HomeMy WebLinkAboutMFP17003422DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Franchise Permit: MFP17003422
IVR Number: 17003422
Permit Informa!on
Permit Name:Comcast Cable Communincaon Management and Comcast Cable Holdings
Address/Loca!on:07/20/2017Applica!on Date:1644510111Parcel Number:2621 PARK AVE N
Permit Type :07/21/2017Issue Date:Franchise
Permit Work Class:07/21/2018Expira!on Date :Minor Ulity
Job Number:#189366Franchise Type :Cable
Descrip!on:Open trench / bore 175' and place 2" PVC. Begin trenching 12' from CATV pedestal at SW corner of 1220's property
and bore 24" under 1220's driveway and connue trenchin g 139' to place 9" flush mount Carson Box.
Contacts
Name Address PhoneTypeBilling
Comcast Cable Communicaon Management & Comcast
Cable Holding
B: (215) 665-1700Applicant
Brian Hoback
Comcast
B: (253) 864-4663Applicant
Tom Donnelly
Comcast Business Communicaons LLC
1701 JC Blvd, 32nd Floor
Philadelphia, PA 19103
B: (215) 286-7347
C: (215) 286-7557
Contact
Akisha Brown
Prince Telecom Inc
551A Mews Dr
New Castle, DE 19720
B: (302) 482-8893
C: (302) 482-8892
Contractor
Business License Number: BL.029850Electrical Contractor : PRINCTL834BF
Construc!on Contractor : PRINCTL862PS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Laurie Dietz
Comcast - Billing
1701 John F. Kennedy Blvd.
Philadelphia, PA 19103
Specialized
Billing
X
General Condi!ons & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
This permit and plans must be posted at the job site at all times.
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Call (425) 430-7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for
ANY work in the Right of Way.
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010
) (Olympic Pipeline at 206.510.0575)(Puget Sound Energy at 425.457.5816) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
(Date)(Signature)
Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT -----~RentOil 8
Planning Division I 1055 South Grady Way, 6th Floor I Renton, WA 98057 I 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
FRANCHISE PERMIT APPLICATION
Published: 3/30/2017
TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the
Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for
trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60 .00 per hour.
Franchise Agency: Comcast of WA IV Inc
Franchise Job Number: 189366 Phone : 253-864-4663
--------------~
Contact Name : Brian Hoback Email: brian_hoback@comcast.com
--------------~
Job Site Address: 2621 Park Ave N Project Name:
Description of Work: Requesting to open trench/bore 175' in r/w and place 2" PVC. Beg in trench ing 12' from CATV
ped SW corner of 1220's property to bore 24' under 1220's driveway, and continue trenching 139' to
place a 9" flush mount Carson box. See attached .
Please check all that apply:
~ New Construction D Repair/Relocate ~ Underground D Overhead D Sidewalk D Street
~ Open Trench ~ Bore # of feet : _1_7_5_' _____ _
Contractor Name: Prince Telecom LLC Phone: 253-891-2899
State Contractors License#: EC PRINCTL834BF City of Renton Business License#: 29850 ---------------------
"I certify that I am the owner or applicant's authorized agent and do hereby agree to abide to the terms and condit ions set forth
under this permit and shall comply with the City of Renton 's Trench Restoration and Street Overlay Requirements ."
Signature ji: ~ Date _0_7_10_1_1_2_0_17 _____ _
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT. COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour.
All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date
Site Construction Inspector Date
Development Engineering Manager Date
D Approved as submitted
D Pre-Construction Meeting required
D Approved with comments or redlines
D Camera inspection of utili ties r equired
Page 1 Published: 3/30/2017
MFP17003422
Holly Powers
Justin Johnson 7-21-2017
7/21/2017
Print Form I I Reset Form
~~Iffilc@fill ® CITY OF RENTON
TRAFFIC CONTROL PLAN
PROJECT NAME: 2621 Park Ave N Comcast Job 189366 PERMIT#
CONSTRUCTION COMPANY: Prince Telecom LLC PHONE#: 253-891-2899
CONTACT NAME: Ryan Wilkerson PHONE#: 253-261-1882
ADDRESS: 2205 West Valley Hwy E Sumner, WA 98390 CELL#:
E-MAIL ADDRESS: ryan.wilkerson@princetelecom.com FAX#:
PROJECT LOCATION:2621 Park Ave N N/E/S/W OF:
WORK TIME: 8:30AM -4:30PM APPROVED BY:
WORK DATE: 7/24/2017 APPROVAL DATE :
Permit Holder agrees to all the following:
• Comply with all traffic regulations of the City of Renton and the State of Washington .
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for
all street and lane closures, and the plan shall be performed in compliance with the Manual on
Uniform Traffic Control Devices.
• Notify emergency services {253-852-2121) twenty-four {24) hours before any street or lane closures .
• Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200
through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments,
including all costs of defense and attorney's fees incurred in defending against same , arising from and
related to implementation of the approved traffic control plans including claims arising from towing of
private vehicles and the acts of the Permit Holder's agents and employees. . The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or
judgment, and in such event shall indemnify and hold harmless the City for any such claims paid,
including the City's reasonable attorney's fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder
will pay for legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address
traffic or pedestrian safety or travel. . By my signature herein, I acknowledge all the above requirements .
~tlrJ DATE:-=tl I I 1-=r PRINT NAME: ~ OFFICE COPY T-
CONTRACTOR
SIGNATURE:~ hL' DEV . SERVICE, INSPECTION P. MILLER
DEV . SERVICE, PLAN REV IEW B. BANNWARTH
POLICE CHARLES KARLEWICT
FIRE FIRE MARSHALL FS #13
MFP17003422
7-21-2017
Justin Johnson
NOTES:
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Contro l Devices (MUTCD )
and shown by sketch or reference to WSDOT.
• The plan must be submitted to the City's PW/Transportation Division for review and/or approva l at leas t three
working days prior to work.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agenc y to be affected
by a temporary lane or road closure.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when si dewalk or
walkway is impeded .
Total road closure lasting more than 24 hours is subject to the approval by the City Counci l.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying ba r ricade locations fo r
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least t wo signs per block
72 hours in advance of effective date and time.
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Pa r ki ng Sign on the
project site .
• Temporary traffic control devices must be removed immediately when work is done or no construct io n act ivities
are going on. If deemed abandoned, City crews will remove and store them at the City's ma i ntenance shop
(3555 NE 2nd Street).
SKETCH
I
--NORT H --
----... ---·~ -' ~~ I ~\ i
I
I
I
I ~ ";:::) , .... ~ ~ ~ ~ ~~ -,.,
~· ~~. ~ -. ~~o--
c::,j
::t. -i
~ -\I)
--
6/29/2017 2621 Park Ave N -Google Maps
Go g le Maps 2621 Park Ave N
https://www.google.com/maps/place/2621 +Park+Ave+N, +Renton, +WA+98056/@4 7 .5151143,-122.2022014,223a,35y,353.54h/data=!3m1 !1 e3!4m5!3m ... 1/1
SIGN SPACING = X (1) MINIMUM SHOULDER TAPER LENGTH = Ul (feet) RURAL ROADS & URBAN ARTERIALS 35 f40 MPH 350'• Posted Speed (mph) RURAL ROADS, URBAN ARTER!ALS, SHOULDER 25 130 MPH 200':t (2) WDTH RESIDENTIAL & BUSINESS DISTRICTS (feet) 25 lO )5 40 45 so 55 60 65 URBAN STREETS 25 MPH OR LESS 100':t (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE 8' 40 40 60 90 INTERSECTIONS AND DRIVEWAYS. w 40 60 90 90 (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. USE A 3 DE\llCES TAPER FOR SHOULDERS LESS THEN 8' I----- -- - -------7 0 D 70 - -D CHANNELIZATION DEVICE SPACING (feetl MPH I TAPER I TANGENT 15140 I 10 I 60 25110 I 20 I 40 -;1 ---& D D D D -D BUFFER DATA LONGITUDINAL BUFFER SPACE • B SPEED(MPH) I 25110 I 15 I 40 I 45 J so J ss J 60 J 6s i 10 LENGTH (leeQ I 155 I 200 I 250 I l05 I I I I I I BUFFER VEHICLE ROLL AHEAD DISTANCE = R TRANSPORTABLE ATTENUATOR MINIMUM HOST VEHICLE ~IGHT 15,000 LBS. THE MAXIMUM 'M:IGHT SHALL BE IN ACCORDANCE 'NITH THE MANUFACTURERS RECOMMENDATION PROTECTIVE VEHICLE MAY BE A 'NORK VEHICLE STRATEGICALLY LOCA TEO TO SHIELD THE 'NORK AREA - -----D '7 30 FEET MIN TO 100 FEET MAX. NO SPECIFIED DISTANCE REQUIRED 0 I 033 T~$£~ () Kl Kl 0 (1 0 (1 I I f 0 x x Ul B I ~ LEGEND Kl TEMPORARY SIGN LOCATION D CHANNELIZING DEVICES CE8 PROTECTIVE VEHICLE W20.1 W21-5 SHOULDER CLOSURE -LOW (40 MPH OR LESS) NOT TO SCALE S:\DHI n R P& S\4-Stand•rds\2-Plan Shfft Libra \01-Publlshed PSL C Wor11: Zon. Tratnc Control\W C-S Shoulder Closure • Low S d 40 M H or LeH)\TC-5.dgn FILE NAME ~ DATE PLOTIED BY DESIGNED BY ENTERED BY CHECKED BY PROJ.ENOR REGIONAL A.OM. 1:20:14 PM M~ mt1 FED.AID PROJ.NO, ~~~14 WASl-1 ---1-REVISION DA.TE I BY -=-'·t.•T .... IOJI SPEED ----o;;:n-' , ......... .,. I 50' NOTES: 1. DEV\CE SPACING FOR THE 00\NNSTREAM TAPER SHALL BE 20' (Fl) 2. All SIGNS ARE BLACK ON ORANGE. ..... ~k>~1toll w TCS I---Washington State DepartmentofTransportaUon 1-------------------; TRAFFIC CONTROL PLAN traffic control needs tobe site specific