO SHEET 41012101078'
10'
11'
10'
12'
6'8'11'13'12'10'6'94'12+23MH 387(17' from EOP)MHTO MH 265
SEE SHEET 3
Existing fiberExisting fiber10+91
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201741" = 40'MFP17005860
EOPEOPEOPEOP
R/WR/WR/W
EOPEOPEOPEOP
C/L C/L C/L C/L C/L
HH
HHHH UN-106(24' from EOP & 70' from RR)OAKESDALE AVE SW
EOP EOP EOP EOP
EOP EOP EOP EOP
C/LC/LC/LC/L
C/LC/L C/L C/L
Sidewalk
D/WSidewalk
1012R/WR/WR/WR/WR/WR/W
P/LP/LR/W R/W R/W R/WP/LP/LP/LP/LP/LP/L1010MATCH TO SHEET 5MATCH TO SHEET 4Parcel #: 3623049001Parcel #:3623049104Parcel #: 36230490324001Parcel #: 1253810390Parcel #: 1253810305P
/
L
P
/
L
P
/
L
P
/
LP/LP/LP/LP
/
L
P
/
L
P
/
L
P
/
LP/
L
P/
L
P
/
LP/
L
P/
L
Parcel #: 1253810060P
a
r
c
e
l
#
:
1
2
5
3
8
1
U
N
K
N
P
a
r
c
e
l
#
:
1
2
5
3
8
1UN
KN Parcel #: 1253810240P
a
r
c
e
l
#
:
2
5
2
3
0
4
9
0
5
4 35SPEEDLIMIT93'5'11'23'11'11'15+63Existing fiberJet new 7 way futurepath with new 72ct MFthrough existing copper/fiber occupied conduit to HH 454 (1361').TO HH 454SEE SHEET 6
EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201751" = 40'MFP17005860
CUSTOMER:1001 SW 34TH STSW 34TH STOAKESDALE AVE SWHHHHHH 454(24' from EOP)EOP EOP EOP EOP EOP EOP EOP EOPR/W R/W R/W R/W R/W R/W R/W R/WEOPEOPEOPEOPEOPEOPEOP
EOPEOPEOPEOPEOPEOPEOPEOPR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WC/LC/LC/LC/LC/LC/L C/LC/LC/LC/LC/LC/L SidewalkSidewalk
D/W31+85MPOPNEW CIENA AND FDP TO BE PLACEDON EXISTING NORTH WALL BACKBOARDCUSTOMER WILL REMOVE OLD EQUIPMENTParcel #: 1253810260Parcel #: 1253810305Sidewalk29+24POE35SPEEDLIMITJet new 7 way futurepath with new 72ct MFthrough existing copper/fiber occupied conduit to HH 454 (1361').TO HH UN-106SEE SHEET 5 30+54Pull new 1.25" ID with new 24ct fiber through existing copper-occuiped customer CBO to MPOP (261').CONSTRUCTION TO ROD AND PROVE PATHWAY FROM HH TO MPOP.91'10'11'12'11'11'EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: KENTWAOBSECTION: 25TOWNSHIP: 23NRANGE: 4ECHC CONSULTINGRCenturyLinkRCUSTOMER INFORMATIONNAME: CINTASCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: VICTOR NOVELOPHONE: (253) 372-5363CONTRACT ENGINEERCHC ENGINEER: MIGUEL SOLANOPHONE: (619) 786-2017SCALE:JOB: N.317960DATE:SHEET: OF 6REVISION: 0RCenturyLinkRCALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 1001 SW 34TH ST12/1/201761" = 40'MFP17005860